WORKSHEET
for




80 OUTPUT FUNCTION PROGRAMMING


Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you
enter the data during the displays and prompts that appear in sequence.

Notes:

1.
For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.

2.
For Powerline Carrier devices (plcd), field

27 must be programmed with a House Code.

3
. Tampers of expansion units cannot be used to operate devices.
Activation Type and Detail
Event (for zone list/activated by)
Output
Function
Number
(V20P=1-48)
(V15P=1-24)
Activated by
0=delete
1=zn list
2=zn type
3=zn no.
Zone List
(ZL)
1-8 = list
Zone Type
(ZT)
(see table
below)
Zone No.

(ZN)

00=none

V20P: 01-64

V15P: 01-06,
09-34, 49-56
Partition
Number
(P)
(if using ZT trig)
0 = any
1 = partition 1
2 = partition 2
3 = common
By Zone List

0 = restore
1 = alarm
2 = fault
3 = trouble
By Zone No.

0 = restore
1 = alrm/flt/trbl
Action
0 = off
1 = close 2 secs
2 = stay closed
3 = pulse
4 = toggle
5 = duration 1
††

6 = duration 2
††

Output
Number

V20P=1-18

V15P=1-8,
17, 18
Device
Type

R = relay
T = trigger
X = X10
1










2










3










4










5










6










7










8










9










10










11










12










13










14










15










16










17










18










19










20










21










22










23










24










25










26










27










28










29










30










31










32










33










34










35










36










37










38










39










40










41










42










43










44










45










46










47










48











ZONE TYPE/SYSTEM OPERATION

Choices for Zone Types are:


00 = Not Used
05 = Trouble Day/Alarm Night 10 = Interior w/Delay
24 = Silent Burglary

01 = Entry/Exit#1
06 = 24 Hr Silent
12 = Monitor Zone
77 = Keyswitch
02 = Entry/Exit#2
07 = 24 Hr Audible
14 = Carbon Monoxide
§§

81 = AAV Monitor Zone
03 = Perimeter
08 = 24 Hr Aux
16 = Fire w/Verification 90-91 = Configurable
04 = Interior Follower 09 = Fire
23 = No Alarm Response

§§
when used with an output function,
the carbon monoxide zone type
activates only upon CO alarms. Does
not activate for trouble conditions.
Choices for System Operation are:

20 = Arming

Stay
38 = Chime
58 = Duress

21 = Arming

Away
39 = Any Fire Alarm
60 = AAV Trigger


22 = Disarming (Code + OFF)
40 = Bypassing
61 = AVS/GSMV session begin
§

31 = End of Exit Time
41 = **AC Power Failure
62 = AVS/GSMV session end
§


32 = Start of Entry Time
42 = **System Battery Low
66 = Function key


33 = Any Burglary Alarm
43 = Communication Failure 67 = Bell Failure


36 = **At Bell Timeout***

52 = Kissoff

68 = TELCO Line Fault


54 = Fire Zone Reset

78 = Keyswitch red LED
†††



79 = Keyswitch green LED
†††



Note:
In normal operation mode:
Code + # + 7 + NN Key Entry
starts
Device
Code + # + 8 + NN Key Entry
stops
Device

** Use 0 (any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.

Use *57 Menu mode to assign the function key.
††
Duration is set in program field *177.
†††
Device action not used for these choices.
§
automatically set when appropriate AVS Quick
Command performed.