Alarm.com Bed Occupancy Sensor w/DSC 433 MHz Transmitter - Install Guide



Related Products

Taxons
Alarm.com Bed Sensor for DSC
Wellness Sensor w/ 433 MHz Transmitter

Document Transcript

Bed Sensor System with DSC Transmitter
ADC-BOS-BC23-DSC
Bed Occupancy Sensor 433MHz
DSC Compatible
Specifications
Mat
30 in. x 11 in. x 0.3 in. (L x W x D) Dark blue, water-
resistant, antimicrobial nylon cloth RF-sealed with black,
water-resistant, slip-resistant, polyester cloth
Cable
Gray, 18in, 26 AWG, 4 conductor sheathed, terminated
with RJ9 connector
Electronic Enclosure
White, 3.5 in. x 2.5 in. x 0.8 in. ABS plastic
Electronic Signaling
Battery-powered filter circuit with integrated 433
MHz
(crystal-controlled) DSC-compatible transmitter with 64
minute supervisory interval
Activation Weight
Minimum 50 lb. subject directly above mat
Sensing Interface
Filtered, normally open (i.e. when not occupied),
momentary contact switch
Material Life
Typically 2 years
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Bed_Sensor_System/Bed_Sensor_Syste...
Updated: Mon, 16 Sep 2019 15:57:48 GMT
1 Programming

Use the Alarm.com AirFX
Add a Sensor
page or the panel interface to add the bed sensor to the account. Set the
New Sensor Information
as shown in the chart to the right.

For testing, the sensor can be tampered by pressing and holding the red button on the transmitter box for 5
seconds, until the red LED illuminates, and then releasing the button.

After the sensor is added to the system, change the sensor type to
Occupancy
by doing the following:

From the
Equipment
page of the Dealer
Website, click
Change
to the right of the sensor’s name. Select the
Change Sensor Type
action, and update the new sensor type to
Occupancy
.
Sensor ID
Serial Number (ESN)
Zone Definition
26
Sensor Name
(Any)
Serial Number (ESN)
(Inside the battery compartment of the transmitter)
Installation and testing
1.
Locate the sensor within 100 feet of the base station.
2.
Place the sensor on top of a mattress and below the sheets with the dark blue side facing up. The sensor should
be positioned directly under the hip area when an individual is lying down. The sensor should be placed
horizontally across the bed. It is recommended that the bed sensor is placed under a thin mattress pad to improve
comfort.
3.
Tuck the transmitter and any excess cable between the mattress and box spring.
4.
To test the bed sensor, apply weight directly above the mat for several seconds and release. View the
Event
History
page on the Dealer Website to confirm the sensor activity.
Use
1.
Lie flat on the bed with hips directly positioned on top of the mat.
2.
Do not bend or fold the sensor.
Care
1.
Wipe down with moistened cloth (i.e. water and soap or mild disinfectant), and wipe dry.
2.
Do not machine wash.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Bed_Sensor_System/Bed_Sensor_Syste...
Updated: Mon, 16 Sep 2019 15:57:48 GMT
2


Uploaded