Qolsys IQ Panel 4 - Firmware Update 4.2.1 - Release Notes Dated 10/17/22
Related Products
Document Transcript
TSB #:
221017
DATE:
10/17/22
RE:
IQ PANEL 4/IQ4 HUB - 4.2.1 SOFTWARE UPDATE
RELEASE NOTES & UPDATE INSTRUCTIONS
Release Notes:
Fixes/Improvements:
•
Corrected an issue where a small number of IQ Panel 4’s experienced a false panel overheating shutdown
event caused by an inaccurate panel battery temperature reading.
Update Instructions:
Compatibility Note: Your IQ Panel must be on software version 4.1.1 or higher and connected to Wi-Fi to install
this update wirelessly. Panels running 4.0.0, 4.0.1 or 4.1.0 must be updated to 4.1.1 first, then they can be updated
directly to 4.2.1.
1- Swipe down from the top of the screen and touch “Settings"
2- Touch “Advanced Settings”
3- Enter a valid installer code (default is 1111)
4- Touch "Upgrade Software"
5 -Touch “Patch Tag” and enter the patch
iqpanel4.2.1
then touch OK
6- Touch "Upgrade Using Network" (panel must be connected to Wi-Fi).
Update will download and install
7- Once complete touch "OK" to reboot the panel.
DO NOT TOUCH THE SCREEN.
The update process will take
approximately 5 minutes. After the panel reboots the home screen will appear and the LED will turn green.
TECHNICAL SERVICE BULLETIN
IQ PANEL 4/IQ4 HUB - 4.2.1 SOFTWARE UPDATE - RELEASE NOTES AND INSTRUCTIONS
- Uploaded