Danalock Version 3 Z-Wave - Install Guide



Related Products

Danalock DLOV3BTZU Side - V3 Z-Wave Smart Lock
Danalock DLOV3BTZU
V3 Z-Wave Smart Lock

Related Categories


Document Transcript

1

|
P a g e



Danalock

V3

Product manual

The

Danalock

V3 Z
-
Wave

is a secure electronic door lock that supports the Z
-
Wave Plus standard, which is
compatible with earlier versions of Z
-
Wave. The

Danalock

is battery supplied and therefore it is a FLIRS
Frequently Listening Routing Slave

which conserves battery

The Danalock V3 is a security enabled Z
-
Wave Plus
Product. A security enable
d Z
-
Wave controller must be use
.
The Danalock V3 supports
the standard security S0
and
the new security standard S2.
This manual covers all version
s

of Danalock V3 Z
-
Wave
.

This manual is
accompanied by the mounting manually for your specific lock.

Z
-
Wave interoperability


The

Danalock

can be included and
operated in any Z
-
Wave network with other Z
-
Wave certified devices from
other manufacturers and/or other applications. All non
-
battery operated nodes within the network will act as
repeaters regardless of vendor to increase reliability of the network.


Z
-
W
ave add/inclusion and remove/exclusion




To add or include the

Danalock

into a Z
-
Wave network

1.

Set the controller in inclusion mode

2.

Push the
switch

once.

3.

Wait 5 seconds.



To remove or exclude the

Danalock

into a Z
-
Wave network

1.

Set the controller in exclusion

mode

2.

Push the
switch
once
.

3.

Wait 5 seconds.

Factory Reset


The

Danalock

can be set to factory settings by
pushing the
switch
ten times.
Please use this procedure only
when the primary controller is missing or otherwise inoperable
.


Batteries


The Danalock uses 4 CR123A batteries. Only use four new batteries

from

the

same manufacturer. Do not mix new and old batteries.



The Package contains



Danalock

V3



Batteries

(may not be included)



M
anual



Adapters (may vary from country to country)




If
the Danalock is firstly included on a Z
-
Wave network, the Bluetooth Smart is disabled because of security and
to conserve power. To enable Bluetooth Smart enable Configuration byte no. 5.

2

|
P a g e



Supported Command Classes

Command Class

Version


Not added


Non
-
Sec
ure
added

Securely added

Non
-
secure
CC

Secure CC

Z
-
Wave Plus Info

2

Support

Support

Support


Transport Service

2

Support

Support

Support


Security 0

1

Support

Support

Support


Security 2

1

Support

Support

Support


Association

2




Support

Association Grp Info

1




Support

Battery

1




Support

Configuration

1




Support

Device Reset Locally

1




Support

Door lock

2




Support

Firmware update MD

4




Support

Manufacturer Specific

2




Support

Notification

8




Support

Power level

1




Support

Superversion

1




Support

Version

2




Support

Node

Info

Generic Device Class

0x40
GENERIC_TYPE_ENTRY_CONTROL

Specific Device Class

0x
03

SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK

Association CC V2 (secure)

Associations Groups

Group 1 is
Lifeline. All unsolicited reports are sent to the node in Lifeline. The

Danalock

can send the following
commands through Lifeline:

ID

Name

Node Count

Description

1

Lifeline

1

Supports the following command classes:



Device Reset Locally: triggered upon
reset.



Battery/notification: triggered upon low battery.



Door Lock

operation report: triggered upon a change in door lock



N
otification: trigg
ered upon a change in door lock

Battery CC V1 (secure & unsecure)

The Battery Get request can be used to get the

status of the bat
tery. To get a
useful

battery level the motor of
the lock should be operated at least once
for

the lock to sample a meaningful battery level.

When battery
level is low a battery warning is send to the controller.





3

|
P a g e


Configuration CC V1
(secure)

Z
-
Wave
parameter
no.

Parameter Name

Parameter
Size

Default
value

Description

1

TWIST_ASSIST

1

Byte

0

0 = Disabled, 1=Enabled

2

HOLD_AND_RELEASE (brake and go back)

4

Byte
s

0

0=Disabled, 1
-
2147483647
(hold seconds)

3

BLOCKED_2_BLOCKED(async)

1

Byte

0

0 = Disabled, 1=Enabled

4

BLE_TEMPORARY_ALLOW_TIMER

4

byte
s

0

0=Disabled, 1
-
2147483647
(seconds to allow)

5

BLE_ALWAYS_ALLOWED

1

byte

0

0 = Disabled, 1=Enabled

6

Autolock

4 byte
s

0

0 = Disabled,
1
-
2147483647

seconds of delay before
autolock
enable.

Device Reset Locally CC V1 (unsecure)

When the Z
-
W
ave module is reset it sends a report to tell the controller it has been reset. The lock is reset by
pushing the switch 10 times
. Please use this procedure only when the primary controller is
missing or otherwise
inoperable


Door Lock CC V2 (secure)

Door Lock Operation is used to lock and unlock the

Danalock
. See table to see how the Door Lock Mode
paramater affects the lock.

Door Lock Operation

Paramater


Secured

Unsecured

Door Lock Mode

0xFF

0x00
-
0xEF

In a Door Lock Operation Report the

Danalock

will report:

Door Lock Operation Report

Value
\
Door status

Unlocked

L
ocked

Door Lock Mode

0x00

0xFF

Handles

0x11

0x11

Door Condition

0x02

0x05

Lock Timeout Minutes

0xFE

0xFE

Lock Timeout
Seconds

0xFE

0xFE

The

Danalock

does not use the Door Lock Configuration to adjust settings, the
C
onfiguration
CC is

used
instead. The

Danalock

ignores Door Lock Configuration Set frames and response a Door Lock Configuration
Get with:

Door Lock
Configuration Report

Parameter

Value

Operation Type

Constant operation(0x01)

Handles

Handle 1 enabled (0x11)

Lock Timeout Minutes

Timeout not su
pported(0xFE)

Lock Timeout Seconds

Timeout not supported(0xFE)

4

|
P a g e


Firmware Update Meta Data CC V4

(secure)

The

Danalock

supports firmware update of the Z
-
Wave module over the air.


The firmware upgrade takes ~30 min with S0 and
~
20 min with S2.

Firmware ID = 0x0A01
.

Firmware 0 ID = 0x0000
.

Manufacture Specific CC V2 (secure & unsecure)


Value

Comment

Manufacturer ID

0x010E

Poly
-
control

Product Type ID

0x0009

Danalock V3

Series

Product ID

0x0001

Lock

The
Device specific report

returns the 6 byte long DMI serial number of the host.

Notification CC V8

(secure)

The Notification CC is implement
ed as a
push only, which means only

pushes notification to the controller.
Sequence number is not supported.



Supported notifications

Notification Type

Event

Comments

Access Control
(0x06)

Manual Lock Operation (0x01
)

User Touch button used to lock the door.


Manual Unlock Operation (0x02)

User Touch button used to unlock the door.


RF Lock Operation (0x03)

Bluetooth

or
Z
-
wave initiated the operation


RF Unlock Operation (0x04)

Bluetooth or Z
-
wave initiated the operation


Auto Lock Locked Operation(0x09)

The Auto Latch time has locked the door.

Not
used. Auto locks sends (0x01) instead.


Lock Jammed (0x0B)

The lock/unlock operation could not be
completed.



Power Level CC V1 (secure & unsecure)

Can be used under inclusion to test signal strength from the

controller and to the device.


Security CC V1 (secure & unsecure)

See Z
-
Wave documentation.

5

|
P a g e


Security CC V2 (secure & unsecure)

The Danalock support S2_ACCESS security class.

Superversion

V1
(secure)

See Z
-
Wave documentation.

Transport Service

V2
(secure)

See Z
-
Wave documentation.

Version CC V2 (secure)

This Command Class is used to get information about which version of the different command classes
the

Danalock

supports and the software version of the

Danalock
.

Version Report

Z
-
W
ave Library Type

ZW_LIB_SLAVE_ENHANCED(0x03)

Z
-
Wave Protocol Version

0x
04

(
SDK v6.71.01
)

Z
-
Wave Protocol Sub Version

0x3D
(
SDK v6.71.01
)


Firmware 0 version

Version of the firmware on the Z
-
Wave module

Version

Subversion

Comments

1

2

First release



Firmware 1
version

Version of the firmware on the
Host
.

Version

Subversion

Comments

0

7

First release


Hardware version

0
x02

Danalock

V3

Z
-
Wave Plus Info CC V2 (secure & unsecure)

Z
-
Wave Plus Info

R
oleType

0x07
ROLE_TYPE_SLAVE_SLEEPING_LISTENING

N
odeType

0x00
NODE_TYPE_ZWAVEPLUS_NODE

I
nstallerIconType

0x03
ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD

U
serIconType1

0x03
ICON_TYPE_GENERIC_DOOR_LOCK_KEYPAD


6

|
P a g e


Controller

I
ntegration

When the Danalock has been included into the network, the controller should:



Set the
Lifeline. Association group 1



Enable Notification for Access Control

Test information

Configuration Parameters

When testing config parameter 4. Be aware that this is a count down, so a set and then a get will not
return

the
same value.

Battery Warning

To get the lock to send a battery war
ning the voltage must
be low
AND

the motor must be operated. The lock
only measures the battery voltage under load to get the most precise result. By using a 1 A voltage adjustable
t
ransformer
with approximately
1 meter

of wire

the following
data has been collected.

Voltage

Battery report value

12 V

0x62 (98%)

9V

0x26 (38%)

7,5V

0x0B (11%) (
B
attery warning

is send
)

No reports
received


If no reports are
received from the lock it is most likely because the lock is not calibrated and thereby does not
no know when the lock is lock or unlock and therefore it does not send reports to the gateway. There are two
ways to calibrate the lock.

1.

Autocalibration. Turn

the Danalock manually until the door is unlocked and leave the door open while
calibrating. Lift the handle if needed. Now click 3 times, after 5 seconds the Danalock will calibrate.

2.

Manual calibration (start by turn to unlock). Turn the Danalock complet
ely into unlock position, then
click twice. Wait 5 seconds until it flashes yellow, then turn the Danalock into locked position and click
once.


Uploaded