Yale Real Living YRD210 Installation Manual and Setup Guide



Related Products

Yale YRD210 - Z-Wave Push Button Deadbolt Lock
Yale YRD210
Z-Wave Push Button Deadbolt Lock

Related Categories


Document Transcript

Yale Real Living™ Push Button Deadbolt
Installation and Programming Instructions
NOTE TO INSTALLER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN DAMAGE TO THE PRODUCT AND VOID THE FACTORY WARRANTY

For Technical Assistance call Yale at 1-800-810-WIRE (9473)
This document is available on our website in printed Spanish and French. Go to www.yalerealliving.com. Click “Product Information & Documentation” and then “Installation Instructions”. Este documento está disponible en español en nuestra página de internet. Vaya a www.yalerealliving.com. Presione “Información del Producto y Documentación” y luego “Instrucciones de Instalación”. Ce document est disponible sur notre site Web dans le français imprimé. Allez à www.yalerealliving.com. Cliquez sur le “ ; Information sur le produit et Documentation” et puis “Installation Instructions”.

P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

TABLE OF CONTENTS Warnings ..................................................................................................................... 2-4 Reset Lock to Factory Default ..................................................................................3 Introduction .....................................................................................................................4 Installation Components and Tools.............................................................................................5 Prepare Lock for Installation .....................................................................................6 Install Lock............................................................................................................ 7-8 Programming Programming Features-Menus-Keys-Definitions ............................................... 9-10 Lock Operation ................................................................................................. 11-12 Miscellaneous Information Hardware Troubleshooting......................................................................................13 Programming Troubleshooting ...............................................................................14 Installing the Network Module ................................................................................15 Replace/Install Cylinder ..........................................................................................16 Sample Pin Code Management Sheets ........................................................... 17-18 WARNINGS
Warning: Changes or modifications to this device not expressly approved by Yale Security, Inc. could void the user's authority to operate the equipment. IMPORTANT: The accuracy of the door preparation is critical for the proper functioning and security of this product. Misalignment can cause performance degradation and a lessening of security. Finish Care: This lockset is designed to provide the highest standard of product quality and performance. Care should be taken to ensure a long-lasting finish. When cleaning is required use a soft, damp cloth. Using lacquer thinner, caustic soaps, abrasive cleaners or polishes could damage the coating and result in tarnishing.

FCC:

FCC ID: U4A-YRHCPZW0 (Z-Wave); U4A-YRHCPZB0 (Zigbee) Model(s): YRDZW, YRDZB This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful Interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help.
An ASSA ABLOY Group brand

2

P/N AYRD210-INST-FUL Rev B

To Ensure Proper Lock Handing and for an explanation of how to determine your lock handing, please read this important note.
IMPORTANT: Do not install batteries until the lock is completely installed on door. For your convenience, the Yale Real Living lock will automatically determine whether it will function as a right or left-handed lock. (The "hand" or "handing" of the lock, is determined by the side of the entry door that the hinges are on when standing outside the door) When the batteries are properly inserted for the first time, the lock will attempt to determine its handing - whether the lock is installed on the door or not. If the lock is not completely installed on the door, it could hand itself incorrectly. Should this occur, the lock must be installed on the door and then reset to its factory defaults, allowing the lock to "hand" itself correctly. To reset the lock to factory default, see the following:

Reset Lock to Factory Default
The following procedure clears the automatic handing of the lock and returns the lock to programming default - deleting all user codes and setting the Master PIN code* back to the default ("12345678"). 1. Remove the batteries and then remove the inside escutcheon to access the reset button. 2. The reset button (see image at right) is located above the PCB cable connector. 3. Hold down the reset button for a minimum of 3 seconds and then reinstall the batteries; once the batteries are properly installed, release the reset button. 4. Reassemble the lock by reversing the same steps on page 6. All features should now be returned to factory default.
*The default Master PIN code must be changed prior to programming of the lock. Reset Button

Cable

Inside Escutcheon

3
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Industry Canada: Canadian ID: 6982A-YRHCPZW0 (Z-Wave); 6982A-YRHCPZB0 (Zigbee) Model(s): YRDZW, YRDZB This Class B digital apparatus meets all requirements of the Canadian Interference Causing
Equipment Regulations. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée. For the U4A-YRHCPZB0 and 6982A-YRHCPZB0, the following statement applies: “This equipment complies with FCC/IC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.” Section 7.1.2 of RSS-GEN Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication. En vertu des règlements d'Industrie Canada, cet émetteur radio ne peut fonctionner avec une antenne d'un type et un maximum (ou moins) approuvés pour gagner de l'émetteur par Industrie Canada. Pour réduire le risque d'interférence aux autres utilisateurs, le type d'antenne et son gain doivent être choisies de façon que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui est nécessaire pour une communication réussie. Section 7.1.3 of RSS-GEN This Device complies with Industry Canada License-exempt RSS standard(s). Operation is subject to the following two conditions: 1) this device may not cause interference, and 2) this device must accept any interference, including interference that may cause undesired operation of the device. Cet appareil est conforme avec Industrie Canada RSS standard exemptes de licence(s). Son fonctionnement est soumis aux deux conditions suivantes: 1) ce dispositif ne peut causer des interférences, et 2) cet appareil doit accepter toute interférence, y compris les interférences qui peuvent causer un mauvais fonctionnement du dispositif.

INTRODUCTION
The Yale Real Living™ Stand-alone Push Button Deadbolt Lock combines a robust lockset with a contemporary electronic aesthetic. Users benefit from a push button keypad that makes day-to-day access effortless for simple updates to user information in the event of staffing changes or security breaches. Yale Real Living™ is engineered for quick and easy installation and fits in place of a standard deadbolt lock door prep (ANSI/ BHMA A156.115). If this is an RF-enabled network lock, it needs to be located within 50 - 100 feet of another network controller. That distance is influenced by objects between the lock and the controller and may be expanded depending on proximity to other RF network devices. Also, if the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.

4

P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

INSTALLATION
COMPONENTS AND TOOLS Included in the box. . .
Quick Start Guide Installation Instructions Door Marker Outside Escutcheon Inside Escutcheon Inside Mounting Plate Battery Cover 4 AA Alkaline Batteries Bolt Strike Plate Screw Pack Keys

Parts Illustrations

Bolt Battery Cover

Outside Escutcheon

Inside Escutcheon

Inside Mounting Plate

4 AA Alkaline Batteries

Strike Plate

(2) Through bolts

(3) Inside Escutcheon Mounting screws Keys Network Module (Optional)

(4) Bolt & Strike Plate Mounting Screws

Tools Needed Door Prep
ƒ ƒ ƒ ƒ 2-1/8" (54mm) hole saw 1" (26mm) boring bit 7/64" (2.5mm) drill bit Chisel & hammer

Lock Installation
ƒ #2 Phillips screwdriver

5
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

PREPARE LOCK FOR INSTALLATION Unpack the Lock
The lock is packed representative of how it will install on the door. Before installing the lock on the door: A. Inside escutcheon 1. Loosen the screw (Phillips #2) holding the battery cover. (The screw remains attached to battery cover) 2. Slide the battery cover up and out (note the two tabs at bottom of battery cover). 3. Remove the inside mounting plate (with gasket) from the back (door side) of the inside escutcheon.

Battery Cover 2

Inside Escutcheon 1

a. Ensure that gasket on Inside Mounting Plate is properly fitted. Note the positioning of the gasket's five rubber nubs (Figure 3A) .
Inside Escutcheon & Mounting Plate (with gasket) 3
Figure 3A

B. Bolt Note: Bolt ships with backset in 2-3/8" position. If required, press small black button on underside of bolt and pull to extend to 2-3/4" backset position.

Detail 3B1 Figure 3B

C. The outside escutcheon (with gasket) remains assembled.

Outside Escutcheon

6
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

INSTALL LOCK
1. Install bolt in door. NOTE: The bolt must be in a retracted (unlocked) position when installing the lockset. Attach with (2) M4 x 25.4mm [8-32 x 1"] screws supplied. 2. Install strike on the door frame, making sure to allow for the bolt to be centered in the strike.
(2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws

1

2

(2) M4 x 25.4mm [8-32 x 1"] Flat Head Combination Screws

3. Install outside escutcheon. As you position the outside escutcheon, route the cable through 2-1/8" diameter hole (Figure 3A). NOTE: Cable goes under bolt (see Fig. 3B).

4. Holding the outside escutcheon flush to the door, position the inside mounting plate by first routing the cable and connector through the mounting plate's 1/2" hole (Fig. 4A) and then inserting the mounting plate “tongue“ into the bottom slot of the outside escutcheon (Fig. 4B).

Figure 3A

Figure 3B

“Tongue”
Figure 4A Figure 4B

7
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

5. Secure both assemblies using (2) M6 x 59.5mm pan head machine screws, making sure that outside escutcheon is vertically aligned. Hand-tighten until snug. Do not over-tighten. CAUTION: Use care when assembling to ensure that the cable lies against the back recessed area of the inside escutcheon (Fig. 6A). Position and bend cable, using the harness clip as shown in Fig. 6A to prevent binding when installing the escutcheon over the mounting plate. 6. Attach cable assembly to the inside escutcheon PC board by lining up notches on top of cable connector to slots on PCB connector (Fig. 6B). Note that connector should be pressed in firmly using thumbs until completely seated (proper position indicated by arrows on PCB as in Fig. 6A & 6B ) .
Harness clip

Route cable as indicated do not cover hole

Figure 6A

Figure 6B

7. Install inside escutcheon on inside mounting plate. Note the horizontal orientation of the tailpiece (Fig. 7A) as you insert the inside escutcheon (thumb turn should be vertical).
Figure 7A

8. Install and secure using (3) M4 x 8mm [8-32 x 5/16"] pan head screws through the inside escutcheon into the mounting plate. IMPORTANT: Before installing the batteries, test the mechanical operation of the lock by using both thumb turn and the key. The movement of the bolt should be smooth and unobstructed. If operation is not smooth, review the previous steps to ensure proper installation. 9. Insert four (4) AA alkaline batteries. The lock responds with a series of beeps, a red/blue flash and a quick flash of all keypad LEDs. When activating the lock for the first time, the lock will adjust for proper handing. Note: Refer to programming instructions prior to completion of step 10. 10. Install battery cover and tighten Phillips head screw.

8
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

PROGRAMMING FEATURES - MENUS - KEYS - DEFINITIONS Outside
Status Indicator

Inside
Phillips Screw Battery Cover Network Module Slot Numbers Cylinder Thumb Turn Privacy Mode Button

Alkaline Batteries 4 AA Type Status Indicator

Menu and Icons Used in This Guide
Click the indicated number.

~
Press the Star key on the keypad to Enter or Accept entry. Press the Pound key on the keypad to enter Menu mode.

M U

Enter Master PIN code (4-8 digits in length). (Factory default: 12345678) Enter User PIN. Can be 4-8 digits in length. User Number (1 - 25); RF Controlled (1 - 250).

Status Indicators
1
Low Battery Warning RED

2

Lock-out Mode RED & BLUE

3

Return to previous step BLUE

9
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Definitions
Lockout Mode: This feature is enabled by the Master code. When enabled, it restricts all user PIN code access. When attempting to enter a code while the unit is in Lockout, the Status Indicator flashes RED and BLUE; the keypad flashes as well. Low Battery: When battery power is low, the Status Indicator flashes RED. If battery power is completely lost, use the key override. Master PIN Code: The Master code is used for programming and for feature settings. NOTE: The default Master Pin Code must be changed prior to programming the lock. The Master code will also operate the lock. Privacy Mode: This button located under the thumb turn on the inside escutcheon, activates and deactivates the keypad and is indicated by a BLUE flash every ten (10) seconds. It is also overridden by mechanically operating the thumb turn or key. Auto Re-lock Time: After successful code entry and the unit unlocks, it will automatically re-lock after a default of thirty (30) seconds. Re-lock time is adjustable from five (5) to thirty (30) seconds. One Touch Re-Lock: When the bolt is retracted, activating the keypad will extend the bolt (during Auto Re-Lock duration or when Auto Re-Lock is disabled). Shutdown Time: The unit will shutdown for a default of sixty (60) seconds and not allow operation after the wrong code entry limit has been met. When the unit is in Shutdown, the Status Indicator flashes RED and BLUE; the keypad flashes as well. Audio Mode: Choosing Disable (3) in Audio mode shuts off the code confirmation tone playback for use in quiet areas. Audio mode is enabled or disabled through feature programming by the Master code. Status LED: Located on inside escutcheon. User PIN Code: The User code operates the lock. Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes. Wrong Code Entry Limit: After a specified number of unsuccessful attempts at entering a valid PIN code the unit will shut down and not allow operation. Wrong code entry limit is adjustable from three (3) to ten (10) times through feature settings (up to 5 times with no RF network enabled - default is 5; 10 with RF network enabled).

Factory Defaults
Settings Master Code Auto Re-lock Audio Re-lock Time Wrong Code Entry Limit Shutdown Time *Adjustable with Network Module Factory Defaults 12345678 Enabled Enabled *30 Seconds *5 Times *60 Seconds

10
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Lock Operation
Change Default Master Code Before Programming*
1. Enter the 8-digit default Master PIN code (12345678) followed by the 2. Enter “1” followed by the key. key. 3. Enter new 4-8 digit Master PIN code followed by the
*Default Master PIN Code must be changed prior to programming the lock.

key.

1 1
Enter current Master PIN code, followed by the key.

2
Enter '1' to change Master PIN code, followed by the key.

3
Enter the new Master PIN code (4~8 digits), followed by the key.

PIN code structure
Maximum number of user codes is 250 with Network Module; without Network Module, maximum is 25 user codes.

Set Up User Codes
User Codes can only be programmed through the Master Code. 1. Enter the 4-8 digit Master PIN code followed by the key. 2. Enter “2“ followed by the key. 3. Enter the User number to be registered (1-25) followed by the 4. Enter a 4-8 digit PIN code for the User number followed by the

key. key.

Note: When registering User codes, the code must be entered with in 20 seconds. If time expires, no codes are registered and the process must be re-started.

Privacy Mode vs. Lockout Mode
ƒ Lockout is a Menu feature that restricts Pin code access (except Master). ƒ Privacy mode is set by pressing and holding the button (found below thumb turn) for a duration of four beeps. This deactivates the keypad, and because it is set from the inside, provides a secure lock for the convenience of the occupant(s).

11
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Open Door with PIN Code 1
Enter PIN code.

2
Complete the code entry by pressing the key.

3
Unlock.

Feature Programming Through Menu Mode Using Master Code
1. Enter the 4-8 digit Master PIN code followed by the key. key. 2. Enter digit corresponding to the function to be performed followed by the

Note: If the lock is connected to a network controller, it is recommended that it is programmed through the centralized user interface (PC or hand-held device) to ensure communication between the lock and the controller unit.

1

2
Master PIN Setting

User Number (UN) ƒ 1~25: without network module

M

M
U

ƒ 1~250: with network module
Complete

User PIN Registration

User PIN Deletion

Complete

Auto Re-lock

Enable

Disable

Audio Mode

Enable

For quiet areas, select Disable (3) in Audio Mode.

Disable

All Code Lock-out

Enable

Disable

7 *Network Module Setting
*This function appears only with network module installed

Register Delete

CAUTION: When joining a network your controller may or may not be aware of any previously saved user codes stored in the lock. It is recommended that all user codes be deleted from the lock prior to joining a network.

12
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

MISCELLANEOUS
Hardware Troubleshooting......................................................................................13 Programming Troubleshooting ...............................................................................14 Installing the Network Module ................................................................................15 How to Replace/Install Cylinder .............................................................................16 Sample Pin Code Management Sheets ........................................................... 17-18

TROUBLESHOOTING Hardware Troubleshooting
Cycle the lock in both the locked and the unlocked positions. If problems are found:
Symptom
Door is binding

Suggested Action
a. Check that door and frame are properly aligned and door is free swinging. b. Check hinges: They should not be loose or have excessive wear on knuckles.

Bolt will not deadlock

a. Check for sufficient clearance of the bolt within the strike-side jamb. Correct this by increasing the depth of the pocket for the bolt. b. Check for misalignment of bolt and/or strike which may be preventing bolt from properly entering the strike. With the door open, extend and retract the bolt; if it is smooth, check the strike alignment.

Bolt does not extend or retract smoothly

a. Bolt and strike are misaligned, see above. b. Check the backset of door relative to adjustments already made to bolt. c. Verify proper door preparation and re-bore holes that are too small or misaligned. d. Verify keypad cable/connector is routed under the bolt (see Fig. A). e. Verify bolt is installed correct side up (Fig. A). .

Figure A

Yale Real Living™ locks are automatically handed. On startup, hold down the reset button and wait while the lock tests bolt operation. The default Master Pin Code must be changed before any other programming.

13
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Programming Troubleshooting
Symptom Lock does not respond – door is open and accessible. • • • • • • • • • • • PIN codes will not register. • • • • • Upon entering a PIN code and pressing the star (*) key, the lock gives a series of beeps, flashes red and blue LEDs seven times, and does not unlock. Upon entering a PIN code and pressing the (*) key, there are different tones. The unit operates, but it makes no sound. The unit displays intermittent RED flashes. Upon entering a PIN code and pressing the star (*) key, the unit responds with a series of beeps and the keypad flashes three times. • • Suggested Action Press each keypad button to see if they respond when pressed. Check batteries are installed and oriented correctly (polarity) in the battery case. Check batteries are in good condition; replace batteries* if discharged. Check to see if cable is fully connected and not pinched. Lock may be in Privacy mode (set from inside room). Mechanical key will grant access. Batteries may be completely discharged. • Use mechanical key to gain entry and replace batteries*. Check to see if there is another locking device on the door. Check the door gaps for any foreign objects between door and frame. Check that the cable is firmly connected to the PC board. Check to see if Auto Re-lock Mode is enabled. • Disable Auto Re-lock Mode to lock the door (automatically). If low battery indicator is lit (see below), change batteries*. PIN codes must consist of 4 to 8 digits to register. The same PIN code cannot be used for multiple users. Registration/management of PIN codes is set by the authority of the Master Code. • Contact the Master user User codes must be entered within 20 seconds or the process will have to be restarted. The star (*) or pound (#) cannot be used as part of the PIN code. Lockout Mode is enabled. Only the Master can enable/disable Lockout Mode. • Contact the Master user. Check to see if the lock is set to Lockout Mode. Setting/managing Lockout Mode is done through Master Code only. Contact the Master user. Enable Audio Mode. This is the Low Battery indicator alerting that it is time to replace the batteries. Replace all four (4) batteries* with new AA Alkaline batteries. The digits entered were incorrect or incomplete. Re-enter the correct code followed by the star key.

Lock does not respond – door is locked and inaccessible. Unit chimes to indicate code acceptance, but the door will not open. Unit operates to allow access, but will not automatically re-lock.

• • • • •

* When batteries are replaced, Network Module locks have a real time clock that will be set through the User Interface (UI); it is recommended to verify correct date and time particularly those locks operating under Daylight Saving Time (DST). ** Network Module locks only

14
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

Installing the Network Module
IMPORTANT: The batteries must be removed prior to removing and/or inserting the network module: • Remove batteries • Remove and/or insert network module • Reinstall batteries

Use feature programming step 7 (page 13) for enrollment of the Network Module.

15
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

How to Replace or Install Cylinder
1. Remove cylinder: A. Remove outside escutcheon from door. B. Remove rubber gasket. C. Remove two screws holding plastic guide in place. D. Remove plastic guide. E. Remove screw with washer holding cylinder in place (visible after plastic guide is removed). F. Remove cylinder by pulling towards the door side of escutcheon. Before installing cylinder, please be sure you have correct length tailpiece. 2. Install new cylinder: A. Reverse previous steps for removing cylinder.
D

A

B

C
E

F

Cylinder tailpiece information:
L
1-3/8"* to 2" thick doors, L = 3-1/2" (88.8mm) 2" to 2-1/4" thick doors, L = 3-3/4" (95.3mm)

Tailpiece

*Requires addition of Thin Door Kit.
w T

T = .098" (2.5mm) W = .2" (5.2mm)

16
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

PIN CODE MANAGEMENT SAMPLE SHEETS
PIN Code Management (No Network Module - Up to 25 Users) Location:
User Type User Name

Door Number:
User # PIN Code

User

User Name

User #

PIN Code

Master User 1 User 2 User 3 User 4 User 5 User 6 User 7 User 8 User 9 User 10 User 11 User 12

User 13 User 14 User 15 User 16 User 17 User 18 User 19 User 20 User 21 User 22 User 23 User 24 User 25

17
P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand

PIN Code Management (With Network Module - Up to 250 Users) - Duplicate Sheet to record entries
User Type User Name User # PIN Code User User Name User # PIN Code

Master User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___

User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___ User ___

18
P/N AYRD210-INST-FUL Rev B

An ASSA ABLOY Group brand

ONLINE LITERATURE AND TEMPLATES
For the latest information on Yale products visit our website at www.yalelocks.com. Click on the “Literature” button to find the most up-to-date catalogs, parts manuals, templates, specifications and installation instructions.

100 Yale Avenue, Lenoir City, TN 37771 • Product Support Tel 800.810.WIRE (9473) • www.yalelocks.com
Yale Locks & Hardware is a division of Yale Security Inc., an ASSA ABLOY Group company. Yale® is a registered trademark of Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Yale Real Living™ is a trademark of Yale Security Inc., an ASSA ABLOY Group company. Copyright © 2011, Yale Security Inc., an ASSA ABLOY Group company. All rights reserved. Reproduction in whole or in part without express written permission of Yale Security Inc., an ASSA ABLOY Group company is prohibited. YALE, with its unique global reach and range of products, is the world’s favorite lock — the preferred solution for securing your home, family and personal belongings. ASSA ABLOY is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience.

Yale Locks & Hardware

P/N AYRD210-INST-FUL Rev B
An ASSA ABLOY Group brand


Uploaded