Document Transcript

Step
-
by
-
Step


Updated by Honeywell Tech Support:
6/10/2014

-

1

-



4232CBM Setup for

15P/20P
/21iP

Family Panels



Step #1.

Confirm Panel Compatibility
-

Confirm
panel supports this module by checking the Revision.


Supported panels:

VISTA
-
15P,
VISTA
-
15PSIA, VISTA
-
20P, VISTA
-
20PSIA and First Alert Professional equivalents (firmware level 9.1 or
higher)

VI
STA
-
21iP, VISTA
-
21iPSIA

(firmware level 3.13 or higher)



Step #
2
.

Panel Programming


a.

Enable RIS in location *91 by entering a 2
in
the second
entry

(2 or 3 on SIA panels)
.

The panel can only
support 1 RIS device, so the 4232CBM cannot be used with Total

Connect 2.0

Note:
4232CBM is fixe
d at address 25 on these panels


b.

Enable
virtual
keypad
address
used

(This address is selected in the Home
Control software
)
. AUI keypad in
*189
(
or
standard keypad in *190
-
*196)


NOTE:
When using the 4232CBM, the selected keypad device address serv
es as a
virtual device used for automation
.
Therefore,
the selected ad
dress cannot be used
for an actual
keypad address
.



Step #3.
Control Panel
Wiring



a.

Locate the 4
-
wire ECP harness that came with the 4232CBM. Wire the harness to the Keypad bus of panel
and plug the harness into connector on the 4232CBM. (Do not lose this

connector as it is not a separately
orderable part)











ECP Connection: 900 ft max home

run with 22 AWG unshielded wire







Step
-
by
-
Step


Updated by Honeywell Tech Support:
6/10/2014

-

2

-




Step #
4
.
Automation
Wiring


a.

For Control
-
4,
Key Digital, and
Lutron Radio RA2 systems w
ire the
9pin
RS232 Cable to the
4232CBM
RS2
32 GND, RX and TX terminals as shown
.



















b.

For Savant systems wire the RJ45 cable to the 4232CBM RS232 GND, RX and TX terminals as shown.







c.

For URC systems wire the 3.5mm TRRS connector to the 4232CBM RS232 GND, RX and TX
terminals as
shown.