Passive Infrared
40ftx40ft (12mx12m) 85 ̊
5ft - 8ft (1.5m - 2.4m)
Mounting height
Detection method
Coverage
78 zones
3°F (1.6°C) at 2ft / sec (0.6m/sec)
1 - 5ft/sec. (0.3 - 1.5m/sec.)
Switch-able ON/OFF
Detection zones
Sensitivity
Detectable speed
LED indicator
Approx. 20 sec | 2 or 4
1 x CR123A Lithium battery
– 4°F - +122°F (–20°C - +50°C)
85% max.
Form C (micro switch)
Tamper switch
Pulse Count
Battery
Environment humidity
Operating temperature
WNX-40HW / WNX-40DS / WNX-402G / WNX-40IX
I. INSTALLATION HINTS
X. SPECIFICATIONS
II. DETECTION AREA
PIR Detector
PASSIVE INFRARED DETECTOR
WNX-40HW/WNX-40DS
WNX-402G/WNX-40IX
Avoid curtain, screen, etc. from blocking
detection area.
Eviter les obstacles masquant la zone de
détection (rideau, vitres)
Do not obscure even partially the
detector’s field of view.
Ne pas obscurcir partiellement ou
complètement le champ de vision du
détecteur.
Do not install
outdoors.
Ne pas installer
à l’extérieur.
Do not mount in an
unstable location where
vibrations or shock may
affect the detector.
Ne pas installer sur des
supports instables afin
d’éviter les vibrations et
les chocs pouvant
affecter le détecteur.
T
OP
VIEW
FE
ATURES
SIDE
VIEW
inches (mm)
inches (mm)
The nix sign indicates prohibition.
Dimensions
Mounting Position
Small animal tolerance applies to animals
0 to 40cm/0 to 16 inches in height
Tamper switch
Selectable pulse count 2 or 4
2/28/2018
59-2712-0
NOTE
Le signe non indique une interdiction.
INSTALLATION INSTRUCTIONS
Avoid direct sunlight.
Eviter le rayonnement solaire direct.
Avoid facing directly to air
conditioners or heating vents.
Eivter la proximité d’air
conditionné, de chauffage, etc.
Avoid vapor or
high humidity that
can cause
condensation.
Eviter la vapeur et
l’humidité pouvant
condenser.
OPTEX I
NC. (
U.S.)
URL: h
ttp://www
.opte
xamerica.com
OPTEX D O B
RASIL L
TDA. ( Brazil)
URL: h
ttp://www
.opte
x.net/br/es/sec
OPTEX (
EUROPE) L
TD. / E
MEA H
Q (
U.K.)
URL: ht
tp://www
.opt ex-europe.
com
OPTEX T
ECHNOLO
GIE
S B
.V. ( The N
etherland
s)
URL: h
ttp://www
.opte
x.eu
OPTEX S ECU
RITY S
AS ( Franc
e)
URL: h
ttp://www
.opte
x-security.com
OPTEX S ECU
RITY S
p.z o
.o. ( Poland
)
URL: h
ttp://www
.opte
x.com.pl
OPTEX PI
NNACLE I
NDIA, P
VT., L TD. ( Indi
a)
URL: h
ttp://www
.opte
x.net
/in/en/sec
OPTEX K
ORE
A C
O.,LTD. ( Korea)
URL: h
ttp://www
.opte
xkorea.com
OPTEX (
DONGG
UAN) C
O.,LTD.
SHANGHAI O
FF
ICE (
Chin
a)
URL: h
ttp://www
.opte
xchina
.com
OPTEX (
Thai
land
) C
O., L TD. ( Thai
land
)
URL: h
ttp://www
.opte
x.net/th/th
Copy right (C
) 2
016 O
PTEX C
O., LTD.
This uni
t is d
esigne
d t
o d
etect a
n i ntruder a
nd a
ctivate a
n a
larm c
ontrol pan
el.
Being o
nly a p
art o
f a c
omple
te s
ystem, w
e c
annot a
ccept r esponsibil ity f or
any dam
ages o
r o
ther c
onsequenc
es result
ing f
rom a
n i ntrusi
on.
- 1 -
- 4 -
WNX-40HW
Honeywell 5800 Series Compatible
WNX-402G
2GIG Compatible
WNX-40DS
DSC 433MHz Compatible
WNX-40IX
Interlogix 319.5MHz & QOLSYS Compatible
*Product is not produced by, endorsed by, nor is officially associated with
Honeywell, DSC, 2GIG, Interlogix, or QOLSYS.
Install in accordance with the Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681.
FCC NOTICE
This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be
received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the Resolution Products, Inc. could void the user’s authority to operate this equipment.
IC NOTICE
This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions:
(1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device.
Le présent appareil est conforme aux cnr d’Industrie Canada applicables aux appareils radio exempts de licence. L’exploitation est autorisée aux deux conditions suivantes:
(1) L’appareil ne doit pas produire de brouillage, et (2) L’utilisateur de l’appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d’en compromettre le fonctionnement.
“Honeywell”, “2GIG”, “Interlogix”, “DSC” are trademarks owned by Honeywell International, Inc, Nortek Security & Control LLC, United Technologies Corporation, and Tyco Safety Products Canada LTD, respectively.OP-
TEX Inc. products will function with one of either Honeywell, 2GIG, Interlogix, or DSC systems. However, no OPTEX Inc. product is produced by, endorsed by, nor is officially associated with Honeywell, 2GIG, Interlogix,
DSC.OPTEX Inc. recommends verifying proper enrollment and operation, per control panel installation instructions, at installation.
FCC ID
WNX-40HW/WNX-402G: U5X-RE261
WNX-40DS: U5X-RE361
WNX-40IX: U5X-RE161
IC ID
WNX-40HW/WNX-402G: 8310A-RE261
WNX-40DS: 8310A-RE361
WNX-40IX: 8310A-RE161
5
10
15
20
25
30
35
40 ft
0
2.4m
12
8
0
1
m
0 2 4 6
8 ft
5
10
15
25
30
35
40 ft
6 m
4
2
15
10
5
20 ft
2
4
6
8
10
12m
4
6 m
0
2
0
5
10
15
20 ft
20
Wall Tamper VI.
FUNCTIONS
III.
DESCRIPTION
AND
OPERATION
IV.
MOUNTING
VII. TROUBLE SHOOTING AND MAINTENANCE
*C onduct a w
alk t
est at least once per y
ear
.
E
S
U
A
C
E
L
B
A
B
O
R
P
M
E
L
B
O
R
P
REMED
Y
Loosen f
ast
ening screw
and r
emo
ve co
ver .
Mount the unit, install a
battery, and enroll the
transmitter.
Replace the co
ver
Select switch for Walk Test
from “ON” to “OFF”.
Fast
en co
ver with f
ast
ening
screw
.
Conduct a W
alk
Test.
- 3 -
- 2 -
V. ENROLLING TO CONTROL PANEL
1. LED ON / OFF
The Alarm LED indicator can be switched either “ON” or “OFF”.
2. PULSE COUNT
The Detection Mode can be switched to either “2” or “4” depending on the environmental conditions of
installation.
2: For normal applications.
4: For use in hostile areas where there may be movement of small animals or other objects such as fax
When the “4” is selected, the sensitivity may seem sluggish. Conduct a Walk Test to ensure that the desired
coverage is given.
3. WALK TEST SWITCH
WALK TEST
1) LED lights up when the unit has detected.
2) An alarm signal is output whenever it detects.
NORMAL : Normal Operation (Battery Saving Mode)
1) LED lights up when unit detects and “LED ON” is selected.
2) Once alarm is generated, another alarm will not generate for 2 minutes.
Interlogix:
Programming/Enrolling
• Place control panel into enrollment mode
• Remove battery tab to automatically send entire RF enrollment
sequence, or
• Open cover to send Tamper Signal
QOLSYS:
Programming/Enrolling
• Place control panel into enrollment mode.
• Remove battery tab to automatically send entire RF enrollment
sequence, or
•
Open cover to send Tamper Signal
Honeywell:
Programming/Enrolling
• Enroll by placing the panel into wireless enrollment mode
• Remove battery tab while holding Tamper to automatically
send entire RF enrollment sequence, or
• Trip (alarm or tamper) 3 times, or
• Enter the sensors ID number
Enrollment Tips
• Program as an RF type (Supervised RF)
• Program as Loop 1
• Loop 4 = Tamper
2GIG:
Programming/Enrolling
• Place control panel into enrollment mode
• Remove battery tab while holding tamper to automatically send entire
RF enrollment sequence, or
• Trip (alarm or tamper) 3 times, or
• Enter the sensors ID number
Enrollment Tips
• Confirm Loop 1 is selected
• Power down the PIR after enrollment to keep panel from mistakenly
double enrolling the sensor.
DSC:
Programming/Enrolling
• Place control panel into enrollment mode
• Remove battery tab to automatically send entire RF enrollment
sequence, or
• Open cover to send Tamper Signal, or
• Enter the sensors ID number
Cryptix:
Programming/Enrolling
• Place control panel into enrollment mode
• Remove battery tab to automatically send entire RF enrollment
sequence, or
• Open cover to send Tamper Signal, or
• Enter the sensors ID number
Alarm is not activated
although someone is
walking in detection
area.
Unintended activation
(False Alarm)
LED does not light up at
the time of walk test.
Detection area is improper.
Battery is dead.
Battery is dead.
Walk Test switch is OFF.
Conduct a walktest. See Section II.
Change battery.
Change battery.
Turn the Walk Test switch on. See Section VI.
Turn the Walk Test switch on.
Remove the object from the detection area.
Remove the heat sources from the detection area or relocate
the detector.
Walk Test switch is OFF.
Moving object within detection area.
(curtain, wall hanging, etc.)
Temperature of object within area is changing rapidly.
(heater, air conditioning, etc.)
VIII. BATTERY LIFE
IX. OPTIONAL ACCESSORIES
The values indicated are only for reference on each condition. The sensor will send low battery transmissions to the control panel.
CR123A (3V, 1300mAh)
machines or curtains.
(Factory setting)
ON
OFF
(Factory setting)
2
4
(Factory setting)
WALK TEST
NORMAL
Alarm trigger per day
Battery Life
240
Approx. 7 years
720
Approx. 3 years
Lens
Tamper Knockout
Mounting Knockout
Corner Mounting
Knockout
Corner Mounting
Knockout
Fastening Screw
LED Indicator for
-Warm-up period
-Alarm
TOP
VIEW
SIDE VIEW
1.5m
10
5ft
20
30
40
50
60 t
f
0
1.5m
5
10
15
18m
0
5ft
0
10
20
30
40
50
60 t
f
18m
15
10
5
0
2.4m
LONG RANGE
(OPTIONAL
LENS: FL-60N)
18 x 1.8m (60 x 6ft.)
FA-3
Compact Wall & Ceiling Mount Bracket
- Uploaded