ADEMCO 5814
DOOR/WINDOW TRANSMITTER
BATTERY (+SIDE UP)
PC BOARD
COVER PRY OFF POINT
«
1/2” MAX SPACING
INSTALLATION INSTRUCTIONS
Use the 5814 Door/Window Transmitter only with alarm systems that support 5800 series wireless devices. The transmitter has its own unique serial number permanently assigned during manufacture, which must be entered into the control panel prior to the transmitterÕs usage. Refer to the control unit's installation instructions for programming details. Note: During programming of the control unit, 5814 transmitters should be treated as "RF" (i.e. supervised RF) Type (mandatory for UL installations ). The 5814 is assigned one zone.
5814 WITH BACK COVER OFF
REED SWITCH ON UNDERSIDE OF PC BOARD (IN UNIT)
MAGNET
q SYMBOL ON SIDE OF FOR MAGNET CASE SHOWS
LOCATION OF REED SWITCH
GUIDE MARK
FCC STATEMENT FCC ID: ÊCFS8DL5814
This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions:ÊÊ(1) This device may not cause harmful interference, and (2) must accept any interference received, including interference that may cause undesired operation.
MOUNTING
The unit is generally mounted as shown in the diagram, with the magnet located to the unit's right. However, it can be installed in any position, as long as the relationship of the unit to the magnet is maintained. Before mounting the transmitter permanently, conduct Go/No Go tests (see control's instructions) to verify adequate signal strength from the mounting location. 1. Mount using double -faced tape (supplied) by affixing it to the back of the unit and mounting the unit in place.
SPECIFICATIONS Unit Dimensions:
1-1/2Ó (37mm) x 1-3/16Ó (30mm) x 5/8Ó (15mm) Battery: Duracell DL2430 or Renata/Sanyo/Varta CR2430
REFER TO THE INSTALLATION INSTRUCTIONS FOR THE RECEIVER/CONTROL WITH WHICH THIS DEVICE IS USED FOR WARRANTY INFORMATION, AND DETAILS REGARDING THE LIMITATIONS OF THE ENTIRE ALARM SYSTEM.
Warning: Do not mount unit in a location where temperature my approach freezing point (32°F).
2. Mount the magnet (supplied) adjacent to the alignment mark on the unitÕs case (see Diagram).