Honeywell AlarmNet LTE Communicators - Data Sheet
Related Products
Related Categories
Document Transcript
One-Stop
Support
Sensors
Control
Panels
Communications
AlarmNet
360
™
To t al
Connect
®
DEALERS
Honeywell End-to-End Solution
A
W
A
R
D
-
W
I
N
N
I
N
G
S
O
L
U
T
I
O
N
S
E
V
E
R
-
G
R
O
W
I
N
G
E
C
O
S
Y
S
T
E
M
G
L
O
B
A
L
D
I
S
T
R
I
B
U
T
I
O
N
W
O
R
L
D
-
C
L
A
S
S
C
L
O
U
D
S
E
R
V
I
C
E
S
I
N
D
U
S
T
R
Y
L
E
A
D
I
N
G
S
U
P
P
O
R
T
•
•
•
•
•
LTE
4 G LT E
Cellular Communicators
Honeywell is focused on providing the best alarm
communication solutions for the security industry. Alternative
communication methods are critical in the marketplace due
to VoIP, migration from POTS and the evolution of cellular
networks. LTE network connectivity provides the longest
viable cellular lifespan available.
All signals are delivered to Honeywell’s AlarmNet® Network
Control Center, which routes the information to the
appropriate central station. The state-of-the-art AlarmNet
Network Control Center is fully redundant and monitored
24/7. AlarmNet has the ability to route messages using
AlarmNet-i and 800 PLUS services, providing true redundancy
and multi-path message delivery.
FE AT URES
• 4G LTE network
compatibility
• Full Contact ID
Contact ID reporting using
ECP mode with compatible
Honeywell control panels.
• 256-bit AES Encryption
Advanced encryption
standard used for secure
communications.
• Upload/Download
Available with select
Honeywell control panels.
Requires Compass version
1.5.8.54a or higher.
• Integration
Quick and easy installation
of cellular communicator for
VISTA® and LYNX controls.
• Diagnostic LEDs
Provide signal strength
and status indications.
• QOS
Quality of Service diagnostics
via AlarmNet supply vital
information including when
a message was received,
battery voltage, input
voltage, signal strength
and message path.
• AlarmNet360™ Online
Management Platform
AlarmNet360 Account
Management
https://services.alarmnet.
com/AlarmNet360 —
Remote programming
and diagnostics to improve
business efficiencies
and reduce truck rolls.
• Remote Services Capability*
Optional Honeywell Total
Connect Remote Services —
Boost RMR while providing
on-the-go security and home
control, video viewing, and
real-time alerts, anytime,
anywhere, on any PC or
smart device.
• Two-way Voice Transport
Capable of allowing two-way
voice session in conjunction
with VoLTE (LYNX and
LYRIC models only) an audio
verification system (U.S. and
Canada only).
• FOTA Firmware Upgrading
Complete over-the-air
firmware upgrading
capability. Provides remote
service management ability.
*Service subscription required.
Alarm Communications SPECIFICATIONS
VISTA 4G LTE
Communicators
(LT E-X V/ LT E-X A )
LYRIC 4G LTE
Communicators
( LY R IC LT E- A )
DESCRIPTION
• Integrated VISTA ECP design
• Four-wire connection
• Powered by VISTA
• LTE CAT 1
PANEL COMPATIBILITY
All VISTA controls with ECP radio support
DIMENSIONS
8.4" x 8.0" x 1.5"
(21.3cm x 20.3cm x 3.8cm)
ELECTRICAL
Input Power:
powered from 12V aux power
Current Drain:
210mV
RF
Antenna:
Internal Penta-Band antenna with
receive diversity for LTE CAT1. Average 3.8dBi gain.
ENVIRONMENTAL
Operating Temperature:
-4° to 131° F (-20° to 55° C)
Storage Temperature:
-40° to 158° F (-40° to 70° C)
AGENCY LISTINGS
ETL Listed
DESCRIPTION
LTE CAT3 cellular module
PANEL COMPATIBILITY
LYRIC Controller firmware version 1.03 or greater
Lyric Gateway firmware version 1.02 or greater
DIMENSIONS
3.15" x 2.44" x 0.55"
(80cm x 62cm x 14cm)
ELECTRICAL
Input Power:
7. 2 V
Current Drain:
245mA
RF
Antenna:
Integrated LDS Penta-Band antennas with
receive diversity for LTE CAT3. Average 1.2dBi gain.
ENVIRONMENTAL
Operating Temperature:
-4° to 131° F (-20° to 55° C)
Storage Temperature:
-40° to 158° F (-40° to 70° C)
AGENCY LISTINGS
ETL listed SPECIFICATIONS
LYNX Touch 4G
Communicators
(LTE-L57V/
LT E- L 57A )
L3000 4G LTE
Communicators
(LTE-L3A)
DESCRIPTION
Integrated Volte-capable LTE CAT1 cellular
communicator for LYNX Touch
PANEL COMPATIBILITY
L5210/L7000 controls version 9.00.xxx
DIMENSIONS
4.75" x 2.5"
(12.1cm x 6.4cm)
ELECTRICAL
Input Power:
5V
Current Drain:
490mA
RF
Antenna:
Internal Penta-Band antenna with receive
diversity for LTE CAT1. Average 2.4 dBi gain.
ENVIRONMENTAL
Operating Temperature:
-4° to 131° F (-20° to 55° C)
Storage Temperature:
-40° to 158° F (-40° to 70° C)
AGENCY LISTINGS
ETL Listed
DESCRIPTION
Integrated VoLTE capable LTE CAT1 cellular
communicator for LYNX Plus
PANEL COMPATIBILITY
• LYNX Plus Controls
• L3000 Series
DIMENSIONS
5.25" x 2.25"
(13.3cm x 5.7cm)
ELECTRICAL
Input Power:
8VDC
Current Drain:
315mA
RF
Antenna:
Internal Octa-Band antenna with receive
diversity for LTE CAT1. Average 3.8 dBi gain.
ENVIRONMENTAL
Operating Temperature:
-4° to 131° F (-20° to 55° C)
Storage Temperature:
-40° to 158° F (-40° to 70° C)
AGENCY LISTINGS
Listings pending For more information
www.honeywell.com/security
Honeywell Homes
2 Corporate Center Dr. Suite 100
P.O. Box 9040
Melville, NY 11747
1.800.323.4576
www.honeywell.com
L/LTEFAMD/D | 02/18
© 2018 Honeywell International Inc.
ORDERING
LTE SK U
Carrier
Panel
Compatibility
Replaced 3G/
CDMA Radio
LYRICLTE-A
AT&T
LCP500-L
LCP300-L
LYRIC-3G/LYRIC-CDMA
LTE-X V
Verizon
VISTA-15P
VISTA-20P
VISTA-128BPT
VISTA-250BPT
GSMX4G/CDMA-X
LTE-L57V
Verizon
L5210
L7000
3GL/CDMA-L57
LTE-L3A
AT&T
L3000
GSMVLP4G/CDMA-L3
LTE-X A
AT&T
VISTA-15P
VISTA-20P
VISTA-128BPT
VISTA-250BPT
GSMX4G/CDMA-X
LTE-L57A
AT&T
L5210
L7000
3GL/CDMA-L57
U.S.