Honeywell 5870API Install Tips
Related Products
Document Transcript
5870API Wireless Indoor Asset Protection Sensor Important Installation Tips
Mount the 5870API on a stable area of the asset that is free from vibration. Try to avoid mounting near speakers, fans or motors. Loop 1 is for high security (fast trigger) applications and should only be used if the asset will not be subjected to external vibration.
LOOP 1
Painting 1-3 Seconds
High Security (Fast Trigger) Mode (Loop 1)
Mount the 5870API on a clean, flat surface.
The 5870API is not intended for use on swinging or sliding doors.
Mount the 5870API on assets that are not intended to move or be tampered with.
The 5870API is mounted directly to the protected asset via 3M VHB double-sided tape. Over time, a strong bond will occur with the tape. Care should be taken on the final location.
Mount the 5870API in an inconspicuous area on the asset away from public view.
The 5870API is intended for indoor use only. It is not watertight and should not be used in damp locations or where temperatures may drop below 14˚ F (-10˚ C).
(See reverse side for additional information.)
5870API Wireless Indoor Asset Protection Sensor
Device Operation
Installer Test Mode Upon initial battery power-up, the unit will transmit each time it is faulted or restored,
which lets you enroll and test the device. After the sensor transmits its first supervisory message (about 70 – 80 minutes after power-up), it switches to normal mode.
Normal Mode In normal mode, there is a three-minute lockout between transmissions to
help conserve battery life. To return to the installer test mode, remove and reinstall the battery.
Modes of Operation
LOOP 1 is for High Security (Fast Trigger) applications and should ONLY be used if the asset will NOT be subject to external vibration. Loop 2 (Standard Security mode) should be used in most cases.
FAULT
LOOP 1
Painting 1-3 Seconds
LOOP 3
30
O
30
O
LOOP 3
NORMAL
OR
High Security (Fast Trigger) Mode (Loop 1)
Jewelry Box
MOUNT HORIZONTALLY ONLY (LOOP 3 ONLY)
LOOP 2
Large Screen TV 5-8 Seconds 30
O
Greater than 30
O
LOOP 3
Standard Security Mode (Loop 2)
Tilt Mode (Loop 3)
Operating Mode
Loop
Faults when…
Restores when…
High Security (Fast Trigger) Mode Short travel time, minimum movement detection Standard Security Mode Long travel time, occasional movement detection Tilt Mode Intended for boxes with lids that can be opened (e.g.; jewelry or cash boxes)
1
Asset/sensor is moved for 1-3 seconds (typical)*
Motion of the asset/sensor has stopped for 3 seconds*
2
Asset/sensor is moved for 5-8 seconds (typical)*
Motion of the asset/sensor has stopped for 3 seconds*
3
Asset/sensor is tilted >30 (+/-10) degrees with respect to the horizon
Asset/sensor is tilted <15 (+/-5) degrees with respect to the horizon
*Response time will be affected by the type of motion (walking, running, dropping, etc.) as well as other tasks being processed by the control panel.