Honeywell Home PROSIXRPTR - Install Guide Dated 4/20 Rev. D
Related Products
Related Categories
Document Transcript
PROSiXRPTR
Wireless Repeater
Installation
and Se
tup Guide
The
PROSiXRPTR
is an RF receiver and a
transmitter and is intended to extend the
indoor
range of PRO
SiX series
devices. T
he
PROSiXRPTR
receives alarm, status, and
control messages from PRO
SiX ser
ies
de
vices, and forwards these messages to
control panel. The control then responds
accordingly (arm/disarm the system, initiate an
alarm, etc.
).
FEATURES
•
Transmit
s its own status,
including
wall and
case
tamper, A
C l
oss,
low battery and RF
Jam.
•
Indicates
RF Ja
m, AC/Battery Status,
and
RSSI (
Received
Signal
Stren
gth
Indicator
)
using LED
’s.
•
RSSI indicates the signal condition
between the repeater and the control
.
•
Provides a 24
-hour backup rechargeable
battery
•
ETL
listed to meet UL
standar
ds.
•
Up
to 2 repeat
ers
per system
.
NOTE:
Repeater
1 does not
communicate with repeater 2
.
GENERAL GUIDEL
INES
•
Th
e PROSiXRPTR
module
uses a 5VDC power supply
to power the module and
charge the battery
.
•
The P
ROSiXRPTR
uses a 4.2VDC rec
hargeable backup battery.
I f the volt
age drops to
3.6VDC
a low
battery occur
s.
NOTE
S:
•
If the battery voltage falls below
2.6VDC, it is incapable of
charging
the battery; it must be replaced.
•
New
batteries may indicate they are low on initial startup;
however
, they
should reach sufficient charge in 1 hour
.
•
Before mounting permanently,
enroll the PROSiXRPTR
(see
control
’s instructions) to verify adequate signal strength, relocate if necessary.
•
PROSiXRPTR
is designed to operate 200
feet through three
walls of wood, aluminum and dry wall constr
uction.
When a single
repeater installation is requ
ired
.
•
Range of the
control
and sen
sor is mo
re t
ha
n
200
ft. lin
e of s
ight.
•
Signal
strength of sensors is
less than
2 bars
for
one or more sensors.
•
Walk Test Failure of any
PROSiX
Se
nsor
/ PROSiX
Keypad.
•
If installation requires more than two
floor communication.
•
If mo
re obstacles are
interfer
ing
(more
than
thr
ee walls, high density m
eta
l doors, wood doors, multiple con
crete walls
, etc.)
with
communication between sensor and
control
.
When a second rep
eater
ins
tallati
on is
required
.
S
ame as Single Repeater inst
allation exce
pt:
•
Range of the panel and sensor is more tha
n
500 ft line of site, then install the
control
in the m
id
dle
with repeaters on either
direction o
f the
panel.
•
If I
nstallation requir
es more t
han 3
floor
Communicat
ion
. Install
Controller
on the
middle Floor
; then
install Repeater
based
on the
steady
Amber
RSSI (Signal Streng
th)
LED indication as described in
LED table be
low
.
NOTE:
Maximum number of
the repeater all
owed in a system is two
. The
path of
transmission is
as follows: transmitter
repeater
control
. NOT tran
smitter
repeater
repeater
control.
COMPATIBIL
ITY (
REPEATER READ
Y SYSTEM
)
•
All
sen
sors (includin
g keyfobs
) conne
cted
to the
contro
l
re
q
u
ire
a firmware versio
n of
5.0.1
or
higher
.
•
The PROA7/PROA7PLUS control
panel fir
mware version
must be at revision 03.591.88 or
higher
.
NOTES:
•
If control
’s firmw
are
is less than that desc
ribed
above, th
en the control
will
ha
ve to be
updated
. Either by firmware update or full
control
replac
ement.
•
If the revision of the sensors is
less than 5.0.1
(i.e. pre
-existing
sensors),
the
contr
ol panel firmware m
ust b
e updated
in order to update the
sensor firm
ware
.
•
When updating the control and sensors, allow 24
-
hours for all the sensors to update
.
MOUNTING
NOTE:
for bes
t results mount the PROSiXRPTR
as high as possible, keeping it away from metal objects.
1.
Select a mounting position for the module.
IMPORTANT!
•
DO
NOT mount on
or inside a
metal enclos
ure/obj
ect.
•
Don't install near to WIFI
Routers,
Mic
rowave
Oven and
other
interfering devices. M
aintain at
least 10 feet
distance.
2. Attach to
the wall using the supplied screws.
3. Install the center screw to secure the back
tamper to t
he
wall.
4. Ensu
re the wirin
g is complete. Use cable ties
or staples
as
necess
ary to
secure wiring.
5. Plug the power supply i
nto
an un
-switched outlet and secure with
screw.
6. Attac
h the backup battery wires.
AC
POWER
The repeater is powered by a 5VD
C, 1 Amp Plu
g-in Power Su
pply
(Part #
: 300
-10342).
Refer to the wiring table below for w
ire ga
uge
and length:
Wire Gauge
Wire Length
#
22
Up to 20 feet (6m)
#20
Up to 33 feet (10m)
#18
Up to 50 feet (15m)
Use only the 300
-10259
Power Supply. Plug
the
battery
prior to providing
power
from A
C Outl
et.
NOTE
:
For Indoor Use Only.
ENRO
LLING
You must enroll
the device in the
control
. The repeater
enrolls as a se
nsor but
, does
not
require a
"Device" or
"Response
" typ
e. To enroll:
Put
the cont
rol in Se
nsor Lear
n Mode and plug
the
PROSiXRPTR in
, it automaticall
y attempts to
enroll upon pow
er up
. If it t imes out
, press and
release the t
am
per to reini
tiate the enrollment process
or remove and reconne
ct AC powe
r.
NOTE
S:
•
Refer to the LED S
tatus
Table for the
operation of the LED's during enrollment.
•
Once enrolled in a system, the
PROSiXRPTR
can
not be used with another controller u
ntil it is removed from the cur
rent controller. See
the
Controller’s in
structions
for details.
•
Enrollment time varies de
pending on
the signal streng
th between the device and the controller. When done,
Power LED
is ON fo
r 3
seconds and the cont
rol
ler
beeps
to confirm enrollment
. Keep n
ear the control until all three LED's are solid green.
•
The
PROSiXRPTR
should be installed
before any ot
her sensors
.
NOTE:
Must
be installed in accordance with
the
Nati
onal Electrical Code,
ANSI/NFPA 70
LED STATUS
TABLE
R
SSI
Power
RF Jamming
Green
Reli
able Signal
AC
/B
attery OK
OK, No Jamming
Amber
Margi
nal Signal, relocate
No Battery or Low
Battery
N/A
Red
No Signal
(Slow Bl
inking)
N
o AC, Running on Battery (See
note
3
,4
)
RF
J
am Det
ect
ed
Enrolling
(Green LED’s
Only)
(Note
1
)
Scro
ll
ing
Scrolling
Scrolling
Enrol
lm
ent Successful (
Amber
LED’s Only
)
S
crolling
Scrolling
Scrolling
Enrollme
n
t Time Out
(
Red LED’s
Only)
(Note 2
)
Rapid Blink
Rapid Blink
Rapid Blink
Normal
D
e
lete (Green LED
’s
Only)
Rap
id Blink
Rapi
d Blink
Rap
id Blink
Self
-
Delete
(Green LED’s Only)
Rapid Blink
Rapid Blink
Rapi
d Blink
Programming
LED OFF
X (Green
, Red
, or Amber)
L
ED OFF
NOTES:
1.
Cycle for scrolling Enrollment L
ED is 2 sec ON
/ 4 sec
Off.
2.
Blinking will co
ntinue for 5
seconds and then ALL LED's w
ill go BLANK.
3.
RE
D LED should be slow
blinking (O
N for 0
.5seconds
; OFF for
3 seconds)
4.
The RSSI and RF Jammin
g
LE
D
’
s will be o
ff.
INSTALLING
THE PROSIXRPTR
1.
Using the “
Com
pati
bility
Secti
on”
above conf
irm
the controller and sensors are at the correct r
evis
ion le
vel to support the PROSiXRP
TR
.
2.
Enroll the PRO
SiXRPTR
by keeping
near the
contr
oller
until all
three LED
’s are solid
Green. The PROSiXRPTR
shoul
d be enrolled as a
sensor
from
AN
360
or the control
.
3.
With battery power applied and the Repeater co
ver removed, move
the
PROSiXRPTR
away from the control
in the direction i
n which
the
sensor(s)
are not comm
unicating wit
h the
control
.
4.
The
PROSiXRPTR
verifies
the signal strength between the control
and
PROS
iXRPT
R every
fiv e seconds
. T
he RSS
I LED will c
hange from
Green
to
Amber
(Green means you
are within range)
after 30 seconds
. Amber
LE
D tel ls you this is the furthe
st fro
m the
control
you can mount the
PROSiXRPTR
. Red L
ED in
dicates
the
repeater is out of r
ange with the control panel.
5.
Perform
an “Add Se
nsor
” command
fro
m AN3
60
(a sensor do
es not have to
be added at thi
s time, just cancel the command)
. Doing this
forces the
Control
to request
signal st
rength from all sensors.
Once
a sensor has
joined the PRO
SiXRPTR the sig
nal strength should be
at least
2 bars.
6.
AN360
or the
Control
can
indicate
which the sensor is con
nected
(Either the control, repe
ater 1 or repeater 2)
. On the control
, go to
sensors
to determine which it is connected to.
If sensor signal s
trength is too weak
(less then two ba
rs) then
the contro
l can send a
“Rescan
Repeat
er” command
. This is done through AN360
(Diagno
stics Page) or the control
's Installer/Master Tools screen.
7.
Perf
orm a Sensor Walk Test to verif
y sensor
s are c
ommunicating thr
ough the PROSiXRPTR
or
direc
tly to the controller
.
NOTE
: Mak
e sure all door
s/wind
ows are c
losed bef
ore entering
Walk
Test.
24-
HOUR ENROLLMENT DELETION AND DEFAULT
If the device
is enrolled
in a
control
ler different
than the intende
d cont
rol
ler , and you
are unable to delete it from the unint
ende
d controller
,
de
fault
the device to factory default setting:
1. Open
the cover and verify device is powered on.
2. Press
the tamper for ½
second
, release for
½ second
and repeat fo
ur more times. (
for a
total of
five
).
3. All three LED
’s rapidly flash
and the P
RO
SiXRPTR
defaults,
leaving only the Power
LED on
.
This procedure is available
for 24 hours after enrollment with a panel and the device rem
ains
powered
(battery installed).
NOTE:
if all LED’s light sol
id red f
or 5
-seconds, then you are passed the 24
-hour
wind
ow.
TAMPER/LOW BATTERY REPO
RTING
Th
e PRO
SiXRPTR
reports this c
ondition t
o the
Con
trol
. If a low battery or tamper condition exists
, a Zone XX Repeater T
rouble
or Low
Battery
displays
on
the
Control
.
NOTE
: If an
actual l
ow battery c
ondition is reported, it t
akes up
to 12 hours aft
er AC power is rest
ored for the low battery restore message to be
sent (requires 12 hours for fully recharged battery).
IMPORTANT
!
For the first hour after power up the batt
ery is tested e
very minut
e. After the first hour of power up the battery is tested every 12 hours.
To
quickl
y verify a good backup battery, unplug
and
then plug back i
n the power
supply;
the system will
perform a battery test within one
minu
te.
SUPERVISI
ON
The
PRO
SiXRPT
R reports AC loss and R
F jam conditions
, which
displays
a trouble on the
Control
’s keypad
(s). This prevents either condit
ion
from causi
ng an alarm when the
Co
ntrol
is armed.
NOTE:
RF Jam i
s an optional feature and is enabled
by default
. It must remain
enabled in
programming
for a
n RF Jam condition to be
indicated.
REPLACING THE BATTERY
SPECIF
ICATIONS
Voltage
Transformer Part Number
.......................................................................................................................................................................
300
-1025
9
Input Voltage
..................................................................................................................................................................
100 ~ 240VAC, 50 ~60 Hz
Operating Vol
tage
..................................................................................................................................................................................
5VDC (1A)
Maxi
mu
m T
ransformer Distance
.......................................................................................................................................See
Power Suppl
y Table
Batter
y ....................................................................................................................................................................................................
300
-10342
Environmental
Ope
rating Tem
p .........................................................................................................................................................
32
F (
0
C) to 140
F (60
C)
NOTE:
Char
ging the lithium battery stops when temperatur
e is below
32
F (0
C)
Relative Humidity
.................................................................................................................
95%, Non-
condensing /
95%max.
sans c
ondensation
Physical
Dimen
sions
..............................................................................................
Length
6.9 in (175mm
) /
Width
4.4
in (11
3 mm)
/
De
pth
1.2 in
(31
mm)
Acceptable Cable Size
........................................................................................................................................................................
18 – 22AWG
T
EST SYSTEM WEEKL
Y
NOTE:
System
must also be
test
ed with AC
power
removed.
REFER TO TH
E INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH
T
HIS DEVICE IS
USE
D,
FOR DETAILS
RE
GARDING LIM
ITATI
ONS OF THE ENTIRE ALARM SYSTEM.
RF EXPOSU
RE
War
ning – Th
e ant
enna(s)
used for this device must be installed to provide a separation distance of
at least 7.8 inches (20 cm) from all persons and
must
not be co-
locat
ed or o
perating in con
junct
ion w
ith any other antenna or tr
ansmitter except in ac
cordance
with FCC
and
ISED mult
i-transmitter
product procedures.
APPROVAL LISTINGS / APPROBATIONS HOMO
LOGATIONS
UL 985
:
2015 Ed
.
6+
R:12Jul2018
UL
1023:
2017 Ed.
7
UL 1610:2016
Ed.4
UL 1637:2017 Ed
.5
UL 2017:
2008
Ed.
2 +R
:17Jan2016
ULC
S304:2016 Ed.
3 +R
:10O
c
t2018
ULC S5
45:2002 Ed.2
ULC SUBJECT C1023:1974 Ed.1
CSA C22.2
#205:2017 Ed.3
OTHER STANDARDS
RoHS
System
shall
be installed in accordance with CAN/ULC
-
S540
, Residential F
i
re Warning Systems.
System shal
l be installed in accordance with Chapter 29 of t
he National Fi
re Alarm and Signalling Code, ANSI/NFPA 72.
System shall be install
ed in accordance with CSA C22.1
,
Canadian Electrical Code, Part I, Safety Stand
ard for Electri
cal Installations ; C
AN/ULC
S302, Standard for the Installation, Inspection and T
esting of In
trusion Alarm Syste
ms; and CAN/U
LC S301, Standard for Signal Receiving Centre
Intrusion Alarm Systems and Operations
.
FEDERAL COMMUNICATIONS
COM
MISSION (FCC) &
INDUSTRY CA
NA
DA (IC)
STA
T
EMENTS
The user shall not make any changes or modificat
ions to the
equipment unless
authorized by the Installation Instructions or User's M
anual.
Unauthoriz
ed
changes or modificat
ions could void the user's authority
to operate the
equipment.
CL
ASS B DI
GIT
AL DEVI
CE STATEMENT
This
equipment has been tested and f
ound to comply
with the limi
ts for a Class B digital device, as defined by FCC Rules
Part 15.105. The
Class B
Digital Device
statement can be viewed at:
https://custo
mer
.resideo.com/en-
US/support/residential/codes
-and-
standards/FCC15105/Pages
/default.aspx
FCC /
IC STATEMENT
This device compli
es w
ith Part 15 of t
he FCC Rule
s, and Ind
ust
ry Cana
da’s license-
exem
pt RSSs. Operation is subject to
the followi
ng
two
condition
s: (1) This device may not cause harmful interference, and (2) This devic
e m
ust accept any inter
ference received, including interfer
ence
that may c
ause undesir
ed
operat
ion.
Cet appareil est confor
me à la partie 15 des règles de la FCC et ex
em
pt de licence RSS
d’Industrie Canada. Son fonctionnement est soumis aux
conditions suiv
ant
es: (1) Cet appareil
ne doit pas causer d’interféren
ces
nuisibles. (2) C
et appareil
doit acc
epte
r toute
interférence reç
ue y compris
les interférences c
ausant une r
éception indésir
abl
e.
Responsible Party / Issuer of Supplier’s Declar
ation of Conformi
ty: Ademco Inc., a subs
idiary of Resideo Technologies, Inc.
, 2 Corporate C
enter
Drive.
, Melvill
e, N
Y 11747, Ph: 516
-577-
2000
The product should not be dis
posed of wit
h other househol
d w
aste. Check for the neares
t authorized collection cen
ters or authorized r
ecyclers. The
correc
t disposal of end-
of-life equipm
ent
will help preven
t potential
negative
con
sequenc
es for the environment and human health.
Any atte
mpt to rever
se -engineer this
device by decoding proprietary protocols, de-
compiling
firmware, or any sim
ilar actions is strictly prohibited.
SUPPORT & WARRANTY
INFORMATION
Fo
r the latest
document
atio n and
support, please go
to:
www.resideo.com
For the latest warranty information, please go to:
www.security.
honeywellhome.com/w
arranty
www.resideo.com
Resideo Technolo
gies, Inc
2 Corporat
e Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
© 202
1
Res
id
eo Technologies, Inc. All rights reserved.
The Honeywell Home trademark is used under license from Honeywell
International, Inc.
This product is manufactured by
Resideo Technologies
, Inc. and its affiliates.
Ê800
-24399DQŠ
800
-
2
43
99
D
4
/20
Rev
D
- Uploaded