5193 Series VPlex Smoke - Data Sheet
Related Products
Related Categories
Document Transcript
Docement ID L/5193SDT/D Dated: June, 2015
Honeywell’s V-Plex Addressable Photoelectric Smoke Detectors are designed to provide open area protection and to be
used with compatible UL or ULC-listed Honeywell control panels that support V-Plex technology. The detectors incorporate
a state-of-the-art optical sensing chamber and an advanced microprocessor. Built-in Drift Compensation algorithms
automatically maintain proper operation at factory calibrated detection levels, even when sensitivity is altered due to
the presence of contaminates settling into the unit’s chamber. The 5193SDT/A also features a restorable, built-in, fixed
temperature (135°F/57.2°C) thermal detector.
•
Easy Installation:
Installation is simplified by the use of
a mounting base that may be pre-wired to the system,
allowing the detector to be easily installed or removed for
maintenance or service. (See Figure 1).
•
LED Status Indicators:
Two LEDs (green and red) provide
local visual indication of the detector’s status – including
normal operation, alarm, out of sensitivity and trouble
conditions.
•
Test button:
This button allows the user to perform periodic
testing of the detector’s circuitry and verify that the detector
is within the sensitivity limits.
•
Versatile Mounting:
Mounting is made simple with the
included hardware and the large mounting ports, which
accommodate drywall anchors for easy surface mounting.
(See Figure 1).
•
Tamper Protection and Tamper Resistance:
The detector
contains a built-in tamper switch that can communicate
back to the control panel in the event the detector is
removed from its base. For an added level of security,
the detector also includes a tamper resistant element that
prevents removal from the base without the use of tools.
(See Figure 1).
FEATURES
5193 Series
V-PLEX
®
ADDRESSABLE SMOKE DETECTOR
Figure 1: Tamper-Resistant Feature/Wiring
SNAP
OFF
TA
B
FOR
TA
MPER LOCK
TA
MPER
RELEASE
TA
B
DIRECT
MOUNT
HOLES L/5193SDT/D
June 2015
© 2015 Honeywell International Inc.
Automation and Control Solutions
Honeywell Security Products Americas
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
1.800.467.5875
www.honeywell.com
ORDERING
5193SD
Addressable Photoelectric Smoke Detector
5193SDT
Addressable Photoelectric Smoke Detector with Integral Heat Sensor
5193SDTA
Addressable Photoelectric Smoke Detector with Integral Heat Sensor (Canada Only)
Accessory sold separately:
SENS-RDR
Handheld Sensitivity Reader
SPECIFICATIONS
5193 Series
V-PLEX
®
ADDRESSABLE SMOKE DETECTOR
•
Heat Sensor:
(Model 5193SDT/A):
135°F (57.2°C);
Fixed Temperature Electronic Thermistors
•
Operating Ambient Temperature Range:
32° to 100°F (0° to 38°C)
•
Operating Humidity Range:
0 to 95% RH non-condensing
•
Storage Temperature Range:
-4° to 158°F (-20° to 70°C)
•
Diameter (including base):
5.3 inches (13.46 cm)
•
Height (including base):
2.0 inches (5.08 cm)
•
Weight:
6.3 oz. (178.6 g)
•
Agency Listing:
UL 268; CAN/ULC S531
•
System Voltage Range:
7-14V
•
Standby Current
(maximum @ 12V)
LED off: 1.2mA
LED on: 2.8mA
To measure the detector’s sensitivity, the SENS-RDR Infrared Sensitivity Reader tool (sold separately) should be used.
It reduces testing time, simplifies sensitivity measurements and displays them precisely in terms of percent per foot obscuration.
The SENS-RDR eliminates the need for magnets, voltmeters and ladders.
ACCESSORY
(sold separately)
Figure 2: Position of Reader
OR