First Alert Pro VISTAHTKVRWL - Compatibility List - Dated 11/24 Rev. A
Related Products
Related Categories
Document Transcript
VISTAHTKVRWL
Wireless
Converter
Communications
Module
VISTAHTKVRWL
Compatibility
The
VISTAHTKVRWL
module
is
compatible
with
the
brands
and
model
numbers
listed
in
the
f ollowing
table
and
is
f or
use
with
the
First
Alert
Pro
Hybrid
Control
Panels.
Special
enrollment
requirements
f or
the
applicable
modules
are
also
provided.
The
Sensors
are
enrolled
or
“learned”
into
the
system
using
the
AlarmNet
360
(AN360)
programming
Tool
(www.alarmnet360.com)
using
the
“Add
New
Sensor”
programing
option
or
via
the
panel's
Local
Programming
mode.
The
sensors
can
be
enrolled
via
RF
Learn
-
ing
or
by
manually
by
entering
the
serial
number.
AN360
Programming
Select
Sensor
Type
5800
or
Takeover
f rom
the
drop-
down
options.
When
entering
manually,
AN360
will
accept
a
maximum
of
seven
digits
and
will
not
accept
special
characters.
Once
enrolled,
certain
sensors
require
the
programming
of
additional
attributes
as
noted
in
the
accompanying
table.
Af ter
entering
AN360,
Select
Sensors>
Add
sensor
>
Learn
>
Fault
sensor
>
Enter
Loop
number
>
Enter
device
type
>
Zone
type
>
Save
or
Save
and
Add
Another
Note:
For
devices
that
support
more
than
one
loop,
AN360’s
add
service/ loop
option
is
used
to
add
additional
loops.
Local
Programming
To
access
the
local
programming
mode,
select
the
Menu
icon
on
the
home
screen,
then
select
Tools
>
enter
4-
digit
installer
code
(def ault
4112)
>
Select
"Programming".
Then
select
Peripherals
>
Tap
the
+
sign
>
Activate
the
Sensor
(as
noted
in
the
accompanying
table)
>
Select
the
proper
Loop,
Device
Type
and
Response
Type.
Note:
The
applicable
brand
protocol
must
be
selected
on
the
VISTAHTKVRWL
module.
(The
options
include
5800,
2GIG,
DSC,
ITI/ Qolsys
and
Bosch.)
Using
devices
not
listed
here
as
compatible
is
not
recommended
and
may
cause
unexpected
behavior.
Honeywell
Devices
5800CO
Sensor
Type:
Carbon
Monoxide
Detector
with
Built-
in
Wireless
Transmitter
Enrollment
Process:
Enroll
by
tripping
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Carbon
Monoxide
detector
l
Response
type
=
Carbon
Monoxide
Note:
CO
Alarms
Troubles
Conditions
(including
End
of
Lif e)
are
reported
on
one
zone.
5800MINI
Sensor
Type:
Mini
Door/ Window
Transmitter
Enrollment
Process:
Open
the
magnetic
contact
f or
2
seconds.
Close
the
contact.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5806W3
Sensor
Type:
Photoelectronic
Smoke
Detector
with
Built-
in
Wireless
Transmitter
Enrollment
Process:
Enroll
by
tripping
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Smoke
l
Response
type
=
Fire
No
Verif ication
or
Fire
Verif ication
Note:
Smoke
Alarms
and
Troubles
Conditions
(including
Smoke
Maintenance)
are
reported
on
one
zone. HoneywellHome/ Resideo
Devices
5800C2W
Sensor
Type:
Convert
to
Wireless
Module
NOTE:
The
5800C2W
must
be
calibrated
bef ore
enrollment.
See
instructions
f or
calibration
steps.
5800C2W
supports
Tamper
and
Low
Battery
trouble
reporting
on
the
lowest
calibrated
zone.
E.g.,
If
Zone
1-
6
is
calibrated
and
enrolled,
then
5800C2W
Tamper
would
report
on
the
panel
as
a
tamper
on
zone
1
only.
PLEASE
NOTE:
Instructions
mention
enrolling
zones
as
loop
4;
this
is
not
supported
on
ProSeries
Panels,
as
loop
4
is
enrolled
auto
-
matically.
Enrollment
Process:
There
are
2
methods
of
enrollment:
Method
1:
1.
Enter
learning
mode
on
the
panel
2.
Trip
zone
to
be
learned
3.
Panel
will
chime
to
indicate
it
detected
the
zone.
4.
Choose
the
appropriate
device
and
response
type
f or
the
zone
and
make
sure
it
is
loop
1.
5.
Repeat
steps
2-
4
f or
each
zone
to
enroll.
Method
2:
1.
Enter
manual
sensor
enrollment
mode
on
the
panel.
2.
Determine
the
serial
number
of
5800C2W.
The
zone's
serial
number
to
be
enrolled
is
Zone
#
+
the
serial
number
of
the
5800C2W.
E.g.,
if
the
5800C2W
serial
is
012340,
zone
1
of
5800C2W
is
012341,
Zone
2
is
012342,
etc.
3.
Enter
that
serial
number
into
the
panel,
choose
the
appropriate
device
and
response
type,
and
ensure
it
is
loop
1.
5800COMBO
Sensor
Type:
Combination
Smoke/ Carbon
Monoxide
(CO)
Detector
Smoke
Detector:
Serial
#1
l
Loop
1
=
Smoke/ Heat
l
Loop
3
=
Low
Temp
Press
Add
Loop/ Sensor
to
use
multiple
zones.
l
CO
Detector:
Serial
#2
l
Loop
1
=
CO
Detection
Enrollment
Process:
Smoke
Enrollment:
Leave
tamper
f aulted
and
enroll
Smoke
serial
number
by
pressing
the
Smoke
Test
button
f or
2
seconds.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Smoke
(Smoke/ Heat)
l
Response
type
=
Fire
No
Verif ication
or
Fire
Verif ication
Note:
Smoke/ Heat
Alarms
and
Troubles
Conditions
(including
Smoke
Maintenance)
are
reported
on
one
zone.
CO
Enrollment:
Leave
tamper
f aulted
and
enroll
CO
serial
number
by
pressing
the
CO
Test
button
f or
2
seconds.
In
AN360
or
Local
Pro
-
gramming
enter:
l
Loop
number
=
1
l
Device
type
=
Carbon
Monoxide
detector
l
Response
type
=
Carbon
Monoxide
Note:
CO
Alarms
and
Troubles
Conditions
(including
CO
End
of
Lif e)
are
reported
on
one
zone.
5800MICRA
Sensor
Type:
Wireless
Recessed
Transmitter
Enrollment
Process:
Open
the
magnetic
contact
f or
2
seconds.
Close
the
contact.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit 5800RP
Sensor
Type:
Wireless
Repeater
Module
There
are
two
methods
of
enrollment:
Combined
Trouble
Reporting
that
combines
the
Tamper,
AC
Loss,
Low
Battery,
and
RF
Jam
into
one
zone.
Note:
AC
Loss
and
RF
JAM
show
as
Low
Battery
on
the
control
panel.
Individual
Trouble
Reporting
that
reports
Tamper,
AC
Loss,
Low
Battery,
and
RF
Jam
in
f our
separate
zones.
Enrollment
Process:
Combined
Trouble
Reporting:
Tamper,
AC
Loss,
Low
Batt,
and
RF
Jam
all
report
in
1
zone.
1.
Set
DIP
switch
2
to
OFF
2.
Either
tamper
the
5800RP
f or
panel
to
automatically
learn
serial
number
or
enter
serial
number
of
5800RP
manually.
3.
Enroll
5800RP
as
l
Device
Type:
Other
l
Response
Type:
24HR
AUX
l
Supervised
l
Loop1
4.
Ensure
DIP
Switch
2
remains
OFF
f or
operation
Individual
Trouble
Reporting:
1.
Set
DIP
switch
2
to
OFF
2.
Either
tamper
the
5800RP
f or
the
panel
to
automatically
learn
the
serial
number
or
manually
enter
the
serial
number
of
the
5800RP.
3.
Enroll
this
zone
as:
l
Device
Type:
Other
l
Response
Type:
24HR
AUX
l
Supervised
l
Loop1
4.
Set
DIP
Switch
2
to
ON
5.
Either
tamper
the
5800RP
f or
the
panel
to
automatically
learn
the
second
serial
number
or
manually
enter
the
serial
number
of
the
5800RP
PLUS
1
manually.
6.
Enroll
3
zones
on
this
serial
number:
l
Tamper
Zone
o
Device
Type:
Other
o
Response
Type:
Day/ Night
o
Unsupervised
o
Loop
1
l
AC
Loss Zone
o
Device
Type:
Other
o
Response
Type:
24HR
AUX
o
Unsupervised
o
Loop
2
l
RF
Jam
Zone
o
Device
Type:
Other
o
Response
Type:
24HR
AUX
o
Unsupervised
o
Loop
3
7.
Ensure
DIP
Switch
remains
ON
f or
operation 5808W3/ 5800SMOKEV
Sensor
Type:
Photoelectronic
Smoke/ Temperature
Detector
with
Built-
in
Wireless
Transmitter
l
Loop
1
=
Smoke
l
Loop
3
=
Low
Temp
Press
Add
Loop/ Sensor
to
use
multiple
zones.
Enrollment
Process:
Smoke
Enrollment:
Enroll
by
tripping
the
tamper
and
enroll
Smoke
serial
number
by
pressing
the
Smoke
Test
button
f or
2
seconds.
For
Smoke
in
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Smoke
(Smoke/ Heat)
l
Response
type
=
Fire
No
Verif ication
or
Fire
Verif ication
Note:
Smoke
Alarms
and
Troubles
Conditions
(including
Smoke
Maintenance)
are
reported
on
one
zone.
For
Freeze
in
AN360
enter:
l
Loop
number
=
3
l
Device
type
=
Temperature
l
Response
type
=
24
Hour
Auxiliary,
Monitor
or
Trouble
5811
Sensor
Type:
Door/ Window
Transmitter
Enrollment
Process:
Open
the
magnetic
contact
f or
2
seconds.
Close
the
contact.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5814
Sensor
Type:
Window
Ultra
Small
Transmitter
Enrollment
Process:
Open
the
magnetic
contact
f or
2
seconds.
Close
the
contact.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5815/ 5815WG
Sensor
Type:
Door/ Window
Transmitter
Enrollment
Process:
For
the
hardwire
loop,
open
the
contact
f or
2
seconds
and
close
the
contact.
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close
the
contact.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
(terminals)
or
2
(reed)
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5816/ 5816OD
Sensor
Type:
Door/ Window
Transmitter
Outdoor
Wireless
Contact
Transmitter
Enrollment
Process:
For
the
Reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close
the
contact
f or
2
seconds.
Press
Add
Loop/ Sensor
to
use
mul
-
tiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
(terminals)
or
2
(reed)
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit 5817XT
Sensor
Type:
Three
Zone
Wireless
Transmitter
Enrollment
Process:
For
any
hardwire
loop,
open
the
contact
f or
2
seconds
and
close
the
contact.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5817CBXT
Sensor
Type:
Three
Zone
Commercial
Fire/ Burg
Transmitter
IMPORTANT!!
When
selecting
“Smoke”
or
"Heat"
as
Device
Type
on
Loop
1,
Maintenance
Loop
2
will
automatically
be
enabled;
do
not
use
or
program
Loop
2
f or
this
serial
number.
When
using
a
5817CB/ CBXT
if
Loop
1
is
“Smoke”
or
"Heat"
or
"Carbon
Monoxide"
Device
Type,
Loop
2
MUST
be
closed
with
a
jumper
or
magnet,
meaning
Loop
2
cannot
be
used.
Enrollment
Process:
DIP
switch
#1
must
be
of f
during
enrollment.
For
the
supervised
hardwire
loop,
short
the
contact
f or
2
seconds
and
restore
the
470kohm
resistance
f or
2
seconds.
For
the
unsupervised
hardwire
loop,
open
contact
f or
2
seconds
and
close
the
contact.
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close
the
contact.
For
tamper,
no
tripping
is
needed.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Heat,
Door
or
Window
l
Response
type
=
Fire
or
Perimeter
5819S
Sensor
Type:
Wireless
Shock
Sensor
Enrollment
Process:
Enroll
by
f aulting
and
restoring
Loop
1
(shock),
Loop
2
(magnet/ reed),
Loop
3
(terminal)
Shock
the
sensor,
open
the
magnetic
contact
or
short
the
terminal
with
a
wire
as
applicable.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Shock,
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
5820L
Sensor
Type:
Slim
Line
Transmitter
Enrollment
Process:
Open
the
magnetic
contact
f or
2
seconds
and
close
the
contact.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit 5821
Sensor
Type:
Flood/ Temp
Detector
l
Loop
1
=
Low
Temp
l
Loop
2
=
High
Temp
l
Loop
3
=
Water
Sensor
Enrollment
Process:
Enroll
remote
f lood
detector
only
by
f aulting
and
restoring
the
case
tamper.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
Note:
Do
not
enroll
more
than
1
loop.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Flood
or
Temp
l
Response
type
=
Monitor
or
Auxiliary
5822T
Sensor
Type:
Garage
Door
Tilt
Sensor
l
Loop
1
=
Contact
Terminals
l
Loop
3
=
Tilt
Sensor
Enrollment
Process:
For
the
tilt
loop,
f ault
the
5822T
by
rotating
the
device
to
simulate
garage
door
movement
to
the
open
position
and
holding
it
f or
2
seconds.
Restore
it
by
returning
it
to
the
closed
garage
door
position
and
hold
again
f or
2
seconds.
For
the
hardwire
loop,
open
contact
f or
2
seconds
and
close
the
contact.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
(Terminals)
or
3
(Tilt)
l
Device
type
=
Garage
Door
or
Door
l
Response
type
=
Garage,
Perimeter
or
Entry
Exit
5853
Sensor
Type:
Glass
Break
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Glass
Break
l
Response
type
=
Perimeter
5869
Sensor
Type:
Wireless
Hold-
Up
Switch
Enrollment
Process:
Enroll
by
sliding
red
switch
to
engage,
use
key
to
release
lock
af ter
2
seconds.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Police
l
Response
type
=
24hr
Audible
or
Silent 5898
Sensor
Type:
DUAL
TEC
Motion
Sensor
l
Loop
1
=
Low
Sensitivity
(Pulse
count
2),
50lb.
or
100
lb.
Animal
Immunity
selectable
via
dip
1
l
Loop
2
=
High
Sensitivity
(Pulse
count
1)
l
Loop
3
=
Temperature
Alarm
(HIGH
or
LOW
via
dip
2)
Enrollment
Process:
Remove
all
the
batteries
and
reinstall
to
enter
the
test
mode
f or
10
minutes.
Reassemble
the
device.
Wait
f or
the
LED
to
f licker
and
turn
yellow.
Trigger
the
motion
sensor
f or
2
seconds
and
stop
motion
to
allow
it
to
restore.
Press
Add
Loop/ Sensor
to
use
multiple
zones.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Motion
Sensor,
Temperature
l
Response
type
=
Interior
Follower.
Auxiliary
5800PIR-
OD
Sensor
Type:
Wireless
Outdoor
Motion
Sensor
Enrollment
Process:
Set
DIP
switch
1
to
ON
to
enter
Walk
test
mode.
Reassemble
the
device.
Trigger
the
motion
sensor
f or
2
seconds
and
stop
motion
to
allow
it
to
restore.
Set
DIP
switch
1
to
OFF
f or
normal
operation.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Motion
Sensor
l
Response
type
=
Perimeter
5800PIR-
RES
Sensor
Type:
Wireless
Motion
Detector
-
Residential
Enrollment
Process:
Remove
the
battery
and
reinstall
to
enter
the
test
mode
f or
10
minutes.
Reassemble
the
device.
Trigger
the
motion
sensor
f or
2
seconds
and
stop
motion
to
allow
it
to
restore.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Motion
Sensor
l
Response
type
=
Interior
Follower
5800PIR-
COM
Sensor
Type:
Passive
Inf rared
Motion
Sensor
–
Commercial
l
Loop
1
=
Low
Sensitivity
(Pulse
count
2)
l
Loop
2
=
High
Sensitivity
(Pulse
count
1)
l
Loop
3
=
Temperature
Alarm
Enrollment
Process:
Remove
the
battery
and
reinstall
to
enter
the
test
mode
f or
10
minutes.
Reassemble
the
device.
Trigger
the
motion
sensor
f or
2
seconds
and
stop
motion
to
allow
it
to
restore.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1,
2
or
3
l
Device
type
=
Motion
Sensor,
Temperature
l
Response
type
=
Interior
Follower,
Auxiliary
DSC
Devices
WS4945
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
When
using
the
magnet,
open
contact
f or
2
seconds
and
close.
When
using
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
EV-
DW4917
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
WS4985
Sensor
Type:
Wireless
Flood
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Flood
l
Response
type
=
24
Hour
Auxiliary
or
Monitor
WLS914
Sensor
Type:
Wireless
Pet-
Immune
Passive
Inf rared
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Motion
Sensor
l
Response
type
=
Interior
Follower
EV-
DW4975
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
Repeat
f or
a
total
of
3
times.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
WLS922L
Sensor
Type:
Wireless
Glassbreak
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Glass
Break
l
Response
type
=
Perimeter WS4904
Sensor
Type:
Wireless
Passive
inf rared
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Motion
Sensor
l
Response
type
=
Interior
Follower
DW4927SS
Sensor
Type:
Wireless
Shock
Sensor
with
Built-
In
Door/ Window
Contact
Enrollment
Process:
Shock
the
sensor
and
allow
it
to
restore
a
total
of
3
times.
Note:
The
door/ window
contact
trips
the
same
zone
as
shock
and
is
not
separately
learned.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
2GIG
Devices
2GIG-
DW20R-
345
Sensor
Type:
Recessed
Door/ Window
Contact
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
(Terminals)
or
2
(Reed)
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
2GIG-
DW10-
345
Sensor
Type:
Thin
Door/ Window
Contact
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
For
the
hardwire
loop,
open
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
(Terminals)
or
2
(Reed)
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
2GIG-
TILT1-
345
Sensor
Type:
Tilt
Sensor
Enrollment
Process:
Remove
the
sensor
f rom
the
garage
door
to
enroll.
For
the
tilt
loop,
f ault
it
by
rotating
the
device
simulate
garage
door
movement
to
the
open
position,
holding
it
f or
2
seconds.
Restore
it
by
returning
it
to
the
closed
garage
door
position
and
hold
again
f or
2
seconds.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Garage
Door
l
Response
type
=
Garage 2GIG-
FT1-
345
Sensor
Type:
Flood
and
Temperature
Sensor
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
Note:
Do
no
enroll
more
than
1
loop.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Flood
or
Temperature
l
Response
type
=
Monitor
or
Auxiliary
2GIG-
GB1-
345
Sensor
Type:
Wireless
Glass
Break
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Glass
Break
l
Response
type
=
Perimeter
2GIG-
PIR1-
345
Sensor
Type:
Passive
Inf rared
Motion
Detector
Enrollment
Process:
Enroll
by
f aulting
and
restoring
the
tamper.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Motion
Sensor
l
Response
type
=
Interior
Follower
ITI
(Quolsys)
TX-
E201
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
TX-
E221
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
TX-
E401
Sensor
Type:
Tilt
Sensor
Enrollment
Process:
For
the
tilt
loop,
f ault
it
by
rotating
the
device
simulate
garage
door
movement
to
the
open
position,
holding
it
f or
2
seconds.
Restore
it
by
returning
it
to
the
closed
garage
door
position
and
hold
again
f or
2
seconds.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Garage
Door
l
Response
type
=
Garage TX-
E611
Sensor
Type:
Flood/ Freeze
Sensor
Enrollment
Process:
Sensor
has
separate
serial
numbers
f or
f lood
low
temp.
To
learn
as
a
f lood
sensor,
tap
a
magnet
to
the
sensor
at
the
point
indicated
by
the
line.
Repeat
as
required.
Save
as
loop
1.
To
learn
the
f reeze
sensor,
tap
and
hold
a
magnet
at
the
point
indicated
by
the
line
f or
two
seconds.
Repeat
as
required.
Save
as
loop
1.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Flood
or
Temp
l
Response
type
=
Monitor
or
Auxiliary
Bosch
Devices
60-
362N-
10-
319.5
Sensor
Type:
Door/ Window
Sensor
Enrollment
Process:
For
the
hardwire
loop,
open
contact
f or
2
seconds
and
close.
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
Radion
RFDW-
SM-
A
Sensor
Type:
Surf ace
Mount
Door/ Window
Sensor
Enrollment
Process:
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
Radion
RFUN-
A
Sensor
Type:
Radion
Universal
Transmitter
Enrollment
Process:
For
the
supervised
hardwire
loop,
short
the
contact
f or
2
seconds
and
restore
the
2.2kohm
resistance
f or
2
seconds.
For
the
reed
loop,
open
the
magnetic
contact
f or
2
seconds
and
close.
In
AN360
or
Local
Programming
enter:
l
Loop
number
=
1
l
Device
type
=
Door
or
Window
l
Response
type
=
Perimeter
or
Entry
Exit
www.resideo.com
Resideo
Technologies,
Inc
2
Corporate
Center
Drive,
Suite
100
P.O.
Box
9040,
Melville,
NY
11747
©
2024
Resideo
Technologies,
Inc.
All
rights
reserved.
R800-
28760A-
MC