MOUNTING GUIDELINES
The
PROSiXGB
can be mounted
on the wall or on the ceiling
:
•
within 7.6 m (
25 feet) of the
protected glass
•
within clear view of the protected
glass
•
at leas
t 2 m (6.5 feet) from the floor
•
at least 1 m (3.3 feet) from forced
air ducts
•
at least 1 m (3.3 feet) from sirens or
bells greater than 5 cm (2 inches) in
diameter
•
between the protected glass
and
any heavy w
indow coverings
•
when heavy window coverings are
present, the detector can
be
mounted on the window frame
•
Avoid mounting the detector on the
same wall as the protected glass,
on free
-standing posts or pillars, or
in rooms with noisy equipment (air
compressor
s, bells, power tools,
etc.), if this equipment is operated
when the detector is armed.
To
remove the mounting bracket:
Turn the top of the detector 15
degrees
counter
-
clockwise and separate
the mounting bracket
.
NOTE
: Before mounting the device
per
manently,
conduct
a sensor test (see control
ler
’s
instructions) to verify adequate signal
strength and adjust the device location and
orientation as necessary.
The rear tamper plate MUST be mounted to a stud,
solid wood, or with a robust wall anchor.
2
EN
ROLL
Set the c
ontroller
in Programming Mode and
when prompted:
1. Remove
the
battery tab
to activate the device and begin the enrollment process
.
2. The
Green
[G1]
1
LED flashes during enrollment (
up to
about
20
seconds
*) The device sends its unique MAC ID
(Se
rial Number) and Services information to the controller.
*NOTE
: Enrollment time varies depending on the signal strength between the device and the controller.
3. The
Green
[G1]
LED is ON for 3 seconds
.
If the sensor is not successfully enrolled during the enr
ollment period, the LED turns off and the device powers down.
Activate the tamper, power down and up again, or use the FG
-701 Glassbreak Simulator to restart the enrollment
process.
1
Refer to the
PROSiXGB
LEDs
section.
NOTE
: Once enrolled in a system, the
detector cannot be used with another controller until it is removed from the
current controller. See the Controller’s instructions for details.
PROGRAM THE PROSIXGB
Consult the Control
ler
’s instructions for programming
the device in the system.
Adj
ust the detector sensitivity setting in the controller
programming mode. Refer to
the table
on the right
for
sensitivity options.
Sensitivity Setting
Approximate Range
High
*
4.6-
7.6m / 15-
25 ft.
Medium
3-4.6m / 10-
15 ft.
Low
1.5-
3m / 5
-10 ft.
Lowest
0-1.5m / 0
-5 ft.
*Factory
default
. Change the sensitivity setting at
the Controller
.
3
PROSIXGB LEDS
The
detector
has three LEDs which are visible when
the unit is mounted.
Green
1
[G1]
LED indicates device enrollment
and
tamper status.
Th
e Red [R]
and
Green
2 [G2]
LEDs
provide
information on detector status
during Test Mode. The
Green
2
LED
indicates events and the
Red
LED
indicates Alarms.
LED INDICATIONS TABLE
G1
Red
G2
Status
1
10 minute Test Mode
Event
detected
during Test Mode
Alarm
detected
during Test Mode
2
2
Low Battery
detected during Test Mode
Device not enrolled; Enrollment activated
Device enrolled and t
amper
detected
NOTE
: Before using the Test Mode, the detector must first be enrolled in the controll
er.
1
If the
PROSiXGB
Test Mode is activated by the FG701, the
[G2
] LED will flicker, then be off for 3 seconds, then flash once per s
econd.
2
This feature is used for field diagnosis.
To save power, t
he LEDs are not visible during Normal Mode
.
TEST THE
PROSIXGB
The
detector
should be tested after installation and at least once a
year.
Test Mode can be activated remotely from the Control
ler (see
Controller’s
manual), or on-
site with an FG
-701 Glassbreak
Simulator, only when the system is
disarmed
.
Foll
ow directions in the FG
-701 Glassbreak Simulator Operating
Instructions to activate and test the
PROSiXGB
detector.
BATTERY REPLACEMENT
1. Twist the front cover counterclockwise 15 degrees
and separate it
from the mounting bracket
.
2. Remove
the
old
battery
.
3. Wait 10 seconds
.
4. Insert a new battery. R
eplacement batteries:
Resideo
466,
Panasonic CR123A
Duracell D123,
Duracell D
123A
5. Carefully realign the front cover as shown
;
reattach
and twist
the front cover 15 degrees
clockwise
to lock it in place.
BATTERY CA
UTION
: Risk o
f fire, explosion and burns.
Do not recharge, disassemble, heat above 100°
C (212°
F) or
incinerate. Dispose of used batteries proper
ly. Keep away from
children.
SPECIFICATIONS
Range:
0’- 25’/ 0 –
7.6m; Selectable
Battery
: 1 x 3V, Lithiu
m;
Resideo
466,
Panasonic
CR123A,
Duracell DL 123, Duracell DL 123A
Tamper
: Cover and Wall
RF Frequency
: 2.4GHz
Operating Temperature
: 0° to 50° C / 32° to 122° F (Agency compliance 0° to 49° C
/ 32° to 120° F)
Relative Humidity
: 95%
max.
(Agency c
ompliance
– 93%
max.
), non
-condensing
Dimensions
: 96 mm Diameter x 29mm Thick / 3.78
”
Diameter x 1.14
”
Thick
APPROVAL LISTINGS
FCC / IC
cETL
us Listed
Conforms t
o UL
639
Certified to
ULC-
S306
Other Standards:
RoHS
Protected Glass Types Chart
NOTE:
The
PROSiXGB
is NOT recom
mended for protection of glass areas smaller than 27.6 cm x 27.6 cm (10-
7/8 inches x 10-
7/8 inches).
Glass Type*
Nominal Thickness
Minimum
Maximum
Plate
3a
2mm (3/32 in.)
10mm (3/8 in.)
Tempered
3mm (1/8 in.)
10mm (3/8 in.)
Lam
inated
1
4mm (5/32 in.)
14
m
m (9/16 in.)
Wired
6mm (1/4 in.)
6mm (1/4 in.)
Coated
2
3mm (1/8 in.)
6mm (1/4 in.)
Sealed Insulating
3b
3mm (1/8 in.) [13mm (1/2 in.) overall]
6mm (1/4 in.) [19mm (3/4 in.) overall]
* Minimum size for all types is 28cm (11 in.)
square; glass must be fr
amed in the wall or mounted in a barrier at least 0.9m (36 in.) wide.
1
Protected only if both plates in the unit are broken
2
Coated glass with security films up to 0.35mm (14 mils) thick (including films for solar protection) may
be used. Evaluated with
the these products: 3M
®
SCOTCHSHIELD
®
SH14CLARL
– 0.35mm (14 mils), 4 ply film; Film Technologies International, Inc.’s GLASS
-GARD GGLL 1200 has been evaluated with this product by
Underwriters
Laboratories, Inc.
3
In compliance wi
th Underwriters Laborator
ies of Canada’s Standard for Intrusion Detection Units (CAN/ULC
-S306-
M89):
a. Plate glass 2.5mm (3/32 in.)
to 10mm (3/8
-in.) can be used.
b. Seal Insulating glass 4mm (5/32 in.) [15mm (19/32 in.) overall] to
6mm (1/4 in.) [(19mm) 3/4 in. overall] can be us
ed. Sensitivity should be set to High when protection
range is greater than 3.8m (12.5 ft).
FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS
The user shall not make any changes or modifications to the equip
ment unless authorized by
the Installation Instructions or User's Manual. Unauthorized changes or modifications could
void the user's authority to operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
This equipment has been tested and found to comply wi
th the limits for a Class B digital device, as defined by FCC Rules Part 15.105. The Class B Digital Device statement can be
viewed at:
https://customer.resideo.co
m/en
-US/support/residential/codes-and
-standards/FCC15105/Pages/default.aspx
FCC / IC STATEMENT
This device complies with Part 15 of the FCC Rules, and Industry Canada’s license
-exempt RSSs. Operation is subject to the following tw
o conditions: (1) This de
vice may not cause
harmful interference, and (2) This device must accept any interference received, including interference that may cause undesi
red operation.
Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industri
e Canada. Son fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne
doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris les interférences causant une récept
ion indésirable.
RF EXPOSURE
Warning
–
The antenna(s) used for th
is device must be install
ed to provide a separation distance of at least 7.8 inches (20 cm) from all persons and must not be co-located or operating
in conjunction with any other antenna or transmitter except in accordance with FCC multi
-transmitter product procedures.
Mise en Gar
de
Exposition aux Frequences Radio:
L'antenne (s) utilisée pour cet émetteur doit être installée à une distance de séparation d'au moins
7,8 pouces (20 cm) de toutes les personnes.
REFER TO THE INSTALLATION IN
STRUCTIONS FOR THE CONTRO
L WITH WHICH THIS DEVICE IS USED, FOR DETAILS REGARDING LIMITATIONS OF THE ENTIRE
ALARM SYSTEM.
Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsi
diary of Resideo Technologies, Inc., 2 Corporate Center Drive.,
Melville, NY 11747, Ph: 516-
577-
2000
The product should not be disposed of with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The
correct
disposal of end-
of-life equipment will help prevent potential negative consequences for the environment and human health.
Any attempt to reverse-
engineer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is stric
tly prohibited.
SUPPOR
T & WARRANTY INFORMATION
For the latest documentation
and
support, please go to:
www.resideo.com
For the latest warranty information, please go to:
www.security.honeywellhome.com/warranty
The Honeywell Home Trademark
is used under license from
Honeywell International Inc.
This pr
oduct i
s manufactured by Resideo
Technologies
, Inc.
and its affiliates.
Ê800
-
25231B+Š
800
-
2
5231
B
2/19
Rev
B
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville,
NY 11747
©
20
20
Resideo T
echnologies, Inc.
www.resideo.com
- Uploaded