1
-
Step
-
by
-
Step
Tech Support
Updated 12/14/20
Partitioning the 5828/V
keypads
on Low Plus
Panels
The 20P family of panels
will only
send P
artition 1
status out on the House ID in *24,
Partition 2 and 3 are not sent. If you have a 5828 keypad on Partition 2
you must add an RF
keypad to
Partition 2
to
send status
. The internal TM module of this keypad will send the
assigned P
artition 2 status to the 5828/V keypad. A few suggestions for setup are shown
below.
(‘RF Keypads’ refers to
6150RF, 6152RF, FA260RF, FA270RF, 6160RF, FA570RF
, 6162RF
, etc)
61
60RF,
FA570RF
, and 6162RF
will not work in some situations below. See notes***
5828/V
Setup on Partition 1
Only
*
- Field *24 in panel Partition 1
Ho
use ID must be programmed if using bi
-directional
device on partition 1 so the panel can send/receive House ID signals on this
partition.
20P Control
Panel
H
ouse ID
in *24
= 01
for partition 1
*
Partition 1 RF Keypad
or 5883H
Tranceiver
**
Partition 1 5828/V
Keypad with House
ID = 01 + other
wireless transmitters
-
2
-
Step
-
by
-
Step
Tech Support
Updated 12/14/20
5828/V
on
Partition 2
with an E
xisting
R eceiver
on Partition 1.
*
- Field *24 in the panel is not used for P2 because the 5828 will send and
receive on the
local House ID in the RF keypad on partition 2.
**
- The RF keypad on partition 1 (if used)
should
have its receiver enabled to receive
signals from any
other
wireless transmitters
on the system.
**
* The
6160RF and FA570RF keypa
ds can
’t be used in P2 in this scenario because they will not
receive in the local mode. For simplicity use a 6150RF/6152RF/6162RF instead.
If you have to use a 6160RF/FA570RF here you can
program the House ID in *24 for P2, and
then the existing receiver on P1will receive the 5828 signals and the 6160RF/FA570R
F will send
the P2 status on it
s local House ID.
****This 5828 can send
and receive
signals via the House ID of the RF keypad in the Local
Mode.
The receiver must be disabled in the RF keypad on Partition 2 since there is an
existing receiver
on P1
and the panel can only
communicate with
one receiver.
The House
ID in the RF keypad
on P2
must be programmed as local and should matc
h the House ID
programmed in
the
5828 on P2
. The local House ID in the keypad allows that keypad to
send its partitioned status to the 5828.
20P Control
Panel
N
o House ID
needed in *24
*
Ex
isting 5881 or 5883 or
RF keypad **
receiver
for
wireless zones.
RF Keypad
***
on
P
2
House ID = 02 locally in
keypad.
P
2 5828/V Keypad
House ID = 02**** -
3
-
Step
-
by
-
Step
Tech Support
Updated 12/14/20
5828/V
on
Partition 2 with an
RF
K eypad
as the Only
Receiver
for other
Wireless Transmitters
*
- Field *24 in panel is not used. Signals are sent and received on the RF keypad local
House ID
**
- The House ID in keypad must be for “L
ocal” with the House ID 02 for the keypad to
send partition 2 status to the 5828. The receiver must be enabled in the
RF keypad
so it
will receive signals from
all other wireless transmitters in partition 1
and 2
.
***
Neither th
e 6160RF
, FA570RF
, or 6162RF
will work in this application
if there are
other
wireless zones bec
ause w
ith the receiver enabled
in those RF keypads there
is no
Local
House ID reference for partition 2
, therefore
it will not give out status on Partition 2 House
ID
. If there are NO
other wireless devices except the 5828, then the 6162RF can be used
here (Loca
l House ID Mode, receiver disabled), but not the
6160RF or
FA570RF
.
20P Control
*24 House ID
is
not used
*
Standard keypads
on
partition 1.
No RF receiver
Add
RF
Keypad
***
to
partition 2 with
receiver enabled and
Local House ID = 02
**
Partition 2 5828/V
Keypad with House
ID = 02 + other
wireless transmitters
-
4
-
Step
-
by
-
Step
Tech Support
Updated 12/14/20
5828/V’
s S
etup on Both P
artitions
.
*
- Field *24 in panel House ID must be programmed if using bi-
directional device for
partition 1 so the panel
can send/receive House ID signals on partition 1.
The RF keypad
on
partition 1
should be programmed to use the panel House ID, and must have its
receiver
enabled if other wireless devices are used.
** -
This 5828 can send
and receive
signals via the House ID of the RF keypad in the Local
Mode.
The receiver must be disabled in the RF keypad on Partition 2 since there is an
existing receiver
on P1
and the panel can only
support
one receiver.
The House
ID in the RF
keypad
on P2
must be programmed as local and should match the House ID
programmed in
the
5828 on P2. The local House ID in the keypad allows that keypad to send its partitioned
status to the 5828. Keep in mind that partition 2 House ID must be different from partition
1 House ID
***
If the
6160RF or FA570RF keypads is used here the House ID for P2 must be programmed in
*24 so the existing receiver on P1 will receive the 5828 signals. (The 6160RF and FA570RF do
not receive when in Local mode, they only transmit.)
20P Control
Partition 1
RF Keypad
or 5883H
House ID = 01 in *24
of panel.
*
Partition 2
RF Keypad
***
House ID = 02 locally in
keypad.
Partition 1 5828/V
Keypad with House
ID = 01 + other
wireless transmitters
Partition 2 5828/V
**
Keypad with House ID =
02