Interlogix TX+2WAYFOB - Install Guide Dated 09/2018
Related Products
Related Categories
Document Transcript
P
/N 466
-
5423
• REV
A • 20
SEPT
2018
©
2018 United Technologies Corporation. All rights reserved
TX+
2WAYFOB Wireless Keyfob
Installation Instructions
PLEASE SEE REVERSE SIDE FOR IMPORTANT PRODUCT
WARNINGS AND DISCLAIMER INFORMATION.
Description
The TX
+2WAYFOB
is
a
n unsupervised
wireless keyfob
device
that when within
operational
range of an Interlogix control panel or receiver, can remotely arm,
disarm, and perform other functions specific to the system.
The TX
+2WAYFOB
features the TX+ Encryption protocol which provides encrypted
wireless communication to select Interlogix contr
ol panels
, as well as 2
-
way
communication functionality providing acknowledgement at the device via the tri
-
color LED that transmissions sent have been received by the panel
. Please refer to
your panel’s installation instructions to see if it is TX+ Encryp
ted capable.
The TX+2WAYFOB
also utilizes the standard ITI
-
319 protocol which is compatible
with all Interlogix control panels and receivers.
When enrolled into a panel and
operating in the standard ITI
-
319 mode, the device functions in 1
-
way mode only
and
does not receive acknowledgement signals back from the panel.
Figure
1
:
TX
+2WAYFOB
Enrollment
Into TX+ Encryption Supported Panels
To enroll the
TX
+2WAYFOB as an encrypted keyfob
into
a panel that supports the
TX+ Encryption protocol
,
follow these
steps:
1)
Place the panel into program mode, then go to Learn Sensors menu.
Refer to your specific alarm panel manual for details on these menus
.
2)
Once the Learn Sensors mode has been activated
, press
and hold
both
the
STAR
and
LOCK
buttons together for 5 s
econds
.
The LED
will blink red one time upon transmission, followed by an alternating RED
and GREEN blinks (6 times total) for successful acknowledgement of
enrollment into the panel.
3)
If the panel does not respond
after complet
ing step 2,
repeat as
necessary until the device is successfully enrolled into the panel.
Note: Utilization of the TX+ Encrypted protocol is only compatible with select
Interlogix control panels. When enrolled into a panel that is TX+ Encrypted
capable, the enrollment
menu screen may indicate “TX+ Encrypted” to verify
that the sensor is communicating to the panel via the encrypted protocol.
Please refer to your panel’s installation instructions to verify that the panel
supports TX+ Encrypted capability.
If the keyfob is unintentionally enrolled
into a TX+ Encryption supported panel in the
standard ITI
-
319 protocol mode, the device will need to be removed from the panel,
and the keyfob Reset/Restore function
will need to be performed before attempting
to r
e
-
enroll in the TX+ Encryption mode. The Reset/Restore function is performed by
pressing and holding the UNLOCK and LIGHT buttons together for 5 seconds.
The LED will remain illuminated green for 3 seconds following the successful
reset/restoral
.
Enrollment
into
Non TX+ Encryption Sup
ported Panels (ITI
-
319 Protocol, one
-
way mode only)
To enroll the TX
+2WAYFOB
into a panel
utilizing the standard ITI
-
319 protocol,
follow these steps:
1)
Place the panel into program mode, then go to Learn Sensors menu.
Refer to your specific alarm panel manual for details on these menus.
2)
Once the Learn Sensors mode has been activated,
press
and hold both
the
LOCK
and
UNLOCK
buttons together for 5 second
s
.
The LED will blink red one time upon transmission.
Then select the
appropriate sensor group and number
on the panel
. Refer to your specific
alarm panel manual for details on the different sensor groups.
3)
If the panel does not
respond
after completing step 2
,
repeat as
necessary.
Note: When the TX+2WAYFOB is enrolled into a panel utilizing the standard ITI
-
319
protocol, the 2
-
way communication functionality is not available and it will operate as
a standard 1
-
way device.
Operation
in TX+ Encrypted Mode
When the TX+2WAYFOB is enrolled into an Interlogix panel/receiver that supports
the TX+ Encrypted protocol, and the device is communicating via the TX+ Encrypted
protocol, the following chart indicates the different transmissions poss
ible, along with
their corresponding LED acknowledgements
after the initial RED blink upon
transmission
:
FUNCTION
KEYFOB ACTION
LED RESPONSE
PANEL STATUS
Enrollment
Hold STAR and LOCK
together
for 5 seconds
RED LED blink
once, followed by
RED/GREEN
alternating
Device
successfully
enrolled
Arm Stay
Press LOCK once
RED LED
blinks 2 times
Panel Armed
Stay
Arm Away
Press LOCK twice
RED LED
blinks 4 times
Panel Armed
Away
Disarm
Press UNLOCK once
GREEN LED
blinks 3 times
Panel Disarmed
Panic
Hold
LOCK and UNLOCK
together
for 3 seconds
RED/GREEN
alternating
Panic Alarm
Re
-
sync
(only done
during sensor
test mode)
Hold STAR and LOCK
together
for 5 seconds
RED/GREEN
alternating
Device
successfully
resynchronized
Reset/Restore
Hold UNLOCK and LIGHT
together
for 5 seconds
GREEN LED
stays on for 3
seconds
Keyfob reverts
back to factory
defaults
P
/N 466
-
5423
• REV
A • 20
SEPT
2018
©
2018 United Technologies Corporation. All rights reserved
Trouble Conditions in TX+ Encrypted Mode
After the TX+2WAYFOB is enrolled into an Interlogix panel/receiver that supports the
TX+
Encrypted protocol, and the device is communicating via the TX+ Encrypted
protocol, the following chart indicates the different trouble conditions that can occur,
identified by the following LED responses on the keyfob:
Keyfob Action
LED Response
Meaning
When any button
press or
sequence
is
initiated
YELLOW LED
blinks 3 times
System cannot arm/
disarm
/
perform
function
due to
trouble condition
at
panel
.
Refer back to the panel to understand
what trouble condition exists
When any button
press or sequence
is initiated
YELLOW LED
stays on for 3 seconds
No acknowledgement received from the
panel
. When this occurs, two conditions
may exist:
1) the panel has received
the keyfob
transmission and has entered into the
desired state, but the keyfob is too far o
ut
of range to receive the acknowledgement
messages back from the panel.
2) the keyfob is too far out of wireless
range and the panel did NOT receive the
keyfob transmission, resulting in no state
change at the panel
When any button
press or sequence
is
initiated
RED/GREEN/YELLOW
alternating
LED blinks
Re
-
sync required (panel needs to be
placed into Sensor Test Mode and the re
-
sync function needs to be completed)
Operation in ITI
-
319 Mode
When the TX+2WAYFOB is enrolled into an Interlogix panel/receiver
and the device
is communicating via the
ITI
-
319
protocol, the following chart indicates the different
transmissions possible, along with their cor
responding LED acknowledgements.
Please refer to your panel’s installation instructions for further detail on
which keyfob
functions may or may not be available.
LOCK
Depending on your control panel:
Press once to arm in Stay mode.
LED blinks RED once upon transmission.
Press twice to arm in Away mode.
LED blinks RED once upon transmission.
UNLOCK
Press this button to disarm the system.
LED blinks RED once upon transmission.
LIGHT
For NetworX panels, press this button to arm the system in Stay mode.
For Concord
or Simon XT, it can turn
system
-
controlled
lights on or off. LED blinks RED once
upon tr
ansmission.
STAR
The star button function depends on the individual panel programming. Refer to the
installation instructions for your panel. LED blinks RED once upon transmission.
PANIC or AUX
If the keyfob is programmed using a panic or portable auxili
ary group number,
pressing the LOCK and UNLOCK buttons simultaneously will activate an audible or
silent alarm (depending on the group number) and initiate reports to the central
station. LED blinks RED once upon transmission.
Replacing the Batter
y
The
TX+
2WAYFOB
comes pre
-
installed with a single
Panasonic
CR
-
245
0
Lithium
coin
-
cell battery that provide up to 10
years of battery life
under normal usage
conditions.
Because keyfobs are non
-
supervised devices, a low battery signal will
only be received by the
control panel when the device is within range of the receiver
and a button is pressed (if the device is not in use, no low battery signal will be sent
until a button is pressed). When the device is carried beyond the range of the
receiver and/or is seldom
used/tested, the battery could wholly deplete without a
warning of the battery condition being sent to the panel. If the LED on the device
appears dim or does not turn on when a button is pressed, it is a warning that the
battery may be low or depleted and
should be replaced. To ensure proper
functionality, test the device weekly and follow these simple steps to replace the
battery when necessary:
1)
Remove
the case cover from the back housing by inserting a small flat
head scre
wdriver into the slot at the
bottom
of the
device and press
on
the tab.
2)
Remove the existing
battery
and re
-
install
a new
Panasonic
CR
-
2450
battery. When inserting the battery
, pay close attention to the battery
polarity indicators to ensure p
roper
placement.
3)
Replace the case cover
and
perform a sensor test to ensure proper
communication to the panel/receiver.
TX+
2WAYFOB
RF Frequency
319.
5
MHz
–
(Crystal
Based
)
Compatibility
(TX+ Encrypted)
Only Select
Interlogix 319.5 MHz
control panels/receivers
(refer to
panel’s installation instructions to
verify compatibility)
Compatibility
(Standard ITI
-
319)
All Interlogix 319.5 MHz control
panels/receivers
Battery Type
1
x
CR
-
2
450
(Panasonic)
Typical Battery Life
Up to 10
years at 68°F (20°
C)
Operating
Temperature Range
32° to 120°F (0° to 49
°C)
Relative Humidity
0
-
95
% non
-
condensing
Supervisory Interval
Unsupervised
Storage Temperature Range
-
30
°
to 140°F (
-
34 to 60°C)
Dimensions
2.25
” x
1
.25” x 0.5
”
FCC Compliance Statement
This device complies
with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept any interference received, including interference that may
cause undesired operation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
•
Reorie
nt or relocate the receiving antenna.
•
Increase the separation between the equipment and receiver.
•
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
•
Consult the dealer or an experienced rad
io/TV technician for help.
Changes or modifications not expressly approved by UTC Fire and Security could void the user’s authority to operate the
equipment.
This device complies with Industry Canada
license
-
exempt RSS standard(s). Operation is subject
to the following two
conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including
interference that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts
de licence standard RSS (s). Son fonctionnement est soumis aux
deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnemen
t de l'appareil.
In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be installed
such that a minimum separation distance of 20 cm is maintained from the general population.
Conformément aux exigenc
es d'Industrie Canada en matière d'exposition humaine aux champs de radiofréquences,
l'élément rayonnant doit être installé de telle sorte qu'une distance minimale de 20 cm soit maintenue par rapport à la
population générale.
FCC
:
2ABBZ
-
RF
-
FOB
-
319
-
2W
IC:
11817A
-
RF
FOB319
2W
This Class B digital apparatus complies
with Canadian ICES
-
3B.
Cet appareil numérique de la classe B est conforme à la norme NMB
-
003 du Canada.
Contact information
For contact information, visit us online at www.interlogix.com.
For technical support, see
www.interlogix.com/support
Copyright
Copyright © 201
8
United Technologies Corporation. All rights reserved.
Trademarks
Interlogix is a registered trademark of United Technologies Corporation. Interlogix is part of UTC Climate, Controls & Securi
ty, a
unit of
United Technologies Corporation.
Product Warnings and
Disclaimers
WARNING: CHOKING HAZARD
-
Small
parts. Keep away from children.
ATTENTION: RISQUE D'ÉTOUFFEMENT
–
Petite pice. Garder eloigner des enfants.
THESE PRODUCTS ARE INTENDED FOR SALE TO, AND INSTALLATION BY, AN EXPERIENCED SECURITY
PROFESSIONAL. UTC FIRE & SECURITY
CANNOT PROVIDE ANY ASSURANCE THAT ANY PERSON OR ENTITY
BUYING ITS PRODUCTS, INCLUDING ANY “AUTHORIZED DEALER”, IS PROPERLY TRAINED OR EXPERIENCED TO
CORRECTLY INSTALL SECURITY RELATED PRODUCTS.
CES PRODUITS SONT DESTINÉS À ÊTRE VENDUS ET INSTALLÉS PAR UN
PROFESSIONNEL DE SÉCURITÉ
EXPÉRIMENTÉ. UTC FIRE & SECURITY NE PEUT FOURNIR AUCUNE ASSURANCE QUE TOUTE PERSONNE OU
ENTITÉ QUI ACHETERA SES PRODUITS, Y COMPRIS TOUT «DÉTAILLANT AGRÉÉ», EST CORRECTEMENT
FORMÉE OU EXPÉRIMENTÉE À INSTALLER CORRECTEMENT LES PROD
UITS LIÉS À LA SÉCURITÉ
For more information on warranty disclaimers and product safety information, please check
https://firesecurityproducts.com/policy/product
-
warning or scan the following code:
- Uploaded