First Alert VISTAHRELAY - Data Sheet - Dated 11/24
Related Products
Document Transcript
The VISTAHRELAY module allows up to four hardwired, form-C
(SPDT) relay outputs per module to be added to the VISTAH
series control panels. It is mounted remotely and wired to the
control panels iBus wiring terminals for power.
The module has a built-in tamper allowing detection and
reporting if the front cover is removed and is supervised so if
the wiring is cut a supervision alarm will result indicating the
module may not be operational. The flexibility to mount the
module on a surface wall or to a gang box depending on the
installation environment and the terminal strips are removeable
to give installers easier access to help making wiring easier.
Specifications
•
Supports normally open, normally closed, common,
double balanced, zone doubling and End of line
resistors types
•
Physical Dimensions
: 6.93”W X 5.43” H X 1.99 D or
176mm W X 138mm L X 50.5mm D
•
Electrical Input Voltage
: 12VDC nominal (10-14VDC)
•
Electrical Input Current
: 25mA standby + 20Ma per
active relay
•
Contact Rating
: 3A max at 30VDC & #A max at
120/240VAC (Resistance Load)
•
Power supply regulation on board – powered off the
VISTAH3 controls power and battery backed up if
panel losses AC.
•
Loop Response Time = 400ms
•
Required Loop Resistance = 2.2K ohm
•
Operating Temperature
: 32 to 122 F, 0 to 50 C
•
Operating Humidity
: 0-95% Max (Relative Humidity)
•
NFPA-72 Compliant
VISTAHRELAY
VISTA
®
H3 Hybrid Series
Hardwired Relay Module For more information
resideo.com/pro
VISTAHRELAY_DS | CP | 11/24
© 2024 Resideo Technologies, Inc.
All rights reserved
Resideo Technologies, Inc.
2 Corporate Center Dr. Suite 100
P.O. Box 9040 Melville, NY 11747
1-800-645-7492
12
34
VIST
AHRELA
Y-003-V0
1B
1A
2B
2C
1C
3C
4C
2A
3B
3A
4B
4A
VIST
AHREL
AY
Relay Module
5C
5D
7
5B
5A
6
Ordering Information
Part #
VISTAHRELAY
iBus Wiring Limitations
Wire Gauge
Total Current of All Devices Connected to a Single Wire Run
(AWG)
50mA or less
100mA
300mA
500mA
600mA
#22
700ft (213m)
350ft (107m)
120ft (37m)
70ft (21m)
60ft (19m)
#20
1200ft (366m)
600ft (183m)
200ft (61m)
120ft (37m)
100ft (30m)
#18
1900ft (579m)
950ft (290m)
320ft (98m)
190ft (58m)
160ft (49m)
#16
3000ft (914m)
1500ft (457m)
500ft (152m)
300ft (91m)
260ft (76m)
Note:
The length of all wire runs for all partitions combined must not exceed 3000 feet (914m) when unshielded quad conductor cable is used
or 1500 feet (457m) if shielded cable is used.
SUMMARY OF CONNECTIONS
Relay 1
1A
Normally Open
1B
Common
1C
Normally Closed
Relay 3
3A
Normally Open
3B
Common
3C
Normally Closed
iBus
5A
Green: iBus A
5B
Yellow: iBus B
5C
Black: Negative (-)
5D
Red: Positive (+)
6
LED
7
Tamper
Relay 2
2A
Normally Open
2B
Common
2C
Normally Closed
Relay 4
4A
Normally Open
4B
Common
4C
Normally Closed
- Uploaded