Honeywell Home PROSIXSHOCK Installation Instructions - Dated 2/19 Rev. B



Related Products

Honeywell Home PROSIXSHOCK - Encrypted Wireless Shock, Door/Window, & Transmitter Sensor
Honeywell Home PROSIXSHOCK
Encrypted Wireless Shock, Door/Window, & Transmitter Sensor
List Price: $68.00
Our Price: $49.99

Document Transcript




PROSiXSHOCK

Wireless
Shock/
Door/Window Sensor

Installation
and Se
tup
Guide


The
PROSiXSHOCK

is a 3
-
zone
wireless
shock/door/window sensor
is intended for use with
Honeywell
Home
controls that support
PRO
SiX™ series
devices.

It provides


Reed switch/m
agnet
zone


External wired contact zone


Built
-in shock sensor zone
(designed to protect windows
and doors)


Typical shock protection area:

10
- 12 ft.
diameter
/ 5 -
6 foot radius (3.05m –
3.66m

diameter
/ 1.52m –
1.83m radius)
The coverage area can v
ary
de
pending on the mounting
surface.



INSTALLATION OPTIONS

The
PROSiXSHOCK
can be installed
with several options:

• Loop 1: Normally closed, built
-in reed switch, used with
the included magnet

• Loop 2: Externally wired, closed-
circuit contact loop
connect
ed to the Terminal Block (unsupervised)

NOTE:
Wiring limit is 3ft.

• Loop
3: Built
-in shock sensor
. Red LED flashes briefly
upon sensing shock


Magnet
Gap specifications
:

a. Make gap is at least 0.8"
b. Break gap is at least 0.95"

(reduced about 3
0%
for steel)




MOUNT THE PROSIXSHOCK
1. To open the device,
firmly slide the front
and
back

housings in opposite directions and pull them apart.

2. The
PROSiXSHOCK
sensor MUST be mounted as
follows:


• On swinging doors: mount on upper corner
of door
(not door frame)
; opposite hinge is ideal


• On sliding windows and doors: on the frame


(on moving section when magnet is used)

3. Mount sensor as shown,
using
the
double-
sided
tape
and screws provided.

4. Secure the front cover with the #2
x 1/4” scr
ew.

After enrolling
and before mounting, verify adequate signal
strength by conducting a sensor test
(see controller’s
instructions) with the device in its intended mounting
location. Adjust the device location and orientation as
necessary.




ENROLL
AND SET UP

You must enroll the device in the control. Refer to the
control
's programming instruction for detailed procedures.

Set
the
controller
in Programming Mode
and when
prompted:

1. Pull
the
battery tab
to activate the
PROSiXSHOCK.
(Use
the magnet if t
he
battery tab is removed.)

2. The LED flashes (
up to about 20 seconds*) during
enrollment.


All services
(Reed,
Terminal Block
, and Shock
) are
enrolled in
sequential (or next available) zone numbers.


The device sends its unique MAC ID (Serial Number);
the con
tro
ller registers the device and
displays the
transmitter data on screen.

*NOTE
: Enrollment time varies depending on the signal
strength between the device and the controller.

3. When
done,
the LED is ON for 3 seconds to
confirm

enrollment.

NOTE
: If the devi
ce
is not successfully enrolled during
the enrollment period, the LED turns off and the device
powers down. Activate a tamper, wired service (loop) or
the reed switch to restart the enrollment process.

4. Program each zone being used:

Reed Switch
Zone

(loop 1)

Terminal B
lock Zone
(loop 2)

Shock Zone
(loop 3)

After enrolling, verify adequate signal strength by
conducting
a sensor test
(see controller’s instructions) with
the device in its intended mounting location. Adjust the
device location and orientation as
necessary.



IMPORTANT
: Once enrolled in a system, the
PROSiXSHOCK
cannot
be used with another controller
until it is removed from the current controller. See the
Controller’s instructions for details.

DEMO MODE (NO ENROLLMENT NEEDED)


1.

Remove the bat
te
r
y pull tab from the device.

2. Install the mounting
plate onto the back cover to insure both tampers are closed.

3. The device will attempt to pair with a control (Flashing green LED for ~
20 seconds, which is
visible through the top
cove
r)
4. The Green LED will tu
rn off and
within a minute
the
device
is default
ed to maximum shock sensitivity for 10
minutes
.
5. Strike the device in the palm of your hand, the red LED will flash through the front cover indicating a shock event.

6. When ready to learn
the device into a contr
ol open/close the cover again or trip the reed sw
itch using a magnet.
The pairing time window will start again.

SENSITIVITY ADJUSTMENT

NOTE:

The
PROSiXSHOCK
sensitivity must be set after
mounting and enrollment.
See the Controll
er’s instructions
for
det
ails
.

The
PROSiXSHOCK
has the f
ollowing sensiti
vity settings:


Maximum
– Medium
– Low
- Lowest

1. Verify the sensitivity setting is adequate by striking the
protected surface with
the soft part of your fist
at the point
farthest f
rom the device.

2. If sensitivity is ade
quat
e the red LED flashes briefly

(remove cover for easier viewing of LED)
.

If the LED
does
not
flash
, select the next higher
sensitivity setting and repeat from step 1
.



24
-HOUR ENROLLMENT DELETION AND DEFAULT

If the device is enrol
led in a panel different than the intended
panel, and you are unable to delete it from the unintended
panel,
reset
the device
to factory default setting:

1. Open the cover and remove the battery.

2. Hold down the tamper switch while reinser
ting the
battery.
Rapi
d LED flashing indicates successful deletion
(LED f
lashes as if in enrollment mode). If LED does not
flash, delete was not successful.

3. Reattach the cover.


This procedure is available for 24 hours after enrollment with
a panel and the

device remains powere
d
(
battery installed).


LED INDICATIONS


LED

St
atus

Rapid Flashes for about 20
seconds, then ON for 3 seconds

Power Up


Enrollment

Slow Flashes

Power Up


Device enrolled; Wall or Cover Tamper activated. To stop flashes, clear
the
tamper condition by re
connecting to the mounting plate and reattaching the cover. It also
times out after 10 minutes.

ON (while in Programming Mode)

Sensor LED toggles on and off when the sensor is selected. See Sensor Location Feature.


BATTERY REPLACEMENT


Push the bottom
latch of the mounting
bracket back to disengage
it. Then
slide the
back housing up and out to remove
it from
the
mounting
bracket
.


Slide the front and back housings in opposite
directions
and pull
the housings apart
.

Re
move
the
battery
,
wait
10 seconds
,
then
insert a new battery
.
Recommended batteri
es:

Duracell DL123A
, Huiderui CR123A
,
Panasonic CR123A
, Resideo 466


Place the front and back housings together
and slide them together.

BATTERY CAUTION
: Risk of fire, explosion
and burns.
Do not
recharge,
disassemble, heat
above 212°
F (100
°C)
or inciner
ate. Dispose of
used batteries proper
ly. Keep away from
children.

NOTE
: Constant exposure to high or low
temperature or high humidity may reduce
battery life.















SPECIFICATIONS:

Battery:
1 x 3V
Lithium,
Res
ideo 466,
Panasonic CR123A
, Duracell DL123A or

Huiderui
CR123A

Tamper:
Cover and Wall

RF Frequency
:
2.4GHz

Operating Temperature
: 32°
– 122° F / 0°
– 50° C

(Agency Compliance 32°
– 120° F / 0°
– 49° C)

Relative Humidity:
95% max. (Agen
cy Compliance
- 93% max.),
non-
condensing

Dimensions:
1” H x 3.13”
L x 1.61” W / 25.5 mm H x 79.5 mm L x 41 mm W


APPROVAL LISTINGS:

FCC / IC

cETLus Listed

Conforms to UL 634

Certified to ULC/ORD
-C634
, ULC
S306

Other Standards:

RoHS


Product must
be tested
at

least once each year

FEDERAL COMMUNICATIONS COMMISSION (FCC) & INDUSTRY CANADA (IC) STATEMENTS

The user shall not make any changes or modifications to the equipment unless authorized by the Installation Instructions or U
ser's Manual.
Unauth
orized changes or modifications could void the user's authority to operate
the equipment.

CLASS B DIGITAL DEVICE STATEMENT

This equipment has been tested and found to comply with the limits for a Class B digital device, as defined by FCC Rules Part
15.105.
The Class B
Digital Device statement can be viewed at:

https://customer.resideo.com/en-
US/support/residential/codes
-and-
standards/FCC15105/Pages/default.aspx

FCC / IC STATEMENT

This device complies with Part 15
of the FCC Rules, and Industry Canada’s license-
exempt RSSs. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) This
device must accept any interference received, including interference
that m
ay cause undesired operation.

Cet appareil est conforme à la partie 15 des règles de la FCC et exempt de licence RSS d’Industrie Canada. Son fonctionnement
est soumis aux
condition
s suivantes: (1) Cet appareil ne doit pas causer d’interférences nuisibles. (2) Cet appareil doit accepter toute interférence reçue y compris
les interférences causant une réception indésirable.

RF EXPOSURE

Warning
– The antenna(s) used for this device mus
t be installed to provide a separation distance of at least 7.8 inches (20 cm) from all persons
and must not be co-
loc
ated
or operating in conjuncti
on with any other antenna or t
ransmitter except in accordance with FCC and ISED multi
-
transmitter product pr
ocedures.

Mise en Garde

Exposition aux Fréquences

Radio
:
La/les antenne(s) utilisée(s) pour cet émetteur doit/doivent
être
installée(s) à une distance de séparation d'au
moins 2
0 cm (7,8 pouces) de toute personne et ne pas être située(s) ni fonctionner para
llèlement à tout autre transmetteur ou antenne, excepté en
conformité avec les procédures de produit multi transmett
eur F
CC et ISED.


REFER TO THE INSTALLATION INSTRUCTIONS FOR THE CONTROL WITH WHICH T
HIS DEVICE IS USED, FOR DETAILS
REGARDING LI
MITAT
IONS
OF THE ENTIRE ALARM SYSTEM.



Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary of Resideo Technologies, Inc., 2 Corporate Center
Drive., Melville, NY 11747, Ph: 516-
577-
2000


The product should not be disposed of
with other household waste. Check for the nearest authorized collection centers or authorized recyclers. The
correct disposal of end-
of-life equipment will help prevent potential negative consequences for the environment and human health.

Any attempt to
reverse-
engineer this device by decoding proprietary protocols, de-
compiling firmware, or any similar actions is strictly prohibited.


SUPPOR
T & WARRANTY INFORMATION

For the latest documentation
and
support, please go to:

www.resideo.com


For the latest warranty information, please go to:

www.security.honeywellhome.com/warranty


The Honeywell Home Tradema
rk is used under license
from
Honeywell Internatio
nal Inc.

This product is manufactured by Resideo
Technol
og
ies, Inc.
and its affilates.


2 Corporate Center Drive, Suite 100
P.O.
Box 9040, Melville, NY 11747
©
2020
Resideo Technologies, Inc.

www.resideo.com

Ê800 -25219BcŠ

PRO
SiXSHOCK
800
-25219
B 2/19
Rev B