TSB #:
240411
DATE:
04/11/24
RE:
IQ PRO - 4.3.0n SOFTWARE UPDATE - RELEASE NOTES & INSTRUCTIONS
Release Notes:
New Features:
•
Added support for PowerG Home Automation.
•
Added EN/UK Feature Set Support.
•
Added support for the PowerG + Devices.
•
PGP9945 - Door/Window Contact with External Input.
•
PGP9303 - Vanishing Door/Window Contact.
•
PGP9914 - Flat PIR Motion Detector.
•
PGP9922 - Glass Break Detector.
•
PGP9920 – Repeater.
•
Added support for Proximity Tags –easily arm/disarm with a tag on supported keypads.
•
Added support for Force Arm – allowing auto-bypassed zones to be reactivated if closed while armed.
•
Added support for Manual selection of Z-Wave Frequency Region.
•
Added new Key Switch Arm and Disarm Only option.
•
Added support for the new PGHPHOST9 PowerG Host+
•
Added New PGM Rule options.
•
Zone Follower now supports all sensor types.
•
Bypass rules.
•
Troubles rule.
•
Burglary Confirmed rule.
•
Added support for Global EOL Input selection.
•
An Active IQ Installer connection will now Inhibit Arming during Local Programming.
•
EU External Bell – Bell Output can be configured for EU external bell compatibility.
•
Added support for the soon to be released IQ Keypad – New PowerG keypad.
•
Added support for Anti-Masking Trouble – for PowerG devices that support anti-masking.
•
Added a new Cross Zoning feature – which requires two or more zones to activate before generating an alarm
condition.
•
Added Non-bypassable Zone attributes – Individual zones can now be programmed to not allow bypassing.
•
Temperature Display on LCD Keypads – LCD and TCH keypads can now display indoor and outdoor
temperature based on PowerG device temp reporting.
•
Added support for Alarm.com Flex I/O sensors.
Fixes/Improvements:
•
Arming from Alarm.com will now fail if a zone is open or in trouble and auto bypass is disabled or force bypass
is not selected.
continued on Page 2...
TECHNICAL SERVICE BULLETIN
IQ PRO - 4.3.0n SOFTWARE UPDATE - RELEASE NOTES AND INSTRUCTIONS ...continued from Page 1.
•
Corrected an issue with the HS2TCH keypads where in certain cases the Fire, Ambulance and Police, Options
and Outputs buttons are greyed out on power up (
new GUI v1.35.02.004 flash files available
)
Update Instructions:
Compatibility Note:
Your IQ Pro must be on software version 4.2.1n or higher and connected to Wi-Fi or Ethernet
to install this update.
1- Connect to IQ Pro utilizing the IQ Installer Interface
2- Touch “Configuration”
3- Touch "Upgrade Software"
4- Touch “Patch Tag” and enter the patch
iqpro4.3.0n
5- Touch "Yes, I want to upgrade" (panel must be connected to Wi-Fi or Ethernet). Update will download and
install
6- The update process will take approximately 5 minutes. After the panel reboots reconnect the IQ Installer
Interface
TECHNICAL SERVICE BULLETIN
IQ PRO - 4.3.0n SOFTWARE UPDATE - RELEASE NOTES AND INSTRUCTIONS
- Uploaded