Qolsys IQ Flood-S - Quick Install Guide Dated 12/17



Related Products

Qolsys IQ Flood-S - Wireless Flood Sensor
Qolsys IQ Flood-S
Wireless Flood Sensor
List Price: $86.00
Our Price: $60.99

Related Categories


Document Transcript

Sensor: 2.5”H x 1”W x .5”D
Wireless signal range: 600ft (200M), open air.
Code outputs: tamper, tamper restore, alarm, alarm
restore, low battery.
Transmitter frequency: 319.5 MHz
Unique code ID
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m
Operating Temperature: -10C~50C
Relative Humidity: 5-95% Non-Condensing
Storage Temperature: -40-80C
Replace battery with exact replacement every 5 years
with 3V Lithium (x2).
(2) -Panasonic CR2032
-Energizer CR2032
-Duracell DL2032
STEP
1
CHOOSE
INSTALLATION
LOCATION
SPECIFICATIONS
Water heater
Basements
Laundry rooms
Sump pumps
Kitchen sinks
Bathroom sinks
Bathrooms
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
IQ FLOOD S-LINE QUICK INSTALL GUIDE Document#: IQFLOOD-SQG-12-17
Revision#: 12/8/17
Issue Date: DEC 2017
Qolsys Product #: QS5536-840
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2ABBZ-RF-CHW-S
IC: 11817A-RFCHWS
CONTACT TECH SUPPORT
TechSupport@Qolsys.com
GOT QUESTIONS?
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
STEP
2
STEP
3
REMOVE
BATTERY
TABS
STEP
4
MOUNT
SENSOR
STEP
5
LEARN
INTO
PANEL
Water detection unit rests or mounts to the floor or can be mounted to a wall
or baseboard. Trim or tie off extra cord as needed or desired.
APPLY
ADHESIVE
Mount the sensor above the floor level to prevent water damage.

Place your panel in
“autolearn" mode
ADD
Open and close the case to
“tamper” the device
Select “Water” as sensor type. Then select “IQ Flood” (Qolsys) or “Other
Flood” (Non-Qolsys) and customize settings as desired, then touch Add.
SECURE
CONNECTS
USING
319.5 MHz


Uploaded