PROSiXCT

Wireless Door/Window Sensor


Installation Instructions


The
PROSiXCT

is a
two
-
zone

wireless door /
window
sensor
with
cover and
wall
tamper
. It is

intended for use with Honeywell
Home
controls
that support
PRO
SiX

series devices.


The
PROSiXCT
can be installed
with
two
options:


Reed switch
with magnet:

Make gap is 0.75"; Break gap is 1.30".


Optional
wiring for external contact
loop:

a) surface wiring

b) concealed wiring


Mount
the
PROSiXCT

1. To open the case, f
irmly s
lide the front
and
back

housings in opposite directions and
pull them
apart
to open the device.

2. Mount sensor as shown using the double-
sided

tape and screws provided.

3. If us
ing an
external
contact
, connect
its wires to
the
terminal block.


NOTE
: Wiring limit is 3ft.

4. Secure the front cover with the #2 x 1/4” screw.

After enrolling
and before mounting, verify
adequate signal strength by conducting a
sensor
test
(see controller’s instructions) with the device in
its intended mounting location. Adjust the device
location
and orientation as necessary.


Signal Strength Guide

Signal strength: R
ange of 1
-4 bars (green); should be
minimum 1 green bar
for the Zone being programmed.
Four red bars indicate poor signal strength; the device
should be relocated.


See the Control’s
instructions for bar indication signal
strength values.


Icon

Description

Signal Strength


Four Green Bars

Good


Three Green Bars


Two Green Bars


One Green Bar


Four Red Bars

Relocate the device



2

Enroll and Set Up


You must enroll the device in the control. Refer to the
control's programming instruction for detailed procedures

Set
the
controller
in Programming Mode, when prompted:

1. Pull
the
battery tab
to activate the
PROSiXCT
. (Use
the magnet if the battery tab is removed.)

2. The LE
D flashes (
up to about
20 seconds*
) during
enrollment.


Both services (Reed and Terminal Block) are
enrolled in sequential (or next available) zone
numbers.


The device sends its uniq
ue MAC ID (
Serial
Number)
; the control
ler registers the device and
displays
the transmitter data on screen
.
*NOTE
: Enrollment time varies depending on the signal
strength between the device and the controller.

3. When
done,
the LED is ON for 3 seconds and the
control beeps
to confirm
enrollment.

NOTE
: If the device is not succes
sfully enrolled during the
enrollment period, the LED turns off and the device powers
down. Activate a tamper, wired service (loop) or the reed
switch to restart the enrollment process.

4. Program
each zone being used.




Reed Switch
Zone



Terminal B
loc
k Zone



IMPORTANT
:Once enrolled in a system, the PROSiXCT

cannot be used with another controller until it is removed
from the current controller. See the Controller’s
instructions for details.

Sensor Location Feature
(if available)
:
To verify the
location of each
PRO
SiX device in an installation, enter
programming mode and select a
PRO
SiX device. The
device LED lights
(can take up to 30 seconds)
. Select it
again to turn the LED off or select the next device to
locate.


24
-Hour
Enrollment
Deletion and Default

If the device is enrolled in a panel different than the
intended panel, and you are unable to delete it from
the unintended panel, reset
the device
to factory
default setting:

1. Open the cover and remove the battery.

2. Hold down the tamper switch while reinserting the

battery.
Rapid LED flashing indicates successful
deletion (LED flashes as if in enrollment mode). If
LED does not flash, delete was not successful.

3.

Reattach the cover.



This procedure is available for 24 hours after enrollment with a
panel and the devic
e remains powered (battery installed).

3
LED Indications


LED

Status



Rapid Flashes for

about 20 seconds, then

ON for 3 seconds

Power Up –
Enrollment


Slow Flashes

Power Up –
Device enrolled;
Wall
or Cover
Tamper activated. To stop
flashes,
clear the tamper condition
by
reconnecting to the mounting plate
and reattaching the cover
. It also
times out after 10 minutes.


ON

(while in Programming Mode)

Sensor LED toggles on and off when the sensor is selected. See Sensor
Location Feature.


Battery Re
placement


Push the bottom latch of the
mounting bracket back to disengage
it. Then
slide the back housing, up
and out to remove
it from the
mounting
bracket
.


Slide the front and back housings in
opposite directions
and pull the
housings apart
.

Re
move
the battery
,
wait
10
seconds
,
then insert a new battery
.
Recommended batteries:

Duracell DL123A


Honeywell 466

Huiderui CR123A


Panasonic CR123A


Place the front and back housings
together and slide them together as
shown.

BATTERY CAUTION
: Risk of fire,
exp
losion and burns.
Do not recharge,
disassemble, heat above 212°
F (100°
C)
or
incinerate. Dispose of used batteries
pro
per
ly. Keep away from children.

NOTE
: Constant exposure to high or low
temperature or high humidity may reduce
battery life.


Specificat
ions
:
Battery:
1 x 3V Lithium, Honeywell 466, Panasonic CR123A,

Duracell DL123A or Huiderui CR123A

Tamper:
Cover and Wall

RF Frequency
:
2.4GHz

Operating Temperature
: 32°
– 122° F / 0°
– 50° C

(Agency Compliance 32°
– 120° F / 0°
– 49° C)

Relative
Humidity:
95% max. (Agency Compliance -
93% max.),
non-
condensing

Dimensions:
1” H x 3.13” L x 1.61” W / 25.5 mm H x 79.5 mm L x 41 mm W


Approval Listings:

FCC / IC

cETLus Listed

Conforms to UL 634

Certified to ULC/ORD
-C634

Other Standards:

RoHS


Product must be tested at

least once each year




FEDERAL COMMUNICATIONS COMMISSION & INDUSTRY CANADA STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or U
ser's M
anual.
Unauthorized changes or modifications could void the user's authority to operate the equipment.



CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the followi
ng statement for your
information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in st
rict accordance with the
manufacturer's instructions, may cause interference to radio and television reception. It has been type tested and found to comply with the limits for a
Class B computing device in accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable protection against
such interference in a residential inst
allation. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause interference to radio or television reception, which can be determined by turning the equipment off and on, the us
er is enc
ouraged to try to
correct the interference by one or more of the following measures:


If using an indoor antenna, replace with a quality outdoor antenna.


Reorient the receiving antenna until interference is reduced or eliminated.


Move the radio or televis
ion receiver away from the receiver/control.


Move the antenna leads away from any wire runs to the receiver/control.


Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different branch cir
cuits.


Consult
the dealer or an experienced radio/TV technician for help.

INDUSTRY CANADA CLASS B STATEMENT

This Class B digital apparatus complies with Canadian ICES
-003.

Cet appareil numérique de la classe B est conforme à la norme NMB
-003 du Canada.

FCC / IC STATEMENT

This device complies with Part 15 of the FCC Rules, and
Industry Canada’s license-
exempt
RSSs
. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause
undesired operation.

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement est soumis aux
conditions suivantes: (1) Cet appareil ne doit pas
causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les
interférences causant une r
éception indésirable.


Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resi
deo Technologies, Inc., 2 Corporate Center Drive.,
Melville, NY 11747, Ph: 516
-
577
-
2000

RF EXPOSURE

Warning
– The antenna(s) used for this device must be installed to provide a separation distance of at least 7.8 inches (20 cm)
from all persons and must not be co-located or operating in conjunction with any other antenna or transmitter except in accordance
with FCC and ISED multi
-transmitter product procedures.

Mise en Garde

Exposition aux Fréquences

Radio
:
La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent être installée(s) à une distance de
séparation d'au moins 20 cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner parallèlement à tout autre
transmetteur ou antenne, excepté en conformité avec les procédures de produit mul
ti transmetteur FCC et ISED
.


The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The
correct disposal of end-
of-life equipment will help prevent potential negative
consequences for the environment and human health.

Support and Warranty

REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING
LIMITATIONS OF THE ENTIRE ALARM SYSTEM.

For the latest documentation and on
line support information, please go to:

https://mywebtech.honeywell
home.com/


For the latest warranty information, please go to:

https://www.security.honeywellhome.com/hsc/resources/wa/index.html

For patent information, see https://www.resideo.com/patent




MyWebTech


Warranty


Patents


The Honeywell Home Trademark is used under license from Honeywell International Inc.

This product is manufactured by Resideo
and its affiliates.


2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747

2019
Resideo Technologies, Inc.
www.resideo.com



Ê800
-
252369Š

PROSiXCT
800
-25236
2/19
Rev A






Uploaded