1
4
FEB
14
1
/
4
Description
The
Personal Panic Device
is a wireless
device
that can be
u
sed to activate police or
auxiliary alarms throughout the premises.
When the help button is pressed,
both red
LEDs flash and information is transmitted.
The t
ransmitted
signal in
clude
s
alarm and
battery status
information
.
When the help
button is released
, an alarm
-
restore
-
all
message is sent.
Note:
To activate, p
ress
and hold
the help button until the red LEDs
stop flashing, then release the button.
The
Personal Panic Device
is shipped with
a watch type wristband installed
.
A
pendant
adaptor kit and lanyard are also included
for
an
optional
necklace arrangement
.
The
pendant
kit includes
a
pendant
loop and a
pendant
plug
(shown below)
.
The Personal Panic Device is water
resistant and has been tested
in water
at
three meters for one hour
.
Installation
Assembly
G
uidelin
e
s
•
P
rogram the
Personal Panic Device
into
the appropriate
panel groups.
Refer to the
“Programming”
section for
more information.
•
The transmitter
on the Personal Panic
Device
has a
maxi
mum
range of 375
feet
.
Test the device at the outer limits
of the installa
tion
to ensure it works
properly
. The outer limits may vary due
to
different environments
that
may
affect the range.
Refer to the
“
Testing
”
section for mor
e information.
•
Verify
the
user
can activate the
help
button
by pressing it with their thumb
or
finger.
•
When worn as a
pendant
,
it is
important that the user
does not
activate
the
help
button by pressing it
against their chest. This may reduce
the signal’s effective range.
Watch
S
tyle
W
ristband
Adjust the length of the
wristband
by
m
easur
ing
and cut
ting
the band in the
following
manner:
1
.
Position the
wrist
band
tightly
around
the
wrist
and
in the intended position
as shown in Step 2.
2
.
Using a washable marker, place a
mark on
the edge of each strap, near
the center of the
wrist.
Personal
Pani
c Device
In
stallation Sheet
2
/
4
Personal Panic Device Installation Sheet
3
.
Align the band so the ends of the band
are even. Cut the band in the center of
the two marks as shown below
.
4
.
Attach
the band to the cl
asp. Feed
the
band through
the
retainer openi
ng and
close
the
lever to lock
the
band in
place.
Repeat for
the
other side.
Pendant
The
Personal Panic Device
can be worn as
a
pendant
by removing the wristband and
installing the
pendant
adaptor components
and lanyard
in the following manner:
1
.
Remove the two screws on the back of
the
Personal Panic Device
.
2.
Carefully separate the cover and base.
3.
Remove the wristband.
4
.
Separate the components from the
pendant
adaptor kit and discard the
circular center section.
5.
Insert the
pendant
loop adapter into
the small loop end of the lanyard.
6
.
Insert the
plugs
into the base and
reattach the cover and base.
Note:
Compress
the
panic
button
and base
assembly
together before tigh
t
ening
the screws.
Programming
Review the following information for adding
a
Personal Panic Device
to
the
panel. Refer
to the specific panel
Installation
Instructions
for further detail.
1
.
Set the panel to
Program Mode.
P/N
466
-
4431
• REV
B
•
1
4
FEB
14
3
/
4
2.
When prompted, enter the
appropriate
group number and select the desired
sensor number.
3.
Press the help button
on the Personal
Panic Device
to trip the selected
sensor.
4.
Exit from
Program Mode.
Maintenance
and
T
esting
Testing
Review the following for testing the help
button. Refer to the
specific panel
Installation
Instructions
for further detail.
1
.
Set the panel to
Sensor Test Mode.
2.
Press
and hold the
help
button
for a
second
to monitor the beeps for the
packet count
.
3.
Liste
n for
the
panel siren. Yo
u should
hear
6 to 8
beeps.
4.
Test the help button from several
lo
c
ations to ensure a consistent
response.
5.
T
est the
help
button weekly
to ensure
proper operation
.
6.
Verify the end
-
user can operate the
unit without any difficulty.
Cleaning
1.
Gently rub a lanoline
-
b
ased cleaner,
such as Go
-
Jo, onto all surfaces of the
Personal Panic Device t
o remove any
debris.
2.
Rinse off using warm water.
3.
Wipe clean using a dry, lint
-
free cloth.
Re
placing the
B
attery
CAUTION
: To avoid an alarm
condition set the panel to
Sensor
Test
Mode
prior to changing the battery.
Pour éviter une condition d'alarme
metter le panneau en Mode d'essai
des capteurs avant de changer la
batterie.
CAUTION
:
Use
static electricity
precautions
when handling electronic
components.
Utiliser les
précautions de l'électricite
statique lors de la manipulation des
composants électroniques
.
1.
Depending on the situation, it may be
necessary to contact the central
monitoring station before starting the
installation.
2
.
Remove the two screws on the back
of
the
Personal Panic Device a
nd
observe how the
pendant
or wristband
components are
attached
.
3
.
Carefully
separate the cover and base.
4
.
Remove the electronic subassembly
from the base.
5
.
Remove the battery from the
electronic
subassembly
.
6
.
I
nstal
l the new battery. Observe
polarity.
Note:
Install Panasonic
CR1632
.
7
.
Place the electronic sub assembly into
the base.
Note:
A generic diagram is
shown above. For diagrams showing
the wristband and
pendant
configurations, see the assembly
diagrams in the “
Installation
/
Pendant
”
section.
8
.
Inspect the
water seal area and the
plugs to ensure they are free from
debris.
9
.
Re
attach the cover
,
lanyard assembly
or wristband
and
the
base.
Note:
4
/
4
Personal Panic Device Installation Sheet
Press the pushbutt
on and cover
together before tigh
t
ening the screws.
10
.
T
est the help button
for proper
operation
.
11.
If the central monitoring station was
notified, inform them this operation is
complete.
Specifications
Model no.
TX
-
4200
-
01
-
1 (white)
TX
-
4200
-
01
-
2
(b
lack
)
RF frequency
319.5 MHz
Compatibility
Interlogix Learn Mode Panels
and Receivers
Battery type
3
.0
V
lithium (CR
1632
)
Recommended
b
attery
Panasonic CR1632
Typical
s
tandby
c
urrent (μA)
≤
1
Estimated
b
attery
l
ife
5
years
Supervisory
i
nterval
Less
than 64 minutes
Operating
t
emperature
r
ange
32° to 120°F (0° to 49°C)
Storage
temperature range
-
30 to 140°F (
-
34 to 60°C)
Relative humidity
5
-
90% non
-
condensing
Dimensions
(L x W x D)
1.
60
x
1
.
40
x 0.
410
in. (4.
1
x
3
.
6
x
1.0
cm)
Regulatory
Information
Manufacturer
UTC Fire & Security Americas
Corporation, Inc.
1275 Red Fox Rd., Arden Hills,
MN 55112
-
6943, USA
FCC
Compliance
This device complies with part 15
of the FCC Rules. Operation is
subject to the following two
conditions: (1) This device may
not cause harmful interference,
and (2) this device must accept
any interference received,
including interference that may
cause u
ndesired operation.
Changes or modifications not
expressly approved by Interlogix
can void the user’s authority to
operate the equipment.
FCC ID: B4Z
-
984
-
PANIC
IC: 1175C
-
984PANIC
This Class B digital apparatus
complies with Canadian ICES
-
003.
Cet appar
eil numérique de la
classe B est conforme à la norme
NMB
-
003 du Canada.
Le fonctionnement est soumis
aux deux conditions suivantes :
(1) cet appareil peut ne pas
provoquer d’interférences et (2)
cet appareil doit accepter toutes
interférences, y compris le
s
interférences pouvant
provoquer un fonctionnement
non désiré de l’appareil
.
US Patents
4,855,713; 4,864,636 and
others pending.
Contact
I
nformation
For general information, see
www.interlogix.com
. For customer
support,
see
www.interlogix.com/customer
-
support
or call +1 855 286 8889.
©
2014
United Technologies Corporation.
Interlogix is part of UTC Building and
I
ndustrial Systems, a unit of United
Technologies Corporation. All rights
reserved.
- Uploaded