VISTAH
L
KP

Wired 2x16 LCD Keypad


Installation and Setup Guide

GENERAL INFORMATION

This Keypad is intended for use with the First Alert Pro
VISTA
Hybrid Control Panel and it's iBus.
The keys on the keypads are backlit for
convenience. Up to a total of eight (8) keypads can be used on the system.

See below and refer to the Control Panel's instructions for details.

KEY FUNCTIONS

1

2X16 Alpha LCD Display

2

Power LED

3

Status LED

4

Disarm Key

5

Arm Maximum (No Entry
Delay)

6

Arm instant (No Entry Delay)

7

Medical

Panic

8

Panic

9

Fire

Panic

10

Police

Panic

11

Scroll Status

12

No other function

13

System Tests

14

#

Key

15

Quick Arm Night Option

16

Chime Mode

17

Quick Arm Home Option

18

Bypassing Sensors

19

Quick Arm
Away O
ption

20

Arm Stay

21

Arm Away

22

Trouble LED



OPERATING THE KEYPAD

For operating instructions, refer the Control Panel User Guide.


LEDs

Off

Red

Green

Flashing Red

Yellow


POWER (Control Panel)



AC

Low
Battery (no AC)



STATUS*

(Partition)

Not Ready to Arm

Armed

Ready to Arm

Alarm / Alarm Memory



TROUBLE





Device / System
Trouble

* Programming Mode: Status LED flashes between Red and Green.


KEYPAD MOUNTING

The keypads are surface mounted directly to a wall or to a single gang outlet box
[A] with or without the provided optional mudplate [B]
.
IMPORTANT:

Damage to product can occur if incorrectly wired. See summary of connections below for proper wiring.

1.

With the case back removed, route the 4 wires from the control through the opening in the wall mount.

2.

Mount the wall mount using the provided screws.
Insert the tamper screw as shown.

3.

Connect the 4 wires to the keypad terminal block. Observe polarity.
See the Wiring Table below for distance limitations.

a)

iBus A

b)

iBus B

c)

Negative (
-
)

d)

Positive (+)

4.

Align the case with the cleats and snap into place.

5.

Secure with bottom screw.

NOTE
:
Type of Signaling Device: Type AM




VIS
TAHLKP-002-V0
1
2
3
4
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
5
6
7
OFF
SELE
CT
SCROLL
MAX
TES
T
BYPASS
INS
T
AN
T
READY
CODE
CHIME
VIS
TAHLKP-001-V0
a
b
c
d
A
B
ENROLL THE KEYPAD

The keypad must be enrolled.
Follow the instructions in the controls Installation and Reference Guide for enrolling an iBus device.

PANIC KEYS

This keypad also features panic keys. These keys may be programmed for
Fire, Police and Medical alarms. Panic activation requires a 2
-button
sequence. After the first button in the sequence is pressed, you can cancel
the panic by pressing any key other than one of the panic keys.



Panic

There are 3 ways to generate an alarm:

1.

Press Panic and within 10 seconds press the desired panic
key (Fire, Police, Medical)

2.

Press desired panic key and within 10 seconds press the
Panic button.

3.

Press desired panic key and within 10 seconds press the
same key.


Fire


Police


Medical


Keypad Menu Mode

This
mode displays keypad
-programmed information and provides access to Default, Reset, LCD Brightness, and Backlight options. Press and hold the 3 key

for 2 seconds to enter Menu Mode.
The system will exit Menu Mode after 1 minute of inactivity.
Press the 3 key to scroll or the * key to exit.

Display

Meaning/Option

App:

Boot:

Displays the keypad’s current App and Boot versions

iBus=

Keypad MAC=

Displays iBus version
information and the Keypad MAC Address.

LCD Brightness

Prompts to change LCD brightness. 2 will toggle from Low, Medium and High

LCD Backlight

Press 2 to cycle through options for: Always Off / ON, After 1, 5, or 15 minutes.

A: None

(Future Use)

SPECIFICATIONS:

Physical
.....................................................................................................................................................................................................................................
6.81"
W x 4.83"
H x 0.84"D

Voltage
..........................................................................................................................................................................................................................................
12 VDC
(power-
limited)

Current
..........................................................................................................................................................................................................................................................................
70mA

NOTE:
ARMED LED lit, LCD backlight and sounder on, reduces to 20mA when panel is operating in standby mode (backlight off)

Sounder
..........................................................................................................................................................................................................................................................
Piezo
-electric

NOTE:
Fire alarm is loud, pulsing single tone; (all keypads) burglary alarm is loud, continuous, dual tone

NFPA
-
72

................................
................................
................................
................................
................................
................................
................................
.............................

Compliant


when listed

FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or U
ser's Manual. Unauthorized changes or modifications could void the
user's authority to operate the equipment.

CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part
15.105. The Class B Digital Device statement can be viewed at:

https://customer.resideo.com/en
-US/support/residential/codes
-and
-standards/FCC15105/Pages/default.aspx

FCC / IC STATEMENT

This device complies with Part 15 of the FCC Rules, and Industry Canada’s license
-exempt RSSs. Operation is subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) This device must accept any interference receiv
ed, including interference that may cause undesired operation.

Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, Ph: 516
-577
-2000

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL PANEL WITH WHICH THIS DEVICE IS USED, FOR DETAILS ON LIMITATIONS OF TH
E ENTIRE ALARM SYSTEM.

For the latest warranty information, please go to:

https://www.security.honeywellhome.com/hsc/resources/wa/index.html

For technical support, call
1-800
-645
-7492, M
-F 8:30am to 5pm EST.

For documentation, go to:
www.resideo.com

This equipment should be installed in accordance with National Electrical Code, NFPA 70, Standard for the Installation of Res
idential Fire Warning Systems, CAN/ULC
-
S540 and Chapter 2 of the National Fire Alarm Code, ANSI/NFPA 72
(National Fire Protection A
ssociation, Batterymarch Park, Quincy, MA 02269). Printed information describing proper installation, operation, testing, mai
ntenance, evacuation planning, and repair service is to be provided with this
equipment.

Canadian Installations

For Installation in Canada, wiring shall be in accordance with CSA C22.1, Canadian Electrical Code, Part I, Safety Standard f
or Electrical
Installations; CAN/ULC S302, Standard for the Installation, Inspection and Testing
of Intrusion Alarm Systems; and CAN/ULC S301, Standard for Signal Receiving Centre Intrusion Alarm Systems and Operations.

Warning
: Owner’s instruction notice: ’Not to be removed by anyone except occupant’

This system must be checked by a qualified technician at least once every three (3) years.

Note:
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The correct disposal of end
-of -life equipment will help prevent potential negative
consequences for the environm
ent and human health.

Any attempt to reverse
-engineer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is strictly prohibited.

Resideo Technologies, Inc

2 Corporate Center Drive

P.O. Box 9040, Melville, NY 11747

© 2024 Resideo Technologies, Inc. All rights reserved


ÊR800
-
28765AaŠ

R800
-28
765
A 8
/24 Rev A


iBus Wiring Limitations

NOTE:
The length of all wire runs for all partitions combined must not exceed 3000 feet
(914m) when unshielded quad conductor cable is used or 1500 feet (457m) if shielded
cable is used.

Wire Gauge
(AWG)

Total Current of All Devices Connected to a Single
Wire Run

50mA or
less

100mA

300mA

500mA

600mA

#22

700ft

350ft

120ft

70ft

60ft

#20

1200ft

600ft

200ft

120ft

100ft

#18

1900ft

950ft

320ft

190ft

160ft

#16

3000ft

1500ft

500ft

300ft

260ft