IMPORTANT NOTE:

The IQ Shock is intended to be installed on doors with or without glass inserts and
on window frames but not on the actual glass surface.
MAGNET

Exterior Doors

Sliding
glass
doors
Windows



IQ SHOCK MINI-S QUICK INSTALL GUIDE
CHOOSE
INSTALLATION
LOCATION
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
Two dip switches allow you to customize the behavior of this device:

STEP

2
DIP

SWITCH
CONFIGURATION
SPECIFICATIONS
STEP

1
DS#1 - Installer Test Mode:

-
Calibrates accelerometer orientation.

-
LED is Active for dialing in shock
sensitivity with potentiometer.

-
Please note, when test mode is enabled
(ON) the IQ Shock Mini will NOT transmit
signals to the IQ Panel.
 
This mode is only
used for initial installation and calibration
of the shock sensor.
ON:

OFF:

-
Disables installer
test mode.
DS#2 - Reed Switch:

ON:

OFF:

-
Enables reed switch (must be ON for UL
installations).
-
Disables reed switch.

SENSITIVITY
LEVEL
ON
1
2
MAX
MIN
LED
DIP

SWITCHES
Sensitivity Level:

CLOCKWISE:

COUNTER-
CLOCKWISE:
-
More Sensitive
-
Less Sensitive

Sensor: 2.5”H x 1”W x .5”D

Code outputs: tamper, tamper restore, alarm, alarm restore, low battery.

Transmitter frequency: 319.5 MHz

Supervisory keep-alive interval: 70 minutes.

RF Peak field strength: typical 36000 uV/m at 3m

UL/ULC listed for residential use only

Operating Temperature: -5C~45C

Relative Humidity: 5-95% Non-Condensing

Storage Temperature: -25-70C

Replace battery with exact replacement every 5 years with 3V CR2032
Lithium (x2). STEP

3
STEP

5
APPLY
ADHESIVE
STEP

4
REMOVE
BATTERY
TABS
1” MAX
MOUNT

SENSOR &
MAGNET
STEP

6
LEARN

INTO

PANEL
Place your
panel in
“Auto Learn”
mode
Open and
close the case
to “tamper”
the device
ADD
Customize name
and settings as
desired and and
touch “ADD”
STEP

7
ADJUST

SHOCK

SENSITIVITY
Adjusting the Shock Sensitivity:

IMPORTANT:
Calibrate the IQ Shock Mini’s accelerometer from the final mounting position by moving dip switch 1 to ON (enable installer test
mode).
 
While in this mode the LED will flash RED when it detects a shock level strong enough to trigger an alarm at the control panel. There are
3 total sensitivity settings and the LED will flash each time the sensitivity threshold is changed.
Please note that no RF transmission from the
sensor occurs during installer test mode.
Document#: IQSM-QG

Revision#: 05/25/23

Qolsys Product #: IQSM

FCC ID: 2AAJXQS-IQSKM

IC: 11205A-QSIQSKM
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment. This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the
following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada exempts de licence
standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences
et (2) cet appareil doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.
UL/ULC NOTE:

The IQ Shock Mini - S has been listed by UL/ULC for
residential applications only and in accordance with the
requirements in the Standards UL 634 and UKLC/ORD-C634
for Door and Window Contact with supplementary Shock
Sensor. The shock sensor is for supplementary detection
only and not for primary protection of the surface and is not
intended for use as a glass break detector.
Scan for full manual
https://bit.ly/45wgm9o
Gently hit (using the palm of your hand) the surface on which the device is installed. Gradually increase the pressure or turn
the shock sensitivity adjustment dial clockwise with a small screwdriver until the desired response is obtained. Ensure that
the device is not triggered by accidental vibration (e.g., wind, birds, window coverings) hitting the protected window or
surface. Normal traffic or operation of the door/window should not trip the shock sensor. When testing the sensitivity of the
unit, do not cause stress or damage to the mounting surface or to the glass.
WARNING:
In order to avoid personal injury
while testing sensitivity, do not apply pressure to glass inserts or windows.

Move dip switch 1 to OFF (disable installer test mode) once shock sensitivity has been set to the desired level. Verify that the
IQ Shock Mini properly communicates with the Panel.