Honeywell FG-1625 and FG-1625T Data Sheet
Related Products
Related Categories
Document Transcript
FG-1625/1625T
GLASSBREAK DETECTOR
The FG-1625 Glassbreak Detector uses the latest technology to provide faster response and increased false alarm immunity. The FG-1625 is specifically designed to allow fast, easy installation, while the adjustable sensitivity
settings can compensate for the acoustics of any room. Optimum operation can be quickly verified using the FG-701 Glassbreak Simulator.
FEATURES
• FlexCore™ Signal Processor The FlexCore Signal Processor is an Application-Specific Integrated Circuit (ASIC), which processes sound data in parallel rather than sequentially for faster, more accurate detection decisions. The combination of proven FlexGuard performance with the speed of FlexCore processing provides unmatched false alarm immunity without compromising detection. • Easy Installation and Setup Honeywell’s patented technology allows remote activation of Test Mode (with simulator). The FG-1625 has a centered wire entry hole, 45° terminal blocks and EOL terminals. A hand-clap feature verifies that the detector is functioning. • Mounting Locations The FG-1625 can be mounted on the ceiling, opposite wall, adjoining wall or the same wall as the glass.
®
• Selectable Sensitivity Two DIP switches on the FG-1625 make it easy to set the sensitivity to match the acoustics of the room. Four different sensitivity levels are available, ranging from very low to high. The range can then be verified remotely with the FlexGuard FG-701 Glassbreak Simulator. • Mount the Detector Anywhere Mounts on any wall, in the window frame, or on the ceiling, with no minimum range and a maximum range of 25' (7.6m) to the glass. • Covers All Glass Types The FG-1625 works on all glass types, including plate, tempered, laminated, wired, film-coated and sealed insulating glass.
• Multiple Domain Signal Analysis The FG-1625 performs Multiple Domain Signal Analysis in which time, frequency and amplitude characteristics are evaluated for signal qualification. This enables the detector to accurately discriminate false alarms from true glassbreak events. • Enclosed PC Board The PCB is protected from potential damage during installation. • Patented Remote Test Mode The Patented Remote Test Mode can enabled or disable the indicator LEDs using the FG-701 Glassbreak Simulator. The unit automatically resets from Test Mode in five minutes.
FG-1625/1625T
GLASSBREAK DETECTOR
SPECIFICATIONS
Physical Dimensions • White high impact ABS plastic housing • 3 7/8" H x 2 2/5" W x 7/8" D (98mm x 62mm x 21.8mm) Weight • Product Only: 3.2oz (90g) • Pkgd Product: 4.1oz (116g) Range • 25' (7.6m) maximum, omnidirectional. Range is adjustable; no minimum range Alarm Relay • FG-1625: Form A, 125mA max, 25VDC max • FG-1625T: Form C, 125mA max, 25VDC max Tamper Switch (FG-1625T only) • Combination cover/wall tamper 25mA max, 24VDC max Alarm Duration • Five seconds (unaffected by alarm LED latching) ESD Immunity • 10kV discharges of either polarity to exposed surfaces
Type* Plate 3a Tempered Laminated Wired Coated 2,3b Sealed Insulating 1,3b Minimum 2.4mm (3/32") 3mm (1/8") 3mm (1/8") 6mm (1/4") 3mm (1/8") 3mm (1/8") Maximum 10mm (3/8") 10mm (3/8") 14mm (9/16") 6mm (1/4") 6.4mm (1/4") 6mm (1/4")
Power Requirements • 6 - 18VDC, 12mA typical at 12VDC; 22mA max (Latched LED) • AC ripple: 4V peak-to-peak at nominal 12VDC RFI Immunity • 30V/m, 10MHz - 1000MHz Operating Temperature • 14° to 122° F (-10° to 50° C) • Storage: -4° to 122° F (-20° to 50° C) Approvals and Listings • • • • • FCC and IC verified CE C-Tick UL Listed ULC Listed
1 Protected only if both plates of the unit are broken. 2 Coated glass with security films, including films for solar protection, up to 12mil. thick may be used. Film Technologies International, Inc.’s GLASS-GUARD® GGLL 1200 has been evaluated with this product by Underwriters Laboratories, Inc. 3 In compliance with Underwriters Laboratories of Canada’s Standard for Intrusion Detection Units (CAN/ULC-S306-M89): a. Plate glass 3mm to 10mm can be used. b. ULC recognizes a maximum range for protecting sealed insulated glass and coated glass of 12.5ft. (3.8m).
Glass Type/Thickness
Note: The FG-1625/1625T detects shattering of framed glass by direct impact. It may not consistently detect breakage by blows that only crack the glass, by high velocity projectiles such as bullets, or glass broken without an impact. Accessories Description • FG-701 P/N 0-000-701-0 Glassbreak Simulator FlexGuard® Glassbreak Simulator/Tester • The sound of breaking glass is digitally simulated by the FG-701. The FG-701 is compatible for testing all Honeywell glassbreak detectors. Honeywell highly recommends testing glassbreak detectors before final installation.
(Maximum overall 7/16")
* Minimum size for all types is 28cm (11") square; glass must be framed in the wall or mounted in a barrier at least 0.9m (36") wide.
ORDERING
FG-1625 FG-1625T Glassbreak Detector Glassbreak Detector with Tamper
Honeywell Security & Custom Electronics Honeywell International Inc. PO Box 9035 Syosset, NY 11791 www.honeywell.com
L/FG1625/D January 2007 © 2007 Honeywell International Inc.