Honeywell L5000 Quick Install Guide

LYNX Touch Series Control
Quick Installation Guide
This Quick Installation Guide can help you install
the rechargeable LYNX Touch Series Control quickly
and easily by providing the basic steps for install
ation using the built-in defaults.
FOR DOCUMENTATION AND ONLINE SUPPORT:
http://www.security.honeywell.com/hsc/resources/MyW
ebTech
(see LYNX Touch Series Installation and Setup
Guide P/N 800-06834 or higher.) A copy of the Insta
llation and setup Guide may also be requested from
Honeywell.
WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa
1. Install the Control
TERMINAL
STRIP
POWER
SUPPLY
RECEPTACLE
BACK
CASE
TAMPER
SWITCH
TELEPHONE
CONNECTIONS
GSMVLP5/ILP5
RECEPTACLE
WIRE ROUTING
CLIPS (3)
MOUNTING
HOOKS
(HINGES)
5000-100-050-V1
LOCKING TABS
FRONT
CASE
ROTATE
FRONT CASE
UPWARD
TO RELEASE
HOOKS
ILP5
RECEPTACLE
KNOCKOUT
ILP5
SPACER
BATTERY
CABLE
CHANNEL
TIE WRAP
POINTS (3)
MOUNTING
HOLES (4)
TIE WRAP
POINTS (2)
2. Make Wiring Connections
5000-100-172-V0
2K
OHM
EOLR
POWER SUPPLY
CONNECTOR
HARD
WIRED
ZONE
WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM
PREMISES
TELEPHONE
INCOMING
PHONE LINE
INCOMING
PHONE
LINE
H/S T
H/S R
RING
TIP
EGND
EARTH
GROUND
HWZ1
TRIG
GND
GND
+9VDC
300-04705 or 300-04605
(300-04063 CANADA)
POWER SUPPLY
9V, 2.7A
STANDARD/HIGH CAPACITY
BATTERY CONNECTORS
SUPER HIGH CAPACITY
BATTERY CONNECTOR
ZONES
POWER
PHONE
TRIGGER OUTPUT (NEG)
(3ma)
RING
TIP RING TIP
TELCO
JACK
UL NOTE
THE MINIMUM WIRE SIZE USED FOR TELEPHONE
INSTALLATIONS MUST BE #26 GAGE
OBSERVE POLARITY WHEN
CONNECTING THE POWER
SUPPLY TO THE TERMINAL STRIP.
WARNING
TO PREVENT
RISK OF SHOCK,
DISCONNECT
TELEPHONE LINE
AT TELECOM
JACK BEFORE
SERVICING
THIS UNIT
NOTE
USE ONLY THE
300-04705/300-04605
OR 300-04063
POWER SUPPLY
PROVIDED
ALL OUTPUT CIRCUITS ARE POWER LIMITED.
GSMVLP5/ILP5
RECEPTACLE
Note:
For the complete Summary of Connections, refer to t
he LYNX
Touch Series Installation and Setup Guide P/N 800-0
6834 or
higher.
3. Install the Communications Module
SIM CARD
5000-100-173-V0
ROTATED
180
ROTATED
180
CONNECTOR
BOARD
CONNECTOR BOARD
CONNECTOR BOARD
RECEPTACLE
LYNX TOUCH
TIE
WRAP
POINT
NOTE:
SIM CARD INSTALLED
IN GSMVLP5 ONLY
REMOVE
ILP5
SPACER
ILP5
SPACER
REMOVE
ILP5
KNOCKOUT
TIE
WRAP
(1)
LYNX TOUCH
ALTERNATE INSTALLATION
RJ45
RECEPTACLE
RJ45 RECEPTACLE
ETHERNET CABLE
GSMVLP5
SCREW
(3)
ILP5
TO ILP5
Ensure that SIM card and the connector board are se
curely
installed in the communications module before installi
ng it
in the LYNX Touch.
4. Make Battery Connections
5000-100-018-V1
LYNXRCHKIT-SHA
(P/N 300-03866)
OR
RETAINER
SCREW
RETAINER
LYNXRCHKIT-SC
(P/N 300-03864-1)
SCREW
1. Release the front case from the rear case by de
pressing the two
locking tabs at the top of the unit with the blade
of a medium size
screwdriver.
2. Separate the front and back case assemblies by r
otating the front
case so that it is perpendicular to the rear case a
nd unsnapping
(releasing) the two hooks (hinges) from the back ca
se.
3. Feed the wiring through the appropriate openings
in the back
case. Use tie wraps to secure the wiring to the bui
lt-in wire loops
as needed.
4. Mount the back case to a sturdy wall and secure
with the provided
screws.
5. Attach the front and back cases by connecting th
e hooks on the
front case to the attachments on back case. Once at
tached, the
hooks will support the front case and allow you to
make the wiring
connections.
6. After all of the wiring connections have been ma
de, snap the front
case and back case closed and ensure that the locki
ng tabs
secure the case.
1. Make earth ground connections to EGND terminal.
2. Connect the incoming phone line to either the 8-
position jack or
the TIP and RING terminals.
3. Connect the handset phone lines to the H/S T (TI
P) and H/S R
(RING) terminals.
Note:
For full line seize operation, refer to the LYNX To
uch Series
Installation and Setup Guide.
4 Connect the sensors/contacts to the HWZ1 (+) and
GND (-)
terminals.
5. If used, install the GSMVLP5 or ILP5 communicati
ons module
Refer to the Install the Communications Module sect
ion or to the
Installation Guide for the Communications Module (P
/N 800-
01115 or higher).
6. Connect wires from the 300-04705/300-04605 OR 30
0-04063
(Canada) Power Supply to GND (-) and +9VDC (+) term
inals OR
plug the Power Supply connector into the receptacle
on the LYNX
Touch.
1. If you are installing the ILP5 module, use a wir
e cutter or knife to cut
the plastic tabs that secure the ILP5 spacer to the
back case of the
LYNX Touch. If you are installing the GSMVLP5 modul
e, proceed to
step 3.
2. Remove the ILP5 receptacle knockout from the lef
t side of the
LYNX Touch back case
3 Install the Communications Module into the front
case. Ensure that
the connector board is properly seated into the rec
eptacle on the
control.
4 Secure the module with the three provided screws.
If you are
installing the ILP5 module, proceed to step 5. If y
ou are installing
the GSMVLP5 module, proceed to step 8
5. Insert the ILP5 receptacle and spacer into the s
lot on the back
case.
6. Secure the communications cable to the tie wrap
point on the ILP5
with the provided tie wrap.
7. Connect the Ethernet cable to the RJ45 receptacl
e.
8. Enable the module, configure alarm reporting and
module
supervision and register the device. Refer to the “
Program the
Radio” and “Diagnostics” sections of the LYNX Touch
Installation
Guide (P/N 800-06834 or higher).
1. Remove screw securing the battery retainer.
2. Remove the battery retainer.
3. Insert battery pack into back case.
4. Install battery retainer.
5. Install screw to secure the battery retainer.
6. Connect battery connector to receptacle on PC bo
ard.
7. After all wiring connections have been made, sna
p the front case
to the back case so it is held by the locking tabs.
8. Plug the Power Supply into a 24-hour, 110VAC uns
witched outlet.
Note:
Rechargeable batteries may take up to 48-hours to
fully
charge. “Battery Low” message should clear within f
our hours,
or by entering Test Mode.
Battery
Pa
rt Number
Battery Standby
Time (Minimum)
Low Battery Notification
LYNXRCHKIT-SC
(300-03864-1)
4-hours
Approx. 1-hour before
battery depletion
LYNXRCHKIT-SHA
(300-03866)
24-hours
At least 1-hour before
battery depletion
Ê800-06896(Š
800-06896 3/11 Rev. A
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2011 Honeywell International Inc.
www.honeywell.com/security
Programming Notes
Entering Installer Programming mode
1. Power-up the control and select the “more” tab o
n the first
page of the Home Screen.
2. Select “Tools” button.
3. Enter the 4-digit Installer Code (4-1-1-2).
4. Select “Program” button.
5. The System Programming Screen will appear and th
e
“ARMED” and “READY” LEDs will flash.
Exiting Programming mode
1. Once programming is completed, at the System Pro
gramming
screen, select the “

” button.
2. Select the “Yes” when the system prompts “Allow
Installer to
Re-Enter Programming?”.
3. Select the “

” button to return to the Home Screen.
Entering Master User Programming mode
1. Power-up the control and select the “more” tab o
n the first
page of the Home Screen.
2. Select “Tools” button.
3. Enter the 4-digit Master User Code (1-2-3-4).
4. The Master User Programming Screen will appear a
nd the
“READY” LED will remain lit.
5. Select the applicable programming function from
the Master
User screen.
Exiting Programming mode
1. Once programming is completed, select the “back”
tab
to
return to the Home Screen.
OR
2. Depress the “Off” key and then select the ‘Cance
l” button.
3. The system will return to the Home Screen.
5. Program the Control
Change the Installer Code
The factory default Installer Code for the LYNX Tou
ch Series Control
is set to 4-1-1-2. To change this code, you must en
ter Programming
mode.
1. Select “Program” button.
2. Select “Installer Code” button.
3. Enter a new 4-digit Installer Code.
4. Select “Done” button
Program Date
Note:
If you are installing a GSMVLP5 or ILP5 Communica
tion
Module, the time and date will be programmed and up
dated
automatically via Central Station. You must still p
rogram the
correct Time Zone
To change this code, you must enter Programming mod
e.
1. Select “Program” button.
2. Select “Date Time” button.
3. Enter the date, time and time zone as required.
4. Select “Save” button.
Program Defaults
LYNX Touch is pre-programmed at the factory with a
built-in set of
default values. Refer to the Programming Default Ta
bles section of
the LYNX Touch Series Installation and Setup Guide
(P/N 800-06834
or higher) to view the Default Tables. To select fa
ctory defaults from
a set of four tables, you must enter Programming mo
de.
1. Select “Program” button.
2. Select “Default Config.” button.
3. Select the desired Default Table.
4. Select “Yes” when the confirmation screen appear
s.
6. Add Wireless Sensors
Add a Sensor
To add, edit or delete Wireless Sensors you must en
ter Programming
Mode.
1. Select “Zones” button.
2. Select “’Add new” button.
3. Select the applicable Zone button.
4. Select “Serial Number” Button
5. Enter Serial Number or
Enroll via RF Learning.
To enroll the
transmitter, three (open/close) transmissions of th
e device will be
required.
6. If desired, program the following options:
Loop Number
Zone Description 1 and 2
Device Type
Response Type
Alarm Report
Chime
Supervision
7. Select “Save”.
Edit Wireless Sensor/Zone information
1. Select “Zones” button.
2. Select the Zone you wish to edit and then select
the “Edit” button.
3. Edit the applicable zone programming fields as r
equired.
4. Select “Save”.
Delete a Wireless Sensor
1. Select “Zones” button.
2. Select the Zone you wish to delete then select t
he “Delete” button.
3. Select the “Yes” button when the confirmation sc
reen appears.
6. Add Wireless Keys
To add, edit or delete a Wireless Key you must ente
r Programming
Mode.
Add a Wireless Key
1. Select “Keys” button.
2. Select ’Add New” button.
3. Select the “Key Type” button and scroll through
the available key
types.
4. Select “Serial Number” Button
5. Enter Serial Number or
Enroll via RF Learning.
To enroll the
transmitter, three (open/close) transmissions of th
e device will be
required.
6. Select the “User” button and then select the Use
r that will be
associated with the key that is being enrolled.
Note:
In order for the Key to function, a valid User Co
de must be
associated with the User that has been assigned to
the key.
7. If desired, program the following options:
Zone
Button Key * - Zn **
8. Select “Save”.
* Button number is determined by the type of key be
ing enrolled.
** Zn No. based on the type of key being enrolled.
Edit Wireless Key information
1. Select “Keys” button.
2. Select the Key you wish to edit and then select
the “Edit” button.
3. Edit the applicable fields as required
4. Select “Save”.
Delete a Wireless Key
1. Select “Keys” button.
2. Select the Key you wish to delete then select th
e “Delete” button.
3. Select the “Yes” button when the confirmation sc
reen appears.
7. Add Central Station Accounts
To add Central Station Account information, you mus
t enter
Programming Mode.
Add First or Second Central Station Information
1. Select the “Reporter” button.
2. Select the “Primary Central Station” or “Seconda
ry Central
Station” button.
3. Program the following fields as applicable:
Phone Type
Phone Number
Communicator Type
Account Number
Dynamic Priority
Dynamic Delay
Report All
Report Alarms
Report Troubles
Report Open/Close
Report Tests
4. Select the “Save” button when programming is com
plete.
!
All four digits of the Central Station
Account numbers must be
entered. For ten-
digit format, all ten digits must be entered.
Refer to the Lynx Plus Series Installation and Setu
p Guide for
additional information regarding these programming
options.
8. Register the Communications Module
The Communications Module can be registered either
via the
Alarmnet Direct Website, by Phone or through the LY
NX Touch
Diagnostics. For additional information on the firs
t two methods refer
to the LYNX Touch Installation and Setup Guide P/N
800-06834 or
higher.
Register through LYNX Touch Diagnostics
To Register the Communications Module, you must ent
er
Programming Mode.
1. Select the “Comm./ Diagnostics” button.
2. Select the “Setup Communications” button.
3. Select the “Register Device” button. The registr
ation message is
sent and the unit waits for the acknowledgement. (R
efer to the
LYNX Touch Installation and Setup Guide P/N 800-068
34 or
higher for additional information)
9. Program User Functions
To perform these functions, you must enter the Mast
er User
Programming mode.
Add Users
1. Select the “Users” button.
2. Select the “Add New”
button.
3. Enter a User Name.
4. Enter a 4-digit User Code.
5. Select “Done”.
Change the Master User Code
1. Select the “Users” button.
2. Select the “Master” button.
3. Select the “Edit”
button.
4. Enter a new 4-digit User Code.
5. Select “Done”.
Change/Edit Users or User Codes
1. Select the “Users” button.
2. Select the applicable “User” button.
3. Select the “Edit”
button.
4 Revise the User name, if applicable, then select
the “Done”
button.
5. Enter a new 4-digit User Code, if applicable, th
en select the “Done”
button.
Delete User Codes
1. Select the “Users” button.
2. Select the applicable “User” button.
3. Select the “Delete”
button.
4. Enter a new 4-digit User Code.
5. Select “Yes” when the confirmation screen appear
s.
10. Test the system
To perform this function, you must enter the Instal
ler OR
Master User Programming mode.
1. Select the “Test” button or icon.
2. Select the “Walk Test” button or icon.
3. Open each protected door and listen for three be
eps from the
keypad, followed by the zone’s Voice Descriptor. Id
entification of
each faulted protection point should appear on the
display, and
clear when the door is closed.
4.
Walk in front of the motion sensor and listen for t
hree beeps and
the zone’s voice descriptor.
5. When testing is complete, enter an OFF sequence.
6. Press each key on the key fob to confirm it perf
orms its assigned
function.
Note:
Refer to the Lynx Touch Series User Guide P/N 800-
06894 or
higher for additional information.
of 2


Related Products

Honeywell L5000 LYNX Touch Wireless Alarm Control Panel high resolution close-up
Honeywell L5000
LYNX Touch Wireless Alarm Control Panel
Honeywell L5000-SIA - LYNX Touch Wireless Alarm Control Panel
Honeywell L5000-SIA
LYNX Touch Wireless Alarm Control Panel

Related Categories


Document Transcript

LYNX Touch Series Control
Quick Installation Guide
This Quick Installation Guide can help you install the rechargeable LYNX Touch Series Control quickly and easily by providing the basic steps for installation using the built-in defaults.

FOR DOCUMENTATION AND ONLINE SUPPORT: http://www.security.honeywell.com/hsc/resources/MyWebTech (see LYNX Touch Series Installation and Setup Guide P/N 800-06834 or higher.) A copy of the Installation and setup Guide may also be requested from Honeywell.

WARRANTY INFORMATION
For the latest warranty information, please go to:
www.honeywell.com/security/hsc/resources/wa

1. Install the Control
MOUNTING HOLES (4) WIRE ROUTING CLIPS (3) BACK CASE BATTERY CABLE CHANNEL TIE WRAP POINTS (3)

2. Make Wiring Connections
WARNING TO PREVENT RISK OF SHOCK, DISCONNECT TELEPHONE LINE AT TELECOM JACK BEFORE SERVICING THIS UNIT INCOMING PHONE LINE PREMISES TELEPHONE UL NOTE THE MINIMUM WIRE SIZE USED FOR TELEPHONE INSTALLATIONS MUST BE #26 GAGE ALL OUTPUT CIRCUITS ARE POWER LIMITED. NOTE USE ONLY THE 300-04705/300-04605 OR 300-04063 POWER SUPPLY PROVIDED 300-04705 or 300-04605 (300-04063 CANADA) POWER SUPPLY 9V, 2.7A OBSERVE POLARITY WHEN CONNECTING THE POWER SUPPLY TO THE TERMINAL STRIP.

3. Install the Communications Module
ETHERNET CABLE TO ILP5 NOTE: SIM CARD INSTALLED IN GSMVLP5 ONLY

4. Make Battery Connections
SCREW SCREW RETAINER RETAINER

RJ45 RECEPTACLE LYNX TOUCH

STANDARD/HIGH CAPACITY BATTERY CONNECTORS

ALTERNATE INSTALLATION
ILP5 SPACER RJ45 RECEPTACLE ROTATED 180 ILP5 TIE WRAP (1)

INCOMING PHONE LINE

ILP5 RECEPTACLE KNOCKOUT

EARTH GROUND

HARD WIRED ZONE
2K OHM EOLR

TRIGGER OUTPUT (NEG) (3ma)

ILP5 SPACER

SUPER HIGH CAPACITY BATTERY CONNECTOR

REMOVE ILP5 KNOCKOUT

REMOVE ILP5 SPACER

LYNXRCHKIT-SHA (P/N 300-03866)

LYNXRCHKIT-SC (P/N 300-03864-1)

POWER SUPPLY RECEPTACLE ROTATE FRONT CASE UPWARD TO RELEASE HOOKS

CONNECTOR BOARD

OR
TIE WRAP POINT

TIP RING TIP

RING

MOUNTING HOOKS (HINGES)

POWER SUPPLY CONNECTOR
SIM CARD CONNECTOR BOARD

EGND

HWZ1

GND

TELCO JACK

GSMVLP5/ILP5 RECEPTACLE TAMPER SWITCH FRONT CASE

PHONE GSMVLP5/ILP5 RECEPTACLE

ZONES

POWER
ROTATED 180 RECEPTACLE

+9VDC

H/S T

TIP

H/S R

RING

TRIG

GND

TELEPHONE CONNECTIONS

TERMINAL STRIP

GSMVLP5

SCREW (3)

TIE WRAP POINTS (2) LOCKING TABS
5000-100-050-V1

CONNECTOR BOARD

WEEKLY TESTING IS REQUIRED TO ENSURE PROPER OPERATION OF THIS SYSTEM

5000-100-172-V0

LYNX TOUCH
5000-100-173-V0

Note: For the complete Summary of Connections, refer to the LYNX Touch Series Installation and Setup Guide P/N 800-06834 or higher.

Ensure that SIM card and the connector board are securely installed in the communications module before installing it in the LYNX Touch.

5000-100-018-V1

1. Release the front case from the rear case by depressing the two locking tabs at the top of the unit with the blade of a medium size screwdriver. 2. Separate the front and back case assemblies by rotating the front case so that it is perpendicular to the rear case and unsnapping (releasing) the two hooks (hinges) from the back case. 3. Feed the wiring through the appropriate openings in the back case. Use tie wraps to secure the wiring to the built-in wire loops as needed. 4. Mount the back case to a sturdy wall and secure with the provided screws. 5. Attach the front and back cases by connecting the hooks on the front case to the attachments on back case. Once attached, the hooks will support the front case and allow you to make the wiring connections. 6. After all of the wiring connections have been made, snap the front case and back case closed and ensure that the locking tabs secure the case.

1. Make earth ground connections to EGND terminal. 2. Connect the incoming phone line to either the 8-position jack or the TIP and RING terminals. 3. Connect the handset phone lines to the H/S T (TIP) and H/S R (RING) terminals.
Note: For full line seize operation, refer to the LYNX Touch Series Installation and Setup Guide.

4 Connect the sensors/contacts to the HWZ1 (+) and GND (-) terminals. 5. If used, install the GSMVLP5 or ILP5 communications module Refer to the Install the Communications Module section or to the Installation Guide for the Communications Module (P/N 80001115 or higher). 6. Connect wires from the 300-04705/300-04605 OR 300-04063 (Canada) Power Supply to GND (-) and +9VDC (+) terminals OR plug the Power Supply connector into the receptacle on the LYNX Touch.

1. If you are installing the ILP5 module, use a wire cutter or knife to cut the plastic tabs that secure the ILP5 spacer to the back case of the LYNX Touch. If you are installing the GSMVLP5 module, proceed to step 3. 2. Remove the ILP5 receptacle knockout from the left side of the LYNX Touch back case 3 Install the Communications Module into the front case. Ensure that the connector board is properly seated into the receptacle on the control. 4 Secure the module with the three provided screws. If you are installing the ILP5 module, proceed to step 5. If you are installing the GSMVLP5 module, proceed to step 8 5. Insert the ILP5 receptacle and spacer into the slot on the back case. 6. Secure the communications cable to the tie wrap point on the ILP5 with the provided tie wrap. 7. Connect the Ethernet cable to the RJ45 receptacle. 8. Enable the module, configure alarm reporting and module supervision and register the device. Refer to the “Program the Radio” and “Diagnostics” sections of the LYNX Touch Installation Guide (P/N 800-06834 or higher).

1. 2. 3. 4. 5. 6. 7.

Remove screw securing the battery retainer. Remove the battery retainer. Insert battery pack into back case. Install battery retainer. Install screw to secure the battery retainer. Connect battery connector to receptacle on PC board. After all wiring connections have been made, snap the front case to the back case so it is held by the locking tabs. 8. Plug the Power Supply into a 24-hour, 110VAC unswitched outlet.
Note: Rechargeable batteries may take up to 48-hours to fully charge. “Battery Low” message should clear within four hours, or by entering Test Mode.
Battery Part Number LYNXRCHKIT-SC (300-03864-1) LYNXRCHKIT-SHA (300-03866) Battery Standby Time (Minimum) 4-hours 24-hours

Low Battery Notification Approx. 1-hour before battery depletion At least 1-hour before battery depletion

Ê800-06896(Š
800-06896 3/11 Rev. A

2 Corporate Center Drive, Suite 100 P.O. Box 9040, Melville, NY 11747
Copyright © 2011 Honeywell International Inc. www.honeywell.com/security

Programming Notes
Entering Installer Programming mode
1. Power-up the control and select the “more” tab on the first page of the Home Screen. 2. Select “Tools” button. 3. Enter the 4-digit Installer Code (4-1-1-2). 4. Select “Program” button. 5. The System Programming Screen will appear and the “ARMED” and “READY” LEDs will flash.

5. Program the Control
Change the Installer Code
The factory default Installer Code for the LYNX Touch Series Control is set to 4-1-1-2. To change this code, you must enter Programming mode. 1. Select “Program” button. 2. Select “Installer Code” button. 3. Enter a new 4-digit Installer Code. 4. Select “Done” button

6. Add Wireless Sensors
Add a Sensor
To add, edit or delete Wireless Sensors you must enter Programming Mode. 1. Select “Zones” button. 2. Select “’Add new” button. 3. Select the applicable Zone button. 4. Select “Serial Number” Button 5. Enter Serial Number or Enroll via RF Learning. To enroll the transmitter, three (open/close) transmissions of the device will be required. 6. If desired, program the following options: Loop Number Zone Description 1 and 2 Device Type Response Type Alarm Report Chime Supervision 7. Select “Save”.

6. Add Wireless Keys
To add, edit or delete a Wireless Key you must enter Programming Mode.

Add a Wireless Key
1. Select “Keys” button. 2. Select ’Add New” button. 3. Select the “Key Type” button and scroll through the available key types. 4. Select “Serial Number” Button 5. Enter Serial Number or Enroll via RF Learning. To enroll the transmitter, three (open/close) transmissions of the device will be required. 6. Select the “User” button and then select the User that will be associated with the key that is being enrolled. Note: In order for the Key to function, a valid User Code must be associated with the User that has been assigned to the key. 7. If desired, program the following options: Zone Button Key * - Zn ** 8. Select “Save”.
* Button number is determined by the type of key being enrolled. ** Zn No. based on the type of key being enrolled.

Exiting Programming mode
1. Once programming is completed, at the System Programming screen, select the “ ” button. 2. Select the “Yes” when the system prompts “Allow Installer to Re-Enter Programming?”. 3. Select the “ ” button to return to the Home Screen.

Program Date
Note: If you are installing a GSMVLP5 or ILP5 Communication Module, the time and date will be programmed and updated automatically via Central Station. You must still program the correct Time Zone To change this code, you must enter Programming mode. 1. Select “Program” button. 2. Select “Date Time” button. 3. Enter the date, time and time zone as required. 4. Select “Save” button.

Entering Master User Programming mode
1. Power-up the control and select the “more” tab on the first page of the Home Screen. 2. Select “Tools” button. 3. Enter the 4-digit Master User Code (1-2-3-4). 4. The Master User Programming Screen will appear and the “READY” LED will remain lit. 5. Select the applicable programming function from the Master User screen.

Program Defaults
LYNX Touch is pre-programmed at the factory with a built-in set of default values. Refer to the Programming Default Tables section of the LYNX Touch Series Installation and Setup Guide (P/N 800-06834 or higher) to view the Default Tables. To select factory defaults from a set of four tables, you must enter Programming mode. 1. Select “Program” button. 2. Select “Default Config.” button. 3. Select the desired Default Table. 4. Select “Yes” when the confirmation screen appears.

Edit Wireless Sensor/Zone information
1. 2. 3. 4. Select “Zones” button. Select the Zone you wish to edit and then select the “Edit” button. Edit the applicable zone programming fields as required. Select “Save”.

Edit Wireless Key information
1. 2. 3. 4. Select “Keys” button. Select the Key you wish to edit and then select the “Edit” button. Edit the applicable fields as required Select “Save”.

Exiting Programming mode
1. Once programming is completed, select the “back” tab to return to the Home Screen. OR 2. Depress the “Off” key and then select the ‘Cancel” button. 3. The system will return to the Home Screen.

Delete a Wireless Sensor
1. Select “Zones” button. 2. Select the Zone you wish to delete then select the “Delete” button. 3. Select the “Yes” button when the confirmation screen appears.

Delete a Wireless Key
1. Select “Keys” button. 2. Select the Key you wish to delete then select the “Delete” button. 3. Select the “Yes” button when the confirmation screen appears.

7. Add Central Station Accounts
To add Central Station Account information, you must enter Programming Mode.

8. Register the Communications Module
The Communications Module can be registered either via the Alarmnet Direct Website, by Phone or through the LYNX Touch Diagnostics. For additional information on the first two methods refer to the LYNX Touch Installation and Setup Guide P/N 800-06834 or higher.

9. Program User Functions
To perform these functions, you must enter the Master User Programming mode. Add Users
1. 2. 3. 4. 5. 1. 2. 3. 4. 5. Select the “Users” button. Select the “Add New” button. Enter a User Name. Enter a 4-digit User Code. Select “Done”. Select the “Users” button. Select the “Master” button. Select the “Edit” button. Enter a new 4-digit User Code. Select “Done”.

10. Test the system
To perform this function, you must enter the Installer OR Master User Programming mode.
1. Select the “Test” button or icon. 2. Select the “Walk Test” button or icon. 3. Open each protected door and listen for three beeps from the keypad, followed by the zone’s Voice Descriptor. Identification of each faulted protection point should appear on the display, and clear when the door is closed. 4. Walk in front of the motion sensor and listen for three beeps and the zone’s voice descriptor. 5. When testing is complete, enter an OFF sequence. 6. Press each key on the key fob to confirm it performs its assigned function.
Note: Refer to the Lynx Touch Series User Guide P/N 800-06894 or higher for additional information.

Add First or Second Central Station Information
1. Select the “Reporter” button. 2. Select the “Primary Central Station” or “Secondary Central Station” button. 3. Program the following fields as applicable: Phone Type Phone Number Communicator Type Account Number Dynamic Priority Dynamic Delay Report All Report Alarms Report Troubles Report Open/Close Report Tests 4. Select the “Save” button when programming is complete.

Register through LYNX Touch Diagnostics
To Register the Communications Module, you must enter Programming Mode. 1. Select the “Comm./ Diagnostics” button. 2. Select the “Setup Communications” button. 3. Select the “Register Device” button. The registration message is sent and the unit waits for the acknowledgement. (Refer to the LYNX Touch Installation and Setup Guide P/N 800-06834 or higher for additional information)

Change the Master User Code

Change/Edit Users or User Codes
1. Select the “Users” button. 2. Select the applicable “User” button. 3. Select the “Edit” button.

All four digits of the Central Station Account numbers must be entered. For ten-digit format, all ten digits must be entered. Refer to the Lynx Plus Series Installation and Setup Guide for additional information regarding these programming options.

4 Revise the User name, if applicable, then select the “Done” button.
5. Enter a new 4-digit User Code, if applicable, then select the “Done” button.

Delete User Codes
1. 2. 3. 4. 5. Select the “Users” button. Select the applicable “User” button. Select the “Delete” button. Enter a new 4-digit User Code. Select “Yes” when the confirmation screen appears.