VISTA SERIES VISTA-50P/VISTA-50PUL
Commercial Burglary Partitioned Security System With Scheduling User Guide
N5943-6V2 5/04 Rev B
IMPORTANT!
PROPER INTRUSION PROTECTION
For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the Central Monitoring Station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines).
EARLY WARNING FIRE DETECTION
Early warning fire detection is important in a home. Smoke and heat detectors have played a key role in reducing fire deaths in the United States. With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's National Fire Alarm Code (NFPA 72). These recommendations can be found on page 53 of this manual. SYSTEM COMPATIBILITY NOTICE Your Honeywell security system is designed for use with devices manufactured or approved by Honeywell for use with your security system. Your Honeywell security system is not designed for use with any device that may be attached to your security system's keypad or other communicating bus if Honeywell has not approved such device for use with your security system. Use of any such unauthorized device may cause damage or compromise the performance of your security system and affect the validity of your Honeywell limited warranty. When you purchase devices that have been manufactured or approved by Honeywell, you acquire the assurance that these devices have been thoroughly tested to ensure optimum performance when used with your Honeywell security system.
–2–
TABLE OF CONTENTS
SYSTEM OVERVIEW ....................................5 General .......................................................5 A Partitioned System ..................................5 Zones ..........................................................5 Fire Protection ............................................6 Burglary Protection .....................................6 Alarms.........................................................6 Memory of Alarm ........................................6 Speed Key (Macros) ...................................7 Using Schedules.........................................7 Device Timers.............................................7 To Access another Partition (GOTO Command) ..................................................7 Master Keypad Operation...........................8 Self-Help Feature........................................8 Phone Access & Voice Response Capability ....................................................8 ABOUT THE KEYPADS.................................9 General .......................................................9 The Alpha Keypad ......................................9 FUNCTIONS OF THE KEYPAD ..................10 FUNCTIONS OF THE KEYPAD (CONT’D)..................................................11 FUNCTIONS OF THE KEYPAD (CONT’D)..................................................12 ENTRY/EXIT DELAYS .................................13 General Information ..................................13 SECURITY CODES AND AUTHORITY LEVELS ....................................................14 General Information ..................................14 Duress Code.............................................14 Quick Arming ............................................14 SECURITY CODES AND AUTHORITY LEVELS (CONT’D) ...................................15 Authority Levels ........................................15 SECURITY CODES AND AUTHORITY LEVELS (CONT’D) ...................................16 General Rules on Authority Levels and Changes ...................................................16 To Exit User Edit Mode.............................16 SECURITY CODES AND AUTHORITY LEVELS (CONT’D) ...................................17 To Add a User...........................................17 SECURITY CODES AND AUTHORITY LEVELS (CONT’D) ...................................18 SECURITY CODES AND AUTHORITY LEVELS (CONT’D) ...................................19 To Change a User's Code ........................19 To Delete a User.......................................19 ACCESSING OTHER PARTITIONS............20 To Access another Partition .....................20 Global Arming ...........................................20 Master Keypad Operation.........................22 ACCESSING OTHER PARTITIONS (CONT’D)..................................................23 Common Lobby Operation .......................23 ACCESSING OTHER PARTITIONS (CONT’D)..................................................24 How User Codes Affect the Common Lobby ........................................................24 CHECKING FOR OPEN ZONES .................25 Using the . READY Key ......................25 DISPLAYING ALL ZONE DESCRIPTORS........................................26 Using the . READY Key ......................26 BYPASSING PROTECTION ZONES ..........27 Using the 6 BYPASS Key ....................27 Quick Bypass............................................28 Displaying Bypassed Zones .....................28 ARMING PERIMETER ONLY ......................29 (WITH ENTRY DELAY ON) .........................29 Using the 3 STAY key..........................29 ARMING PERIMETER ONLY ......................30 ARMING PERIMETER ONLY ......................30 Using the 7 INSTANT Key ...................30 ARMING ALL PROTECTION.......................31 Using the 2 AWAY Key........................31
–3–
ARMING ALL PROTECTION....................... 32 Using the 4 MAXIMUM Key................. 32 DISARMING AND SILENCING ALARMS.... 33 Using the 1 OFF Key ........................... 33 Memory of Alarm ...................................... 33 USING THE KEYSWITCH ........................... 34 General..................................................... 34 Arming ...................................................... 34 Disarming ................................................. 34 CHIME MODE.............................................. 35 Using the 9 Key ................................... 35 VIEWING ALARM COMPANY MESSAGES ............................................. 36 General Information.................................. 36 PANIC KEYS................................................ 37 (FOR MANUALLY ACTIVATING SILENT AND/OR AUDIBLE ALARMS) .................. 37 Using Panic Keys ..................................... 37 SPEED KEY (MACROS) ............................. 38 General Information.................................. 38 Defining .................................................... 38 Executing.................................................. 39 ACCESS DOOR CONTROL........................ 40 General Information.................................. 40 Executing.................................................. 40 USING #70 RELAY MENU MODE .............. 41 General Information.................................. 41 USING SCHEDULES................................... 42 Delaying the Closing Time ....................... 42 Temporary Open/Close Schedules .......... 42 USING SCHEDULES (CONT’D).................. 43 Programming Temporary Schedules ....... 43 USING SCHEDULES (CONT’D).................. 44 PROGRAMMING DEVICE TIMERS ............ 45
General Information.................................. 45 PROGRAMMING DEVICE TIMERS (CONT’D).................................................. 46 EVENT LOG PROCEDURES ...................... 47 General Information.................................. 47 To Display the Event Log ......................... 47 EVENT LOG PROCEDURES (CONTINUED).......................................... 48 TESTING THE SYSTEM (TO BE CONDUCTED WEEKLY) ......................... 49 Using the 5 TEST Key ......................... 49 Testing Your System ................................ 49 FIRE ALARM SYSTEM................................ 50 In Case Of Fire Alarm............................... 50 Silencing a Fire Alarm .............................. 50 Typical Trouble Displays .......................... 51 Power Failure ........................................... 52 Non-Alpha Keypad Displays..................... 52 Recommendations for Smoke and Heat Detectors ......................................... 53 Recommendations for Proper Intrusion Protection ................................................. 54 EMERGENCY EVACUATION ..................... 55 MAINTAINING YOUR SYSTEM .................. 56 Taking Care of Your System .................... 56 Replacing Batteries in Wireless Sensors .................................................... 56 Silencing Low Battery Warning Tones at the Keypad ........................................... 57 Routine Care ............................................ 57 QUICK GUIDE TO SYSTEM FUNCTIONS............................................. 58 SUMMARY OF AUDIBLE NOTIFICATION ........................................ 60 INDEX .......................................................... 65
–4–
System Overview
General
Your Honeywell security system consists of a main control panel, at least one keypad, and various sensors strategically positioned throughout the premises. The system offers you three forms of protection: burglary, fire and emergency. The keypad provides full control of system operation. The system uses microcomputer technology to monitor all protection zones and system status and provides appropriate information for display on the keypad(s) used with the system, and initiates appropriate alarms. Your system may also have been programmed to automatically transmit alarm or status messages over the phone lines to a central alarm monitoring station. This manual is designed to help you become comfortable operating your system. Each function is explained in step-by-step detail. We recommend you read the SYSTEM OVERVIEW section to become familiar with the terminology and the basic features of the system.
A Partitioned System
Simply stated, a partitioned system shares one physical alarm system among different users, each with their own requirements. For the most part, you as a user need not know about other users and their structure in the system, but from time to time, you may see display messages that indicate the system is in use by another user. Do not be concerned, this is normal. Refer to the ACCESSING OTHER PARTITIONS section for additional information.
Zones
Your system's sensing devices have been assigned to various "zones." For example, the sensing device on your Entry/Exit door may have been assigned to zone 01, sensing devices on windows in the master bedroom to zone 02, and so on. These numbers will appear on the display, along with an alpha descriptor for that zone (if programmed), when a fault, alarm or trouble condition occurs.
–5–
System Overview (cont’d)
Fire Protection
The fire protection portion of your security system (if used) is always on and will sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM section for important information concerning fire protection, smoke detectors and planning emergency exit routes from your house.
Burglary Protection
The burglary protection portion of your system must be turned on or "armed" before it will sense burglary alarm conditions. Your system provides four modes of burglary protection: STAY, AWAY, INSTANT and MAXIMUM, and even allows you to BYPASS selected zones of protection while leaving the rest of the system armed. The system also provides a CHIME mode, for alerting users to the opening and closing of doors and windows while the system is disarmed. Refer to the other sections of this manual for procedures for using these features. The following table lists the four different arming modes and the results of each. Features For Each Arming Mode Exit Entry Perimeter Delay Delay Armed Yes Yes Yes Yes Yes Yes Yes No Yes Yes No Yes
Arming Mode AWAY STAY. INSTANT. MAXIMUM
Alarms
When an alarm occurs, both the keypad and external sounders will sound, and the keypad will display the zone(s) causing the alarm. If your system is connected to a central monitoring station, an alarm message will also be sent. To stop the alarm sounding, simply disarm the system.
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the zone(s) that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It remains displayed until it is cleared by disarming the system (see DISARMING THE SYSTEM section).
–6–
System Overview (cont’d)
Speed Key (Macros)
The system can store a string of up to 16 keystrokes, which can be activated anytime by simply pressing the “D” key. This feature can be used to make it easy to perform multiple functions at once (such as going to another partition to bypass a zone), or it can be used to simplify an everyday, repeated procedure. Refer to the SPEED KEY section for procedures for using this feature.
Using Schedules
Your system may have been programmed with schedules for automatically arming, disarming and activating various devices and/or performing other system functions at predetermined times. Users can modify some of these schedules by manually delaying a closing time, using temporary schedules, or by programming special user schedules. Refer to the USING SCHEDULES section at the end of this manual for scheduling related procedures.
Device Timers
The system provides up to 20 "timers" that can be used to control various devices, such as lights or appliances. These timers are similar in concept to the individual appliance timers that might be purchased at a department store. The devices that can be controlled are programmed into the system by the installer. Up to 16 of these devices can be programmed. Refer to the PROGRAMMING DEVICE TIMERS section for procedures.
To Access another Partition (GOTO Command)
Each keypad is assigned a default partition for display purposes, and will show only that partition's information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in another partition, by using the GOTO command. Note that only those partitions authorized and programmed by the installer can be accessed in this manner. To GOTO another partition, enter your security code, then press [.] followed by the desired partition number (1-8). The keypad will remain in the new partition until directed to go to another partition, or until 2 minutes has elapsed with no keypad activity. Entering your security code, pressing [.] followed by [0] will return the keypad to its original partition.
–7–
System Overview (cont’d)
Master Keypad Operation
A "Master" keypad is one on which the status of all 8 partitions is displayed simultaneously. A user can get more information about a certain partition by simply entering [.] + the desired partition number (1-8). To log on to the "Master" partition (9) using the GOTO command, and to perform any functions at a Master keypad, a user must have access to all partitions.
Self-Help Feature
Abbreviated user's instructions are built into the system that can be easily viewed on the alpha keypad's message display screen. This feature will prove particularly useful if this manual is not conveniently accessible when you need to perform a system procedure with which you are not familiar. To view the abbreviated instructions: Simply press and hold down the function key of interest until the description starts to appear (about 5 seconds) and then release it. The system must be “READY TO ARM” to perform this function. Refer to the FUNCTIONS OF THE KEYPAD section for descriptions of each key function.
Phone Access & Voice Response Capability
Your system may include a 4286 VIP module that will permit you to access the system via a Touch-tone phone, either on-premises or by call-in when away. The phone access feature will enable you to do the following: • Receive synthesized voice messages over the telephone regarding the status of the security system. • Arm and disarm the system and perform most function commands via the telephone, with voice confirmation provided after each command entry. • Control 4204/4204CF relays devices and lights and appliances through the #70 Manual Relay Activation mode. Complete information regarding the use of this feature is provided in a separate manual entitled PHONE ACCESS USER’S GUIDE, which accompanies the 4286 VIP module.
–8–
About The Keypads
General
IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a safe location nearby. Your keypads allow you to control all system functions. The keypads feature a telephone style (digital) keypad and a Liquid Crystal Display (LCD) that shows the nature and location of all occurrences. Keypad display back lighting is programmable to always stay on or to light only when a key is pressed, then turn off a few minutes later. The keypads also feature a built-in sounder that will sound during alarms and troubles. It will also "beep" during certain system functions, such as during entry/exit delay times, during CHIME mode, and when depressing keys to perform system functions (to acknowledge the key press). These sounds can be optionally suppressed in some of your keypads (so as not to disturb other users of the system). Ask your installer if this has been done.
The Alpha Keypad
Alpha keypads feature a 2-line, 32 character alphanumeric Liquid Crystal Display (LCD) that can display system messages in user-friendly English. Abbreviated user's instructions can also be displayed (see Self Help paragraph in the SYSTEM OVERVIEW section). These keypads can also be programmed with custom zone descriptors.
–9–
Functions of the Keypad
LCD DISPLAY
SPEAKER
ARMED
LEDS
READY
A B C D
1 4 7
OFF
2 5 8 0
AWAY
3 6 9 #
STAY
MAX
TEST
BYPASS
INSTANT
CODE
CHIME
READY
FUNCTION KEYS
IMPORTANT! When using the keypad to enter codes and commands, sequential key depressions must be made within 3 seconds of one another. If 3 seconds elapses without a key depression, the entry is aborted and must be repeated from its beginning.
– 10 –
6160-00-002-V1
Functions of the Keypad (cont’d)
ALPHA DISPLAY WINDOW: A 2-line, 32-character Liquid Crystal Display (LCD) that displays protection point identification and system status, messages, and user instructions. 1 OFF : Disarms the burglary portion of the system, silences alarms and audible trouble indicators, and clears visual alarm trouble after the problem has been corrected. 2 AWAY : Completely arms both perimeter and interior burglary protection by sensing an intruder's movements through protected interior areas as well as guarding protected doors, windows, etc. Late arrivals can enter through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. 3 STAY : Arms the perimeter burglary protection, guarding protected doors, windows and other perimeter protection points, and sounds an alarm if one is opened. Also allows automatic bypassing of certain areas which permits movement within your house without causing an alarm. Late arrivals can enter through an entry delay zone without causing an alarm if the system is disarmed before the entry delay time expires. See ARMING PERIMETER ONLY for a full explanation of the STAY key. 4 MAXIMUM : Arms in manner similar to AWAY mode, but eliminates the entry delay period, thus providing maximum protection. An alarm will occur immediately upon opening any protection point, including entry delay zones. 5 TEST : Tests the system and alarm sounder if disarmed. 6 BYPASS : Removes individual protection zones from being monitored by the system. Displays previously bypassed protection zones. 7 INSTANT : Arms in manner similar to STAY mode, but turns off the entry delay period, offering greater security while inside and not expecting any late arrivals. An alarm will occur immediately upon opening any perimeter protection point, including entry delay zones. 8 CODE : Allows the entry of additional user codes that can be given to other users of the system.
–11 –
Functions of the Keypad (cont’d)
9 CHIME : Turns on & off the CHIME mode. When on, any entry through a protected delay or perimeter zone while the system is disarmed will cause a tone to sound at the Keypad(s). . READY : When depressed prior to arming the system, the keypad will display all open protection zones within the keypad's home partition. This key is also used to display all zone descriptors that have been programmed for your system, by holding the key down for at least 5 seconds. # : Permits ARMING of the system without use of a security code ("Quick Arm", if programmed). KEYS 0-9: Used to enter your individual security access code(s). LED READY INDICATOR: (GREEN) Lit indicates system is ready to be armed, while unlit indicates system not ready. LED ARMED INDICATOR: (RED) Lit when the system has been armed (STAY, AWAY, INSTANT or MAXIMUM). SPEAKER: Source of audible internal warning and confirmation sounds, as well as alarms (see "Summary of Audible Notifications"). FUNCTION KEYS: These keys can be used for Speedkey (macros) functions or panic keys. Refer to the SPEEDKEY (MACROS) and PANIC KEYS sections for descriptions of these functions.
– 12 –
Entry/Exit Delays
General Information
Your system has installer-programmed time delays, known as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period. Entry Delay gives you time to disarm the system when you reenter through the designated entrance door. But the system must be disarmed before the entry delay period ends, or an alarm will occur. The keypad will beep during the entry delay period, reminding you to disarm the system. You can also arm the system with no entry delay at all by using either INSTANT or MAXIMUM arming modes. These modes provide greater security while on the premises or while away for extended periods of time. See your installer for your delay times.
–13 –
Security Codes and Authority Levels
General Information
At the time of installation, you were assigned an authority level and a personal four-digit security code, known only to you and yours. The security code must be entered when arming and disarming the system. The authority level defines the system functions that you can perform. As an additional safety feature, other users that do not have a need to know your code can be assigned different security codes, and each user can be given a different authority level. Users are identified by "user numbers", which are assigned when assigning a user's security code. All codes can be used interchangeably when performing system functions within the limits of each code's authority level (a system armed with one user's code can be disarmed by another user's code), with the exception of the Operator Level C code. See AUTHORITY LEVELS on the following page for details regarding authority levels.
Duress Code
This feature is intended for use if you are forced to disarm or arm the system under threat. When used, the system will act normally, but can silently notify the central station of your situation, if that service has been provided. The duress code is pre-assigned by the installer during installation (authority level 6). Important: This code is useful only when the system is connected to a central station.
Quick Arming
Note that if "Quick Arming" was programmed by the installer, the [#] key can be pressed in place of the security code when arming the system. The security code must always be used to disarm the system, however.
– 14 –
Security Codes and Authority Levels (cont’d)
Authority Levels
Authority levels define the system functions a particular user can perform. Depending on the authority assigned to you, there are certain system functions you may be prohibited from performing. In summary, there are six authority levels, each having certain system restrictions as shown below. Level 1 Master: Can perform all system functions in assigned partitions, and can add, delete or change Manager and Operator level users. Master codes are added by the Installer. Level 2 Manager: Can perform system functions in assigned partitions, and can add, delete or change Operator level users. Level 3 Operator A: Can perform system functions in assigned partitions, but cannot add or delete other users. Level 4 Operator B: Same as Operator A, except Operator B cannot bypass zones of protection. Level 5 Operator C: Can arm the system in assigned partitions, but cannot disarm the system unless the system was armed with this code. This code is typically assigned to someone who has a need to arm/disarm the system only at certain times (such as a baby-sitter). Level 6 Duress: Can arm and disarm the system, but also sends a silent panic alarm to the central station, if that service is connected. To view your authority level and system capabilities: 1. Enter your code + [.] + [.]. 2. The keypad will display the partition(s) that you are authorized to operate, and your user number and authority level in each partition.
–15 –
Security Codes and Authority Levels (cont’d)
General Rules on Authority Levels and Changes
• A user may not delete or change the user code of the SAME or HIGHER authority than which he is assigned. • A user may only ADD users to a LOWER authority level. • A user may assign access codes only to those partitions to which the user adding the code has access. (Ex. a user with access to only partition 1 cannot assign codes in partition 2.) • The only way to assign a user's authority level is by using the "Add a User" procedure. To change a user's authority level, that user must first be deleted, and then added again. • A user can only be DELETED or CHANGED from within the partition he is assigned. • User numbers must be entered as 2-digit entries. Single digit user numbers must be preceded by a "00" (example, 03, 04, etc.). Security codes are entered as 4-digit numbers. • Before assigning a security code, be sure it does not conflict with any DURESS code. Note: When adding, changing or deleting users, all other alpha keypads in that partition will display "User Edit Mode – Please Stand By", and key depressions (except Panic) at those keypads will be ignored. Panic key depressions will cause an alarm and terminate user entry.
To Exit User Edit Mode
You can exit any of the user edit modes described on the following pages at any time by doing the following: 1. Press either . or # , or don't press any key for 10 seconds. 2. System returns to normal mode.
– 16 –
Security Codes and Authority Levels (cont’d)
To Add a User
IMPORTANT: Temporary users should not be shown how to use any system function they do not need to know (e.g. bypassing protection zones). CODE 1. Enter Master or Manager code and press the 8 key. 2. Enter the new user's 2-digit User Number (02-75). 3. Enter 4-digit security code for that user. The following prompts will appear. Enter 1 to add a new user code. Entering 0 will ADD NEW USER? change the existing user's code to the code entered 0 = NO , 1 = YES in step 3. See Changing A User's Code section.
USER NUMBER = 03 ENTER AUTH. LEVEL
Enter the authority level, 1-6, for this user within this partition. 1=master 2=manager 3=operator A 4=operator B 5=operator C 6=duress code If access schedules have been programmed, this prompt appears. Enter the user's access group number (1-8) if this user should have limited access to the system. Enter 0 if no access group should be assigned. This prompt will appear if a 5800 series button transmitter has been supplied and has not yet been assigned to a user. Press 1 if a button transmitter will be assigned to this user. Otherwise press 0. If assigning a button transmitter, this prompt will appear. Enter the button's zone number (see your installer for zone number).
ACCESS GROUP? ENTER 0-8
RF BUTTON ? 0 = NO , 1 = YES
ENTER BUTTON ZN # (01-86)
–17 –
Security Codes and Authority Levels (cont’d)
MULTI-ACCESS ? 0 = NO , 1 = YES
If you as a user have access to other partitions, the keypad will prompt for ability of this new user to access (GOTO) those partitions. Press 0 (NO) or 1 (YES). If no, the system activates this user code and exits “Add a User” mode. If yes, the keypad prompts for the Global Arm option for this user. Press 1 (YES) if this user will be allowed to try to arm more than one partition at the same time. Press 0 if this user will arm only his assigned partition. The keypad now prompts for the user’s access to the next partition (see GOTO command). Again press 0 or 1. If yes, the system will automatically assign a user number for use in that partition and will prompt for authority level and global arm options for this user within the partition (see previous steps). When all partitions have been displayed, the keypad will scroll through the partition(s) to which access has been assigned, and will display the user number, authority level and global arm option for each. The “G” after the authority level indicates that the global arm feature is active for this user in the displayed partition. The "*" indicates the partition from which this user can be changed or deleted. The "." at the end of the second line indicates that this user sends open/close reports. Open/close reporting is automatically active for any users added by you, if you have open/close reporting active.
GLOBAL ARM ? 0 = NO , 1 = YES
PART.2 - SHOP? 0 = NO , 1 = YES
PART. 1 A0* WHSE USER 03 AUTH=3G.
– 18 –
Security Codes and Authority Levels (cont’d)
To Change a User's Code
CODE
1. Enter Master or Manager code and press the to be changed. 2. Enter the new code for that user.
ADD NEW USER? 0 = NO , 1 = YES
8
key + user number
USER 02 CHANGED SUCCESSFULLY
The system will recognize that the user number is already in use and will prompt whether or not this is a new user. Enter 0 to change the existing user's code to the code entered in step 3. The system will confirm that the change is allowed based on authorization level, and if so, will put the new code into effect. Note that if changing one’s own code, the system will prompt for the new code to be reentered. This prevents accidentally changing one's own code.
To Delete a User
CODE
1. Enter Master or Manager code and press the to be deleted. 2. Enter Master or Manager code first entered.
OK TO DELETE 0 = NO , 1 = YES USER CODE DELETED
8
key + user number
The system will recognize that the User number is already in use and will prompt to confirm that it should be deleted. Press 0 (NO) or 1 (YES). If yes, that user's code will be removed from all partitions to which it was assigned, and all authorization levels and other information about that user will be deleted. Note that a user can only be deleted from the partition in which it was first assigned, and can only be deleted by a user with a higher authority level. A User's security code cannot be deleted by oneself.
–19 –
Accessing Other Partitions
To Access another Partition
Each keypad is assigned a default partition for display purposes, and will show only that partition's information. But, if the user is authorized, a keypad in one partition can be used to perform system functions in other partitions by using the GOTO command. Note that only those partitions authorized and programmed by the installer can be accessed in this manner. To GOTO another partition:
READY
1. Enter your security code, then press
.
+ partition number (0-8).
Entering partition number 0 will return the keypad to its original partition. The keypad will remain in the new partition AAAA 2. LOG-ON TO PART. X COMPLETE until directed to go to another partition, or until 2 minutes has elapsed with no keypad activity. AAAA = alpha descriptor programmed by the installer X = partition number
Global Arming
The Global Arming option may be assigned for use by some users. If Global Arming was enabled for use with your security code, a keypad prompt (message) shown below appears after pressing one of the arming function keys (STAY, INSTANT, AWAY, MAXIMUM, OFF).
– 20 –
Accessing Other Partitions (cont’d)
Global Arming Notes:
• When performing a Global Arm, if there are faults in any of the selected partitions, the system will enter a Summary Mode. Faulted zones in all the selected partitions will be displayed. These faults must be corrected or bypassed. This Summary Mode will end in approximately 120 seconds if no keys are pressed. When performing a Global Disarm, if any of the selected partitions has a condition which would cause the keypad to beep (e.g., alarm memory or a trouble condition), the system enters a Summary Mode and displays the condition. This Summary Mode will end in approximately 120 seconds if no keys are pressed.
•
–21 –
Accessing Other Partitions (cont’d)
Master Keypad Operation
A "Master" keypad is one that reflects the status of the entire system (Partitions 1-8) on its display. This is useful because it eliminates the need for a security officer in a building to have to "log-on" to various partitions from one partition's keypad to find out where an alarm has occurred. A description of a typical display follows: SYSTEM STATUS 12345678 R R N N A R/ B
The status of each partition is directly below the partition number on the display. Possible status indications include: A = Armed Away S = Armed Stay M = Armed Maximum I = Armed Instant R = Ready N = Not Ready B = Bypassed/Ready / = Alarm To obtain more information regarding a particular partition, enter [/] + [Partition No.] (i.e., /4). This will allow viewing only of that partition. In order to affect that partition, the user must log on with a code that has access to that partition. Also, in order for a user of any partition to log onto the "Master" partition (Partition 9) to view the status of all partitions, and to perform any functions at the Master keypad, that user must have access to all partitions. Otherwise, access will be denied. The following is an example of what would be displayed for a fault condition on Zone 02 (Loading Dock Window) on Partition 1 (Warehouse) when logging on from a keypad on Partition 9: WHSE DISARMED HIT / FOR FAULTS This is the normal display that appears at Partition 1's keypad(s). Pressing / will display: FAULT 02 LOADING DOCK WINDOW
– 22 –
Accessing Other Partitions (cont’d)
Additional zone faults will be displayed one at a time. To display a new partition's status, press / + [Partition No.]. This will display the status of the new partition. The "Armed" LED on a Master keypad will be lit only if all partitions have been armed successfully. The "Ready" LED will be lit only if all partitions are "ready to arm." The sounder on a Master keypad will reflect the sound of the most critical condition on all of the partitions. The priority of the sounds is as follows: A. Pulsing fire alarm sounds B. Steady burglar alarm sounds C. Trouble sounds The sounder may be silenced by pressing any key on the Master keypad.
Common Lobby Operation
When an installation consists of a partition that is shared by users of other partitions in a building, the shared partition may be assigned as a “common lobby” partition for the system. An example of this might be in a medical building where there are two doctors and a common entrance area. This option employs logic for automatic arming and disarming of the common lobby. Partitions may be set to affect and/or attempt to arm the common lobby. This will affect the way the lobby will react when arming or disarming activity occurs in another partition. Partitions that affect the lobby will cause the following to occur: a. When the first partition that affects the lobby is disarmed, the lobby will also be disarmed. b. The common lobby cannot be armed unless every partition selected to affects the lobby is armed. c. Arming the last partition that affects the lobby will not automatically attempt to arm the lobby. Partitions set to arm the lobby will cause the following to occur: a. When the first partition that affects the lobby is disarmed, the lobby will also be disarmed. b. The common lobby cannot be armed unless every partition selected to affects the lobby is armed.
–23 –
Accessing Other Partitions (cont’d)
c. Arming the last partition programmed to arm the lobby will automatically attempt to arm the lobby. If any faults exist in the lobby partition, or another partition that affects the lobby is disarmed, the lobby cannot be armed, and the message “UNABLE TO ARM LOBBY PARTITION” will be displayed. The following chart summarizes how the common lobby partition will operate:
Partition Affects Lobby NO YES YES NO Partition Arms Lobby NO NO YES YES Disarms When Partition Disarms NO YES YES Attempts to Arm When Partition Arms NO NO YES ---ENTRY NOT ALLOWED--Can Be Armed if Other Partitions Disarmed YES NO NO
How User Codes Affect the Common Lobby
Codes with “Global” Arming If your code is given “global arming” when it is defined, the system displays a prompt that allows you to pick and choose the partitions to be armed or disarmed. This eliminates the “automatic” operation of the lobby. Keep in mind, however, that if attempting to arm all the partitions you have access to, and another affecting partition is disarmed, (one you do not have access to) you will not be able to arm the lobby, and the message “UNABLE TO ARM LOBBY PARTITON” will be displayed. Codes with “Non-Global” Arming If arming with a non-global code, the lobby partition operation will be automatic, as described in the previous table. Other Methods of Arming/Disarming When arming or disarming a partition that affects and/or arms the common lobby in one of the following manners, lobby logic remains active: • Quick-Arm • Keyswitch • Wireless Button • Wireless Keypad
– 24 –
Checking For Open Zones
Using the . READY Key
Before arming your system, all protected doors, windows and other protection zones must be closed or bypassed (see BYPASSING section). Otherwise the keypad will display a "Not Ready" message. Using the READY key will display all zones that are faulted, making it easier for you to secure any open zones. To show faulted zones: DISARMED - PRESS / TO SHOW FAULTS Note: Some keypads light a green LED when the system is ready. If not lit, the system is not ready to be armed.
READY
1. Do not enter security code, but simply press
.
.
FAULT 05 FRONT Typical fault display UPSTAIRS BEDROOM
2.
DISARMED READY TO ARM
Secure or bypass the zones displayed before arming the system. The "Ready" message will be displayed† when all protection zones have been either closed or bypassed. † NOTE: All or part of this message may be replaced by a customized message programmed by the installer. Bear this in mind whenever the instructions indicate that the "DISARMED" or "READY" message will be displayed.
–25 –
Displaying All Zone Descriptors
Using the . READY Key
The Alpha Keypads can also display all the zone descriptors that are programmed in your system. The abbreviated instructions for the READY key will appear first, followed by the zone descriptors. Displaying all descriptors is useful when you need to know the zone number of a particular zone, as when bypassing zones. The "Disarmed-Ready to arm" message must be displayed before zone descriptors can be displayed.
READY
Press the
.
key and hold down for at least 5 seconds.
– 26 –
Bypassing Protection Zones
Using the 6 BYPASS Key
This key is used when you want to arm your system with one or more zones intentionally unprotected. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. All bypasses are removed when an OFF sequence (security code plus OFF) is performed. Bypasses are also removed if the arming procedure that follows the bypass command is not successful. Note: The system will not allow fire or emergency zones to be bypassed. To bypass zones, the system must be disarmed first.
BYPASS
1. Enter your security code and press
6
.
2. Enter zone number(s) for the zones to be bypassed (e.g., 01, 02, 03, etc.). Important! All single-digit numbers must be preceded by “0” (for example, enter 01 for zone 1). 3. Press [/] + [/].
4. BYPASS 07 FRONT
UPSTAIRS BEDROOM
Typical bypass message
When finished, the keypad will display the word BYPASS along with each bypassed zone number. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses. Arm the system as usual when the keypad displays "ready" to arm message.
5.
DISARMED BYPASS READY TO ARM
–27 –
Bypassing Protection Zones (cont’d)
Quick Bypass
Your system allows you to easily bypass all open (faulted) zones without having to enter zone numbers individually. NOTE: All bypasses are removed when an OFF sequence (security code plus OFF) is performed. To use the Quick Bypass feature:
BYPASS
1. Enter your security code and press
6
then press # .
2. BYPASS 07 FRONT
UPSTAIRS BEDROOM
Typical bypass message
In a few moments, all open zones will be displayed along with the word BYPASS. Wait for these zones to be displayed before arming. Arming the system before bypassed zones are displayed eliminates all bypasses. Arm the system as usual when the keypad displays the "ready" to arm message. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed.
3.
DISARMED BYPASS READY TO ARM
Displaying Bypassed Zones
For determining what zones have been previously bypassed. Bypassed zones can be displayed only when system is disarmed.
BYPASS
1. Enter your security code and press
6
.
2. Wait for all bypassed zones to be sequentially displayed.
– 28 –
Arming Perimeter Only
(With Entry Delay ON)
Using the 3 STAY key
Use this key when you are staying home, but might expect someone to use the entrance door later. When armed in STAY mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. Late arrivals can enter through the entrance door without causing an alarm, but they must disarm the system within the entry delay period or an alarm will occur. Check with your installer for a list of the zones that are bypassed during STAY mode. Close all perimeter windows and doors CHECKING FOR OPEN ZONES section)
STAY
before
arming
(see
1. Enter your security code and press
3
2.
ARMED ***STAY*** ZONE BYPASSED
The keypad beeps three times, displays the armed message. Note: "ZONE BYPASSED" in this display simply indicates that some zones of protection are not armed when using STAY mode.
–29 –
Arming Perimeter Only
(With Entry Delay OFF)
Using the 7 INSTANT Key
Use this key when you are staying home and do not expect anyone to use the entrance door. When armed in INSTANT mode, the system will sound an alarm if a protected door or window is opened, but you may otherwise move freely throughout the premises. The alarm will also sound immediately if anyone opens the entrance door. Check with your installer for a list of the zones that are bypassed during INSTANT mode. Close all perimeter windows and doors CHECKING FOR OPEN ZONES section)
INSTANT
before
arming
(see
1. Enter your security code and press 7
2.
ARMED *INSTANT* ZONE BYPASSED
The keypad beeps three times and displays the armed message. Note: "ZONE BYPASSED" in this display simply indicates that some zones of protection are not armed when using INSTANT mode.
– 30 –
Arming All Protection
(With Entry Delay ON)
Using the 2 AWAY Key
Use this key when no one will be staying on the premises. When armed in AWAY mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm. You may also reenter through the entrance door, but must disarm the system within the entry delay period or an alarm will occur. Close all perimeter windows and doors CHECKING FOR OPEN ZONES section)
AWAY
before
arming
(see
1. Enter your security code and press
2
.
2.
ARMED **AWAY** YOU MAY EXIT NOW
The keypad will beep twice and will display the armed message. Note: The "YOU MAY EXIT NOW" portion of the message disappears when exit delay expires.
–31 –
Arming All Protection
(With Entry Delay OFF)
Using the 4 MAXIMUM Key
Use this key when the premises will be vacant for extended periods of time such as vacations, etc., or when no one will be moving through protected interior areas. When armed in MAXIMUM mode, the system will sound an alarm if a protected door or window is opened, or if any movement is detected inside the premises. You may leave through the entrance door during the exit delay period without causing an alarm, but an alarm will be sounded as soon as someone reenters. Close all perimeter windows and doors CHECKING FOR OPEN ZONES section).
MAXIMUM
before
arming
(see
1. Enter your security code and press
4
.
2.
ARMED *MAXIMUM* YOU MAY EXIT NOW
The keypad will beep twice and will display the armed message. Note: The "YOU MAY EXIT NOW" portion of the message disappears when exit delay expires.
– 32 –
Disarming and Silencing Alarms
Using the 1 OFF Key
The OFF key is used to disarm the system and to silence alarm and trouble sounds. See "SUMMARY OF AUDIBLE NOTIFICATION" section for information which will help you to distinguish between FIRE and BURGLARY alarm sounds.
IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the keypad will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
To disarm the system and silence burglary or fire alarms:
OFF
1. Enter your security code and press
DISARMED READY TO ARM
1
.
2. The Ready message will be displayed (if no alarms have occurred while armed) and the keypad beeps once to confirm that the system is disarmed.
Memory of Alarm
The keypad displays the zone number and type of alarm for any zone that has an alarm condition. These messages will remain displayed until cleared by a user. If an alarm has occurred, note the zone number displayed on the keypad and repeat step 1 above to clear the "Memory of Alarm" and restore the Ready message display. If the Ready message does not display, go to the displayed zone and remedy the fault (close windows, etc.). If the fault cannot be remedied, notify the alarm agency. If the system was armed when the alarm occurred, repeat step 1 twice: once to disarm the system, a second time to clear the display.
–33 –
Using the Keyswitch
General
Your system may be equipped with a keyswitch for use when arming and disarming a partition. A red and green light on the keyswitch plate indicate the status of your system as follows: Green Light: Lights when the system is disarmed and ready to be armed (no open zones). If the system is disarmed and the green light is off, it indicates the system is not ready (one or more zones are open). Red Light: Lights when system is armed or memory of alarm exists. Lit Steady: Partition is armed in AWAY mode. Slow Flashing: Partition is armed in STAY mode. Rapid Flashing: Memory of alarm, indicating an alarm has occurred.
Arming
To arm in the AWAY mode, turn the key to the right for 1 second and release. Keypads will beep twice and the red light will stay on steady. To arm in the STAY mode, turn the key to the right and hold for longer than 10 seconds, then release. Keypads will RED beep three times and the red light will GREEN flash slowly.
Disarming
To disarm the partition, turn the key to the right and release. If an alarm has occurred, the red light will be flashing rapidly (memory of alarm).
keyswitch-001-V1
– 34 –
Chime Mode
Using the 9 Key
Your system can be set to alert you to the opening of a door or window while it is disarmed by using CHIME mode. When activated, three tones will sound at the Keypad whenever a protected perimeter door or window is opened, and the Not Ready message will be displayed. Pressing the READY key will display the open protection points. Note that Chime mode can be activated only when the system is disarmed. 1. To turn Chime Mode on, enter the security code and press 9 . CHIME MODE ON The CHIME MODE ON message will appear for about 2 seconds then disappear. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds.
2. To turn Chime Mode off, enter the security code and press 9 again. CHIME MODE OFF The CHIME MODE OFF message will appear for about 2 seconds then disappears. To display this message again (to determine whether chime mode is on or off), simply press and hold down the CHIME key for 5 seconds.
–35 –
Viewing Alarm Company Messages
General Information
Users of the system may periodically receive messages on their display screens from their monitoring agency or installer. When a message is waiting to be viewed, the message shown below will appear. MESSAGE. PRESS 0 FOR 5 SECS. 1. Press and hold down 0 key for 5 seconds. 2. The message could take up to four screens to display all the information available. NOTE: Any message sent by the central station downloader may be viewed at any partition’s keypad.
– 36 –
Panic Keys
(For Manually Activating Silent and/Or Audible Alarms)
Using Panic Keys
Your system may have been programmed to use special key combinations to manually activate panic functions. The functions that might be programmed are Silent Emergency, Audible Emergency, Personal Emergency, and Fire. See your installer for the function(s) that may have been programmed for your system.
(Your installer should note which function(s) is active in your system.) Keys Zone Function 1 and * 95 3 and # 96 * and # 99 A 95 B 99 C 96
Active Panic Functions
To use a paired key panic function, simply press both keys of the assigned pair at the same time. If your keypad(s) have lettered keys for panic functions, press the designated key and hold down for at least 2 seconds to activate the panic function.
A silent emergency sends a silent alarm signal to the central station, but there will be no audible alarms or visual displays. An audible emergency sends an emergency message to the central station (if connected) and will sound a loud, steady alarm at your keypad and at any external sounders that may be connected (ALARM plus a zone number would also be displayed). A personal emergency alarm sends an emergency message to the central station (if connected) and will sound at Keypads, but not at external bells or sirens. (ALARM plus a zone number would also be displayed.) A fire alarm sends a fire alarm message to the central station and will uniquely sound external bells and sirens (FIRE plus a zone number would also be displayed).
–37 –
Speed Key (Macros)
General Information
The “D” key can be used to activate a string of commands up to 16 keystrokes each. These commands are known as a macro and are stored in the system’s memory. Typical Speed Key functions include: • Arming sequences that involve first bypassing certain zones before arming. • Seldom used but repeatable sequences. • Relay activation sequences. NOTE: If a speedkey function includes an arming sequence and the user executing it has global arming, all partitions the user can global arm will arm.
Defining
To program a macro, enter your user code + [#] + [D]. The following appears: ENTER SPEED KEY D
Existing sequence displayed
Enter up to 16 keystrokes. A Speed Key sequence can include different commands. Press the "D" key to separate different commands. For example, you may want to perform the following sequence. GOTO partition 2...................... Enter *2 Bypass zones 10 & 11 ............... Press bypass [6], then the zone numbers 10 & 11 Arm in maximum mode............ Press maximum [4] key Return to partition 1 ................ Enter *1 To program that Speed Key sequence, type the following: *2 D 6010011 D 4 D *1 D D Note that the "D" key is pressed after each command. Press "D" twice to complete the entry and exit. NOTE: When defining Speed Key sequences, do not use the [#] key to represent Quick Arming. The system uses the code entered in response to the prompt to initiate commands in a Speed Key sequence, so the quick arm key is unnecessary. The system interprets the use of the [#] key in a Speed Key sequence as its designated function only.
– 38 –
Speed Key (Macros) (cont’d)
Executing
To activate a Speed Key, press and hold down the [D] key for 2 seconds. If a user code is required for any part of the Speed Key sequence, the following prompt appears. Otherwise, the Speed Key sequence automatically begins. ENTER USER CODE //// Enter your user code. automatically. The programmed Speed Key sequence will begin
– 39 –
Access Door Control
General Information
Your system may be set up such that a locked access door (such as in a lobby) can be unlocked momentarily or for a specific period of time, using a keypad command. Ask your installer if this has been done in our system.
Executing
There are several entries that can be entered at the keypad to activate this command: 1. Enter your security code + [0]. The door will unlock for 2 seconds.
– 40 –
Using #70 Relay Menu Mode
General Information
Your system may be set up so that certain lights or other devices can be turned on or off by using the #70 command from either a keypad or a telephone keypad (if 4286 VIP module is used). Ask your installer if this has been done in your system. To activate relays from a keypad, enter 4-digit security code + [#] +70. Follow the keypad prompts described below. To activate relays using a telephone and 4286 VIP module, first dial the 2-digit phone access code. When the system acknowledges the access, enter 4-digit security code + [#] + 70. The following prompts/voice responses will begin. ENTER DEVICE NO. 00=QUIT 01 Voice: "ENTER DEVICE CODE NOW" Enter the 2-digit number of the device to be activated. Note that if an invalid number is entered, the system will simply ask you to reenter the number. Voice: "voice descriptor DEVICE nn ON/OFF. FOR voice descriptor ON ENTER 1, FOR voice descriptor OFF ENTER 0" Press 0 or 1 to turn the device off or on respectively. "nn" represents the 2-digit device number and voice descriptor is the relay voice descriptor programmed by the installer. NN DEVICE IS OFF HIT THE "/" KEY Voice: "voice descriptor DEVICE nn ON/OFF. TO EXIT ENTER 00 NOW" From a keypad, press / to continue. The ENTER DEVICE NO. prompt will appear. From a telephone keypad, enter 00 to exit, or enter the next relay number to be programmed. The current on/off state of that relay will be annunciated as described above. Alternatively, if 6 seconds elapses with no key depression, the 4286 VIP module will annunciate the "ENTER DEVICE CODE NOW" message.
NN DEVICE IS OFF HIT 0=OFF , 1=ON
– 41 –
Using Schedules
Delaying the Closing Time
Your system's programmed schedules may automatically arm the system at a predetermined time. In the event a user must stay on the premises later than usual, users with master or manager authority levels can manually delay the automatic arming (closing) time up to 2 hours. To delay the closing time: 1. Enter your security code (master or manager authority levels only). 2. Press the # key, followed by 82. 3. A menu prompt will be displayed, asking for the number of hours of delay. CLOSING DELAY? KEY 0-2 HOURS Enter the desired number of hours of delay, 1 or 2. The system automatically exits this mode after entry.
Note that the delay is from the scheduled closing time, not from the time the command is entered. IMPORTANT: The selected delay cannot be reduced once it is set. A 1 hour delay can be increased to 2 hours, though. 4. The system will automatically send a message to the central station informing them that the programmed schedule has been changed.
Temporary Open/Close Schedules
Temporary schedules allow you to override the normal schedules programmed by the installer. Temporary schedules can be in effect for up to one week, and take effect as soon as they are programmed. They are comprised of an arming (closing) time window and a disarming (opening) time window. A time window is simply a defined period of time, at the end of which arming or disarming will occur. Before programming, use a worksheet similar to the one below to plan your schedule. This will make it easier when actually programming the schedule.
Arm/Disarm Windows Disarm Window Start Time Stop Time Arm Window Start Time Stop Time HH:MM HH:MM HH:MM HH:MM Mon Tue Wed Thu Fri Sat Sun
– 42 –
Using Schedules (cont’d)
Programming Temporary Schedules
Temporary schedules only affect the partition from which it is entered. Temporary schedules can be reused at later dates simply by scrolling (by pressing #) to the DAYS? prompt (described below) and activating the appropriate days. This should be considered when defining daily time windows. Note that only users with authority level of manager or higher can program temporary schedules. To program temporary schedules: 1. Enter your security code. 2. Press the # key followed by 81. 3. The following prompts will appear. MON DISARM WIND. 07:45AM 08:45AM The cursor will be positioned on the tens of hours digit of the start time for Monday's disarm window. Enter the desired hour. Press * to move to the minutes field. The minutes are entered in the same manner. The AM/PM indication is changed by hitting any key, 0-9, while the cursor is under the letter A/P position. Repeat for the stop time entry. Press the * key to move to the arming window for Monday. Press # to move to the next screen display without making changes. The cursor will be positioned on the tens of hours digit of the start time for the arm window. Repeat the previous steps to enter the start and stop time for Monday's arming window. After the windows for that day have been completed, the system will prompt for disarm and arm time windows for the next day. Repeat the procedure for all days of the week. When all of the days have been completed, the system will ask which days are to be activated.
MON ARM WINDOW 07:45AM 08:45AM
TUE DISARM WIND. 07:45AM 08:45AM
– 43 –
Using Schedules (cont’d)
DAYS ? MTWTFSS HIT 0-7 X X This is the prompt that actually activates the temporary schedule, and allows the temporary schedule to be customized to a particular week's needs. To select the days which are to be activated, enter the desired number 1-7 (Monday = 1). An "X" will appear under that day, indicating the previously entered schedule for that day is active. Entering a day's number again will deactivate that day. Pressing 0 will turn all days on/off. The temporary schedule will only be in effect for the days which have the letter x underneath them. As the week progresses, the days are reset to the inactive state. When completed, press * to exit the temporary schedule entry mode.
– 44 –
Programming Device Timers
General Information
Device timers consist of an ON time & an OFF time, and selected days of the week in which they are active. There are up to 20 timers that can be used to control various devices, such as lights or appliances. Your installer will have programmed the appropriate devices into the system (up to 96 devices can be programmed). Each timer controls a single device (designated as an output number) that you select. For example, timer 1 might be set to turn the porch lights on at 7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air conditioner Monday-Friday at 4:30pm to cool the premises before you arrive at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If desired, different timers can control the same device. For example, timer 2 could be used Monday-Friday as in the previous example, and timer 3 could be set to turn the air conditioner on and off at different times Saturday and Sunday. To enter the device timer menu mode: Enter your security code, then press the # key followed by 83. OUTPUT TIMER # ? 01-20,00=QUIT 01 Up to 20 timers can be programmed. Each timer is identified by a number 1-20. Enter the desired timer number to be programmed (1-20). Press * to accept entry. If that timer number has already been programmed, a summary screen will appear. In this example: 06 = Timer # 04 = Output Device # affected by this timer PORCH LITE = Output Descriptor for Device 4 07:00PM = Start Time; 11:45PM = Stop Time Press * to continue. Enter the desired output device number (1-96). As the number is entered, the device's description will appear. To delete a previously programmed timer, enter 00 as the output number. – 45 –
06 07:00P 11:45P PORCH LITE 04
See your installer for device numbers.
00 ENTER OUTPUT# 00
Programming Device Timers (cont’d)
00 ON TIME ? 00:00 PM Enter the time you want the device turned on using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something ON for the days selected below. (Ex. using one timer to turn lights on one day and using another timer to turn them off on another day). Enter the time you want the device turned off using 00:01 - 11:59 format. When the display shows the desired time, press the * key to move to the AM/PM field. Press any key 0-9 to change the AM/PM indication. Enter 00:00 if this timer is not being used to turn something OFF for the days selected below. (Ex. using one timer to turn lights on one day and using another timer to turn them off on another day). Select the days on which the device is to be activated by entering 1-7 (Monday = 1). An "X" will appear under that day, indicating the output for that day is active. Entering a day's number again will deactivate that day. Pressing 0 will turn all days on/off. The outputs will only be in effect for the days that have the letter x underneath them. As the week progresses, the days are reset to the inactive state, unless the permanent option is selected (next screen prompt). When completed, press * to continue. Answering 1 (YES) means the system executes this timer continuously. Answering 0 (NO)means the system executes each day's output only once.
00 OFF TIME ? 00:00 PM
00 DAYS? MTWTFSS HIT 0-7 X X
00 PERMANENT ? 0 = NO, 1 = YES 0
– 46 –
Event Log Procedures
General Information
The system has the ability to record various events in a history log wherein each event is recorded in one of five categories (listed below), with the time and date of its occurrence. The Event Log holds up to 224 events, with the oldest event being replaced by the logging of any new event after the log is full. Using an alpha keypad, the Event Log can be viewed one category at a time, or can display all events, regardless of category (ALL EVENT LOG). The system also allows selection of displaying the COMPLETE log, or only those events occurring since the last installer service (RECENT). In addition, events in the other partitions can be viewed by users authorized to access those partitions. Note that events are displayed in chronological order, from most recent to oldest. To Display the Event Log 1. Enter CODE + [#] + [6] + [0] 2. Select the display mode. RECENT: Displays only those events occurring since last Event Log Clear command was executed. COMPLETE: Displays complete event log (up to 224 events). Press the desired key, 0 or 1. ENTER 0 = RECENT 1 = COMPLETE 3. Select the partition, 0-8. Enter the partition number for the partition whose events are to be displayed. Entering 0 (NO) will display all partitions' events. SCAN LOG BY PART 0 = NO 1-8 = PART# 4. Use the [3] & [1] keys (for next and previous categories respectively) to display the categories of events. Press [8] to select a category and display the first event. Press [8] again for each subsequent event. Shows burglary alarm occurred in zone 3 (C03) of partition 1 (P1), at 12:02AM on January 1. P1 01/01 12:02AM BURGLARY C03
Typical Event Log Display
– 47 –
Event Log Procedures (continued)
After the last event has been displayed, the END OF EVENT LOG message appears for a few seconds, then the system automatically displays the RECENT/COMPLETE mode select screen again (see step 2). 5. To EXIT the Event Log: Press [,] at any time. ALARM EVENT LOG TYPE CCC UUU
Typical Category Select Screen
ALARM EVENT LOG Displays time and date for zones that has either caused an alarm or has been restored in the selected partition. CHECK EVENT LOG Displays time and date for zones that has caused a trouble or supervisory condition in the selected partition. BYPASS EVENT LOG Displays time and date for zones that has been bypassed in the partition. OPEN EVENT LOG Displays time, date and user number or 6-character descriptor for the user, if programmed, for each arming and disarming of the system for the partition selected. SYSTEM EVENT LOG Displays time and date for system problems, such as AC Loss, low battery, etc., regardless of partition. ALL EVENT LOG Displays all categories of events in chronological order. See your Installer for additional information concerning the event log.
– 48 –
Testing the System (To Be Conducted Weekly)
Using the 5 TEST Key
The TEST key puts your system into Test mode, which allows each protection point to be checked for proper operation. 1. Disarm the system and close all protected windows, doors, etc. READY should be displayed.
TEST
2. 3.
Enter your security code and press the
5
key.
4.
The external sounder should sound for 3 seconds and then turn off. If the sounder does not sound, it may be due to dialer communication activity. Wait a few minutes and try again. If the sounder still does not sound, CALL FOR SERVICE IMMEDIATELY. The keypad will sound a single beep every 15 seconds as a reminder that the system is in Test mode. Each time a protection zone is faulted (opened), the keypad should beep three times. If the sounder does not sound, CALL FOR SERVICE IMMEDIATELY.
NOTES: • No alarm reports will be sent to the central monitoring station while the system is in Test mode.
Testing Your System
1. Open and close each protected door and window in turn and listen for three beeps. Each faulted protection point should appear on the display. 2. Walk in front of any motion detectors (if used) and listen for three beeps as movement is detected (wireless motion detectors have a 3-1/2 minute lockout between trips). Each detector’s should appear on the display when it is activated. 3. Follow the manufacturer's instructions to test all smoke detectors to ensure that all are functioning properly. Each detector should appear on the display when activated. 4. When all protection points have been checked, there should be no zone identification numbers displayed. If a problem is experienced with any protection point (no confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY.
5. Turn off Test mode by entering the security code + the OFF key.
– 49 –
Fire Alarm System
Your fire alarm system (if installed) is on 24 hours a day, providing continuous protection. In the event of an emergency, the smoke and heat detectors automatically send signals to your Control, triggering a loud interrupting sound from the keypad and the optional exterior sounders. FIRE appears at your keypad and remains on until you silence the alarm.
In Case Of Fire Alarm
1. Should you become aware of a fire emergency before your detectors sense the problem, go to your nearest keypad and manually initiate an alarm by pressing the panic key assigned as FIRE emergency (if programmed by the installer) and hold down for at least 2 seconds. 2. Evacuate all occupants from the premises. 3. If flames and/or smoke are present, leave the premises and notify your local Fire Department immediately. 4. If no flames or smoke are apparent, investigate the cause of the alarm. The descriptor of the zone(s) in alarm appears at the keypad.
Silencing a Fire Alarm
1. Silence the alarm by entering your code and pressing the OFF key. To clear the display, enter your code and press the OFF key again 2. If the keypad does not indicate a READY condition after the second OFF sequence, press the READY key to display the faulted zone(s). Be sure to check that smoke detectors are not responding to smoke or heat producing objects in their vicinity. Should this be the case, eliminate the source of heat or smoke. 3. If this does not remedy the problem, there may still be smoke in the detector. Clear it by fanning the detector for about 30 seconds. 4. You can clear the display by entering your code + the OFF key.
– 50 –
Trouble Conditions
Typical Trouble Displays
The word CHECK on the Keypad's display, accompanied by a rapid "beeping" at the Keypad, indicates that there is a trouble condition in the system. To silence the beeping sound for trouble conditions, press any key. • A display of “CHECK” accompanied by a display of "CALL SERVICE" indicates that a problem exists with the system that eliminates some of the protection. CALL FOR SERVICE IMMEDIATELY. A display of “CHECK” accompanied by a display of one or more zone descriptors indicates that a problem exists with those zone(s)*. First, determine if the zone(s) displayed are intact and make them so if they are not. If the problem has been corrected, the display of the zone descriptor(s) and “CHECK” should disappear. If not, key an OFF sequence (Code plus OFF) to clear the display. If the display persists, CALL FOR SERVICE IMMEDIATELY. A display of "COMM. FAILURE" at the Keypad indicates that a failure has occurred in the telephone communication portion of your system. CALL FOR SERVICE IMMEDIATELY. A display of "SYSTEM LO BAT", accompanied by a once per minute "beeping" at the Keypad indicates that a low system battery condition exists. CALL FOR SERVICE IMMEDIATELY. A display of "LO BAT" and a zone descriptor, accompanied by a once per minute "beeping" at the Keypad indicates that a low battery condition exists in the wireless transmitter displayed. CALL FOR SERVICE IMMEDIATELY. A display of "MODEM COMM" indicates that the control is on-line with the central station's remote computer. The control will not operate while on-line.
•
•
•
•
•
– 51 –
Trouble Conditions (cont’d)
Power Failure
If the POWER indicator is off, operating power for the system has stopped and is inoperative. CALL FOR SERVICE IMMEDIATELY. If the POWER indicator is on, but the message "AC LOSS" is displayed, the Keypad is operating on battery power only. If only some lights are out on the premises, check circuit breakers and fuses and reset or replace as necessary. CALL FOR SERVICE IMMEDIATELY if AC power cannot be restored.
Non-Alpha Keypad Displays
The following displays will appear on non-alpha keypads when the associated trouble condition is present: 97 FC = CALL FOR SERVICE = COMM FAILURE
BAT = SYSTEM LOW BATTERY (if no zone number) or LOW BATTERY on a zone (if a zone number shows) CC = MODEM COMM NO AC = AC LOSS
SERVICING INFORMATION Your local Honeywell dealer is the person best qualified to service your alarm system. Arranging some kind of regular service program with him is advisable. Your local Honeywell dealer is: Name: Address: Phone:
– 52 –
Recommendations for Proper Protection
The following recommendations for the location of fire and burglary detection devices help provide proper coverage for the protected premises.
Recommendations for Smoke and Heat Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below. Early warning fire detection is best achieved by the installation of fire detection equipment in all rooms and areas of the household as follows: For minimum protection a smoke detector should be installed outside of each separate sleeping area, and on each additional floor of a multi-floor family living unit, including basements. The installation of smoke detectors in kitchens, attics (finished or unfinished), or in garages is not normally recommended. For additional protection the NFPA recommends that you install heat or smoke detectors in the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and storage rooms, basements and attached garages.
KITCHEN DINING
BEDROOM BEDROOM TV ROOM KITCHEN DINING BDRM
LIVING ROOM BDRM
LIVING ROOM
BEDROOM
BEDROOM
Smoke Detectors for Minimum Protection Smoke Detectors for Additional Protection BEDROOM TO BR Heat-Activated Detectors
BEDROOM
BEDROOM KTCHN GARAGE
LVNG RM BASEMENT
.
CLOSED DOOR
floor_plan-001-V1
– 53 –
Recommendations for Proper Protection (cont’d)
In addition, we recommend the following: ! Install a smoke detector inside every bedroom where a smoker sleeps. ! Install a smoke detector inside bedrooms where electrical appliances (such as portable heaters, air conditioners or humidifiers) are used. ! Install a smoke detector inside every bedroom where someone sleeps with the door partly or completely closed. Smoke could be blocked by the closed door. Also, an alarm in the hallway outside may not wake up the sleeper if the door is closed. ! Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet (12 meters) long. ! Install smoke detectors in any room where an alarm control is located, or in any room where alarm control connections to an AC source or phone lines are made. If detectors are not so located, a fire within the room could prevent the control from reporting a fire or an intrusion.
Recommendations for Proper Intrusion Protection
For proper intrusion coverage, sensors should be located at every possible point of entry to a home or commercial premises. This would include any skylights that may be present, and the upper windows in a multi-level building. In addition, we recommend that radio backup be used in a security system so that alarm signals can still be sent to the alarm monitoring station in the event that the telephone lines are out of order (alarm signals are normally sent over the phone lines, if connected to an alarm monitoring station).
– 54 –
Emergency Evacuation
Establish and regularly practice a plan of escape in the event of fire. The following steps are recommended by the National Fire Protection Association: 1. Position your detector or your interior and/or exterior sounders so that they can be heard by all occupants. 2. Determine two means of escape from each room. One path of escape should lead to the door that permits normal exit from the building. The other may be a window, should your path be impassable. Station an escape ladder at such windows if there is a long drop to the ground. 3. Sketch a floor plan of the building. Show windows, doors, stairs and rooftops that can be used to escape. Indicate escape routes for each room. Keep these routes free from obstruction and post copies of the escape routes in every room. 4. Assure that all bedroom doors are shut while you are asleep. This will prevent deadly smoke from entering while you escape. 5. Try the door. If the door is hot, check your alternate escape route. If the door is cool, open it cautiously. Be prepared to slam the door if smoke or heat rushes in. 6. Where smoke is present, crawl on the ground; do not walk upright. Smoke rises and may overcome you. Clearer air is near the floor. 7. Escape quickly; don't panic. 8. Establish a common meeting place outdoors, away from your house, where everyone can meet and then take steps to contact the authorities and account for those missing. Choose someone to assure that nobody returns to the house — many die going back.
– 55 –
Maintaining Your System
Taking Care of Your System
The components of your security system are designed to be as free of maintenance as possible. However, there are some things you can do to make sure that your system is in reliable working condition. 1. Test your system weekly. 2. Test the system after any alarm occurs (see TESTING THE SYSTEM).
Replacing Batteries in Wireless Sensors
Wireless sensors may not have been used in your security system
Each wireless sensor in your system has a 9-volt or 3-volt battery. The system detects a low battery in any wireless sensor, including smoke detectors, the optional personal emergency transmitter, and the optional portable wireless keypad. (A low battery in a portable wireless keypad is detected as soon as one of its keys is pressed, and the keypad will display 00.) Alkaline batteries provide a minimum of 1 year of operation, and in most units and applications, provide 2–4 years of service. Actual battery life will depend on the environment in which the sensor is used, the number of signals that the transmitter in the sensor has had to send, and the specific type of sensor. Factors such as humidity, high or low temperatures or large swings in temperature, may all lead to the reduction of actual battery life in an installation. If you have a low battery in a wireless sensor, a low battery message is displayed on the keypad. In addition, a battery-operated smoke detector with a low battery also emits a single "chirp" sound once approximately every 20-30 seconds, identifying itself as the smoke detector with the weak battery. If you do not replace a smoke detector's low battery, the smoke detector may sound continuously, as if there were a fire alarm. NOTE: The low battery message comes on as a warning that battery replacement in indicated sensor(s) is due within 30 days. In the meantime, the sensor(s) causing the low battery indication is still fully operational. IMPORTANT: Use only batteries recommended by your installer as replacement.
– 56 –
Maintaining Your System (cont’d)
Silencing Low Battery Warning Tones at the Keypad
The keypad’s warning tones can be silenced by performing an OFF sequence (code plus OFF key), but the Keypad's low battery message display will remain on as a reminder that you have a low battery condition in one or more of your sensors. When you replace the weak battery with a fresh one, the sensor will send a "good battery" signal to the control as soon as the sensor is activated (opening/closing of door, window, etc.), causing the low battery display to turn off. If the sensor is not activated, the display will automatically clear within approximately 1 hour.
Routine Care
• • • Treat the components of your security system as you would any other electrical equipment. Do not slam sensor-protected doors or windows. Keep dust from accumulating on the keypad and all protective sensors, particularly on motion sensors and smoke detectors. The keypad and sensors should be cleaned carefully with a dry soft cloth. Do not spray water or any other fluid on the units.
– 57 –
Quick Guide to System Functions
FUNCTION Check Zones Display All Descriptors Arm System Disarm System Bypass Zones Quick Bypass Chime Mode Test Mode View Messages View User Capabilities GOTO Partition Self-Help Add a User PROCEDURE Press [,]. Press and hold [,] for 5 seconds. Enter code. Press arming key desired (AWAY, STAY, INSTANT, MAXIMUM). Enter code. Press OFF [1]. Enter code. Press BYPASS [6]. Enter zone numbers to be bypassed (use 2-digit entries). Enter code. Press BYPASS [6]. Press [#]. Enter code. Press CHIME [9]. Enter code. Press TEST [5] Press and hold [0] for at least 5 seconds. Enter user's code. Press [,] + [,]. Enter security code. Press [,]. Enter partition number (1-8). 0 returns to default partition. Press and hold any function key for at least 5 seconds. Enter master/manager code. Press CODE [8]. Enter new user's user number. Enter code for that user. Enter authority for that user in this partition (2-5). Follow prompts, 1=Yes, 0=No. Enter master/manager code. Press CODE [8]. Enter user's 2-digit number. Enter new code for that user. Press 0 (No) at prompt. COMMENTS To view faulted zones when is system not ready Displays all alpha descriptors programmed by installer. Arms system in mode selected. Disarms system and silences alarms. Bypassed zones are unprotected and will not cause an alarm if violated. Bypasses all faulted zones automatically. Keypad will sound if doors or windows are violated while system disarmed. Activates alarm sounder and allows sensors to be tested. Message from central station will appear. Displays partitions & authority levels assigned to the user. Allows a user at one keypad to perform functions in another partition, if that user is authorized to do so. Will display abbreviated instructions for the key pressed. Master & Manager level users can add users to the system, each with its own code and authority level.
Change a User's Code
Master & Manager level users can change their own or other users' codes.
– 58 –
Quick Guide to System Functions (cont’d)
FUNCTION Delete a User PROCEDURE Enter master/manager code. Press CODE [8]. Enter user no. to be deleted. Enter master/manager code. Press 1 (Yes) at prompt. Enter security code. Press [#] Enter 71 or 72. Enter security code. Press [#] Enter 70. Enter security code. Enter 0. COMMENTS Master & Manager level users can delete users. A user can only be deleted by a user with higher authority level. Activate output device as programmed. Activate output device manually Activate access relay for current partition.
Control Output Device Access Control
– 59 –
Summary of Audible Notification
(Alpha Display Keypads)
SOUND
LOUD, INTERRUPTED* Keypad & External LOUD, CONTINUOUS* Keypad & External ONE SHORT BEEP (not repeated) Keypad only
CAUSE
FIRE ALARM BURGLARY/AUDIBLE EMERGENCY ALARM a. SYSTEM DISARM b. SYSTEM ARMING ATTEMPT WITH AN OPEN ZONE. c. BYPASS VERIFY
DISPLAY
FIRE is displayed; descriptor of zone in alarm is displayed. ALARM is displayed; descriptor of zone in alarm is also displayed. a. DISARMED/READY TO ARM is displayed. b. The number and descriptor of the open protection zone is displayed. c. Numbers and descriptors of the bypassed protection zones are displayed (One beep is heard for each zone displayed). Subsequently, the following is displayed: DISARMED BYPASS Ready to Arm Opened Zone identifications will appear. LO BAT displayed with description of transmitter.
ONE SHORT BEEP (once every 15 sec.) Keypad only ONE BEEP (every 60 sec.) Keypad only TWO SHORT BEEPS Keypad only THREE SHORT BEEPS Keypad only
SYSTEM IS IN TEST MODE LOW BATTERY AT A TRANSMITTER ARM AWAY OR MAXIMUM
ARMED AWAY or ARMED MAXIMUM is displayed. Red ARMED indicator is lit. a. ARMED STAY ZONE BYPASSED or ARMED a. ARM STAY OR INSTANT INSTANT ZONE BYPASSED is displayed. Red b. ZONE OPENED WHILE SYSTEM IS IN CHIME MODE. ARMED indicator is lit. b. CHIME displayed, descriptor of open protection c. ENTRY WARNING** zone will be displayed if the [,] key is pressed. c. DISARM SYSTEM OR ALARM WILL OCCUR is displayed. a. CHECK displayed. Descriptor of troubled RAPID BEEPING a. TROUBLE Keypad only b. AC POWER LOSS ALERT*** protection zone is displayed. b. AC LOSS displayed (may alternate with other c. MEMORY OF ALARM displays that may be present). c. FIRE or ALARM is displayed; descriptor of zone in alarm is displayed. a. DISARM SYSTEM OR ALARM WILL OCCUR is SLOW BEEPING a. ENTRY DELAY WARNING** Keypad only b. EXIT DELAY WARNING displayed. Exceeding the delay time without (if programmed) disarming causes alarm. b. ARMED AWAY or ARMED MAXIMUM is displayed along with You May Exit Now * If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring. ** Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer. *** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power only).
– 60 –
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to operate the equipment. FCC CLASS B STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • If using an indoor antenna, have a quality outdoor antenna installed. • Reorient the receiving antenna until interference is reduced or eliminated. • Move the radio or television receiver away from the receiver/control. • Move the antenna leads away from any wire runs to the receiver/control. • Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits. • Consult the dealer or an experienced radio/TV technician for help. INDUSTRY CANADA CLASS B STATEMENT ICES-003 Class B Notice - Avis NMB-003, Classe B This Class B digital apparatus complies with Canadian ICES-003. Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. FCC/IC STATEMENT This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une reception indésirable. IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X (CA38A in Canada) telephone wall jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the control/communicator. Doing so will result in the loss of your phone lines. If the regular phone works correctly after the control/communicator has been disconnected from the phone lines, the control/communicator has a problem and should be returned for repair. If upon disconnection of the control/communicator, there is still a problem on the line, notify the telephone company that they have a problem and request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs.
– 61 –
“FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains, among other information, the FCC registration number and ringer equivalence number (REN) for this equipment. If requested, this information must be provided to the telephone company. This equipment uses the following jacks: An RJ31X is used to connect this equipment to the telephone network. The REN is used to determine the quantity of devices which may be connected to the telephone line. Excessive RENs on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total RENs, contact the telephone company to determine the maximum REN for the calling area. If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. If advance notice is not practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe necessary. The telephone company may make changes in its facilities, equipment, operations, or procedures that could affect the operation of the equipment. If this happens, the telephone company will provide advance notice in order for you to make the necessary modifications in order to maintain uninterrupted service. If trouble is experienced with this equipment, please contact the manufacturer for repair and warranty information. If the trouble is causing harm to the telephone network, the telephone company may request you remove the equipment from the network until the problem is resolved. There are no user serviceable components in this product, and all necessary repairs must be made by the manufacturer. Other repair methods may invalidate the FCC registration on this product. This equipment cannot be used on telephone company-provided coin service. Connection to Party Line Service is subject to state tariffs. This equipment is hearing-aid compatible. When programming or making test calls to an emergency number, briefly explain to the dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early morning or late evening.
– 62 –
CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT
NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations. Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas. Caution: User should not attempt to make such connections themselves, but should contact the appropriate electric inspection authority, or electrician, as appropriate. The Load Number (LN) assigned to each terminal device denotes the percentage of the total load to be connected to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the total of the Load Numbers of all the devices does not exceed 100. AVIS L’étiquette du ministère des Communications du Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est conforme à certaines normes de protection, d’exploitation et de sécurité des réseaux de télécommunications. Le ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur. Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’entreprise locale de télécommunications. Le matériel doit également être installé en suivant une méthode acceptée de raccordement. Dans certains cas, les fils intérieurs de l’entreprise utilisés pour un service individuel à la ligne unique peuvent être prolongés au moyen d’un dispositif homologué de raccordement (cordon prolongateur téléphonique interne). L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions énoncées cidessus n’empèchet pas la dégradation du service dans certaines situations. Actuellement, les entreprises de télécommunications ne permettent pas que l’on raccorde leur matériel aux prises d’abonnés, sauf dans les cas precis prévus par les tarifs particuliers de ces entreprises. Les réparations du matériel homologué doivent être effectuées pas un centre d’entretien canadien autorisé désigné par le fournisseur. La compagnie de télécommunications peut demander à l’utilisateur de débrancher un appareil à la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement. Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise en terre de la source d’énergie électrique, des lignes téléphoniques de réseau de conduites d’eau s’il y en a, soient raccordés ensemble. Cette précaution est particulièrement importante dans les régions rurales. Avertissement: L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir recours à un service d’inspection des installations électriques, ou à un électricien, selon le cas. L’indice de charge (IC) assigné à chaque dispositif terminal pour éviter toute surcharge indique le pourcentage de la charge totale qui peut être raccordé à un circuit téléphonique bouclé utilisé par ce dispositif. La terminaison du circuit bouclé peut être constituée de n’importe quelle combinaison de dispositifs, pourvu que la somme des indices de charge de l’ensemble des dispositifs ne dépasse pas 100.
– 63 –
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety of reasons. For example: • Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor or disconnect an alarm warning device. • Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly. • Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the path. • A user may not be able to reach a panic or emergency button quickly enough. • While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death. • Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows. Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can decrease. • Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the other side of closed or partly open doors. If warning devices sound on a different level of the residence from the bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers. • Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders. • Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond appropriately. • This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to last as long as 10 years, the electronic components could fail at any time. The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance. This alarm system should be tested weekly to make sure all sensors and transmitters are working properly. Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and continue to insure their lives and property. We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved ones to learn about these developments.
– 64 –
Index
#70 Command .......................................41 4286 VIP Module...............................8, 41 AC Loss..................................................52 Access Another Partition ................20 Access Door............................................40 Add a User ...........................................17 ADD NEW USER..................................19 Add User Code ......................................16 Alarm .......................................................6 Alkaline Batteries .................................56 Alpha Keypads ........................................9 Armed ......................................................6 ARMED INDICATOR...........................12 Audible Emergency...............................37 Audible Signals ..................................60 Authority Level .....................................14 Authority Levels .............................15, 16 Away ..................................................6, 20 AWAY ....................................................34 AWAY Mode ..........................................31 Battery Life ...........................................56 Burglary...................................................5 Burglary Protection ................................6 Bypass Zones .........................................27 Bypassing ............................................27 Call Service ...........................................51 Change a User's Code .......................19 Change User Code ................................16 CHECK ..................................................51 Chime.................................................6, 35 Closing Time .........................................42 Comm. Failure ......................................51 Common Lobby ..................................23 Delaying Closing Time .....................42 Delete a User ......................................19 Delete User Code ..................................16 Descriptors ............................................26 Device Timers ................................ 7, 45 Disarm .................................................. 33 DOC....................................................... 63 Duress ................................................... 15 Duress Code ....................................... 14 Early warning fire detection ..................... 2 Emergency .............................................. 5 Entry Delay .......................................... 13 Entry/Exit ............................................... 5 Exit Delay ............................................. 13 Exit User Edit Mode ......................... 16 Fire .................................................... 5, 37 Fire Alarm ............................................ 50 Fire Protection........................................ 6 GLOBAL ARM...................................... 18 Global Arming ...................................... 20 Goto ................................................. 18, 20 GOTO Command .................................... 7 Graphic/Touch-Screen Keypad ........ 9, 30 Honeywell Dealer ................................. 52 Instant............................................... 6, 20 INSTANT.............................................. 13 INSTANT Mode.................................... 30 Keypad .................................................... 5 Keypad Back Lighting ........................... 9 Keypads................................................... 9 Keyswitch.............................................. 34 LO Bat................................................... 51 Low Battery .......................................... 56 Low Battery Warning ...................... 57 Macro .................................................... 38 Macros ................................................... 7 Manager ................................................ 15 Master ................................................... 15 Master Keypad............................... 8, 22 Maximum.......................................... 6, 20 MAXIMUM ........................................... 13 – 65 –
MAXIMUM Mode ................................. 32 Memory of Alarm........................... 6, 33 Messages ............................................... 36 Modem Comm ....................................... 51 MULTI-ACCESS .................................. 18 NFPA ..................................................... 53 Night...................................................... 30 Not Ready.............................................. 25 Off .......................................................... 20 OFF........................................................ 33 Open Zones ......................................... 25 Open/Close Schedules ...................... 42 Operator A............................................. 15 Operator B............................................. 15 Operator C............................................. 15 OUTPUT TIMER.................................. 45 Panic Keys .......................................... 37 PANIC KEYS ........................................ 12 Partitioned System ................................. 5 Personal Emergency ............................. 37 Phone Access........................................ 8 Power ..................................................... 52 POWER/READY INDICATOR ............ 12 proper intrusion coverage ........................ 2 Quick Arm ............................................. 12 Quick Arming ..................................... 14 Quick Bypass...................................... 28 Quick Guide .................................. 58, 59 Ready ................................................... 25 READY .................................................. 35 Ready Key ............................................. 25
Relay Menu Mode ..............................41 Replacing Batteries ..........................56 RF BUTTON .........................................17 Routine Care.......................................57 Schedules ...........................................7, 42 Security Code ........................................14 Security Codes.......................................14 Sensing Devices.......................................5 Silencing a Fire Alarm .....................50 Silent Emergency ..................................37 Smoke Detectors ...................................49 Speed Key ..........................................7, 38 Stay ....................................................6, 20 STAY......................................................34 STAY Mode............................................29 System LO Bat ......................................51 Temporary Schedules .....................42, 43 Temporary Users ..................................17 Test Key.................................................49 Test Mode ..............................................49 Testing Your System.........................49 Time Window ........................................42 Trouble Condition .................................51 Unable To Arm Lobby...........................24 User Edit Mode .....................................16 User Numbers .......................................14 User's Instructions..................................8 Wireless Sensor .....................................56 Zone Bypassed.......................................29 Zone Descriptors ...................................26 Zones ........................................................5
– 66 –
– 67 –
TWO YEAR LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive, Melville, New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at its discretion, reflect the warranty period as commencing at invoice date. Except as required by law, this Limited Warranty is only made to Buyer and may not be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at its sole option and as the exclusive remedy hereunder, free of charge, any defective products. Seller shall have no obligation under this Limited Warranty or otherwise if the product: (i) (ii) (iii) (iv) is improperly installed, applied or maintained; installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than the Seller/Seller’s Authorized Service/Repair Center; damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or the like; or defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes unrelated to defective materials or workmanship, or failures related to batteries of any type used in connection with the products sold hereunder.
Exceptions to Warranty With Respect to Honeywell Products listed below: Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above limited warranty for a period of five (5) years from the manufacture date code. EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY (i) CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY WAY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY SELLER’S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Seller’s agents), specifications, samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in connection with the Buyer’s order are for the sole purpose of identifying the Seller’s products and shall not be construed as an express warranty or condition. Any suggestions by Seller or Seller’s agents regarding use, applications, or suitability of the products shall not be construed as an express warranty or condition unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a properly installed and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a guarantee that such will not occur or will not cause or lead to personal injury or property loss. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON ANY CLAIM AT ALL INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether directly or indirectly for any loss or damage with respect to the products it sells, regardless of cause or origin, its maximum liability shall not in any case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and shall be the complete and exclusive remedy against the Seller. Should your product become defective during the warranty, please contact your installer to facilitate repair or replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace any defective product under warranty with new, refurbished, or remanufactured product.
– 68 –
NOTES
– 69 –
NOTES
– 70 –
NOTES
– 71 –
2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747
Copyright © 2010 Honeywell International Inc. www.honeywell.com/security
ÊN5943-6V2@Š
N5943-6V2 5/04 Rev. B
- Uploaded