CDMA-L57 Cellular Communications Module Installation Guide
For Documentation and Online Support: http://mywebtech.honeywell.com

General Information
The CDMA-L57 Cellular Communications Modules allow the LYNX Touch L5210 and L7000 controls to communicate with
the Central Station via the CDMA cellular network.

Installing the CDMA-L57 in the LYNX Touch Series Control
1. Install the provided FCC label (800-21260) on the control’s case back (see diagram below).

Typical FCC/IC Label Location (L5210 shown)
2. Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the unit with
the blade of a medium size screwdriver (see diagram below).
3. Install the CDMA-L57 into the LYNX Touch control front case as shown. Ensure that the connector board is properly
seated into the receptacle on the control.
4. Secure the CDMA-L57 with the three provided screws.
5. Enable the CDMA-L57 device, configure alarm reporting and module supervision and register the device. Refer to the
“Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and Setup Guide (P/N 80019974 or higher).

Installing the CDMA-L57 in the LYNX Touch (L5210 Shown)

Checking Signal Strength
When choosing a suitable mounting location, check the communicator’s signal strength to ensure proper operation. For
most installations, using the module’s internal antenna, mounting the control as high as practical, and avoiding large metal
components provides adequate signal strength for proper operation. Use the “CDMA Information” screen to display signal
strength (in dBm).
Select: Security > More > Tools > [Installer Code] > Program > Comm. Diagnostics > CDMA Information
Primary Site RSSI Level Signal strength is displayed by a series of 1 to 5 stars (* weak to ***** strong) or “Not Present” if
there is no signal. To ensure a reliable installation at least 2 (**) stars should consistently be present.
If necessary, relocate the Control to obtain better signal strength (press CDMA Information again to refresh the reading) or
install an external antenna.

Specifications
Voltage Input
Current
Idle
Average
Peak
Environmental
Operating
Temperature
Storage
Temperature
Humidity

CDMA RF Features

External Antenna Kit

5V (provided by the control panel)
75 mA, standby
575mA, average transmit
1.6A peak transmit, 25% duty cycle

Important Note About External Antennas
If an external cellular radio antenna is used, the antenna
may be installed or replaced ONLY by a professional
installer.
To the Installer
The external antenna must not exceed a maximum
directional gain (including cable loss) of 3.2 dBi at 850
MHz and 2.3 dBi at 1900 MHz.

-20ºC to +55ºC (for compliance
agency: 0ºC to +49ºC)
-40º to +70ºC
0 to 95% relative humidity, noncondensing (for compliance agency
0% to 85%)
• Dual-band support for both the
800MHz cellular and 1.9GHz
PCS bands.
• Adheres to CDMA
authentication as specified in
CDMA 1X.
• Support for IS-95A/B and
CDMA 1X Release 0/A.
CELL-ANTHB

Support & Warranty
For the latest documentation and online support, please
go to: https://mywebtech.honeywell.com/
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa.
For patent information, see www.honeywell.com/patents

MyWebTech

Warranty

Patents

FEDERAL COMMUNICATIONS COMMISSION (FCC) STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or User's Manual. Unauthorized changes
or modifications could void the user's authority to operate the equipment.

FCC CLASS B STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions,
may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a Class B computing device in accordance
with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference in a residential installation.
However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.

INDUSTRY CANADA CLASS B STATEMENT
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.

FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the following two conditions: (1) This device may not cause
harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son fonctionnement est soumis aux conditions suivantes: (1)
Cet appareil ne doit pas causer d' interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une réception
indésirable.

RF Exposure Warning
The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 7.8 in (20 cm) from all persons and must not be
co-located or operated in conjunction with any other transmitter except in accordance with FCC multi-transmitter product procedures.

Mise en Garde
Exposition aux Frequences Radio: L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins 7,8 pouces
(20 cm) de toutes les personnes.

2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2015 Honeywell International Inc.
www.honeywell.com/security

Ê800-21259LŠ
800-21259 11/15 Rev. A


Uploaded