The 4193SN is a serialized two-zone expander used t
o connect alarm sensing devices to
controls that support serial number polling loop de
vices (e.g.,
Vista-50P, Vista-128BP and Vista-250FBP).
The ADEMCO 4193SN can be configured as one supervis
ed zone (10K EOLR) and one
unsupervised zone (normally closed devices only).
Consult the control panel installation instructions
for programming information.
S
pecifications:
Physical:
2-1/2”W x ½”H x ½”D
Weight:
0.8 ounces (22.7grams)
Voltage:
8-12VDC (as supplied from the Honeywell Security
Control Panel V-Plex polling loop).
Input Current:
1.5mA
Operating Temperature:
32°F to 120°F (0°C to 49°C)
Max. Relative Humidity:
93%
Max.
Zone
Line Impedance:
300 ohms
Max.
V-Plex Polling Loop Impedance:
20 ohms
GREEN (LOOP 2) UNSUPERVISED
BLACK (COMMON)
WHITE (LOOP 1) SUPERVISED EOLR 10K
(CLASS B)
RED (+)
BLACK (–)
4193SN-002-V3
YELLOW (LOOP 1) UNSUPERVISED
WIRING DIAGRAM
POLLING
LOOP
For Fire Applications:
The 4193SN must be mounted inside the control panel
or inside a UL-Listed junction box. Loop
1 (supervised) may be used in the supervised config
uration for Fire. Use Honeywell End-Of-Line
resistor model number EOL100, 10K ohms, on Loop 1.
Loop 1 of this module can be used with
four wire smoke detectors, heat detectors and pull
stations. Polling loop is Class B, Style 3.
For UL Burglary Applications:
Loop 1 must be used
in the supervised configuration for commercial Bur
glar Alarm systems.
For Household applications, Loop 1 is used in the u
nsupervised configuration or Loop 2 may
be used, according to the following condition: if u
sing an unsupervised zone of the ADEMCO
4193SN, the unit
must be mounted within 3 ft of the alarm initiating
device
, with no
intervening barriers.
Notes:
1. All circuits are power-limited.
2. For dry indoor use only.
3. Do not install in air-handling spaces.
Ê12Š
QTY 1
Ê4193SN0Š
4193SN
Country of Origin: Mexico
of 2


Related Products

Honeywell Home 4193SN - V-Plex, Two-Zone Adapter/Expander
Honeywell Home 4193SN
V-Plex, Two-Zone Adapter/Expander
List Price:
Our Price: $20.99

Document Transcript




V-Plex
®
Two Zone Expander

ADEMCO 4193SN
For connecting alarm sensing devices and switches t
o
ADEMCO V-Plex Polling Loop systems
Quantity: 1 ea
.
Requires control panel with SERIAL NUMBER device ca
pability
(e.g., Vista-50P, Vista-128BP, Vista-250FBPT)
Consult control panel instructions for compatibilit
y





















ÊN7644V6CcŠ
N7644V6C 3/15 Rev. C Installation Instructions

The 4193SN is a serialized two-zone expander used t
o connect alarm sensing devices to
controls that support serial number polling loop de
vices (e.g.,
Vista-50P, Vista-128BP and Vista-250FBP).

The ADEMCO 4193SN can be configured as one supervis
ed zone (10K EOLR) and one
unsupervised zone (normally closed devices only).
Consult the control panel installation instructions
for programming information.

S
pecifications:
Physical:
2-1/2”W x ½”H x ½”D

Weight:
0.8 ounces (22.7grams)
Voltage:
8-12VDC (as supplied from the Honeywell Security
Control Panel V-Plex polling loop).
Input Current:
1.5mA
Operating Temperature:
32°F to 120°F (0°C to 49°C)

Max. Relative Humidity:
93%

Max.

Zone

Line Impedance:
300 ohms
Max.

V-Plex Polling Loop Impedance:
20 ohms


GREEN (LOOP 2) UNSUPERVISED
BLACK (COMMON)
WHITE (LOOP 1) SUPERVISED EOLR 10K
(CLASS B)
RED (+)
BLACK (–)
4193SN-002-V3
YELLOW (LOOP 1) UNSUPERVISED
WIRING DIAGRAM
POLLING
LOOP

For Fire Applications:
The 4193SN must be mounted inside the control panel
or inside a UL-Listed junction box. Loop
1 (supervised) may be used in the supervised config
uration for Fire. Use Honeywell End-Of-Line
resistor model number EOL100, 10K ohms, on Loop 1.
Loop 1 of this module can be used with
four wire smoke detectors, heat detectors and pull
stations. Polling loop is Class B, Style 3.

For UL Burglary Applications:

Loop 1 must be used
in the supervised configuration for commercial Bur
glar Alarm systems.
For Household applications, Loop 1 is used in the u
nsupervised configuration or Loop 2 may
be used, according to the following condition: if u
sing an unsupervised zone of the ADEMCO
4193SN, the unit
must be mounted within 3 ft of the alarm initiating
device
, with no
intervening barriers.
Notes:

1. All circuits are power-limited.
2. For dry indoor use only.
3. Do not install in air-handling spaces.

Ê12Š
QTY 1


Ê4193SN0Š
4193SN

Country of Origin: Mexico