DSC AMP-701 - Installation Manual



Related Products

DSC AMP-701 - Addressable Contact Input Module
DSC AMP-701
Addressable Contact Input Module
List Price: $58.00
Our Price: $41.99

Related Categories


Document Transcript

AMP-701
Addressable Contact Input Module
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
FCC COMPLIANCE STATEMENT
CAUTION:
Changes or modifications not expressly approved by Digital Security Controls Ltd.
could void your authority to use this equipment.
This equipment generates and uses radio frequency energy and if not installed and used properly, in
strict accordance with the manufacturer’s instructions, may cause interference to radio and televi-
sion reception. It has been type tested and found to comply with the limits for Class B device in
accordance with the specifications in Subpart “B” of Part 15 of FCC Rules, which are designed to
provide reasonable protection against such interference in any residential installation. However,
there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause interference to television or radio reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:

Re-orient the receiving antenna

Relocate the alarm control with respect to the receiver

Move the alarm control away from the receiver

Connect the alarm control into a different outlet so that alarm control and receiver are on different
circuits.
If necessary, the user should consult the dealer or an experienced radio/television technician
for additional suggestions. The user may find the following booklet prepared by the FCC
helpful: “How to Identify and Resolve Radio/Television Interference Problems”. This booklet
is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock #
004-000-00345-4.
© 1998 Digital Security Controls Ltd.
1645 Flint Road, Downsview, Ontario, Canada M3J 2J6
Tel. (416) 665-8460 • Fax (416) 665-7498
Printed in Canada 29003073 R0
Limited Warranty
Digital Security Controls Ltd. warrants that for a period of twelve months from the
date of purchase, the product shall be free of defects in material and workmanship
under normal use and that in fulfillment of any breach of such warranty, Digital
Security Controls Ltd. shall, at its option, repair or replace the defective equipment
upon return of the equipment to its repair depot. This warranty applies only to
defects in parts and workmanship and not to damage incurred in shipping or
handling, or damage due to causes beyond control of Digital Security Controls Ltd.
such as lightning, excessive voltage, mechanical shock, water damage, or damage
arising out of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in
lieu of any and all other warranties, whether express or implied and of all other
obligations or liabilities on the part of Digital Security Controls Ltd. This warranty
contains the entire warranty. Digital Security Controls Ltd. neither assumes, nor
authorizes any other person purporting to act on its behalf to modify or to change this
warranty, nor to assume for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct , indirect or
consequential damages, loss of anticipated profits, loss of time or any other losses
incurred by the buyer in connection with the purchase, installation or operation or
failure of this product.
Warning
Digital Security Controls Ltd. recommends that the entire system be completely
tested on a regular basis. However, despite frequent testing, and due to but not
limited to, criminal tampering or electrical disruption, it is possible for this product
to fail to perform as expected.
The AMP-701 contact uses a 2-wire connection for power and to
communicate with the control panel. This, in combination with low power
devices, simplifies wiring and reduces device count for efficient installations.
The AMP-701 has three alarm input terminals to which an external device
can be connected. The terminals monitor alarm, tamper and trouble
states. Use only devices with NC dry contact outputs. The use of any
other type of device will impair the operation of the AMP-701.
Specifications
Current Rating ....................................................................................
0.8mA
Operating Environment ....................................... 0°C - 49°C (32°F - 120°F)
.................................................................... 5% - 95% RH, non-condensing
Size (H x W x D) .................................. 27 x 85 x 19mm / 1
1
/
16
x 3
3
/
8
x
3
/
4
in.
Control Panel Compatibility
PC4010/4020 v3.0
Connection Diagram
Run the connection wires through the wiring holes on the back of the unit.
Mounting
To mount the unit, remove the plastic cover and secure the unit to the
desired location with the screws provided. Replace the cover.
Device Enrollment
The serial number located on the back of the device must be enrolled into
the alarm control panel via Installer’s Programming ([
Q
] [8] [Installer’s
Code]). This procedure is outlined for the PC4010/4020 v3.0 in the control
panel Installation Manual.
WARNING: Connect only DSC Addressable Series devices to the
addressable loop connections. Connection of ANY other type of device will
impair operation. Any devices other than Addressable Series devices
which require power to operate must be powered separately.


Uploaded