Basic Programming for the Honeywell ZSTAT Thermostat and 5800ZBRIDGE
Notes before you begin: • If you need help wiring your thermostat, please call 1-800-468-1502 o If required please have a licensed professional install your product for you.

Programming the thermostat: 1. Press System: 2. Press the 3rd and 5th buttons simultaneously

3.

Used the following buttons to program: Use the Up and down arrows to enter the desired value.

Use the Up and down arrows to scroll through the questions (fields).

-1-

Tech Support Updated 6/7/11

The Follow locations are the bare minimum fields required for operation: Setup Functions (Fields)
0120 0130 0140 0150 0160 0615 0616 Year (First 2 Digits) Year (Second 2 Digits) Month Date Schedule Format (Does not affect Z-Wave Operation) Energy Saving Heat Setpoint Energy Saving Cool Setpoint

Settings & Options (Factory default is in bold)
20 (2000-2078) 11 (2011) 6 (1-12) 15 (1-31) 0 (Non Programmable) 4 (Programmable) 65°F (18.5°C) 40-90°F (4.5°C-32°C) 78°F (25.5°C) 50-99°F (10°C-37°C)

Enrolling the House ID in the Z-Bridge Module: 1. Make sure your House ID is set in the panel or local mode of the RF keypads. a. The following devices are compatible • 6150rf • 6160rf • 5883H • Lynx Control Panels 2. Press the SW5 Learn switch for 1 second then release. a. LED will Flash Orange 3. Arm and disarm the control panel. a. The LED will now show status of the panel. Enrolling the Z-Bridge Module into the Honeywell Z-wave thermostat: 1. Navigate through the programming of the thermostat until you reach the following screen:

-2-

Tech Support Updated 6/7/11

2. Next power up the Z-Bridge with the supplied 12v power supply. a. Upon power up the yellow LED will flash 3 times. 3. Press the corresponding switch (1-4) for 1 second then release for any combination of four Thermostats or Lights. a. b. c. d. Switch 1 = Thermostat/Light 1 Switch 2 = Thermostat/Light 2 Switch 3 = Thermostat/Light 3 Switch 4 = Thermostat/Light 4

The LED on the Z-Bridge will begin flashing green.

4. On the Thermostat, change the 0 to a 1 to learn the Z-Bridge.

Change this value to a 1.

Once that is done you will see

Once learned in the LED will flash three times and return to the status of the control panel. 5. Press ‘Done’ to exit programming. Notes: 1. To test the connectivity simply arm and disarm the panel and watch the LED on the Z-Bridge to make sure it is illuminating properly (See Z-Bridge Installation Instructions). 2. To verify the Z-Bridge is communicating with the Thermostat look for the word ‘Saving’ which will be present above the ‘Set To’ temperature. This represents the thermostat is in “Setback Mode’. 3. Locations 0615 (Heat Set Back) and 0616 (Cool Set Back) are End User Programmable. (See the thermostat Owner’s Manual for more information)

-3-

Tech Support Updated 6/7/11