Honeywell 7847I-L Installation Manual


Yes, you can use a 7847i with a VISTA-128 and you can set it up to be IP primary with phone line back up.
Is it possible to setup a Visa 128 with the 7847i so that it uses the Internet, but in the event of an issue reverts to the hard-wired phone line to send alarm data?

Related Products

Honeywell 7847i-L - AlarmNet L3000 LYNX Plus Internet Alarm Monitoring Communicator
Honeywell 7847i-L
AlarmNet LYNX Plus Internet Alarm Monitoring Communicator
Honeywell 7847i - AlarmNet Internet Alarm Monitoring Communicator
Honeywell 7847i
AlarmNet Internet Alarm Monitoring Communicator
Honeywell L3000PK - LYNX Plus Wireless Security System
Honeywell L3000PK
LYNX Plus Wireless Security System
Honeywell GSMVLP - AlarmNet LYNX Plus Cellular Alarm Monitoring Communicator
Honeywell GSMVLP
AlarmNet LYNX Plus Cellular Alarm Monitoring Communicator
Honeywell L3000 - LYNX Plus Wireless Alarm Control Panel
Honeywell L3000
LYNX Plus Wireless Alarm Control Panel
Honeywell L3000-SIA - LYNX Plus Wireless Alarm Control Panel
Honeywell L3000-SIA
LYNX Plus Wireless Alarm Control Panel
Honeywell K10145WH - LYNX Plus L3000 AC Transformer 9VAC, 25VA
Honeywell K10145WH
L3000 LYNX Plus AC Transformer 9VAC, 25VA
List Price: $24.00
Our Price: $18.99

Related Categories


Document Transcript

Internet Communication Module Installation and Setup Guide

AlarmNet! 7847i-L

K14167V1

10/10

Rev. B

7847i-L Installation and Setup Guide

Table of Contents
GENERAL INFORMATION....................................................................................................... 3 Features .................................................................................................................................... 3 About AlarmNet-i Internet Application ................................................................................. 3 IP Uploading/Downloading Using the 7847i-L ...................................................................... 3 Encryption ................................................................................................................................ 4 7847i-L Module Kit .................................................................................................................. 4 INSTALLING THE 7847i-L MODULE ..................................................................................... 5 Mounting and Connecting the 7847i-L in the LYNX PLUS ................................................. 5 Mounting and Connecting the 7847i-L in the LYNXR-2....................................................... 6 Ethernet Connections .............................................................................................................. 7 Programming the 7847i-L ....................................................................................................... 8 Using AlarmNet Direct Website....................................................................................... 8 Using a 7720P Programming Tool.................................................................................... 9 Programming Conventions ............................................................................................... 9 PROGRAMMING .......................................................................................................................10 Entering Program Mode ........................................................................................................ 10 Exiting Programming Mode .................................................................................................. 14 Setting Factory Defaults .......................................................................................................14 ECP Status Codes .................................................................................................................. 15 REGISTRATION ........................................................................................................................15 Registering the 7847i-L ......................................................................................................... 15 Using the Registration/Test Alarm Button ................................................................... 15 Using the Programming Tool.......................................................................................... 16 Registering through AlarmNet Direct Website ............................................................. 17 Registering by Phone....................................................................................................... 17 PROGRAMMER KEYBOARD COMMANDS ........................................................................18 NETWORK DIAGNOSTICS .....................................................................................................20 Running Network Diagnostics on the 7847i-L using AlarmNet ......................................... 20 APPENDIX A ..............................................................................................................................21 SUMMARY OF LED OPERATION .........................................................................................21 7847i-L Status Display Operation ........................................................................................ 21 Message Status During Normal (Idle) State ........................................................................ 21 GLOSSARY..................................................................................................................................20 SPECIFICATIONS.....................................................................................................................24 WARRANTY INFORMATION ................................................................................................................24 -2-

7847i-L Installation and Setup Guide

GENERAL INFORMATION
AlarmNet’s 7847i-L Internet Communication Module was developed to transport alarm signals from the LYNX PLUS or LYNXR-2 controls to an AlarmNet central station via the Internet. The easy-to-install 7847i-L provides sophisticated data security and communicates with all AlarmNet central stations through AlarmNet’s server. In addition to alarm reporting, the 7847i-L provides upload/download programming capability via the Internet.
The 7847i-L module requires an AlarmNet–i account. For new installations, please obtain the account information from the central station prior to programming this module.

• • • • • • •

Features
Installs inside LYNX PLUS and LYNXR-2 control assembly. Easy CAT-5 10/100 BaseT connection to a hub or router. Operates behind firewalls without compromising network security. Supports dynamic or fixed IP addressing. Simple programming using a 7720P programming tool or via the AlarmNet Direct Website. Reports fire, burg, and status messages via the Internet. Allows uploading and downloading of control panel data over the Internet.

About AlarmNet-i Internet Application
AlarmNet-i is a fully encrypted, secure method of delivering alarm messages from a protected premise to an AlarmNet equipped central station. An Internet Communicator Module transmits status, supervisory, and alarm messages to the AlarmNet Control Center using a broadband Internet connection. The AlarmNet Control Center identifies, validates, and forwards the messages to the appropriate AlarmNet central station. AlarmNet-i has an unlimited account capacity.

IP Uploading/Downloading Using the 7847i-L
The 7847i-L can be used to provide high-speed up/downloading to the LYNX PLUS or LYNXR-2 control. This allows site maintenance independent of central station monitoring, and modification to sites globally via the Internet. Figure 1 shows data flow when the system is set up for use with the Internet.
LYNXR-2/ LYNX PLUS COMPASS

INTERNET

7847i-L ALARMNET ROUTING CENTER

INTERNET FLOW DIAGRAM

7847i-L-004-V1

Figure 1. IP Uploading/Downloading via Internet Flow Diagram -3-

7847i-L Installation and Setup Guide

Encryption
The 7847i-L supports private key encryption. Private key encryption means that both the sender and the receiver know the KEY used to encrypt the data. Each device produced by Honeywell is loaded with a globally unique identifier called a MAC number, and a large random number or KEY. This KEY and MAC number are also stored in the AlarmNet servers. When a device contacts AlarmNet it sends the MAC number in the clear followed by the message that is encrypted using the KEY data. The server looks up its copy of the KEY based on the MAC number and uses that KEY to decrypt the message. The 7847i-L uses 256 bit AES encryption (which is required for certain government installations). The AlarmNet-i AES Encryption Software Module Version 1.0 contained in the Honeywell products has NIST approval. Listings for this approval can be found at http://csrc.nist.govgroups/STM/cavp/documents/aes/aesval.htm Certificate #979.

7847i-L Module Kit
This kit contains the following components:

SCREWS (2)

CABLE P/N 600-00167-1

NYLON TIE WRAP (2) 7847i-L MODULE TIE WRAP MOUNT
7847i-L-027-V0

Figure 2. 7847i-L Kit Components

-4-

7847i-L Installation and Setup Guide

INSTALLING THE 7847i-L MODULE Mounting and Connecting the 7847i-L in the LYNX PLUS
1. Release the control’s front case assembly from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver. 2. Install the control in accordance with the appropriate Installation Instructions. 3. Install the 7847i-L into the control’s back case and secure it with the two provided screws. Refer to Figure 3.
Do not block the ventilation slots in the case when installing the tie wrap mount.

4. Remove the backing from the tape on the provided tie wrap mount. Install the tie wrap mount in the lower right corner of the back case as shown on Figure 3. 5. Connect the provided communications cable (P/N 600-00167-1) between the module and the PC board as shown in Figure 3. This cable provides DC power and ground for the module and data in/out connections. Ensure that the cable is routed through the routing tunnels and/or the strain relief clip as shown in Figure 4.
The communications and battery cables must be routed as shown in Figure 4.
SCREW (2) RJ45 (FOR INTERNET CONNECTION) 7720P PROGRAMMER CONNECTION

CABLE P/N 600-00167-1

TIE WRAP MOUNT

BACK CASE

TAPE

WIRE STRAIN RELIEF CLIP

FRONT CASE

COMMUNICATIONS PORT FOR INTERNAL 7847i-L MODULE ONLY

LOCKING TABS

1000-300-029-V0

Figure 3. 7847i-L Module Installation in the LYNX PLUS -5-

7847i-L Installation and Setup Guide

WIRE ROUTING TUNNELS

TIE-WRAP POINT TIE WRAP

TIE WRAP MOUNT MOUNTING HOOKS

TERMINAL STRIP NOTE ENSURE ALL WIRING IS ROUTED THROUGH WIRE STRAIN RELIEF CLIP WIRE STRAIN RELIEF CLIP LOCAL SOUNDER DISABLE SWITCH

TELEPHONE CONNECTION

BATTERY CABLE

POWERLINE CARRIER DEVICE CONNECTOR
1000-300-006-V2

Figure 4. 7847i-L Module/LYNX PLUS Wire Routing

Mounting and Connecting the 7847i-L in the LYNXR-2
1. Release the control’s front case assembly from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver (refer to Figure 5). 2. Install the control in accordance with the appropriate Installation Instructions. 3. Install the 7847i-L into the control’s back plate and secure it with the two provided screws as shown in Figure 5. 4. Connect the provided communications cable (P/N 600-00167-1) between the module and the PC board as shown in Figure 5. This cable provides DC power and ground for the module and data in/out connections.

-6-

7847i-L Installation and Setup Guide
7720P PROGRAMER CONNECTION RJ45 (FOR INTERNET CONNECTION)

LOCKING TABS

SCREW (2)

COMMUNICATION PORT FOR INTERNAL 7847i-L MODULE ONLY

CABLE P/N 600-00167-1

LOCKING TABS

LOCKING TABS

DISCONNECT THIS END ONLY!

7847i-L-017-V3

Figure 5. 7847i-L Module Installation in the LYNXR-2

Ethernet Connections

UL 2.

1. For UL installations, the Cat. 5 Ethernet connection between the 7847i-L and the router cannot exceed 12 feet with both the 7847i-L and the router located within the same room. Use a Listed cable/DSL router suited for the application.

1. Connect one end of the Ethernet cable (Category 5) to the RJ45 Ethernet connector on the 7847i-L module and the other end to a cable/DSL router (refer to Figure 6). 2. When programming the module, plug the programming cable from the 7720P Programming Tool into the programming connector on the 7847i-L module (refer to Figure 6).

-7-

7847i-L Installation and Setup Guide
Xmit Shift

BS / ESC /

A

1
D

2
E

B

3 6 9 #
X Enter F

C

4
N /Y Shift S

5 8 0
T

7
Space

REGISTRATION/ TEST ALARM BUTTON RJ45 (FOR INTERNET CONNECTION) 7720P PROGRAMMING CONNECTOR

LEDs

GRN YEL RED YEL

ETHERNET CABLE TO ROUTER
7847i-L-002-V3

Figure 6. 7847i-L Ethernet Connection

Programming the 7847i-L
The 7847i-L module requires an AlarmNet–i account. Obtain the account information from the central station prior to programming this module. The control panel treats the 7847i-L Internet Communication Module as a longrange radio device.

The 7847i-L delivers alarms occurring on the LYNX PLUS or LYNXR-2 control to an AlarmNet central station via the Internet. The communication is encrypted to ensure security (refer to the Encryption paragraph for additional information). The 7847i-L can be programmed through the following methods: • The AlarmNet Direct Website • Use of a 7720P Programming Tool Using AlarmNet Direct Website To program the module via the website (if you are already signed up for this service), go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx If you are not signed up for this service, click on “Dealer Sign-Up. Log in and follow the onscreen prompts. Please have the following information available when programming the module: 1. Primary City ID (two-digit number) 2. Primary Central Station ID (two-digit hexadecimal number) 3. Primary Subscriber ID (four-digit number) 4. MAC ID and MAC CRC number (located on the outside of box and on label inside the module).

-8-

7847i-L Installation and Setup Guide After programming is complete, you must transfer the data to the module and the module must be registered. Refer to the Registration paragraph, for further instructions. Using a 7720P Programming Tool Connect the 7720P Programming Tool; refer to Figure 7. The 7847i-L powers the 7720P Programming Tool via the programming jack, and automatically senses the presence of the 7720P when it is plugged in. Each key of the 7720P has two possible functions: a normal function and a Shift function. • To perform a normal key function, simply press the desired key. • To perform a Shift function, press the [Shift] key, and then press the appropriate key. The prompts in this document reflect use of the 7720P Programming Tool. Table 1 below lists each normal and shift key function. Table 1. 7720P Normal and Shift Key (shift LED lit) Functions
KEY BS/ESC ↓/↑ N/Y SHIFT 1/A 2/B 3/C 4/D 5/E 6/F 7/S 8/T 9/X SPACE 0 #/ENTER SHIFT KEY FUNCTION [ESC]: Press to quit program mode; also can reset programming defaults* [↓]: Scroll down programming [↑]: Scroll up programming [N]: Press for "NO" answer [Y]: Press SHIFT-Y for "YES" answer Press before pressing a SHIFT key function. Will light SHIFT LED. LED goes out once a key is pressed. Press again for each SHIFT function desired. [1]: For entering the number 1 [A]: For entering letter A [2]: For entering the number 2 [B]: For entering letter B [3]: For entering the number 3 [C]: For entering letter C [4]: For entering the number 4 [D]: For entering letter D [5]: For entering the number 5 [E]: For entering letter E [6]: For entering the number 6 [F]: For entering letter F [7]: For entering the number 7 [S]: For entering letter S [8]: For entering the number 8 [T]: For entering letter T [9]: For entering the number 9 [X]: For entering letter X [SPACE]: For scrolling option list No SHIFT function [0]: For entering the number 0 No SHIFT function [#/ENTER]: Press to accept entries No SHIFT function NORMAL KEY FUNCTION [BS]: Press to delete entry

* Active only when the "Exit Prog Mode?" prompt is displayed.

Programming Conventions Programming is accomplished by answering a series of prompts (questions). Most prompts require only a [Y]es or [N]o response, while others require a numerical response (ID numbers, etc.). The current value is displayed on the second line in parentheses ( ). A "?" indicates an invalid entry. Use the [Enter] key to accept the current entry and proceed to the next prompt. If the entered value is invalid, pressing [Enter] re-displays the prompt; the next prompt is not displayed until a valid answer is entered. Use the up/down arrow keys to scroll through the programming questions without changing any values. Press the [ESC] key to go to the end of the list of questions. -9-

7847i-L Installation and Setup Guide

PROGRAMMING Entering Program Mode
Press the [Enter] key to begin programming.
NOTE: The central station can remotely block access to local device programming. If this has been done, the following prompt appears:

Access to Prog Mode Denied

Table 2. Programming a 7847i-L
PROMPTS 1 2 Strt Prog Mode? (Y/N)_ Enter Password: ENTRY OPTIONS [Y], [N] [0-9, A-F, N, S, T, X, Y] DESCRIPTION Enters programming mode. If a password has been previously assigned, this prompt appears. Enter a 4-digit password (0-9, A-F, N, S, T, X, Y). The next prompt appears. To begin programming the module, press [Y] and go to Prompt 9: "Device Mode." To create a password if none has been assigned, press [N] and go to Prompt 4: "Create Password." To change an existing password, press [N] and go to Prompt 5: "Change Password." Passwords can be used to protect account and programming information. If no password has been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt. If a password is desired, press [Y] and go to Prompt 6: "Enter Password." If a password has already been assigned, this prompt appears after pressing [N] at the "Program Device?" prompt. Press [Y] if you want to change the password.
NOTE: To clear an existing password, without entering a new one, answer [Y] to the "Change Password?" prompt, then press the [Enter] key when prompted for the new password and its confirmation.

3

Program Device? (Y/N)_

[Y], [N]

4

Create Password? (Y/N)_

[Y], [N]

5

Change Password?
(Y/N)_

[Y], [N]

6

Enter Password

[0-9, A-F, N, S, T, X, Y]

This prompt is displayed if [Y] was pressed in Prompt 4 or 5. Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).

- 10 -

7847i-L Installation and Setup Guide
PROMPTS 7 Verify Password ENTRY OPTIONS [0-9, A-F, N, S, T, X, Y] DESCRIPTION Re-enter the password as confirmation. If the password doesn't match the first entry, the following is displayed followed by the "Exit Prog. Mode?" prompt: Verify Not OK PSWD not created Otherwise, the "Exit Prog. Mode?" prompt is displayed directly. Exits program mode. Press [N] to go back to Prompt 3. Press [ESC] to load factory defaults. Refer to the Exiting Programming Mode paragraph. Press [ENTER] to select ECP mode (LYNX PLUS and LYNXR-2 supports ECP mode only). The 7847i-L uses ECP messaging to communicate with the control panel via the cable connection. To allow central station reporting of alarms via the 7847i-L, make sure the LYNXR-2 or LYNX PLUS field *55 Enable/Disable ECP Interface is enabled. When enabled, the LYNX PLUS or LYNXR-2 sends contact ID format reports to the 7847i-L, which then sends the reports to the central station. Use LYNX PLUS or LYNXR-2 field *77 to assign the reporting priorities between the LYNX PLUS or LYNXR-2 dialer and the 7847iL. Refer to the LYNX PLUS or LYNXR2 Programming Guide for detailed information regarding these fields.

8

Exit Prog. Mode? (Y/N)_

[Y], [N] [ESC]

9

Device Mode (ECP)_

• ECP • 4204 Emu • 2-4204s

Important Information Regarding Primary Accounts (Questions 10-12)

Account information is provided by the central station administrator.
10 11 12 Primary City ID (??)_ Primary CS ID (??) Primary Sub ID (????) [01-99] [01-FE] Enter the 2-digit primary city ID, 01-99 (decimal). Enter the 2-digit primary central station ID number, 01-FE (HEX). Enter the 4-digit subscriber account number, 0001-9999 (decimal).

[0001-9999]

- 11 -

7847i-L Installation and Setup Guide
PROMPTS 13 Device Address (03)_ ENTRY OPTIONS [01-30] DESCRIPTION In ECP mode, the 7847i-L communicates with the panel as a Long Range Radio (LRR) device. Enter address 03 for LYNX PLUS or LYNXR-2 Series controls. NOTE: When programming the control, enable the LRR output. Press [Y] to allow the end user to access [Y], [N] their system via a website. Availability of this service is controlled by the dealer via the web-based programming tool on the AlarmNet Direct website. 24 Hours The AlarmNet network must hear at least one supervisory message from the • 1 Hour module during this supervision period; • US UL Line otherwise, AlarmNet notifies the central (6 Min) station that a communication failure • CN UL Line Lvl has occurred. (If the supervision period 3 (3 Min) is changed after registration, you must • US UL Line re-register the module.) (90 Sec) Press the [space] key to scroll through • CN UL Line Lvl choices. 4 (90 Sec) • CN UL Line Lvl 5 (75 Sec) • None • 30 Day • 10 Minutes Sets how long an undeliverable alarm is • 15 Minutes retried for delivery to the central • 30 Minutes station. If the message is not validated, • 1 Hour it is retried until the old alarm time is reached or the message is validated. • 2 Hours • 4 Hours Press the [space] key to scroll through • 8 Hours choices. • 12 Hours • 24 Hours UL NOTE: Must be 10 minutes [00-99] Enter the time delay (01-99) in minutes before the 7847i-L notifies the control panel that there is loss of contact with the network, or enter "00" if you do not want the 7847i-L to alert the control panel of loss of contact with the network. The 7847i-L will alert the control panel of the loss of contact via a dedicated status message. UL NOTE: Must be two (02) minutes.

14

Remote Access Y/N (N)_

15

Supervision (24 Hours)_

16

Old Alarm Time (10 Minutes)_

17

IP Flt Time (60 mins)_

- 12 -

7847i-L Installation and Setup Guide
PROMPTS 18 Use DHCP Y/N (Y)_ ENTRY OPTIONS [Y], [N] DESCRIPTION Dynamically allocates the IP addresses (recommended); then skip to Prompt 24: "Review?" If [N], uses fixed IP addresses. Enter the 4-part address for this device. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode). Enter the 32-bit address mask used to indicate the portion (bits) of the IP address that is being used for the subnet address. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode). Enter the 4-part address assigned to the Gateway. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode). Enter the 4-part IP address assigned to the DNS (Domain Name System) server. The 4 parts of the address must be separated by spaces (displayed as periods in Review mode). For 24 hour UL Battery Backup requirement, this feature must be enabled, or the unit must be powered by an appropriate UL listed UPS. If connectivity problems occur with certain routers or switches disable this option.

19

NIC IP Address: 255.255.255.255_

12 digit: xxx.xxx.xxx.xxx

20

Subnet Mask: 255.255.255.255_

12 digit: xxx.xxx.xxx.xxx

21

Gateway IP Addr: 255.255.255.255_

12 digit: xxx.xxx.xxx.xxx [0.0.0.0.] = not used 12 digit: xxx.xxx.xxx.xxx [0.0.0.0.] = not used [Y], [N]

22

DNS Serv IP Addr: 255.255.255.255_

23

Enable Pwr Save (Y)_

- 13 -

7847i-L Installation and Setup Guide
PROMPTS 24 Review? Y/N ENTRY OPTIONS [Y] = review [N] = exit DESCRIPTION Reviewing Programming Mode Entries To review the programming options (to ensure that the correct entries have been made), press [Y]. The programming prompts are displayed again. Use the up/down arrow keys to scroll through the program fields without changing any of the values. If a value requires change, simply type in the correct value. When the last field is displayed, the “REVIEW?” prompt again appears. To exit the programming mode, press [N] in response to the "REVIEW?" prompt, and refer to Exiting Programming Mode at the end of this section.

Exiting Programming Mode
To exit the programming mode, press [N] in response to the “REVIEW?” question. Then press [Y] to the "Exit Prog Mode?" question. Upon exiting, the root file is updated to log the changes made. A message is displayed telling the user that this step is being executed. When complete, the message “DONE” is displayed to indicate the file was successfully uploaded.
If critical configuration changes were made, the 7847i-L will reset to ensure that the programmed features are enabled.

Setting Factory Defaults
To reset the programming options to factory-default values, press [ESC] at the "Exit Prog Mode?" prompt.
Set Default? Y/N_ Press [Y] to reset factory default values. Press [N] to cancel this function.

If you press [Y], all programmed values are reset to the original factory settings. PLEASE NOTE THAT THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED. After pressing [Y], the Create Password prompt appears (see Prompt 4).

- 14 -

7847i-L Installation and Setup Guide

ECP Status Codes
Table 3 lists the message displayed on the LYNX PLUS and LYNXR-2 display. Table 4 lists the messages sent to the central station. Table 3. ECP Keypad Display Status Code STATUS CODE 103 Fault DESCRIPTION indicates an ECP communications/supervision failure Table 4. ECP Contact ID (685 Displays) Codes CODE* E339 C803 E355 C000 R355 C000 DESCRIPTION ECP power-on reset (occurs upon registration, exiting program mode, or power on reset) 7847i-L lost communication with control panel 7847i-L restore communication with control panel

∗As displayed on 685 Digital Receiver

REGISTRATION Registering the 7847i-L
Once you have initialized and programmed the 7847i-L, it must be registered to enable the account. An unregistered 7847i-L is indicated by the Status (green) LED lit, the Message (yellow) LED slow blinking, and the Fault (red) LED not lit. The Internet Link (yellow) LED may be lit or blinking. Refer to Summary of LED Operation paragraph for a detailed discussion of LED operation. You can register the 7847i-L by one of the following methods: • Through use of the Registration/Test Alarm Button • Through use of a 7720P Programming Tool • Through the AlarmNet Direct website • By phone Upon completion of the registration process, a 7847i-L transmits a registration message and receives a registration validation indicating that the account is now enabled. Using the Registration/Test Alarm Button Initiate the registration sequence by clicking the Registration/Test Alarm Button three (3) times (refer to Figure 7).
REGISTRATION/ TEST ALARM BUTTON
GRN YEL RED

YEL

Figure 7. 7847i-L Registration/Test Alarm Button Location

- 15 -

7847i-L-001-V0

7847i-L Installation and Setup Guide Once the registration has been completed successfully, the 7847i-L enters normal operating mode; the Status (green) LED goes out and the Message (yellow) LED is lit to indicate that the Power On / Reset message is waiting to be sent. This message will appear at the receiving station as “E339 C803” (“03” represents the module’s fixed device address). The description may read “Trouble – Exp. Mod. Reset”. If registration is not validated within 90 seconds, the 7847i-L times out, and the (green) LED will be lit (solid). If repeated registration attempts time out, check your Internet connection and verify that 7847i-L account information has been entered correctly. Using the Programming Tool The interactive registration feature allows the installer to register the 7847i-L through a series of keyboard commands on the 7720P Programming Tool. This method of registration lets the installer monitor the registration process.
Registering …

Once the installation is complete, press the [Shift] and the up arrow [↑] key on the 7720P. The registration message is sent and the unit waits for the acknowledgment. If this is a new installation and the city, central station, and customer numbers have been correctly entered, the 7847i-L is registered and this message is displayed. The 7847i-L is now in full service and available for alarm reporting to the central station.

Registration SUCCESS

Possible Errors When Configured for AlarmNet-i Displayed if no response to the registration request is received. Registration BAD
Timed Out Registration BAD Pri Sub ID BAD

Indicates the city, central station, or customer number for the Primary account is not accepted. The ID information was either entered incorrectly, or the central station failed to pre-authorize programmed ID numbers with AlarmNet customer service. Displayed if this is a repair/replacement, or an error was made in programming the Primary account information of 7847i-L for an existing account. This prompt appears for 2 seconds. This prompt appears after pressing the down arrow [↓] on the 7720P.
NOTE: If you do not have a PIN, you may exit registration mode by pressing [ESC]. Once you have your PIN, you can resume the registration process by pressing [Shift] and the up arrow [↑] key.

Registration BAD Pri ID – Need PIN Enter PIN#

Registering …

Enter a 4-digit alphanumeric PIN number provided by an authorized AlarmNet representative. Press the [Enter] key. The registration message is sent and the unit waits for acknowledgement.

- 16 -

7847i-L Installation and Setup Guide
Registration SUCCESS Registration BAD Pri ID – Need PIN

If the PIN is valid, the new 7847i-L is registered and the old unit unregistered. Additionally, AlarmNet sends a substitution alarm to the central station. If you entered an invalid PIN, the appropriate message is displayed depending on which account number is being replaced (see above for exact wording). The registration process is repeated.
NOTE: Each attempt causes a substitution alarm to be sent to the central station.

Registering through AlarmNet Direct Website Once the module has been programmed, you may register it via the AlarmNet Direct Website. To do this, please go to: https://services.alarmnet.com/AlarmNetDirect/userlogin.aspx. Log in and follow the on-screen prompts. Please have the following information available when programming the device: 1. Primary City ID (two-digit number) 2. Primary Central Station ID (two-digit hexadecimal number) 3. Primary Subscriber ID (four-digit number) 4. MAC ID and MAC CRC number (located on outside of box and on label inside module) 5. Once module is registered, you may log out of the AlarmNet Direct website. Registering by Phone You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at 1-800-222-6525. You will need the following information: • MAC number (found on the label). • Subscriber information (provided by the central station), including a city code, CSID, and a subscriber ID. • When instructed to do so, triple-click the Registration/Test Alarm Button to complete the registration.

- 17 -

7847i-L Installation and Setup Guide

PROGRAMMER KEYBOARD COMMANDS
Programmer keyboard commands can be used to quickly view your Internet connectivity settings and options. Most commands require you to press the [Shift] key and then the designated command key. (See the keys designated in red on the 7720P Programming Tool.)
[A] 7847i-L x.x.xx mm/dd/yy Software Revision "x.x.xx" indicates the installed software Revision. mm/dd/yy indicates month, day and year of the revision. MAC Address “xxxxxxxxxxxx” indicates the 7847i-L’s unique identification number. "yyyy" indicates the MAC CRC number. This number is also found on the label on the module, as well as the label on the box. Press the [Space] key to go to the next field. Press the backspace [BS] key to go to the previous field. Time Retrieves the current date and time from the AlarmNet network in Greenwich Mean Time (GMT). This display confirms that the module is in sync with network. Network Diagnostics Display Indicates whether the device has detected a physical connection to the Internet. Press the [Space] key to go to the next field. IP Information Display Displays the IP address assigned to this device. Press the [Space] key to go to the next field. Displays the 32-bit address mask used to indicate the portion (bits) of the IP Address that is being used for the subnet address. Press the [Space] key to go to the next field. Press the backspace [BS] key to go to the previous field. Displays the IP Address assigned to the Gateway. Press the [Space] key to go to the next field. Press the backspace [BS] key to go to the previous field. Displays the IP Address assigned to the DNS (Domain Name System) server. Press the [Space] key to go to the NIC IP address. Press the backspace [BS] key to go to the previous field. Performs a self-test of the AES encryption algorithm. Press the [Space] key to go to the Physical Link field. Press the backspace [BS] key to go to the previous field. DHCP (Dynamic Host Configuration Protocol) indicates server is performing satisfactorily.

[B]

MAC xxxxxxxxxxxx MAC CRC yyyy

[C]

Mon 01 Jan 2001 05:48:39 am

[D]

Physical Link Good/Bad

NIC IP Address xxx.xxx.xxx.xxx Subnet Mask xxx.xxx.xxx.xxx

Gateway IP Addr xxx.xxx.xxx.xxx DNS Serv IP Addr: xxx.xxx.xxx.xxx

Encryption Test: AES Passed! DHCP: OK

- 18 -

7847i-L Installation and Setup Guide
[F] Testing Gateway Redir 1 Run Network Diagnostic Status (Configured for AlarmNet Reporting) Performs a set of network diagnostics that tests the integrity of the links between the 7847i-L and the various connection points (Redirs) to AlarmNet. Refer to Network Diagnostics paragraph. Status Display Displays the zone and network connectivity status (flt). “i” = Loss of network connectivity but the fault time has not yet expired. “I” = Loss of network connectivity and the fault time has expired. Test Alarm Sends a Test alarm to AlarmNet. Functional for a registered 7847i-L only. If the device is not registered, a message is displayed indicating that the command cannot be executed. Reset the 7847i-L. Pressing [N] returns to normal mode (blank screen = enter next command or escape). Pressing [Y] resets the module (blank screen = reset complete). Registration Registers a programmed 7847i-L with AlarmNet. Refer to Registration paragraph. Registration with PIN for Replacement Module Registers a replacement 7847i-L with AlarmNet, once programmed, using the existing PIN #. Refer to the Registration paragraph. Enter Program Mode Press [Y] to enter program mode; otherwise, press [N].

[S]

ECP

Flt OK

[T]

Test Msg Sent

[X]

Reset CPU Y/N

[↑] ↑ UP arrow [↓] ↓ DN arrow

Registering …

Enter PIN#

[ENTER]

Strt Prog Mode? Y/N_

- 19 -

7847i-L Installation and Setup Guide

NETWORK DIAGNOSTICS Running Network Diagnostics on the 7847i-L using AlarmNet
The network diagnostic process tests the integrity of the links between the 7847i-L and the various connection points of AlarmNet Control that are known as “Redirects” (Redirs or RDR). To initiate the network diagnostics, press the [F] key on the 7720P. NOTE: The test is performed ONLY if a physical link is detected. If no physical link is detected, the test is aborted and the following is displayed: NO PHYSICAL LINK If a physical link is detected, the diagnostics are performed. progression of the test: Testing Redir 1 Testing Redir 1 Reached Gateway Redir 1 Service OK Testing Redir 2 Redir 2 Service OK Testing Redir 3 Redir 3 Service OK RDR1 RDR2 RDR3 OK OK OK The following shows the

The first step of the test traces the connection to Redir 1 at AlarmNet Control. A successful trace to Redir 1 is indicated here. The service at AlarmNet Control on Redir 1 is functioning. If not, “Redir 1 Failed” is displayed. The first step of the test traces the connection to Redir 2 at AlarmNet Control. The service at AlarmNet Control on Redir 2 is functioning. If not, “Redir 2 Failed” is displayed. The first step of the test traces the connection to Redir 3 at AlarmNet Control. The service at AlarmNet Control on Redir 3 is functioning. If not, “Redir 3 Failed” is displayed. A summary of the tests is displayed after Redir 3 is tested. The example shows that the tests of all three connection points, or Redirs, were successful. If an error occurred at any point, the summary will display “FAIL” under the faulty Redir.

- 20 -

7847i-L Installation and Setup Guide

APPENDIX A SUMMARY OF LED OPERATION 7847i-L Status Display Operation
The 7847i-L has four LEDs used to indicate message and device status, and one LED to indicate network connection. When installed in the control, the LEDs appear in the following order from right to left in the LYNX PLUS or from top to bottom in the LYNXR-2. • STATUS, green • MESSAGE, yellow • FAULT, red • LINK, yellow Each LED can have four different states - ON, OFF, FAST BLINK and SLOW BLINK. Throughout this document, the key shown in Figure 8 is used to describe LED state:

OFF

FAST BLINK

SLOW BLINK
7847i-L-024-V0

Figure 8. LED Key Table 5. LED Functions
LED COLOR GREEN LED FUNCTION STATUS DESCRIPTION ON – 7847i-L is NOT registered with AlarmNet. OFF – 7847i-L is registered with AlarmNet FAST BLINK – Download session with Compass in progress. SLOW BLINK – In unison with yellow LED – Registration in progress. ON – Message transmission pending. QUICK PERIODIC BLINK – Normal. FAST BLINK – Message waiting for network ACK. SLOW BLINK – In unison with green LED – registration in progress. ON – No contact with the network. OFF– Normal. SLOW BLINK – Loss of communication with the panel (ECP fault). FAST BLINK – No network contact AND loss of communication with the panel. ON – Ethernet link detected. OFF – No Ethernet link detected. FAST BLINK – Transmitting/Receiving data.

YELLOW

MESSAGE

RED

FAULT

YELLOW ETHERNET LINK/ ACTIVITY

Message Status During Normal (Idle) State
During Normal Operation, the yellow Message LED functions as the 7847i-L’s heartbeat. With no message pending, the heartbeat is an indication that the unit is functioning. The yellow Internet Link LED may be lit solidly or periodically blink during normal operation.

- 21 -

7847i-L Installation and Setup Guide

A
STATUS, GREEN MESSAGE, YELLOW FAULT, RED STATUS, GREEN MESSAGE, YELLOW FAULT, RED

B

7847i-L-025-V0

Figure 9. A Registered 7847i-L Status Display (left) and an Unregistered 7847i-L Status Display (right) in Normal Operating State The sequence below illustrates LED operation when the 7847i-L transmits a message.
1 STATUS, GREEN MESSAGE, YELLOW FAULT, RED
7847i-L-026-V0

2

3

4

Figure 10. LED Sequence for a Registered 7847i-L Message Transmission

- 22 -

7847i-L Installation and Setup Guide

GLOSSARY
AES – Advanced Encryption Standard DHCP – Dynamic Host Configuration Protocol, which provides a mechanism for allocating IP addresses dynamically so that addresses can be reused when hosts no longer need them. DNS – Domain Name System, which is a distributed hierarchical naming system used to resolve domain names (e.g., www.yahoo.com) into numerical IP addresses (e.g., 204.17.25.1.). DSL – Digital Subscriber Line ECP – Enhanced Console Protocol, which is a proprietary communications bus used in Honeywell VISTA control panels for wiring additional keypads and peripheral devices; consists of a four-wire data bus (power +/–, data in/out). Gateway IP Address – A gateway (sometimes called a router) is a computer and/or software used to connect two or more networks (including incompatible networks) and translates information from one network to the other. The Gateway IP address is the IP address for the gateway. IP – Internet Protocol (packet-based protocol) IP Address – A unique number consisting of four parts separated by periods, sometimes called a "dotted quad.," for example: 204.17.29.11, assigned to every computer/workstation connected to the Internet. IP numbers can be "static" (assigned and unchanging) or "dynamic," assigned via DHCP at each and every startup. ISP – Internet Service Provider MAC Address – The hardware address of a device connected to a network. Subnet Mask – A Subnet is a portion of a network that shares a network address with other portions of the network, and is distinguished by a subnet number. The Subnet Mask is a 32bit address mask used in IP to indicate the bits of an IP address that are being used for the subnet address. TCP/IP – Transmission Control Protocol / Internet Protocol

- 23 -

7847i-L Installation and Setup Guide

SPECIFICATIONS
1. Mechanical Dimensions: 2.25" x 2.125" 2. Electrical Input Power: 12VDC (nominal), 14VDC (max) Current Drain: 56mA Shutdown Voltage: 5.5 VDC