AlarmNet Communicator ECP Status Codes
Related Products
Related Categories
Document Transcript
Technical Support
Step
-By
-Step
Created on 08/29/06
Page 1 of 1
Communicator
ECP Status Codes
When the Communicator
is configured for ECP mode, it sends status messages to the control
panels
for battery, power, tamper, and network connectivity failures. Some of the control
panels, (e.g.,
VISTA
-10P, VISTA
-15P and VISTA
-20P Series) display these on the keypad as
“LngRng Radio”
followed by a 4-
digit code
. In addition, the C
ontact ID
codes for these conditions are sent to the
central station by the
module.
ECP Keypad Displays Status Codes
STATUS CODE
DESCRIPTION
0000
Co
ntrol panel lost communication with 7845i
-GSM.
0880
Communicator
tamper detected (cover removed).
0005
Communicator
has lost contact with AlarmNet
-G network.
4005
Communicator
has lost contact with AlarmNet.
000F
Communicator
is not registered; accou
nt not activated.
0019
Communicator
shutdown.
0400
Communicator
power
-on reset AND the panel lost communications with
Communicator
0C80
Communicator
power on reset AND tamper detected.
0C8F
Communicator
power on reset AND tamper detected AND not reg
istered.
08E0
Communicator
tamper detected and 7845i
-GSM battery low.
3000
Primary power loss (will only be displayed in conjunction with another event).
8000
Battery charger failure (will only be displayed in conjunction with another
event).
0060
Low battery (will only be displayed in conjunction with another event).
Central Station Messages
- Uploaded