Honeywell 1361 Install Guide

Honeywell 1361 Transformer Wiring
for a Shared Installation
For Online Support visit: http://www.securi
ty.honeywell.com/hsc/resources/MyWebTech/
INTRODUCTION:
This guide shows how to wire the Honeywell 1361 Transformer (16.5VAC, 40VA) when it is desired to power both
the control panel and the GSMV or IGSMV Communications Module from one transformer.
IMPORTANT:
!
You must use the Honeywell 1361 Transformer.
!
This configuration ONLY applies to the VISTA-10P, VISTA-15P, VISTA-20P control panels when used
with the GSMV or IGSMV Communications Module.
!
DO NOT use this configuration wi
th any other control panel.
!
DO NOT use this configuration if using two-way voice.
!
This configuration has not been evaluated by UL.
To wire the transformer, perform the following steps:
1.
If the control panel and/or communications module
is already powered, remove AC power, then
disconnect the battery on each unit.
2.
Wire the Honeywell 1361 Transformer as shown below.
CONTROL PANEL
TO 110 VAC
UNSWITCHED
OUTLET
iGSMBR-014-V0
12
30 FT. MAX TO MODULE
18 AWG. WIRE (MIN)
1361
TRANSFORMER
2
1
COMMUNICATIONS
MODULE
3.
At the control panel, plug the transformer in.
4.
Reconnect the battery at the control panel and the communications module.
WARRANTY:
For the latest warranty information go to:
http://www.security.honeywell.
com/hsc/resources/wa/
Ê800-08251$Š
800-08251 2/11 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright
"
2011 Honeywell International Inc.
www.honeywell.com/security
of 1


Related Products

Honeywell 1361-GT - AC Transformer 16.5VAC, 40VA
Honeywell 1361-GT
AC Transformer 16.5VAC, 40VA
List Price: $34.00
Our Price: $24.99

Related Categories


Document Transcript

Honeywell 1361 Transformer Wiring for a Shared Installation
For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/

INTRODUCTION: This guide shows how to wire the Honeywell 1361 Transformer (16.5VAC, 40VA) when it is desired to power both the control panel and the GSMV or IGSMV Communications Module from one transformer. IMPORTANT: ! You must use the Honeywell 1361 Transformer. ! This configuration ONLY applies to the VISTA-10P, VISTA-15P, VISTA-20P control panels when used with the GSMV or IGSMV Communications Module. ! DO NOT use this configuration with any other control panel. ! DO NOT use this configuration if using two-way voice. ! This configuration has not been evaluated by UL. To wire the transformer, perform the following steps: 1. If the control panel and/or communications module is already powered, remove AC power, then disconnect the battery on each unit. 2. Wire the Honeywell 1361 Transformer as shown below.

COMMUNICATIONS MODULE

CONTROL PANEL

1 2
1 2

1361 TRANSFORMER 30 FT. MAX TO MODULE 18 AWG. WIRE (MIN) TO 110 VAC UNSWITCHED OUTLET
iGSMBR-014-V0

3. At the control panel, plug the transformer in. 4. Reconnect the battery at the control panel and the communications module.