Honeywell 5800C2W Data Sheet

Hardwired to 5800
w
ireless Converter
t
he Honeywell 5800C2
w
Hardwired to 5800
w
ireless
Converter enables retrofitting existing 12-volt security systems
by converting their wired sensors to Honeywell’s 5800
s
eries
wireless technology.
i
ts ideal uses are to upgrade hardwired
systems to
l
Y
n
X
t
ouch systems to provide connected
home and business functionality, or upgrade to
l
Y
n
X Plus
for traditional security.
i
n addition, it can be used in new
construction installations that have been fitted with hardwired
systems. Converting existing wired zones to wireless saves
on installation cost, time and materials since there is no need
to replace wired devices with individual transmitters.
Honeywell’s 5800C2
w
is simple to install and extremely
flexible.
i
t can power wired P
ir
s, and the included power
supply is backed up with a standard, rechargeable battery.
o
ne button calibration automatically configures 5800C2
w
by
learning what zones are in use.
s
et-up is a three step process:
1.
Mount and wire the module
2.
Calibrate/activate the module zones
3.
e
nroll the module’s wireless zones into the control
panel
Nine
hardwired
zones
with
end-of-line
resistor protection – use with existing
contacts, P
ir
s, glassbreaks and
other
12
v
sensors
n
ot for use with fire or heat
sensors
i
t is recommended that any existing
smoke, heat or C
o
detectors be
replaced with new Honeywell 5800
s
eries detectors
One-button
calibration/activation
of
zone inputs
5800C2W
wireless
zones
enroll
in the control panel like any other
5800
s
eries device
5800
Series
serial
numbers
automatically assigned to
activated
zones
Power
supply
included
to
power
PIRs
12
v
4
a
H battery provides four hours
of standby
l
ow battery supervision
and
notification
• Case
tamper
switch
Complete
supervision
of
transmitters,
zone tampers, low
battery
Module
can
be
mounted
next
to
the control panel being replaced,
or
relocated if necessary to maximize
wireless range
Features
5800C2W
Dimensions
Length
178mm
(7.0
inches)
Width
114mm
(4.5
inches)
Depth
38mm
(1.5
inches)
Mounting Hardware
Double
stick
tape
and
screws
included
Operating
t
emperature
10°C
to
+60°C
(+14°F
to
+140°F)
Humidity
95%
RH
Max
t
ransmission
r
ange
Up
to
91
meters
(300
feet)
Operating Voltage
Supplied
by
plug-in
power
supply
(15.5VDC
@
1A)
Battery Backup (not included)
Use
12V,
4AH
battery
such
as
Honeywell
467,
Yuasa
NP4-12,
Casil
C
a
1240 or equivalent. Provides
four hours of backup. Battery is to
be located in the existing control
panel.
do
not
use batteries of
larger
capacity.
t
amper Detection
Activated
when
the
cover
is removed
5800C2W
s
upervision
Low
battery
Backup
battery
power
Each
enrolled
zone
transmits
a
supervisory
message
every
72
minutes
L
e
D
s
tatus Indicators
Input
power
Backup
power
Wireless
transmission
Input Zones (Nine Hardwired)
All
zones
that
are
used
must
have
an
eol
resistor
a
uxiliary Output (12V
au
X)
Provides
9.5
to
14VDC
@
100m
a
to supply P
ir
motion or
glassbreak
sensors
a
gency Listings
ETL
Listed
to
UL
1023
cETL
Listed
to
ULC-C1023
spe
CIFIC
at
ION
s
a
pplication Diagram
O
r
D
er
IN
g
5800C2W
Hardwired to 5800
w
ireless Converter
5800C2WCN
Hardwired
to
5800
Wireless
Converter
(Canada)
a
utomation and Control
s
olutions
Honeywell
s
ecurity Products
a
mericas
2 Corporate Center
d
r.
s
uite 100
P.O.
Box
9040
Melville,
NY
11747
1.800.467.5875
www.honeywell.com
Zone
1
of
9
shown
wired.
NO
tes
:
• All
zones
that
are
used
MUST
have
an
EOL
resistor.
If
the
existing
installation
zones
have
EOL
resistors
(from
1k
to
10k
ohms)
they may remain.
EOL
resistor
values
must
be
from
1k
to
10k
ohms.
For
a
NC
loop
without
an
EOL
resistor,
you
must
add
one
in
series
with
the loop.
For
a
NO
loop
without
an
EOL
resistor,
you
must
add
one
in
parallel
(across)
the
loop.
Preferably
it
should
be
located
at
the
end
of
the
loop
furthest away from the control panel.
l
/5800C2
wd
/
d
n
ovember 2013
© 2013 Honeywell
i
nternational
i
nc.
To backup battery
located in existing
control panel
Zone Calibration button
Not used
Provides 9.5 to 14VDC @ 100mA
to supply PIR motion detectors or
glassbreak sensors
OBSERVE
POLARITY
Upgrading a hardwired panel;
usually mounted in utility area.
LYNX Systems
Existing Har
dwired Sensors
L
e
D
Function Note:
led
s are shown as they appear on the circuit board.
#1
Red
(blinking)
Module
needs
calibrating.
Gr
een – Module is calibrated.
#2
Green
DC
power
(15.5VDC,
+
/–
5%)
fr
om
the
plug-in
transformer is pr
esent.
r
ed –
d
C power is
not
present.
#3
Yellow –
l
ow battery or
n
o battery.
w
hen the battery voltage
drops below 11.2
vd
C, a low battery message is sent to the
control panel and
led
3 turns yellow.
w
hen the battery voltage drops below 10.3
vd
C, the battery
is disconnected.
t
he battery will not connect again until
a
C is restored.
#4
Green
(blinking)
RF
signal
transmission.
Hardwired to 5800
w
ireless Converter
5800C2W
of 2


Related Products

Honeywell 5800C2W PCB - Hardwire to Wireless System 9-Zone Conversion Module
Honeywell 5800C2W
Hardwire to Wireless System 9-Zone Conversion Module
List Price: $158.00
Our Price: $111.99

Document Transcript

5800C2W
HARDWIRED TO 5800 WIRELESS CONVERTER

The Honeywell 5800C2W Hardwired to 5800 Wireless Converter enables retrofitting existing 12-volt security systems by converting their wired sensors to Honeywell’s 5800 Series wireless technology. Its ideal uses are to upgrade hardwired systems to LYNX Touch systems to provide connected home and business functionality, or upgrade to LYNX Plus for traditional security. In addition, it can be used in new construction installations that have been fitted with hardwired systems. Converting existing wired zones to wireless saves on installation cost, time and materials since there is no need to replace wired devices with individual transmitters.

Honeywell’s 5800C2W is simple to install and extremely flexible. It can power wired PIRs, and the included power supply is backed up with a standard, rechargeable battery. One button calibration automatically configures 5800C2W by learning what zones are in use. Set-up is a three step process: 1. Mount and wire the module 2. Calibrate/activate the module zones 3. Enroll the module’s wireless zones into the control panel

FEATURES
• Nine hardwired zones with end-of-line resistor protection – use with existing contacts, PIRs, glassbreaks and other 12V sensors – Not for use with fire or heat sensors – It is recommended that any existing smoke, heat or CO detectors be replaced with new Honeywell 5800 Series detectors • One-button calibration/activation of zone inputs 5800C2W wireless zones enroll • in the control panel like any other 5800 Series device • 5800 Series serial numbers automatically assigned to activated zones • Power supply included to power PIRs –1 2V 4AH battery provides four hours of standby – Low battery supervision and notification • Case tamper switch • Complete supervision of transmitters, zone tampers, low battery • Module can be mounted next to the control panel being replaced, or relocated if necessary to maximize wireless range

5800C2W
HARDWIRED TO 5800 WIRELESS CONVERTER

SPEcificATionS
Dimensions Length 178mm (7.0 inches) • Width 114mm (4.5 inches) Depth 38mm (1.5 inches) Mounting Hardware • Double stick tape and screws included Operating Temperature • – 10°C to +60°C (+14°F to +140°F) Humidity • 95% RH Max Transmission Range Up to 91 meters (300 feet) • Operating Voltage • Supplied by plug-in power supply (15.5VDC @ 1A) Battery Backup (not included) • Use 12V, 4AH battery such as Honeywell 467, Yuasa NP4-12, Casil CA1240 or equivalent. Provides four hours of backup. Battery is to be located in the existing control panel. DO NOT use batteries of larger capacity. Tamper Detection • Activated when the cover is removed 5800C2W Supervision Low battery • • Backup battery power • Each enrolled zone transmits a supervisory message every 72 minutes LED Status Indicators • Input power • Backup power • Wireless transmission Input Zones (Nine Hardwired) • All zones that are used must have an EOL resistor Auxiliary Output (12VAUX) • Provides 9.5 to 14VDC @ 100mA to supply PIR motion or glassbreak sensors Agency Listings ETL Listed to UL 1023 • • cETL Listed to ULC-C1023

Application Diagram
Zone Calibration button Not used

LED #1
To backup battery located in existing control panel

Function Note: LEDs are shown as they appear on the circuit board. Red (blinking) – Module needs calibrating. Green – Module is calibrated. Green – DC power (15.5VDC, + /– 5%) from the plug-in transformer is present. Red – DC power is NOT present. Yellow – Low battery or No battery. When the battery voltage drops below 11.2VDC, a low battery message is sent to the control panel and LED 3 turns yellow. When the battery voltage drops below 10.3VDC, the battery is disconnected. The battery will not connect again until AC is restored. Green (blinking) – RF signal transmission.

#2

OBSERVE POLARITY Provides 9.5 to 14VDC @ 100mA to supply PIR motion detectors or glassbreak sensors

#3

#4

Zone 1 of 9 shown wired. NOTES: • All zones that are used MUST have an EOL resistor. • If the existing installation zones have EOL resistors (from 1k to 10k ohms) they may remain. • EOL resistor values must be from 1k to 10k ohms. • For a NC loop without an EOL resistor, you must add one in series with the loop. • For a NO loop without an EOL resistor, you must add one in parallel (across) the loop. Preferably it should be located at the end of the loop furthest away from the control panel.
Upgrading a hardwired panel; usually mounted in utility area. LYNX Systems Existing Hardwired Sensors

oRdERinG
5800C2W 5800C2WCN Hardwired to 5800 Wireless Converter Hardwired to 5800 Wireless Converter (Canada)

Automation and Control Solutions Honeywell Security Products Americas 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 1.800.467.5875 www.honeywell.com

L/5800C2WD/D November 2013 © 2013 Honeywell International Inc.


Uploaded