Emergency Call Button with 2GIG Transmitter
Specifications
SKU
ADC-EPB-BC2.1-HW
Enclosure
4.75 in. x 2.25 in. (Diameter x Depth) Black, ABS plastic
base with slip-resistant feet and 3 x AAA battery housing
for an optional audible message on button press Red,
ABS plastic, spring-loaded push button
Electronic Signaling
Battery-powered filter circuit with integrated 345 MHz
(crystal-controlled) 2GIG-compatible transmitter with
64-minute supervisory interval
Sensing Interface
Filtered, normally open (i.e. when not pressed),
momentary contact switch
Battery Life
Replaceable 3x AAA battery: 2+ years
Programming
1.
Use the Alarm.com AirFX “Add a Sensor” interface or the panel interface to add the button to the account. Set the
“New Sensor Information” as shown in the chart.
◦
Please note that “Alarm type 24hr aux Alarm” should be used if the button is used to signal an emergency.
◦
“Alarm type no response” can be used if the button is not being used to signal an emergency.
2.
After the sensor is added to the system, change the sensor type to “Push Button.”
◦
From the
Equipment
page of the Dealer
Website click
Change
to the right of the sensor’s name.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Emergency_Call_Button/Emergency_Call...
Updated: Mon, 23 Sep 2019 21:14:27 GMT
1 ◦
Select the “Change Sensor Type” action, and update the new sensor type to “Push Button".
Sensor ID
(Select an unused ID)
Sensor Type
Alarm type 24hr aux Alarm (Emergency) or Alarm type
no response (Non-Emergency)
Equipment Type
Contact
Equipment Code
491
Serial Number
(On the bottom of the device)
Equipment Age
New
Sensor Loop Number
2
Dialer Delay
(Any)
Voice Descriptor
(Any)
Reports
Enabled
Supervised
Enabled
Chime
(Any)
Installation
Locate the sensor within 100 feet of the base station. Ensure that the On/Off switch on the base of the button is set to
the “On” position. The sensor can be mounted using the included mounting plate and mounting hardware or simply
place the sensor on a flat surface in a visible location.
Tamper
Note that the device may signal a tamper if the button is pressed within the first two seconds after the on/off switch is set
to the “On” position.
Use
Press and hold the switch for one second.
https://answers.alarm.com/ADC/Partner/Installation_and_Troubleshooting/Wellness/Emergency_Call_Button/Emergency_Call...
Updated: Mon, 23 Sep 2019 21:14:27 GMT
2
- Uploaded