ELK-319PIRC Wireless Ceiling Mount PIR Sensor
Description
The ELK-319PIRC is a Supervised, Wireless 360° degree
PIR (passive infrared) Motion Sensor designed specifically for
ceiling mount applications.
When motion is sensed in the field of view the sensor will
transmit a violation (trip) signal to the panel. Additionally
transmitted signals include: tamper, hourly supervisory, and
low battery (as needed). The sensor is powered by two (2)
replaceable 3VDC lithium batteries.
This sensor is compatible with Elk’s 319MHz Receivers/Panels
as well as many other panels that operate on the 319.5MHz
Frequency and adhere to the ITI/Interlogix protocol.
Specifications
RF frequency:
319.5 MHz
Compatibility:
ELK-319 Receivers/Panels & other panels

that operate on the 319.5MHz Freq. and

adhere to the ITI/Interlogix protocol
Battery type:
Two (2) 3VDC lithium battery

(Panasonic CR123)
Tamper Switch:
Sealed dome-contact
Sensitivity:
Selectable 2 event or 3 event
Operating Temp:
-40 to 131°F (0 to 49°C)
Storage Temp:
-30 to 140°F (-34 to 60°C)
Max. Humidity:
90% Relative Humidity non-condensing
Dimensions
2.95” Diameter x 1.39” depth
Programming (Enrollment)
The following is a general guideline for programming (enrolling)
a sensor into the receiver or panel. For more extensive
instructions please refer to the receiver or panel instructions.
1. Place the panel into the Program mode.
2. Proceed to the WIRELESS SETUP menu.
3. Select the appropriate zone/sensor location number.
4. When the panel prompts to trip the sensor do the following:
• Separate sensor from the mounting base
• Remove battery pull tabs (if present) to power the sensor
• The panel should acknowledge sensor has been learned
by a display on the keypad and/or audio alert (depending
on the panel). If enrollment does not succeed repeat the
process by removing and reinstalling the battery OR try
pressing and releasing the tamper plunger.
5. For additional sensors of this type repeat the above process.
Proceed to the zone programming to assign each sensor’s
zone definition.
IMPORTANT: Set the Zone Loop as “1” for
this sensor.
6. Exit the panel Program mode when finished.
Coverage Pattern and Mounting Height
Coverage pattern is dependent on the mounting height of
the sensor. If required areas can be masked off to prevent
unwanted detection in the 360° field of vision.
Mounting Height
Detection Area
8 ft
14 ft
10 ft
25 ft
12 ft
40 ft
TM
Interlogix is a registered trademark belonging to United Technologies.
Lo Sensitivity - 3 event - place jumper on top two pins
Hi Sensitivity - 2 event - place jumper on bottom two pins
LED - jumper installed across pins for visual walk test
Installation Guidelines
Sensor is designed for ceiling mount applications that provide
a 360° field of view.
• Do not install on a sloped ceiling/surface.
• Maximum mounting height is 12ft.
• Do not mount outdoors
20
 
(6)
    
12.5
 
(4)
   
6.5
 
(2)
    
0
   
6.5
 
(2)
   
12.5
 
(4)
   
20
 
(6)
                              
Diameter
   
ft
  
(m)
Height
  
ft
 
(m)
     
8
 
ft
 
(2.4m)
      
10
 
ft
 
(3m)
   
12
 
ft
 
(3.6m)
Dia.
  
ft
 
(m)
20
 
ft
 
(6m)
12.5
 
ft
 
(4m)
6.5
 
ft
 
(2m)
0
6.5
 
ft
 
(2m)
12.5
 
ft
 
(4m)
20
 
ft
 
(6m)
Tamper
Sensitivity
J70
S2
LED
Lo
Hi Elk Products, Inc.- 3266 Hwy 70 - Connelly Springs, NC 28612 http://www
.elkproducts.com
2/11/2019
Limited Warranty
THIS WIRELESS SENSOR IS WARRANTED TO BE FREE FROM
DEFECTS AND WORKMANSHIP FOR A PERIOD OF 2 YEARS
FROM DATE OF MANUFACTURE EXCLUDING BATTERIES.
BATTERIES USED WITH WIRELESS DEVICES ARE NOT
WARRANTED.
MANUFACTURER HEREBY DISCLAIMS ANY AND ALL OTHER
WARRANTIES AND REPRESENTATIONS, WHETHER EXPRESS,
IMPLIED, STATUTORY OR OTHERWISE INCLUDING (BUT NOT
LIMITED TO) ANY WARRANTIES OF MERCHANTABILITY OR
FITNESS FOR A PARTICULAR PURPOSE WITH RESPECT
TO THESE PRODUCTS AND ANY RELATED SOFTWARE.
MANUFACTURER FURTHER DISCLAIMS ANY OTHER IMPLIED
WARRANTY UNDER THE UNIFORM COMPUTER INFORMATION
TRANSACTIONS ACT OR SIMILAR LAW AS ENACTED BY
ANY STATE. (USA only) SOME STATES DO NOT ALLOW THE
EXCLUSION OF IMPLIED WARRANTIES, SO THE ABOVE
EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE
OTHER LEGAL RIGHTS THAT VARY FROM STATE TO STATE.
MANUFACTURER MAKES NO REPRESENTATION, WARRANTY,
COVENANT OR PROMISE THAT ITS ALARM PRODUCTS
AND/OR RELATED SOFTWARE (I) WILL NOT BE HACKED,
COMPROMISED AND/OR CIRCUMVENTED; (II) WILL PREVENT,
OR PROVIDE ADEQUATE WARNING OR PROTECTION FROM,
BREAK-INS, BURGLARY, ROBBERY, FIRE; OR (III) WILL WORK
PROPERLY IN ALL ENVIRONMENTS & APPLICATIONS.
NOTE: Elk Products is not responsible for any changes
or modifications not expressly approved by the party
responsible for compliance. Such modifications could
void the user’s authority to operate the equipment.
FCC AND IC COMPLIANCE STATEMENT:
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency
energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference
will not occur in a particular installation.
If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:

Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

This device complies with Industry Canada license-exempt RSS
standard(s). Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must
accept any interference, including interference that may cause
undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de
licence standard RSS (s). Son fonctionnement est soumis aux
deux conditions suivantes: (1) cet appareil ne doit pas provoquer
d’interférences et (2) cet appareil doit accepter toute interférence,
y compris celles pouvant causer un mauvais fonctionnement de
l’appareil.
In accordance with FCC requirements of human exposure to radio
frequency fields, the radiating element shall be installed such that
a minimum separation distance of 20 cm is maintained from the
general population.
FCC ID: 2ABBZ-RF-CPIR
IC: 11817A-RFCPIR
This device complies with Part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation. Changes or modifications not expressly
approved by the party responsible for compliance could void the
user’s authority to operate the equipment.
This Class B digital apparatus complies with Canadian ICES-3B.
Cet appareil numérique de la classe B est conforme à la norme
NMB-003 du Canada.
• Avoid areas with pets
• Do not mount near ceiling fans or heating ducts•
Do not mount on metal surfaces as this reduces range.
• Avoid sensor looking directly at window or direct sunlight.
• Install sensor within 100 ft. of the receiver or panel.
• Surface must be solid with no vibration or movement.
Mounting
• Twist sensor counter clockwise to remove from mounting
base.
• Attach base to ceiling with screws and
anchors.
• Twist sensor on base. Use caution to
avoid bending tamper plunger spring.
Operation and Testing
[ 3 minute lockout ]
To conserve battery life sensor has a 3-minute sleep mode
lockout between motion detections and transmission.
For walk testing the 3-minute lockout may be avoided by
removing sensor from its base and tripping the tamper. Sensor
will now detect and transmit to receiver with each motion detect.
Visual LED may be enabled by placing jumper across LED pins.
Immediately place sensor back onto its base and walk test
coverage area.
After 1 minute of no motion detection the walk test mode will
timeout and end.
We recommend removing the LED enable jumper after walk
testing so that battery life will be prolonged.
Battery Life and Replacement
Battery life depends on temperature of environment and how
often sensor transmits signals. Sensor transmits a low battery
indication to panel when it detects the battery voltage is low.
Replace both batteries as soon as possible.
• Twist sensor counter clockwise to remove from base.
• Carefully remove both batteries from their holders.
• Insert two (2) new batteries into the holders observing (+)
polarity marked on the batteries and the circuit board.
CAUTION: Use only the following approved Lithium
Battery: Panasonic CR123 3V
• Replace sensor onto the mounting base.
CAUTION: Battery may explode if mistreated. Do not re
-
charge, disassemble, incinerate or expose to heat above
212° F (100° C). Keep away from children.
Battery Disposal
The batteries used in this sensor are lithium batteries
and are not reuseable. Dispose of used lithium batteries
according to your local hazardous waste disposal laws.