Honeywell VISTA-50P Data Sheet

Honeywell’s VISTA-50P Control Panel provides the flexibility of up to eight independent partitions with the economy
of a single control.
Dependable features to meet your most
demanding installations:
• Nine hardwired zones standard
• Expandable to 87 total zones
• Eight partitions standard
• 75 user codes work in all partitions
• Seven authority levels
• 224 event memory log/printer option
• Four trigger outputs
• 5800 Series wireless compatibility
• Supports two-wire multiplex
• Scheduling of events (real time clock)
• Keypad macro features
• Master console option for viewing all
partitions at a glance
• Common lobby logic
• Fast downloading
• Supports up to 16 relays and/or X-10
• Quick start programming
• False alarm features
• UL Commercial Burglary listed
(VISTA-50PUL)
End users will appreciate the easy-to-use
convenience and control features of the VISTA-50P:
• Wireless remote controls
(featuring single button system operation):
— 5804 - Four-Button Wireless Key
— 5804BD - Bidirectional
Four-Button Wireless Key with
system status feedback
• Single or dual-button wireless
personal panic:
— 5802MN
— 5802MN2
• Home control features activate lights, appliances,
garage doors and numerous other devices
• The VISTA Interactive Phone Module (VIP) gives the
end-user control of their system from any touchtone
phone. The 4286 VIP responds in English, with a
vocabulary of over 100 words
• Full English display keypads for clear understanding
of system status and zone locations
• Timed event applications:
— Opens garage doors and
turns on lights
— Provides“lived-in look” while
away from home
— Ability to limit access to parts of the
home at certain times
FEATURES
VISTA-50P
CONTROL PANEL
L/VIS50P/D
September 2008
© 2008 Honeywell International Inc.
Automation and Control Solutions
Honeywell Security & Communications
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
www.honeywell.com
ORDERING
VISTA-50P
Control Panel
VISTA-50P
CONTROL PANEL
Electrical
• Aux power 12VDC, 750mA max
• 16.5 VAC/40 VA transformer
• Alarm output 12VDC,
1.7 Amps max
• For UL installations, combined
Aux and alarm output cannot exceed
750mA
Output Control
• Supports up to four relay boards
(Part No. 4204)
• Each board supports four relays
for a total of 16
• Optional X-10 interface (Part No.
4300) may be used to control
X-10 receiving devices
• Each X-10 receiver address
counts as one relay when computing
total relays
• Real time clock can be used for
relay/X-10 control
Zones
• Nine hardwired zones
• Selectable response on zone 9:
10MSec or 500MSec
• Assignable to any partition
• 14 zone types to choose from
• Programmable swinger suppression
Communications
• Touchtone or pulse
• Formats supported: ADEMCO
Contact ID, ADEMCO 4 + 2 Express,
ADEMCO low speed
• 3+1, 4+1 and 4+2 reporting
• Reporting capabilities: Split,
Dual, Split/Dual
• Low battery reports 11.2-11.6VDC
• Expanded reporting
• Up to four digit PABX
codes supported
• True dial tone detection
• Double pole line seizure
• AC loss and restoral
reporting supported
Supported Devices
Hardwired Expansion Devices
• 4208U Eight-Zone
Expansion Module
• Keypads
— 6139 Custom English (required for
programming) -100mA
— 6128 Fixed English LCD - 30mA
• Voice Module 4286 VIP-160mA
• Two-Wire Smoke Detectors
• Duct Detectors
• Serial Printer
• Polling Loop Devices
• Key Switch Devices
Wireless Receiver Systems
• 5800 Series
— 5881ENL up to 8 zones-50mA
— 5881ENM up to 16 zones-50mA
— 5881ENH up to 26 zones-50mA
• All Receivers Support:
— Diversity reception with
two antennea
— Remote mounting for
best location
— Use of second receiver for
maximum coverage or
tough installations
— Unique supervision and low
battery indications by point
Transmitters
• 5800 Series
— Three volt Duracell lithium batteries
— One mile range
— Tamper standard
Agency Listings
• UL Residential Fire and Burglary
and CSFM
• UL Commercial Burglary
(VISTA-50PUL)
SPECIFICATIONS
of 2


Related Products

Honeywell VISTA-50P - Alarm Control Panel
Honeywell VISTA-50P
Alarm Control Panel
List Price: $702.00
Our Price: $433.99
Honeywell Tuxedo Touch - Talking Color Graphic Touchscreen Alarm Keypad
Honeywell Tuxedo Touch
Talking Color Graphic Wired Touchscreen Alarm Keypad
Honeywell Tuxedo Touch WIFI - Talking Color Graphic Touchscreen Alarm Keypad
Honeywell Tuxedo Touch WIFI
Talking Color Graphic Touchscreen Alarm Keypad

Related Categories


Document Transcript

VISTA-50P
CONTROL PANEL

Honeywell’s VISTA-50P Control Panel provides the flexibility of up to eight independent partitions with the economy of a single control.

FEATURES
Dependable features to meet your most demanding installations: • Nine hardwired zones standard • Expandable to 87 total zones • Eight partitions standard • 75 user codes work in all partitions • Seven authority levels • 224 event memory log/printer option • Four trigger outputs • 5800 Series wireless compatibility • Supports two-wire multiplex • Scheduling of events (real time clock) • Keypad macro features • Master console option for viewing all partitions at a glance • Common lobby logic • Fast downloading • Supports up to 16 relays and/or X-10 • Quick start programming • False alarm features • UL Commercial Burglary listed (VISTA-50PUL) End users will appreciate the easy-to-use convenience and control features of the VISTA-50P: • Wireless remote controls (featuring single button system operation): — 5804 - Four-Button Wireless Key — 5804BD - Bidirectional Four-Button Wireless Key with system status feedback • Single or dual-button wireless personal panic: — 5802MN — 5802MN2 • Home control features activate lights, appliances, garage doors and numerous other devices • The VISTA Interactive Phone Module (VIP) gives the end-user control of their system from any touchtone phone. The 4286 VIP responds in English, with a vocabulary of over 100 words • Full English display keypads for clear understanding of system status and zone locations • Timed event applications: — Opens garage doors and turns on lights — Provides“lived-in look” while away from home — Ability to limit access to parts of the home at certain times

VISTA-50P
CONTROL PANEL

SPECIFICATIONS
Electrical • Aux power 12VDC, 750mA max • 16.5 VAC/40 VA transformer • Alarm output 12VDC, 1.7 Amps max • For UL installations, combined Aux and alarm output cannot exceed 750mA Output Control • Supports up to four relay boards (Part No. 4204) • Each board supports four relays for a total of 16 • Optional X-10 interface (Part No. 4300) may be used to control X-10 receiving devices • Each X-10 receiver address counts as one relay when computing total relays • Real time clock can be used for relay/X-10 control Zones • Nine hardwired zones • Selectable response on zone 9: 10MSec or 500MSec • Assignable to any partition • 14 zone types to choose from • Programmable swinger suppression Communications • Touchtone or pulse • Formats supported: ADEMCO Contact ID, ADEMCO 4 + 2 Express, ADEMCO low speed • 3+1, 4+1 and 4+2 reporting • Reporting capabilities: Split, Dual, Split/Dual • Low battery reports 11.2-11.6VDC • Expanded reporting • Up to four digit PABX codes supported • True dial tone detection • Double pole line seizure • AC loss and restoral reporting supported Supported Devices Hardwired Expansion Devices • 4208U Eight-Zone Expansion Module • Keypads — 6139 Custom English (required for programming) -100mA — 6128 Fixed English LCD - 30mA • Voice Module 4286 VIP-160mA • Two-Wire Smoke Detectors • Duct Detectors • Serial Printer • Polling Loop Devices • Key Switch Devices Wireless Receiver Systems • 5800 Series — 5881ENL up to 8 zones-50mA — 5881ENM up to 16 zones-50mA — 5881ENH up to 26 zones-50mA • All Receivers Support: — Diversity reception with two antennea — Remote mounting for best location — Use of second receiver for maximum coverage or tough installations — Unique supervision and low battery indications by point Transmitters • 5800 Series — Three volt Duracell lithium batteries — One mile range — Tamper standard Agency Listings • UL Residential Fire and Burglary and CSFM • UL Commercial Burglary (VISTA-50PUL)

ORDERING
VISTA-50P Control Panel
Automation and Control Solutions Honeywell Security & Communications 2 Corporate Center Dr. Suite 100 P.O. Box 9040 Melville, NY 11747 www.honeywell.com

L/VIS50P/D September 2008 © 2008 Honeywell International Inc.


Uploaded