Honeywell 5870API Quick Install Guide
Document Transcript
5870API Wireless Indoor Asset Protection Sensor Quick Intallation Guide
Step 1. Select Location
Paintings
Gun Case/Safe
Large Screen TV Jewelry Box Valuables Computers
Avoid sources of vibration (i.e. speakers, fans, motors) Choose a stable, clean, flat surface Mount in an inconspicuous area
Step 2. Select Operating Mode
LOOP 1 is for High Security (Fast Trigger) applications and should ONLY be used if the asset will NOT be subject to external vibration. Loop 2 (Standard Security mode) should be used in most cases.
FAULT
LOOP 1
Painting 1-3 Seconds
LOOP 3
30
O
30
O
LOOP 3
NORMAL
OR
High Security (Fast Trigger) Mode (Loop 1)
MOUNT HORIZONTALLY ONLY (LOOP 3 ONLY)
Jewelry Box 30
O
LOOP 2
Large Screen TV 5-8 Seconds
Greater than 30
O
LOOP 3
Standard Security Mode (Loop 2)
Tilt Mode (Loop 3)
2. Enter Zone Number, Zone Type and Input Type at keypad
Step 3. Program Device
SENSOR TAB
PULL TO CONNECT BATTERY
Pull tab
Enroll Serial Number (press tamper switch)
1. Pull tab to activate battery
Enter Loop Number at keypad (use Loop 2 unless Fast Trigger or Tilt is required) Peel here (Asset) Mounting Surface
Step 4. Install Device
2. Peel tape backing before installing. Place onto asset.
4. Press down firmly for five seconds.
Step 5. Test System
1. Clean mounting surface 3. Rotate into position
L/5870APIQIGF/D March 2009 © 2009 Honeywell International Inc.
- Uploaded