2GIG-FT1-345
FLOOD AND TEMPERATURE DETECTOR
INSTALLATION INSTRUCTIONS
The 2GIG-FT1-345 is a fully supervised, tamper protected one-way 345 MHz
sensor. It will monitor the ambient temperature and/or will detect a wet/dry flood
condition. The sensor reports wet/dry conditions and temperature to the panel.
Flood Conditions
Once the sensor probe detects the presence of water for three (3) minutes, the
integral transmitter will send a wet alarm transmission to the panel. The probe will
also send a restore (dry) report when the presence of liquid is no longer detected
by the flood probe for three (3) minutes. For flood reporting the sensor requires
the installation of the supplied external flood probe. The sensor is capable of
detecting clean or dirty fresh water, salt water, or tap water.
Temperature Conditions
Heat:
1.
If the temperature is more than 95° F (35°C) for five (5) minutes, the sensor
will send a loop 2 transmission.
2.
If the temperature is less than 95°F (35°C) for five (5) minutes, the sensor will
send a loop 2 clear.
Cold:
1.
If the temperature is less than 41°F (5°C) for five (5) minutes, the sensor will
send a loop 3 transmission.
2.
In the temperature is more than 41°F (5°C) for five (5) minutes, the sensor
will send a loop 3 clear.
Contents
Verify that the package includes the following:
• 1—2GIG Flood/Temperature Sensor
• 1—Sensor Mounting Plate
• 1—3V Lithium Battery ( Panasonic CR15H270 uninstalled)
• 3—3/8” Phillips Screws
• 1—Double Stick Tape Strip
• 1—Probe Mounting Plate
Installation Tools Required
• Phillips Screwdriver
Figure 1.
Temperature/Flood

Sensor Contents
A
Double Stick Tape Strip
B
Sensor Mounting Plate
C
Probe Mounting Plate
D
3V Lithium Battery
E

Phillips Screws (3/8”)
F

Flood Probe Cord
G

Flood Probe
H
Transmitter with Integral Temperature Sensor
Installing and Replacing Battery
Open Sensor Case as show in Figures 2 and 3.
Install or replace battery.
Figure 2.
Opening Sensor Case
Grip the base of the sensor case. Place thumb on tab and push down until sensor
case separates.
Figure 3.
Separate Sensor Case
Figure 4.
Installing New Battery
Installing a New Battery and System Programming
NOTE:
Do not install battery until panel is in Sensor Programming Mode.
1.
Place panel in Sensor Programming mode
2.
Insert battery
3.
Close sensor
Replacement Battery Installation:
NOTE:
If battery has been previously installed
1.
Remove battery and dispose of (meeting state regulations)
2.
Wait two (2) seconds
3.
Replace battery
4.
Close sensor
Installing/Mounting Flood/Temperature Sensor
The 2GIG-FT1-345 Flood and Temperature Sensor includes two methods of
installation:
1.
Double Stick Tape Installation (See Figure 5).
2.
Screw/Mounting Plate Installation (See Figure 6).
It is strongly recommended that the Flood/Temperature Sensor be mounted using
screws (provided) and Mounting Plate (provided).
Figure 5.
Double Stick Tape Mounting Sensor Mounting Plate
A
B
C
D
E
F
G
H
1. PUSH DO
WN ON
THUMB
TA B.
2. PULL BA
CK PLA
TE
OFF OF CO
VER
BATTER
Y REMO
VAL
AND/OR INST
ALLA
TION
BATTER
Y
TEMPERA
TURE/
FLOOD SENSOR
BASE
REMO
VE SENSOR
CO
VER FR
OM
SENSOR BASE
MOUNTING
PLA
TE
DOUBLE
STICK
TAPE
STRIP
FLOOD/
TEMPERA
TURE
SENSOR

FIRST
PUSH
SENSOR
ONT
O
MOUNTING
PLA
TE
TABS


THEN
PUSH
UP
APPL
Y DOUBLE STICK
TAPE
TO BA
CK OF
MOUNTING PLA
TE
WALL 2
Copyright © 2015 Nortek Security & Control
Figure 6.
Screw Mounting Sensor Mounting Plate
Removing Flood/Temperature Sensor from Mounting Plate
If Flood/Temperature Sensor needs to be removed from the wall (for changing out
battery), open sensor case (See Figures 2 and 3). Remove battery, then Press Down
on release tab with flathead screwdriver and pull sensor UP.
Figure 7.
Removing Sensor from Wall/Mounting Plate
Mounting Flood Probe
The Flood Probe must be mounted at floor level using the Probe Mounting Plate
and screw (included) mount as shown in Figure 8.
Figure 8.
Mounting Probe Mounting Plate at Floor Line
Flood/Temperature Specifications
Operating Temperature:
32
°
to 120
°
F (0
°
to 49
°
C)
Operating Rel. Humidity:
5 to 95%, non-condensing
Operating Frequency:
345 MHz
Battery Type:
CR2 3V lithium battery
Projected Battery Life:
5 Years
Supervisory Interval
70 Minutes
REGULATORY INFORMATION
This equipment has been tested and found to comply with the limits for Class B Digital
Device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures.
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver
is connected
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils
radio exempts de licence. Ľexploitation est autorisée aux deux conditions suivantes: (1)
ľappareil ne doit pas produire de brouillage, et (2) ľutilisateur de ľappareil doit accepter tout
brouillage radioélectrique subi, même si le brouillage est susceptible ďen compromettre le
fonctionnement.
FCC COMPLIANCE STATEMENT
This device complies with FCC Rules and Regulations as Part 15 devices as well as Industry
Canada license exempt RSS Rules and Regulations. Operation is subject to the following two
(2) conditions: This device may not cause harmful interference. This device must accept any
interference received, including interference that may cause undesired operation.
LIMITED WARRANTY
This Nortek Security & Control LLC product is warranted against defects in material and
workmanship for two (2) years. This warranty extends only to wholesale customers who
buy direct from Nortek Security & Control LLC or through Nortek Security & Control normal
distribution channels. Nortek Security & Control does not warrant this product to consumers.
Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty,
if any.
There are no obligations or liabilities on the part of Nortek Security & Control for consequential
damages arising out of or in connection with use or performance of this product or other
indirect damages with respect to loss of property, revenue, or profit, or cost of removal,
installation, or reinstallation. All implied warranties for functionality, are valid only until the
warranty expires. This Nortek Security &Control Warranty is in lieu of all other warranties
expressed or implied.
Nortek Security & Control LLC
1950 Camino Vida Roble, Suite 150
Carlsbad, CA 92008-6517 USA
For technical support in the USA and Canada:
855-2GIG-TECH (855-244-4832)
Email: 2gigtechsupport@nortek.com
Visit www.nortekcontrol.com for technical support hours of operation
For technical support outside of the USA and Canada:
Visit dealer.2gig.com for a list of distributors in your region
10008993 B
SENSOR
MOUNTING
PLA
TE

FIRST
PUSH
SENSOR
ONT
O
MOUNTING
PLA
TE
TABS


THEN
PUSH
UP
MOUNT SENSOR
MOUNTING PLA
TE
WITH SCREWS (INCLUDED)
WALL
MOUNT FLOOD
PR
OBE MOUNTING
PLA
TE AT
FLOOR LINE
FLOOD PR
OBE
SCREW F
ASTENER
INST
ALL FLOOD
PR
OBE
TO MOUNTING
PLA
TE UNTIL IT
“SNAPS

INT
O THE SIDE CLIP
SIDE CLIP
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,2GIG-FT1 TEMP FLOOD SENSOR - P/N: 10008993 B- INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 8.5000” X 11.000” - TOL. +/- 0.125”- SCALE: 1-1 - PAGE 2 OF 2- FOLDING: FOLD 4X TO FINAL SIZE: 2.125" X 2.750"- FINISH WITH LOGO SHOWING
2GIG Flood & Temperature Control I Instruction Manual
OPEN SENSOR
CASE AND REMO
VE
BATTER
Y
PRESS
DO
WN ON
TAB IN UPPER LEFT
CORNER
WITH FLA
THEAD
SCREWDRIVER
THEN
PUSH UP
ON
SENSOR CASE
TO REMO
VE


Uploaded