L5200 Quick User Guide
Related Products
Related Categories
Document Transcript
Ê800-16089oŠ
800-16089 12/13 Rev A Part 1
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2013 Honeywell International Inc.
www.honeywell.com/security
LYNX Touch L5200
Rec or d a Message
Your system can record brief single or multiple messages. The total
available recording time is 184 seconds.
Function
Press
this
Icon…
Perform the following…
Record a
Message
Message
• Select “Add New” to Record a Message.
• Select “Record”.
• Select “Stop” when recording is complete.
Then select “”.
• The recorded message list is displayed.
Select the “” to return to the Security
Home Screen.
Play OR
Delete
Messages Message
• Select the Message that you wish to play
or delete.
• Select “Play” or “Delete All” as applicable.
• Select the “” to return to the Security
Home Screen.
Syst em Di spl ays
A "beeping" at the control, indicates a trouble condition in the system and
requires your attention. Determine if the zone(s) displayed are intact and
make them so if they are not. If the display persists, CALL FOR SERVICE.
Press any key to silence the beeping for these conditions.
The following icons will be displayed on the Home screen along with zone
status information (if applicable) indicating system status:
Icon Function Icon Function Icon Function
AC Loss
Door Open
Garage
Door Fault
Alarm
(intrusion)
Window
Open
WiFi source
present
Armed
Away
Exit Active
No WiFi
source
Armed
Stay
Fire OR
Heat
Sensor
94 Phone
Line Cut
Battery
Low
Flood
103 Comm.
Trouble
Check
Zones
Glass Break
90 RF Jam
CO Alarm
Medical
Alarm
Cover
Tamper
Disarmed
Not Ready
to Arm
Motion
Reporter
Failure
Disarmed
Ready to
Arm
Temperature
Automation
(Z-Wave
Failure)
See the full User Guide for additional details.
Ser vi c i ng I nf or mat i on
Your local Honeywell dealer is the person best qualified to service your
alarm system. Arranging some kind of regular service program with him
is advisable. Your local Honeywell dealer is:
Name:
Address:
Phone:
Set t i ng t he Dat e and Ti me
NOTE: The system must be disarmed before date/time can be set. You
can set the time and date by doing the following:
Date Time
• Use the “” or “” to select the correct month/year.
• Select the correct date. Use the “” to advance.
• Select “Clear” then enter the correct time
• Select AM/PM then select “Save” or use the “” to advance
• Select correct Time Zone
• Enable/disable Day Light Savings Time.
• If required select Day Light Saving Start/End Month/Week
• Select “Save”
Manual l y Cont r ol l i ng Home Aut omat i on Devi c es
Your system may be equipped Home Automation (Z-Wave) Devices.
These devices are normally controlled using programmed scenes but can
also be activated/controlled manually. To control home automation
devices manually, perform the following:
Mode
Press these Keys or
Icons…
What happens
Activating
Z-Wave
Devices
Automation
+
OR
68
OR
OR
OR
• You may be able to override
automatically controlled Z-
wave devices using the
Automation commands.
• Some devices can be manually
activated or deactivated using
the Automation commands.
• See your Installer for details
on controlling Z-Wave devices.
For additional information
regarding your system’s Home
Automation features refer to the
full version User Guide and to
the Home Automation Guide
(P/N 800-16091 or later).
Vi deo Camer a Cont r ol
Your system may be equipped to view and control video cameras. To
view video and/or control the camera, perform the following:
Video
• Select a camera from the displayed list.
• Control the camera as applicable using the displayed
controls.
For additional information regarding the video camera
control feature refer to the LYNX Touch L5200 User Guide
(P/N/ 800-16083 or later).
Connec t i ng a Mobi l e Devi c e (i OS)
Before attempting to connect your Mobile Device to the LYNX Touch
Control Panel, ensure that the LYNX Touch is connected to a WiFi Network
(router). Perform the steps below to connect up to four Mobile Devices to
the LYNX Touch control.
Connect your Mobile Device to the WiFi Network
1. Ensure that you have connected your Mobile Device to the same WiFi
Network as your LYNX Touch Control Panel. For additional information
refer to the LYNX Touch User Guide P/N 800-10615V1 (or higher).
Connect your Mobile Device to the LYNX Touch
1. At the LYNX Touch Master User screen, select the “Keypad” icon.
2. At the Mobile Device, select the “L5100 Connect” icon.
3. A Honeywell License and User Agreement is displayed. After reading
the agreement, select “Agree”. You must agree to the terms in order
to use the application.
4. “Discovering Control Panel…” is displayed.
5. Within 10-20 seconds the Device will display the Security Screen or
the Dashboard screen if Total Connect Services are enabled.
6. The control will display ID information for your Mobile Device.
7. Select the “” to return to the Master User Screen.
8. A Security Screen is displayed on your Mobile Device, which can now
be used to locally control your system.
LYNX TOUCH L5200 SERIES SECURITY SYSTEM
Quick Guide to User Functions
Full User Guide Available Online: This Quick Guide describes the most frequently used features and functions of your system. For full details of
all user functions, please see the system’s User Guide located online at: http://www.security.honeywell.com/hsc/products (see LYNX Touch
L5200 Security System User Guide P/N 800-16083 or higher). The full version User Guide is also available from your installer upon request.
Congratulations on your ownership of a Honeywell Security System. This system provides:
• Three forms of detection: burglary, fire and emergency (see your installer for which forms of detection are installed)
• At least one keypad which provides control of system and displays system status
• Various sensors for perimeter and interior burglary detection
• Optional smoke or combustion detectors designed to provide early warning in case of fire.
Your system may also be programmed to automatically send alarm and status messages to a Central Monitoring Station.
Syst em Basi c s
The following is a list of some of the most common features and
functions of your system:
• Several modes of burglary detection: Stay, Away, Instant.
• Bypass feature lets you bypass selected zones while leaving the
rest of the system armed.
• Chime mode alerts you to the opening of protected doors and
windows while the system is disarmed.
• Fire and carbon monoxide detection are always active (if
installed) and an alarm sounds if a fire or carbon monoxide
condition is detected.
• Panic keys (if programmed) let you manually initiate fire, police
and medical alarms using the keypad.
• 4-digit security codes are used in conjunction with keypad
commands to perform system functions.
• Each user (up to 32) can be assigned a different security code.
• The system sensing devices have been assigned to various
“zones,” which are specific areas of detection (e.g., front door,
kitchen window, etc.).
• Zone numbers (points of detection) are displayed at the keypad
when an alarm or trouble condition occurs.
• Message Center allows recording and play-back of brief voice
messages.
• Speaker Phone allows the control to be used for hands free
telephone conversation. See the full User Guide for details.
• Two-way Voice allows the Central Station to listen, talk or
conduct a two-way conversation with in individuals at the
premises. See the full User Guide for details.
• Follow me reminder announcements allow the panel to dial a
number and deliver system status messages. See the full User
Guide for details.
• A Scheduling feature can be programmed to automatically
perform certain functions (e.g., arm the system) at a
predetermined time each day. See the full User Guide for details.
Ent r y/Ex i t Del ays
• Entry Delays give you time to disarm the system when you
enter through the designated entrance door.
• You must disarm the system before the entry delay period ends,
or an alarm will occur (keypad beeps during the entry delay
period, reminding you to disarm the system).
• Exit delay gives you time after arming the system to leave
through the designated exit door(s) without setting off an alarm.
If programmed, a slow beeping will sound during the exit delay
period until the last 10 seconds, which then changes to fast
beeping (alerting you to the end of exit delay). If you cannot
leave within this delay time period, you should stop, disarm the
system, and start over to avoid a false alarm.
• See your installer for your delay times. See the full User Guide
for details on Exit Error alarms.
Not es on Bur gl ar y Det ec t i on
• The system must be armed before the burglary detection can
sense intrusions.
• To arm your system, select the desired arming key or icon and
enter your security code.
• To arm your system, if the Quick Arm feature is enabled select
the desired arming key or icon followed by the Quick Arm icon.
You do not need to enter your security code.
• To disarm the system, select the Disarm icon and enter your
security code.
• When an alarm occurs, the control sounds and displays the
zone(s) causing the alarm. An external sounder may also
sound, if installed.
• If your system is connected to a Central Monitoring Station, an
alarm message is also sent (delayed 30 seconds by default to
reduce false alarms).
• To stop the alarm sounding, simply disarm the system.
• Memory of Alarm: When an alarm condition occurs, the
keypad displays the number(s) of the zone(s) that caused the
problem, and displays the type of alarm. Clear the Memory of
Alarm display by entering another “off” sequence.
IMPORTANT
If you return to the premises and the burglary sounder is
on, or the keypad beeps rapidly upon entering the
premises, it indicates that an alarm has occurred during
your absence and an intruder may still be on the
premises. LEAVE IMMEDIATELY and CONTACT THE
POLICE from a nearby safe location.
Not es on Fi r e and CO Det ec t i on
• Your fire alarm system (if installed) is on 24 hours a day, for
continuous detection. In the event of an emergency, the
smoke and heat detectors sound their alarms, triggering a
loud, interrupted pulsed sound from the control and any
external sounder(s) (if installed).
• You can silence the alarm at any time by entering an Off
sequence.
• Carbon monoxide (CO) detectors, if installed, provide
continuous detection. If a high level of carbon monoxide is
detected, an interrupted pulsed alarm sound occurs at the
control and the detector(s). Immediately move to a spot
where fresh air is available, preferably outdoors. From a safe
area, call your security service provider for further
instructions. To silence the control sounding, enter an Off
sequence. To silence the detector, see its instructions.
Chec k i ng Syst em or Zone St at us/Bypassi ng Zones
Checking Zones: Before arming your system, all protected doors, windows and other detection
zones must be closed or bypassed; otherwise the keypad displays “Not Ready to Arm.”
Mode Press these icons… What happens
Check
System
Status System
• Displays system status.
Check
Zones
Zones
• Displays all faulted zones.
Select the “Zones” icon key when you want to arm your system with one or more zones
intentionally unprotected. The system must be disarmed first.
Mode Press this icon… What happens
Bypass
Zones
Zones
• When finished, the zones screen will be displayed along
with zone status.
• Arm the system as usual. When armed, the arming
message is displayed with “Bypass.”
• Bypassed zones are unprotected and will not cause an
alarm if violated.
• The system will not allow fire zones to be bypassed.
• Zones are automatically unbypassed when the system
is disarmed.
• To display bypassed zones prior to arming, select the
“Zones icon.
Zone St at us
The following icons will be displayed on the Zone Status screen along with zone status information
when a zone has been faulted, bypassed or is in alarm:
Display Definition Display Definition Display Definition
Alarm
Ready
Trouble (red)
Fault
(Yellow)
Bypass
Ar mi ng t he Syst em
Before arming, close all perimeter doors and windows and make sure the “Ready to Arm” message is
displayed. Select the specified icon or key and enter the 4-digit Security Code. The system will beep
three times to confirm the arming.
After arming, leave the premises through an entry/exit door during the exit delay period and be sure
the door is reclosed to avoid causing an alarm.
Mode
Press these keys or
icons…
When to use an arming mode and what happens
Stay
Arm Stay
• Used when you want to arm the system with persons
staying inside (or if you have pets that are moving
throughout the premises).
• Arms perimeter zones; interior zones left disarmed.
• An alarm sounds if any protected window or non-
entry/exit door is opened.
Instant
Stay
Instant tab +
Arm Stay
• Used when staying inside and you do not expect
anyone to use an entry/exit door.
• Same as Stay mode, except entry delay is off.
• An alarm sounds same as Stay mode, and sounds upon
opening entry/exit doors.
Away
Arm Away
• Used when nobody is staying inside (including pets).
• Arms the entire system (interior and perimeter).
• An alarm sounds if a protected window or any door is
opened, or if any movement is detected inside.
Quick
Arming
Arm Stay
OR
Arm Away
• If programmed, you can press the Quick Arm button
(when the keypad appears) in place of your security
code when arming the system.
Di sar mi ng t he Syst em and Si l enc i ng Al ar ms
The “Disarm” icon is used to disarm the system, silence alarm or trouble sounds, and clear memory
of alarm displays. Select the icon or key and enter the 4-digit Security Code.
Mode
Press these keys or
icons…
What happens
Disarm
and
Silence
Alarms
Disarm
• System is disarmed and alarm sounding is silenced.
• To clear the memory of alarm display (if present),
enter a second Off Sequence.
• To Silence a Fire Alarm or Carbon Monoxide , Simply
enter an “Off” sequence.
Pani c Keys
Your system may have been programmed to use special keys/icons to manually activate
emergency (panic) functions as follows:
To activate a Panic Function:
Press and hold down the Panic key for at least 2 seconds, then select the
Desired Panic function icon as indicated below:
Panic Function Icon Sends this Signal* With this Sounding…
Police Alarm
Police
Silent Alarm OR
Audible Alarm
No audible alarm; displays, “Not Ready to
Arm,” indicating that a silent alarm has
been initiated. OR
A loud, steady alarm at panel at external
siren (if installed); displays “Alarm 99
Police”
Medical Alarm
Medical
Auxiliary Alarm
Steady alarm sound at panel, but not at
external siren (if installed); displays “Alarm
96 Medical”
Fire Alarm
Fire
Fire Alarm
Temporal (pulsing) sound at panel and
external siren (if installed); displays “Fire
Alarm 95”
* All panic functions send signals to the Central Monitoring Station, if connected.
Test i ng t he Syst em
Using the Test mode allows each detection point to be checked for proper operation. Testing
should be conducted weekly to ensure proper operation.
• The keypad sounds a single beep about every 30 seconds as a reminder that the system is in the
Test mode. Alarm messages are not sent to your Central Station during testing.
If a problem is experienced with any detection point (no confirming sounds, no display), call for
service immediately.
1. Disarm the system and close all protected windows, doors, etc. The ready indicator LED should
be lit if all zones are intact.
2. At the Master Menu Screen Select the “Test” icon followed by the “Walk Test” icon.
3. Listen. The sounder should beep one time and “Walk Test-Off to Quit” should be displayed. The
control sounds a single beep every 30 seconds while the test is in progress. If the sounder
does not sound, CALL FOR SERVICE.
4. Fault zones. Open each protected door and window in turn and listen for three beeps from the
keypad followed by the zone’s voice descriptor. Each faulted detection point should appear on
the display. The display clears when the door or window is closed.
5. Walk in front of any interior motion detectors (if used) and listen for three beeps. Each detector
should appear on the display when it is activated. The display clears when no motion is detected.
Note that if wireless motion detectors are used, there is a 3-minute delay between activations to
conserve battery life.
6. Test all smoke detectors, following the manufacturer's instructions.
7. When all detection points have been checked and restored (closed), there should be no zone
numbers displayed.
8. Exit test mode by entering an Off Sequence.
Syst em Set t i ngs
Your system settings including volume level (message playback, system announcements, and
status beeps) and display brightness and contrast can be adjusted if desired. Additionally, you can
turn On/Off the Chime, Telephone Ringer and/or System Voice Announcements. A cleaning icon is
also available via the system settings.
Note: To enable or disable the Chime mode the system must be disarmed.
Mode
Press this Key or
Icon…
What happens
Voice
OR
Chime
OR
Ringer
Mode
Settings
+
Voice
OR
Chime
OR
Ringer
Voice
• Enables or disables the Voice announcement of
system status.
Chime
• Alerts you to the opening of a perimeter door or
window while the system is disarmed.
• Open (faulted) zone information is displayed.
• Three tones sound at the keypad whenever a
perimeter door or window is opened (faulted
interior zones do not produce a tone).
Ringer
• Enables or disables the Telephone Ringer.
Adjust
Brightness,
Contrast or
Volume
Settings
+
Brightness
OR
Contrast
OR
Volume
• Slide the button to Adjust the display brightness,
contrast or system volume.
Clean the
Touchscreen
Settings
+
Clean
• The touchscreen becomes inactive for 15 seconds
then returns to the settings screen and becomes
active.
Sec ur i t y Codes
Your installer assigned a Master Code that is used to perform all system functions. Security codes
can be assigned for up to 32 users. Only the Master User can assign security codes to users.
Tools
To Add/Edit/Delete User Codes:
Select the “Tools” icon on the second page of the Security Home Screen, then enter
your Master Code and follow the steps below:
Function Press this Icon… Perform the following…
Change
Master User
Code Users
• Select “Master”, then “Edit”
• Select “User Code”
• Enter a new 4-digit Master Code.
• Select “Done”, then “Save”.
Add Security
Code
Users
• Select “Add new”
• Select “Name”, then “Clear”
• Type a User Name, then “Done”
• Select “User Code”
• Enter a new 4-digit User Code.
• Select “Done”, then “Save”.
Edit/Delete
Security
Code Users
• Select “Name”, then select “Edit” or “Delete”
• Select “Name” or “User Code”
• Enter a new User Name OR 4-digit User Code.
• Select “Done”, then “Save”.
5200-100-002-V0
2 7
6
3
1
5 4
Index Item Description
1 Display
Window
Color Liquid Crystal Display (LCD) Touch screen. Displays system
status icons, time, system status information, user menus and the
virtual keypad.
2 Ready LED
Indicator
(Green)
ON = System is ready to be armed
OFF = System is armed
Blinking = System is disarmed, and not ready to be armed (a
fault exists)
Blinking alternately with Ready LED = Speaker phone mode active
3 Speaker Source of audible internal warning and confirmation sounds,
status announcements, as well as alarms (Refer to the full User
Guide for details).
4 Home key Used to exit from a screen or return to the home screen.
5 Panic key When depressed for 4 seconds, the virtual panic icons are
displayed on the touch screen.
6 Microphone Used to record personal messages via the Message Center, and
for two-way voice and speaker phone operation.
7 Armed LED
Indicator
(Red)
ON = System is armed (Stay or Away)
OFF = System is disarmed
Blinking = System armed, and an alarm or fault has occurred.
Blinking alternately with Ready LED = Speaker phone mode active
- Uploaded