800-08115 1/11 Rev. B

GSMVLP5 GSM and ILP5 Ethernet Communications Modules Installation and Setup Guide
Installing Communication Modules
RF Exposure WARNING: The antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be co-located or operating in conjunction with any other antenna(s) or transmitter.

Installing the GSMVLP5 in the LYNX Touch Series Control
Ensure that SIM card and the connector board are securely installed in the GSMVLP5 before installing the module in the LYNX Touch.

1. Install the provided FCC/IC label (P/N 800-08334) on the control’s case back (refer to Figure 1).
LYNX TOUCH SERIES
FCC ID: CFS-8DLLYNXTOUCH1 IC: 573F-LYNXTOUCH1 IC MODEL: LYNXTOUCHG1 CONTAINS TRANSMITTER MODULE FCC ID: QIPMC55I IC: 7830A-MC55I
800-08334 2/11 Rev A

LYNX TOUCH SERIES
FCC ID: CFS-8DLLYNXTOUCH1 IC: 573F-LYNXTOUCH1 IC MODEL: LYNXTOUCH1

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND RSS 210 OF INDUSTRY CANADA. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION. COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION NO.: AC3AL05BL5000 RINGER EQUIVALENCE: 0.1B
800-08126 1/11 Rev A

5000-100-186-V0

Figure 1. FCC/IC Label Location 2. Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver (Refer to Figure 2). 3. Install the GSMVLP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on the control (Refer to Figure 2). 4. Secure the GSMVLP5 with the three provided screws (Refer to Figure 2). 5. Enable the GSMVLP5 device, configure alarm reporting and module supervision and register the device. Refer to the “Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and Setup Guide (P/N 800-06834 or higher). For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/MyWebTech

CONNECTOR BOARD

SCREW (3)

CONNECTOR BOARD SIM CARD

ROTATED 180

GSMVLP5

RECEPTACLE

LYNX TOUCH

LOCKING TABS

5000-100-151-V1

Figure 2. Installing the GSMVLP5 in the LYNX Touch

Installing the ILP5 in the LYNX Touch Series Control
Ensure that the connector board and cable are securely installed in the ILP5 before installing the module in the LYNX Touch.

1. Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver (Refer to Figure 3). 2. Using a wire cutter or knife cut the plastic tabs that secure the ILP5 spacer to the back case of the LYNX Touch (Refer to Figure 3). 3. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case (Refer to Figure 3). 4. Install the ILP5 into the LYNX Touch control front case. Ensure that the connector board is properly seated into the receptacle on the control (Refer to Figure 3). 5. Secure the ILP5 with the three provided screws (Refer to Figure 3). 6. Insert the ILP5 receptacle and spacer into the slot on the back case (Refer to Figure 3). 7. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap (Refer to Figure 3). 8. Enable the ILP5 and configure alarm reporting and module supervision and register the device. Refer to the “Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and Setup Guide (P/N 800-06834 or higher). For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/MyWebTech

ETHERNET CABLE TO ILP5

RJ45 RECEPTACLE LYNX TOUCH

ALTERNATE INSTALLATION
ILP5 SPACER

REMOVE ILP5 KNOCKOUT

REMOVE ILP5 SPACER

CONNECTOR BOARD

RJ45 RECEPTACLE ROTATED TIE 180 WRAP (1)

TIE WRAP POINT

CONNECTOR BOARD

SCREW (3)

ILP5

RECEPTACLE

LYNX TOUCH

LOCKING TABS

5000-100-154-V1

Figure 3. Installing the ILP5 in the LYNX Touch

Electrical Specifications
GSMVLP5
Voltage Input Current Idle Average Peak 5V 15 mA, standby 300mA, average transmit 1.6A peak transmit, 25% duty cycle

ILP5
Voltage Input Current: 5V 83 mA, 100 Base T with traffic 41 mA, 10 Base T with traffic