PROSiXPANIC

2
-
Button Wireless Panic
Sensor

Installation Instructions

T
his bi
-
directional wireless panic
sensor

is intended for
use with Honeywell Home
controls that support

PRO
SiX™ series devices.

To activate, press and hold both buttons briefly until the
LED flashes. To clear the alarm at the control, enter a
user code. To clear memory of alarm, select Disarm
and enter a user code.



The device can be used with a belt clip, lanyard, or
wristband.


LED Indications

Green flashing:
lights when unit is t
ransmitting

Red Flashing:

indicates low battery (lights during
button
press)


Enroll and Program the PROSiXPANIC

Follow instructions in the Controller’s programming guide.

1. Set the c
ontroller in Programming Mode
and when prompted:

2. Press and hold both bu
ttons briefly until the LED flashes to activate the enrollment
process.

3. The LED flashes green during enrollment (up to about 20 seconds).
The device sends
its unique MAC ID (Serial Number) and Services information to the controller.

NOTE
: Enrollment time v
aries depending on the signal strength between the device
and the controller.

4. When done, the LED lights solid green for 3 seconds to confirm enrollment.

If enrollment is not confirmed, press and hold both buttons briefly again to restart the
enrollment process.

IMPORTANT
: Once enrolled in a system, the PROSiXPANIC
cannot be used with
another controller until it is removed
from the current controller. When removed from a
system, the
sensor
will revert to factory default settings.

After Enrolling:
Verify adequate signal strength by conducting a sensor test
(see
controller’s instructions).






24
-
Hour
Enrollment Deletion and Default


If the device is enrolled in a panel different than the intended panel, and you are unable
to delete it from the unintended
panel, reset the device to factory default setting:

Press and hold both buttons
for 15 seconds.
When successful, the LED comes back on
flashing.

The device self
-deletes from the panel it was enrolled in.

This procedure is available for 24 hours after enrollment with a panel and the device
remains powered (battery installed).

Press and hold both buttons for 15 seconds.



Battery Replacement

When the battery is low, the LED flashes red during transmission. To
replace the battery:

1.
Remove the screws from t
he back housing and use a screwdriver
to gently separate the front and back housings.

2.
Use a screwdriver to carefully remove the battery.

3.
Wait 10 seconds or press a button for 2 seconds to ensure full
power discharge.

4.
Insert a new 3V Coin Cell battery as shown. Recommended
replacement battery:

Recommended Batteries: 3V Coin Cell

Duracell DL2450;
Panasonic CR2450; Energizer CR2450

5.
Replace the front housing and secure the housings with the cover
screw.




BATTERY CAUTION
: Risk of fire, explosion and burns. Do not recharge,
disassemble, heat above 212°
F (100°
C) or incinerate. Dispose of used
batteries properly. Keep away from children.

NOTE
: Constant exposure to high or low temperature or high humidity
may reduce battery life.


Specifications

Bat
tery
: 1 x 3V Coin Cell, Duracell DL2450;

Panasonic CR2450; Energizer CR2450

RF Frequency
: 2.4GHz

Operating Temperature
: 0° to 50° C / 32° to 122° F

(Agency compliance 0° to 49° C / 32° to 120° F)

Relative Humidity
: 95%
max.
(Agency compliance –
93%
max.
),
non
-condensing

Dimensions
:
0.5” H x 1.5” L x 1.5” W / 13 mm H x 38 mm L x 38 mm W

Approval Listings
:
FCC / IC
cETL
us Listed

Conforms
to UL1023,

UL985, & UL1637

Certified to ULC ORD
-
C1023 & ULC
-S545

Other Standards:

RoHS

Prod
uct must be tested at least once each year.



IMPORTANT SECURITY NOTICE

Please inform the User about the security importance of their wireless
sensor
, and what to do if it is lost.

They should immediately notify the Dealer/Installer of a lost
or stolen se
nsor
. The Dealer/Installer will then remove the
sensor
programming from the security system.



FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized
by the Installation Instructions or User's Manual. Unauthorized
changes or modifications could void the user's authority to operate the equipment.

CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested and found to comply with the limits for a Cl
ass B digital device, as defined by FCC Rules Part 15.105. The Class B Digital
Device statement can be viewed at:

https://customer.resideo.com/en-
US/support/residential/codes
-and-
standards/FCC15105/Pages/default.aspx

FCC / IC STATEMENT

This device complies with Part 15 of the FCC Rules, and Industry Canada’s license-
exempt RSSs. Operation is subject to the following two conditions: (1) This

device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired
operation.

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Indus
trie Canada. Son fonctionnement est soumis aux conditions
suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence r
eçue y compris les interférences
causant une réception indésirable.


Resp
onsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate
Center Drive., Melville, NY 11747, Ph: 516-
577-
2000


RF EXPOSURE

Warning
– The antenna(s) used for this device must not be co
-located or operating in conjunction with any other antenna or transmitter except in accordance with
FCC and ISED multi
-transmitter product procedures.

Mise en Garde

Exposition aux Fréquences
Radio :
La/les antenne(s) utilisée(s) pour cet émetteur ne pas
être située(s) ni fonctionner parallèlement à tout autre transmetteur ou
antenne, excepté en conformité avec les procédures de produit multi transmetteur FCC et ISED.


REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH THIS DEVICE IS USED, FOR
DETAILS REGARDING LIMITATIONS OF THE ENTIRE ALARM SYSTEM.


Support and Warranty


For the latest documentation and online support information, please go to:

https://mywebtech.honeywell
home.com/


For the latest warranty information, please go to:
www.security.hone
ywellhome.com/warranty

For patent information, see

https://www.resideo.com




The product should not be disposed of with other

household waste. Check for the nearest authorized collection centers or authorized recyclers.
The correct disposal of end-
of-life equipment will help prevent potential negative consequences for the environment and human health.

Any attempt to reverse-
engi
neer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is strictly
prohibited.


The Honeywell Home Trademark is used under license from Honeywell International Inc.

This product is manufactured by Resideo and its affiliates
.

2 Corporate Center Drive, Suite 100
P.O. Box 9040, Mel
ville, NY 11747


2020
Resideo Technologies, Inc.
www.resideo.com



Home Health Care,
Household Fire &
Burglar Control
Unit Accessory





Ê800-25223B5Š

PRO
SiXPANIC 800
-
2
5223
B

2/19

Rev
B