Document Transcript

1
Copyright © 2018 Nortek Security & Control
Figure 2.
Opening the Detector Case
2GIG-FT6-345
FLOOD AND TEMPERATURE DETECTOR
DETECT
OR
DOUBLE SIDED
ADHESIVE
TAPE
LITHIUM BA
TTER
Y
LITHIUM
ALIGN DOTS
BATTERY TERMINAL
NEGATIVE (-)
BATTERY TERMINAL
POSITIVE (+)
Replacing Battery
1.
Open Detector Case (as shown in Figures 2 and 3).
2.
Remove old battery, and dispose of properly
(following state regulations).
3.
Install new battery.
4.
Close Detector Case.
INSTALLATION INSTRUCTIONS
The 2GIG-FT6-345 is a fully supervised, one-way 345 MHz detector. It will detect wet
or dry floor conditions as well as the ambient temperature. The detector reports wet/
dry conditions and when specific temperature thresholds are exceeded.
Flood Conditions
Once the detector probe detects the presence of water, the integral transmitter will
immediately send a loop 3 wet alarm transmission to the panel. The detector will also
send a restore (dry) report when the presence of water is no longer detected. The
detector is capable of detecting clean or dirty fresh water, salt water and tap water.
The 2GIG-FT6-345 utilizes a unique design that can detect leaks dripping onto its
top or if there is water under the device. This dual sensing technology is perfect for
placement under P Traps or hoses that may leak, giving a warning just as the leak
starts. If a leak occurs at a different location, it will also be detected when the water
is sensed under the device.
Temperature Conditions
Heat:
1.
If the temperature is more than 95° F (35°C) for three (3) minutes, the detector
will send a loop 2 transmission.
2.
If the temperature is less than 95°F (35°C) for three (3) minutes, the detector
will send a loop 2 clear.
Cold:
1.
If the temperature is less than 41°F (5°C) for three (3) minutes, the detector will
send a loop 1 transmission.
2.
In the temperature is more than 41°F (5°C) three (3) minutes, the detector will
send a loop 1 clear.
Contents
Verify that the package includes the following:

1 — 2GIG Flood/Temperature Detector

1 — 3V CR123A Lithium Battery (Installed)

1 — Double sided adhesive tape
Figure 1.
Temperature/Flood

Detector Contents
Grip the base of the detector case. Turn the top cover counter-clockwise to align the
dots, then separate the detector case.
Figure 3.
Installing New Battery
DETECTOR
WATER
Installing Water Detector
The 2GIG-FT6-345 Flood and Temperature Detector can be easily placed in any
location. If placed specifically under a potential leak source, use the included optional
double sided adhesive tape to secure it in the desired location (see
Figure 4
).
Figure 4.
Suggested Installation Locations
Place the detector in locations
that have the potential of
water leaks or flooding.
For example:

Under the sink pipes

Adjacent to water heaters

Adjacent to toilets

Adjacent to bathtubs or
showers

Under or near your
dishwasher

Near washer and dryer 2
Copyright © 2018 Nortek Security & Control
2GIG Flood & Temperature Control Instruction Manual
Flood/Temperature Specifications
REGULATORY INFORMATION
This equipment has been tested and found to comply with the limits for Class B Digital Device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates and can
radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interference by one or more of the
following measures.
Reorient or relocate the receiving antenna
Increase the separation between the equipment and receiver
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
Le présent appareil est conforme aux CNR d’Industrie Canada applicables aux appareils radio
exempts de licence. Ľexploitation est autorisée aux deux conditions suivantes: (1) ľappareil
ne doit pas produire de brouillage, et (2) ľutilisateur de ľappareil doit accepter tout brouillage
radioélectrique subi, même si le brouillage est susceptible ďen compromettre le fonctionnement.
FCC COMPLIANCE STATEMENT
This device complies with FCC Rules and Regulations as Part 15 devices as well as Industry
Canada license exempt RSS Rules and Regulations. Operation is subject to the following two
(2) conditions: This device may not cause harmful interference. This device must accept any
interference received, including interference that may cause undesired operation.
INDUSTRY CANADA (IC) COMPLIANCE
This device complies with Industry Canada license‐exempt RSS standard(s). Operation is subject
to the following two conditions: (1) this device may not cause interference, and (2) this device
must accept any interference, including interference that may cause undesired operation of the
device. Repairs to certified equipment should be made by an authorized Canadian maintenance
facility designated by the supplier. Any repairs or alterations made by the user to this equipment,
or equipment malfunctions, may give the telecommunications company cause to request
the user to disconnect the equipment. Users should ensure for their own protection that the
electrical ground connections of the power utility, telephone lines and internal metallic water pipe
system, if present, are connected together. This precaution may be particularly important in rural
areas. Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
LIMITED WARRANTY
This Nortek Security & Control LLC product is warranted against defects in material and
workmanship for two (2) years. This warranty extends only to wholesale customers who buy
direct from Nortek Security & Control LLC or through Nortek Security & Control normal distribution
channels. Nortek Security & Control does not warrant this product to consumers. Consumers
should inquire from their selling dealer as to the nature of the dealer’s warranty, if any.
There are no obligations or liabilities on the part of Nortek Security & Control for consequential
damages arising out of or in connection with use or performance of this product or other indirect
damages with respect to loss of property, revenue, or profit, or cost of removal, installation, or
reinstallation. All implied warranties for functionality, are valid only until the warranty expires.
This Nortek Security & Control Warranty is in lieu of all other warranties expressed or implied.
Operating Temperature:
32
°
to 104
°
F (0
°
to 40
°
C)
Operating Rel. Humidity:
5 to 95%, non-condensing
Operating Frequency:
345 MHz
Battery Type:
CR123A 3V lithium battery
Projected Battery Life:
5 Years
Supervisory Interval
70 Minutes
MET
AL CONT
ACTS
(TOP)
MET
AL CONT
ACTS
(BOTTOM)
DOUBLE SIDED
ADHESIVE
TAPE
Flood Detector Operation
Metal contacts on the top and bottom of the detector can detect the presence
of water. Be certain to place the detector in a manner that does
not impede the
detector’s ability to detect water.
NOTE:
Do not place on a metal or conductive
surface.
Figure 5.
Flood Detector Contacts
Securing the Detector
In areas where the detector could be accidentally moved, secure the detector in
place with the provided double sided adhesive tape.
NOTE:
Make sure you secure the tape without covering any of the three metal
contacts.
Figure 6.
Detector Double Sided Adhesive Tape Application
Nortek Security & Control LLC | 2GIG
5919 Sea Otter Place, Suite 100
Carlsbad, CA 92010 USA
For technical support in the USA and Canada:
855-2GIG-TECH (855-244-4832)
Email:

2gigtechsupport@nortekcontrol.com
Visit
www.nortekcontrol.com
for technical support hours of operation.
For technical support outside of the USA and Canada:
Contact your regional distributor.
Visit
www.2gig.com/dealers/
for a list of distributors in your region.
10021591 A


Uploaded