L5210 Programming Guide



Related Products

Honeywell L5210 - LYNX Touch Wireless Security System with 4-1/3 inch Screen
Honeywell L5210
LYNX Touch Wireless Security System with 4-1/3 inch Screen

Related Categories


Document Transcript

LYNX Touch
L5210/L7000 Series
Security System
Programming Guide

800-19976

12/14 Rev. B

L5210/L7000

Table of Contents
Entering Programming Mode ....................................................................................................................................3
Programming the Data Fields ...................................................................................................................................3
Loading a Default Set ................................................................................................................................................3
Exiting Programming Mode .......................................................................................................................................3
Data Fields ................................................................................................................................................................4
Change Installer Code ...........................................................................................................................................4
Program System Type ...........................................................................................................................................4
Program Date and Time.........................................................................................................................................5
Program Communications .....................................................................................................................................6
Program Zones ......................................................................................................................................................7
Program Keys ........................................................................................................................................................8
Program Reporter ................................................................................................................................................10
Program Sounder.................................................................................................................................................15
Program System Settings ....................................................................................................................................16
Program the Z-Wave Module ...............................................................................................................................17
Communication Diagnostics ................................................................................................................................18
Zone Programming Worksheet ...............................................................................................................................20
Explanation of Zone Assignment Table Headings ...............................................................................................20
5800 Series Transmitter Loop Numbers Diagram...................................................................................................23
LYNX Touch L5210 Programming Default Values ..................................................................................................24
LYNX Touch L7000 Programming Default Values ..................................................................................................27
LYNX Touch Series Summary of Connections Diagram ........................................................................................31
Refer to the LYNX Touch Series Installation and Setup Guide P/N 800-19974 or later for detailed
information on programming the system. The Installation and Setup Guide contains full descriptions
for all data fields.

UL

LYNX Touch is not intended for UL985 Household Fire applications unless a 24-hour backup
battery (P/N LYNXRCHKIT-SHA) is installed.

-2-

Entering Programming Mode
You may find it convenient to adjust the volume setting before entering the Programming Mode. This
will allow you to clearly hear feedback announcements or system beeps.

1. Power-up the control and allow it to “boot-up”. “System Standby” is displayed on the touch screen. When the
“boot-up” is complete (approximately 1-2 minutes) “Ready to Arm” is displayed.
2. Select the “Security” icon.
3. Select the “More” tab on the first page of the Security Screen.
4. Select “Tools” icon.
5. Enter the Installer Code (4 + 1 + 1 + 2) on the displayed keypad.
5. The Installer Tools menu screen appears. Select the “Program” button. “System Programming…” is displayed
and the “Panic” button is lit and the “Home” button alternately flashes red and green.
6. Select one of the following options to advance to that Programming screen:
Installer Code
Date Time
Zones
Keys

System Type
Communicator
Comm. Diagnostics
Reporter

Use the down arrow to scroll to the next page of options.

Sounder
Default Config.
Reset Master Code

System Settings
Z-Wave

Note: If a different Installer Code has been programmed, enter: the New Installer Code.

Programming the Data Fields
1. Select each desired programming option, and then select the required entry. The system beeps each time a
selection is made.
2. The system will toggle or scroll through the options or display a new screen as applicable for the specific
option.
3. To delete or change an entry, simply select the desired option, and then select the required entry.

Loading a Default Set:
1. Enter the Installer Programming Mode and advance to second page of the System Programming.
2. Select ‘Default Config’ and select the appropriate Default Configuration from the following options or Select
Default Downloader to reset all subscriber account numbers and CSID in preparation for an initial download:
Default Config 1
Default Config 2
Default Config 3
Default Config 4
Default Downloader

Note: Refer to the Programming Default Values section of this manual to view the default values.

Exiting Programming Mode:
1. Select the “” key to exit the current screen. The system returns to the previous screen.
2. Select the “” key as required until system displays a Confirmation screen.
3. Select “Yes” to allow the installer to re-enter Programming mode or “No” to prevent re-entry.
4. Select the “” key again to return to the Security Screen OR depress the Home button to return to the Home
Screen.

-3-

Screen Display

Function & Programming Options

DATA FIELDS
Note: Preprogrammed defaults are shown on the screen display.

Change Installer Code
Installer Code

Installer Code
5000-100-129-V0

Enter 4 digits [The defaulted Installer Code is 4112]
0-9

Program System Type
RF Jam
Disabled
Speaker Phone
Disabled

Two Way Voice
Disabled
RF House Code
0
Remote Phone
Enabled

Phone Notification
Disabled

RF Jam
Disabled
RF Jam Log
RF Jam Log & Report
Note: The Speaker Phone feature is not available on the LYNX Touch L7000.
Speaker Phone
Disabled
Enabled
Two-Way Voice
Disabled
Enabled
RF House Code
Enter 2 digits, 00-31
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Remote Phone
Disabled
Enabled
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Phone Notification
Disabled
Keypad
Trouble
Note:

Phone Detect Time
2 Minutes

Events - Log All
Log All Set

Events – Log Alarm
Enabled
Events – Log Bypass
Enabled
Events – Log Open Close
Enabled

If “Keypad” or “Trouble” is selected you will be prompted to program a phone detect time.

Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Phone Detect Time
1 Minute
2 Minutes
3 Minutes
4 Minutes
Events – Log All
Note: If Press to Log All is selected the system will log the following events:

Alarm
Bypass
Open/Close
Trouble
Non-Security
Events – Log Alarm
Enabled
Disabled
Events – Log Bypass
Enabled
Disabled
Events - Log Open/Close
Enabled
Disabled

-4-

Screen Display
Events – Log Trouble
Enabled

Function & Programming Options
Events – Log Trouble
Enabled
Disabled
Non Security
Enabled
Disabled

Non Security
Enabled
Remote Access Serial
Disabled

Remote Access Serial
Enabled
Disabled
Note: If the “Remote Access Serial” option is enabled, you will be prompted to select a “Multi Mode
Serial”.

Multi Mode Serial
Disabled

Multi Mode Serial
Enhanced Reports
Disabled

Program Date and Time
Date Time

Date Time
5000-100-131-V0

Note: If you are installing a 4GL/4GLC or 3GL/3GLC, L5100-WiFi or ILP5 Communication Module, the
time and date will be programmed and updated automatically via Central Station. You must still
program the correct Time Zone below.

1.
2.
3.
4.
5.
Time Zone
Eastern (EST)

Day Light Savings Time
Yes

Start Month
March

Start Week
Second

End Month
November

Month and Year
Select the correct date
Enter the correct time
Select AM or PM
Select Save or continue below.

Time Zone
Eastern (EST)
Central (CST)
Hawaii (HAST)
Mountain (MST)

Pacific (PST)
Alaska (AKST)
Brasilia (BRT)
Mid-Atlantic (MAT)

Atlantic (AST)
Newfoundland (NT)

Day Light Savings Time
Yes
No
Note: If Yes is selected, the following options will be active.
Start Month
January
February
March
April
May
June

July
August
September
October
November
December

Start Week
First
Second
Third
Fourth
Last
Next to Last
3rd from Last
End Month
January
February
March
April
May
June

July
August
September
October
November
December

-5-

Screen Display

Function & Programming Options
Start Week
First
Second
Third
Fourth
Last
Next to Last
3rd from Last

End Week
First

Program Communications
Communicator
5000-100-132-V0

Communications Path
None

APL
Disabled
City ID

CS ID

Sub ID

Supervision
24 Hours

Old Alarm Time
10 Minutes

Remote Acc. Comm.
Disabled

Communicator
Program the following options:
Communications Path
City ID
CS ID
Supervision
Remote Acc. Comm.
GSM Fault Time OR
IP Fault Time

APL
Sub ID
Old Alarm Time
Multi Mode Comm.

Communications Path
None
IP
GSM
WiFi
WiFi & GSM
Advanced Protection Logic
Enabled
Disabled
Primary City Identification
Enter 2 digits
01-99
Primary Central Station Identification
Enter 2-digits (HEX)
01-FE
Primary Subscriber Identification
Enter 4-digits
0001-9999
Supervision
24 Hours
None
30 Days
Old Alarm Time
10 Minutes
30 Minutes
2 Hours
8 Hours
24 Hours

15 Minutes
1 Hour
4 Hours
12 Hours

Remote Access Communication
Disabled
Enabled
Note: If enabled the following option will be active.

Multi Mode Comm.
Disabled

GSM Fault Time (min)
00

Multi Mode Communication
Disabled
Relay Reports
Enhanced Reports
GSM Fault Time (min) (displayed if GSM is selected as Communications Path)
Enter 2-digits
00-99

-6-

Screen Display
IP Fault Time (min)

Function & Programming Options
IP Fault Time (min) (displayed if IP or WiFi is selected as Communications Path)
Enter 2-digits
00-99

00

Use DHCP
Yes
No

Use DHCP
Yes

Note: If disabled the following options will be active.

NIC IP Address
255.255.255.255

NIC IP Address (Appears only if “no” was selected in the “Use DHCP Field”)
Enter 4 part address
Subnet Mask (Appears only if “no” was selected in the “Use DHCP Field”)

Subnet Mask
255.255.255.255
Gateway IP Address
255.255.255.255
DNS Server IP Address
255.255.255.255

Enter 4 part address
Gateway IP Address (Appears only if “no” was selected in the “Use DHCP Field”)
Enter 4 part address
DNS Server Address (Appears only if “no” was selected in the “Use DHCP Field”)
Enter 4 part address
GSM Rollover (Appears only if “WiFi and GSM” was selected in the “Communications Path”
field)
Yes
No

GSM Rollover
No

GSM 24 Hour Test
No

GSM 24 Hour Test (Appears only if “WiFi and GSM” was selected in the “Communications
Path” field)
Yes
No

Program Zones
Zones
5000-100-133-V0

Zones
Select from the following zone options:
1. New
2. Front Door
3. Back Door
4. Window
5. Motion Sensor
6. New
7. – 45. New
Zones 46 to 48 are reserved for Garage Door Zones (L5210)
46. – 48. New (Main)* Garage
Zones 45 to 48 are reserved for Garage Door Zones (L7000)
45. – 48. New (Main)* Garage
Zones 49 to 64 (L5210)
49. – 64. New
Zones 49 to 80 (L7000)
49. – 80. New
Zones 140 to 147 (L5210 and L7000)
140. – 147. 4 Button
Zones 148 to 155 (L5210 Only)
148. – 155. New (Button Zones)
Z-Wave Thermostat zones (L5210)
180. – 185. Temperature
Z-Wave Thermostat zones (L7000)
180. – 187. Temperature
95. Fire
96. Medical
99. Police
Select a zone and then select “Edit” or “Add New” to program the next available zone.
Program the following options:(dependent upon Zone Type):
Serial Number
Loop Number
Zone Description 1
Zone Description 2
Device Type
Response Type
Report
Chime
Supervision

-7-

Screen Display
Serial Number

Function & Programming Options
Serial Number
When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed.
The transmitter serial number and loop number can be enrolled via RF transmission OR
manually.
Enroll via RF Learning To enroll the device using RF Learning mode three transmissions
(open/close) of the device will be required. The initial transmission activates the RF
Learning mode and the system will emit a single beep. A second transmission enrolls the
serial number and the system beeps two times and displays “Activate Sensor Again To
Confirm”. A third transmission will confirm the serial number. The system beeps two times
and returns to the Zone programming Screen.
Enroll Manually
Enter the 7-digit serial number printed on the transmitter using the displayed keypad and
select “Done”. The system beeps one time and returns to the Zone programming Screen

Loop Number
1
Zone Description 1

Zone Description 2

Device Type

Response Type
Not Used

Report
Yes
Chime
Disabled

Supervision
Supervised

Arm Night
No

Loop Number
1, 2, 3 or 4
Zone Description 1
The system announces the Zone Description. If desired, enter a zone descriptor.
Zone Description 2
The system announces the Zone Description. If desired, enter a zone descriptor.

Device Type
Choose from the following options (dependant upon the Zone):
New
Door
Window
Motion Sensor
Glass Break
Smoke Detector
Heat Sensor
Carbon Mono. Det.
Temperature
Flood
Environmental
Medical
Fire
Police
Garage Door
Other
Response Type
Choose from the following options (dependant upon the Device Type):
Not Used
Arm Stay
Fire No Verification
Entry Exit 1
Disarm
Monitor
Entry Exit 2
Silent Burglary
Garage
Interior Follower
Resident Response
Arm Away
24 Hour Silent
General Response
No Response
24 Hour Auxiliary
Perimeter
Resident Monitor
Interior With Delay
Day Night
General Monitor
Carbon Monoxide
24 Hour Audible
Fire With Verification
Garage Monitor
Trouble
Report
Yes
No
Chime
Disabled
Standard
Melody
Melody Long
Supervision
Hardwire Zone
Normal Open
Normal Closed
End of Line

Ascend
Ascend Long
Alert 1
Alert 2
RF Zone
Supervised
Unsupervised

Doorbell 1
Doorbell 2
Evolve

Temperature
High Temp
Low Temp

Arm Night (This option is only available if “Motion Sensor” is selected in the “Response Type” field.)
Yes
No

-8-

Screen Display

Function & Programming Options

Program Keys
Keys

Keys
Select from the following options:
Edit

Add New

Delete

If add new is selected the following options can be programmed:

Key Type
4 Button Key

User

Key Type
Serial Number
Button Key 1 – Zn 140
Button Key 3 – Zn 142
Button Key 5 – Zn 144
Button Key 7 – Zn 146
Key Type
1 Button Key.
2 Button Key
4 Button Key
6 Button Key
8 Button Key
User
Master
Duress
Guest
User 3 through User 30 (L5210)
User 3 through User 46 (L7000)

User
Zone
Button Key 2 – Zn 141
Button Key 4 – Zn 143
Button Key 6 – Zn 145
Button Key 8 – Zn 147

Note: The Key must be associated with a specific User/User Code in order for it to operate. Refer to the
LYNX Touch Series User Guide for additional Information regarding User Codes.

Serial Number
0

Serial Number
When “Serial Number” has been selected “Enter Serial Number or Activate” is displayed.
The transmitter serial number and loop number can be enrolled via RF transmission OR
manually.
Enroll via RF Learning To enroll the device using RF Learning mode three transmissions
(open/close) of the device will be required. The initial transmission activates the RF
Learning mode. A second transmission enrolls the serial number and the system beeps two
times and displays “Activate Sensor Again To Confirm”. A third transmission will confirm the
serial number. The system beeps two times and returns to the Zone programming Screen.
Enroll Manually
Enter the 7-digit serial number printed on the transmitter using the displayed keypad and
select “Done”. The system beeps one time and returns to the Zone programming Screen

Zone
140
Button Key * - Zone *

Zone
Manually enter a specific two-digit Zone Number (140-155 L5210 OR 140-163 L7000).
Button Key * Zn *
Enter a function for each button key from the following options:
Disarm
Arm Away
Arm Stay
No Response
24 Hour Silent
24 Hour Audible
24 Hour Auxiliary
Silent Burglary
Fire No Verification
* Options are the same for each Button/Zone combination.

-9-

Screen Display

Function & Programming Options

Program Reporter
Reporter

Primary CS Info

Phone Type
Contact Id: 4 Digit

Reporter
Note: The Follow Me Phone features are not available on the LYNX Touch L7000.
Program the following options:
Primary CS Info
Secondary CS Info
Follow Me Phone 1
Follow Me Phone 2
Report Selection
Options
Downloader
Primary Central Station Information
Phone Type
Communicator Type
Phone Type
None
Contact Id : 4 Digit
Contact Id : 10 Digit
SIA
Note:

Communicator Type
None

If SIA, Contact Id: 4 Digit, or Contact Id: 10 Digit is selected the Phone Number and Account
Number options will be displayed.

Communicator Type
None
GSM
WiFi
WiFi & GSM
IP
Note: If IP is selected the Dynamic Priority option will be displayed.

Phone Number

Account Number
FFFF
Dynamic Priority

Phone Number
Enter the Primary Central Station Phone Number (Up to 20 digits)
Account Number
Enter the Primary Central Station Account Number
Dynamic Priority
Redundant Reports
Preferred Telco
Preferred Radio
Note:

Dynamic Delay

Report All
Press to Report All
Report Alarms
Enabled
Report Troubles
Enabled
Report Open/Close
Disabled
Report Tests
Enabled

If Preferred Telco or Preferred Radio is selected the Dynamic Delay option will be displayed.

Dynamic Delay
15 Seconds
30 Seconds
60 Seconds
90 Seconds
Report All
Press to Report All
Report All Set
Report Alarms
Disabled
Enabled
Report Troubles
Disabled
Enabled
Report Open/Close
Disabled
Enabled
Report Tests
Always Enabled (not selectable)

- 10 -

Screen Display
Secondary CS Info

Phone Type
None

Function & Programming Options
Secondary Central Station Information
Phone Type
Communicator Type
Phone Type
None
Contact Id: 4 Digit
Contact Id: 10 Digit
SIA
Note: If SIA, Contact Id: 4 Digit or Contact Id: 10 Digit is selected, the Phone Number and Account
Number options will be displayed.

Communicator Type
None

Communicator Type
None
GSM
WiFi
WiFi & GSM
IP
Note: If IP is selected the Dynamic Priority option will be displayed.

Phone Number

Account Number
FFFF
Dynamic Priority
None

Phone Number
Enter the Secondary Central Station Phone Number (Up to 20 digits)
Account Number
Enter the Secondary Central Station Account Number
Dynamic Priority
Redundant Reports
Preferred Telco
Preferred Radio
Note: If Preferred Telco or Preferred Radio is selected the Dynamic Delay option will be displayed.

Dynamic Delay
None

Report All
Press to Report All
Report Alarms
Enabled
Report Troubles
Enabled
Report Open/Close
Disabled
Report Tests
Enabled
Follow Me Phone 1

Dynamic Delay
None
15 Seconds
30 Seconds
60 Seconds
90 Seconds
Report All
Press to Report All
Report All Set
Report Alarms
Disabled
Enabled
Report Troubles
Disabled
Enabled
Report Open/Close
Disabled
Enabled
Report Tests
Always Enabled (not selectable)
Follow Me Phone 1 (This feature is not available on the LYNX Touch L7000)
Choose from the following options:
Phone Type
Phone Number
Report All
Report Alarms
Report Troubles
Report Open/Close
Report Tests

- 11 -

Screen Display
Phone Type
None

Phone Number
None
Report All
Press to Report All
Report Alarms
Disabled
Report Troubles
Disabled
Report Open/Close
Disabled
Report Tests
Disabled

Follow Me Phone 2

Phone Type
None
Phone Number

Report All
Press to Report All
Report Alarms
Disabled
Report Troubles
Disabled
Report Open/Close
Disabled
Report Tests
Disabled

Function & Programming Options
Phone Type (This feature is not available on the LYNX Touch L7000)
None
Follow Me
(If Follow Me is selected several new options will be displayed)
Phone Number (This feature is not available on the LYNX Touch L7000)
Enter the Follow Me Phone Number
Report All (This feature is not available on the LYNX Touch L7000)
Press to Report All
Report All Set
Report Alarms (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Troubles (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Open/Close (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Tests (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Follow Me Phone 2 (This feature is not available on the LYNX Touch L7000)
Choose from the following options:
Phone Type
Phone Number
Report All
Report Alarms
Report Troubles
Report Open/Close
Report Tests
Phone Type (This feature is not available on the LYNX Touch L7000)
None
Follow Me
Phone Number (This feature is not available on the LYNX Touch L7000)
Enter the Follow Me Phone Number
Report All (This feature is not available on the LYNX Touch L7000)
Press to Report All
Report All Set
Report Alarms (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Troubles (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Open/Close (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled
Report Tests (This feature is not available on the LYNX Touch L7000)
Disabled
Enabled

- 12 -

Screen Display
Report Selection

Arm Away
Enabled
Arm Stay
Enabled
Disarm
Enabled
Exit Error
Enabled
Recent Closing
Enabled
Event Log Full
Enabled
Trouble
Enabled
Trouble Restore
Enabled
Alarm Restore
Enabled
Alarm Cancel
Enabled
Test
Enabled
Test Restore
Enabled
Bypass
Enabled
Bypass Restore
Enabled
AC Loss
Enabled
AC Loss Restore
Enabled

Function & Programming Options
Report Selection
Choose from the following options:
Arm Away
Arm Stay
Disarm
Exit Error
Recent Closing
Event Log Full
Trouble
Trouble Restore
Alarm Restore
Alarm Cancel
Test
Test Restore
Arm Away
Disabled
Enabled
Arm Stay
Disabled
Enabled
Disarm
Disabled
Enabled
Exit Error
Always Enabled (not selectable)
Recent Closing
Always Enabled (not selectable)
Event Log Full
Disabled
Enabled
Trouble
Disabled
Enabled
Trouble Restore
Disabled
Enabled
Alarm Restore
Disabled
Enabled
Alarm Cancel
Disabled
Enabled
Test
Always Enabled (not selectable)
Test Restore
Always Enabled (not selectable)
Bypass
Disabled
Enabled
Bypass Restore
Disabled
Enabled
AC Loss
Disabled
Enabled
AC loss Restore
Disabled
Enabled

- 13 -

Bypass
AC Loss
Low Battery
RF Low Battery

Bypass Restore
AC Loss Restore
Low Battery Restore
RF Low Battery Restore

Screen Display
Low Battery
Enabled
Low Battery Restore
Enabled
RF Low Battery
Enabled
RF Low Battery Restore
Enabled
Options

PBX

Call Wait Cancel

Number of Reports
2 Reports

Alarm Report Delay
30 Sec.

First Report Offset
6 Hrs

Report Frequency
Never

Function & Programming Options
Low Battery Restore
Disabled
Enabled
Low Battery Restore
Disabled
Enabled
RF Low Battery
Disabled
Enabled
RF Low Battery Restore
Disabled
Enabled
Options
Choose from the following options:
PBX
Call Wait Cancel
Number of Reports
Alarm Report Delay
First Report Offset
Report Frequency
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
PBX
Enter PBX Prefix
Call Wait Cancel
Enter Call Wait Cancel Prefix
Number of Reports
1 Report
2 Reports
3 Reports
4 Reports
5 Reports
6 Reports
Alarm Report Delay
15 Sec.
30 Sec.
45 Sec.
No delay
First Report Offset
6 Hrs
12 Hrs
18 Hrs
24 Hrs
Report Frequency
Never
Every Day
Every 7 Days
Every 30 Days

Downloader
Downloader

Phone Answer
Yes

Choose from the following options:
Phone Answer
Modem Speed
Ans. Machine Defeat
Callback Number
Ring Counter
Flexible Callback
Number
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Phone Answer
Yes
No

- 14 -

Screen Display
Modem Speed
Slow
Ans. Machine Defeat
Yes

Function & Programming Options
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Modem Speed
(Future Use)
Note: The Remote Phone feature is not available on the LYNX Touch L7000.
Answering Machine Defeat
Yes
No
(If No is selected the Ring Counter Option will be displayed.)

Ring Counter
2

Ring Counter (displayed if Ans. Machine Defeat is set to “No”)
Enter ring counter (1-14)

Callback Number

Callback Number
Enter a Callback Number

Flexible Callback

Flexible Callback
Yes
No

No

(If Yes is selected the Number Option will be displayed.)

Number

Number (displayed if Flexible Callback is set to “Yes”)
Enter the number of flexible callbacks that will be used (1-3)

Program Sounder
Sounder
Sounder

Burglary Alarm Sound
Yes
Burglary Bell Timeout
4 Minutes

Fire Bell Timeout
4 Minutes

Arm Confirm
RF Keyfob

Choose from the following options:
Burglary Alarm Sound
Burglary Bell Timeout
Fire Bell Timeout
Arm Confirm

Burglary Alarm Sound
Yes (Full volume)
No (Test volume – installer mode)

Burglary Bell Timeout
No
4 Minutes
8 Minutes
12 Minutes
16 Minutes

Fire Bell Timeout
No
4 Minutes
8 Minutes
12 Minutes
16 Minutes

Arm Confirm
None
All RF
RF Key Fob
RF Keypad

- 15 -

Screen Display

Function & Programming Options

Program System Settings
System Settings
System Settings

Entry Delay 1
30 Seconds

Entry Delay 2
30 Seconds

Exit Delay
60 Seconds

Backlight Timeout

Choose from the following options:
Entry Delay 1
Entry Delay 1
Exit Delay
Backlight Timeout
Quick Arm
Quick Exit
Restart Exit Time
Force Bypass Exit Warning
Auto Stay Arming
Lack of Usage Notify
Power-up in Previous
Display Alarm Cancel
Display Exit Time
Cross Zone Delay
Cross Zone 1
Cross Zone 2

Entry Delay 1
None
15 Seconds
30 Seconds
45 Seconds
60Seconds
90 Seconds
2 Minutes
3 Minutes
4 Minutes

Entry Delay 2
None
15 Seconds
30 Seconds
45 Seconds
60Seconds
90 Seconds
2 Minutes
3 Minutes
4 Minutes

Exit Delay
45 Seconds
60 Seconds
90 Seconds
2 Minutes

Backlight Timeout

No

No
30 Seconds

Quick Arm

Quick Arm

Yes
Quick Exit
Yes
Restart Exit Time
Yes
Force Bypass
No
Exit Warning
Yes
Auto Stay Arming
Yes

Yes
No

Quick Exit
Yes
No

Restart Exit Time
Yes
No

Force Bypass
Yes
No

Exit Warning
Always Enabled (not selectable)

Auto Stay Arming
Yes
No

- 16 -

Screen Display
Lack of Usage Notify
Disabled

Power-Up in Previous
Yes
Display Alarm Cancel
Yes
Display Exit Time
Yes
Cross Zone Delay
None

Function & Programming Options
Lack of Usage Notify
Disabled
1 Day
7 Days
27 Days
90 Days
180 Days
365 Days

Power-Up in Previous State
Always Enabled (not selectable)

Display Alarm Cancel
Yes
No

Display Exit Time
Yes
No

Cross Zone Delay
None
30 Seconds
1 Minute
90 Seconds
2 Minutes
3 Minutes
4 Minutes

Cross Zone 1

Cross Zone 1

Disabled

Disabled

Cross Zone 2

Cross Zone 2

Disabled

Disabled

Program the Z-Wave Module
Z-Wave

Z - Wave
5100-100-067-V0

Z-Wave
Enabled-Installed Telephone

Temperature Display
Fahrenheit

Note: This procedure must be completed any time that the panel has been defaulted or
updated.
Z-Wave
Select from the following options:
Enabled – Installed Telephone Side
Disabled
Temperature Display
Select from the following options:
Fahrenheit
Celsius

- 17 -

Communications Diagnostics
Note: For additional information regarding these fields, refer to the LYNX Touch Installation and Setup Guide P/N 800-19974
or higher.

Comm. Diagnostics

Communication Diagnostics
Choose from the following options (depending upon the Communication Module that is
installed:
Communication
Status
Communication
ID Numbers
WiFi Location

Ethernet
Information
Test
Communication
WiFi Status

GSM
Information
Setup
Communication
Configure
WiFi

Communication Status - Provides a status of the IP or Cellular communications paths and performs a self-test of the
advanced encryption standard (AES) algorithm.
Message Function
GSM OR IP: Displays Network Connectivity status
Encryption: Displays result of encryption test (Pass or Fail)
AlarmNet Registration: Displays Account Registration status
Ethernet Information - Displays IP information if the IP Communication Path is enabled.
Message Function
Physical Link: Confirms physical link connection and speed
DHCP: Displays status of server
NIC IP Address: Displays the communication device’s assigned IP address
Subnet Mask:
Gateway IP Address:
DNS Server IP Address:

Displays the 32-bit address mask used to indicate the portion (bits) of the
IP address that is being used for the subnet address
Displays the IP address assigned to the Gateway
Displays the IP address assigned to the DNS server

GSM Information - Displays GSM information if the GSM communication path is enabled and the device is registered.
Message Function
Cell Registration: Displays registration status
Primary RSSI: Displays primary site RSSI signal strength (1 to 5 stars)
GPRS:
Displays availability of GPRS service.
(2G only, always available in 3G/4G)
Country: Displays country code
Network: Displays network code
LAC: Displays local area code
Cell: Displays base station ID (4-digit in 2G or 6-digit in 3G/4G)
Base Station: (2G only) Displays Base Station Antenna Sector
Pri Sync Code: (3G/4G only) Displays primary sync code
Channel: Displays control in use
Second Site RSSI: Displays presence of Secondary site RSSI level availability
If the GSM is not registered the following may be displayed:
Searching for Coverage! Searching for cell network
SIM Error! No SIM card present of SIM card faulty
Cell Registration: SIM Not Active SIM is not activated
Cell Registration: Not Registered Not registered with the cell network
Communication ID Numbers- Displays programmed SIM card information for the installed communication module.
Message Function
MAC: Displays MAC address
MAC CRC: Displays MAC CRC number
SCID: Displays SIM card identification number
IMEI: Displays communication module identity number
WiFi* Displays physical address of the WiFi module
WiFi Ver* Displays WiFi Module software version
* If applicable

- 18 -

Communications Diagnostics
Test Communication - Performs network diagnostics and sends test alarms to the network. The following tests are
available depending on the type of communications module installed.
Message Function
Send Cellular Message: Available if Cellular communication path is enabled
Test Ethernet: Available if IP or WiFi communication path is enabled
Send Ethernet Message: Available if IP or WiFi communication path is enabled
Send Any: Available if IP or WiFi and Cellular communication path is enabled
Setup Communication – Registers the LYNX Touch and its associated communication module, update configuration files
or reset factory defaults.
Selection Function
Download Config File: The device configuration file will be downloaded
Register Device: Registers the module with AlarmNet
Register Device With PIN: Used enter PIN when replacing one module with another
Update Server: The communication device uploads its configuration to the server
Factory Defaults: The communication device is reset to factory default values
WiFi Stats – Displays WiFi Specific Diagnostics information (Not intended for Installer use)

- 19 -

Zone Programming Worksheet
Fill in the required data on this worksheet, then follow the programming procedure. (The defaults shown are for
Configuration 1)
See Explanation of Zone Assignment Table Headings
Note: Zones 65-70, 156-163, and 186-187 are only available on the LYNX Touch L7000 control.
Zone
No.
1

Loop
No.
N/A

Device
Type
New

Chime

Supervision

Not Used

Alarm
Report
Yes

Disabled

End of Line

Door

Entry Exit 1

Yes

Standard

Supervised

Arm
Night
N/A
N/A

2

2

3

2

Door

Entry Exit 1

Yes

Standard

Supervised

N/A

N/A
N/A

Response Type

4

2

Window

Perimeter

Yes

Standard

Supervised

N/A

5

1

Motion Sensor

Interior with Delay

Yes

Disabled

Supervised

No

6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42

- 20 -

Transmitter
Serial Number
N/A

Zone
Descriptor
(HW Zone)
Front
Back

Zone Programming Worksheet
Loop
No.

Device
Type

Response
Type

Report

Chime

Supervision

Arm
Night

45

1

New

Not Used

No

Standard

Supervised

N/A

Main

46

1

New

Not Used

No

Standard

Supervised

N/A

Main
Main
Main

Zone
No.
43

Transmitter
Serial Number

Zone
Descriptor

44

47

1

New

Not Used

No

Standard

Supervised

N/A

48

1

New

Not Used

No

Standard

Supervised

N/A

3

4 Button

Arm Away

No

Disabled

Button

N/A

N/A

N/A

N/A

N/A

49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
140
141

2

4 Button

Disarm

No

Disabled

Button

N/A

142

4

4 Button

Arm Stay

No

Disabled

Button

N/A

N/A

N/A

N/A

N/A

143

1

4 Button

No Response

No

Disabled

Button

N/A

144

3

4 Button

Arm Away

No

Disabled

Button

N/A

N/A

N/A

N/A

N/A

145

2

4 Button

Disarm

No

Disabled

Button

N/A

146

4

4 Button

Arm Stay

No

Disabled

Button

N/A

N/A

N/A

147

1

4 Button

No Response

No

Disabled

Button

N/A

N/A

N/A

- 21 -

Zone Programming Worksheet
Zone
No.
148

Loop
No.

Device
Type

Response
Type

N/A

Temperature

Report

Chime

Supervision

Arm
Night

Transmitter
Serial Number

Yes

Disabled

High Temp

N/A

N/A

Yes

Disabled

Low Temp

N/A

N/A

Yes

Disabled

High Temp

N/A

N/A
N/A

Zone
Descriptor

149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
180
181

N/A

Temperature

Monitor
Monitor

182

N/A

Temperature

Monitor

183

N/A

Temperature

Monitor

Yes

Disabled

Low Temp

N/A

184

N/A

Temperature

Monitor

Yes

Disabled

High Temp

N/A

N/A

185

N/A

Temperature

Monitor

Yes

Disabled

Low Temp

N/A

N/A

186

N/A

Temperature

Monitor

Yes

Disabled

High Temp

N/A

N/A

187

N/A

Temperature

Monitor

Yes

Disabled

Low Temp

N/A

N/A

95

N/A

Fire

Fire No Verif.

Yes

Disabled

Panic Trigger

N/A

96

N/A

Medical

Not Used

Yes

Disabled

Panic Trigger

N/A

99

N/A

Police

24 Hour Silent

Yes

Disabled

Panic Trigger

N/A

Explanation of Zone Assignment Table Headings
Loop Number - Used with 5800 Devices. Record transmitter loop number. Entries are 1-4, depending on device being used.
Refer to the transmitter’s instructions or the figure provided for appropriate loop numbers.
Device Type- Dependent upon the Zone Number being programmed.
Door
Window
Motion Sensor
Glass Break

Smoke Detector
Heat Sensor
Carbon Mono. Det.
Temperature

Flood
Environmental
Medical
Police

Fire
Garage Door
Other

Response Type - Dependent upon the Device Type that has been selected.
Entry Exit 1
Entry Exit 2
Perimeter
Interior Follower
Day/Night
24 Hour Silent
Garage Monitor

24 Hour Audible
24 Hour Auxiliary
Fire No Verification
Interior with Delay
Monitor
Carbon Monoxide

Trouble
Arm Stay
Arm Away
Disarm
No Response
Silent Burglary

Resident Monitor
Resident Response
General Monitor
General Response
Fire With Verification
Garage

Supervision - Dependent upon the Zone Number being programmed.
Hardwire Zone
(Zone 1)
End of Line (Resistor)
Normal-Closed
Normal-Open

Wireless Zone
(Zone 2-64 L5210)
(Zone 2-80 L7000)
Supervised
Unsupervised

Key
(Zone 140-155 L5210)
(Zone 140-163 L7000)
Button

- 22 -

Temperature
(Zone 180-185 L5210)
(Zone 180-187 L7000)
High Temp
Low Temp

5800 Series Transmitter Loop Numbers
LOOP
1
LOOP 1
LOOP
1

LOOP 1
(LOW
SENSITIVITY

LOOP 1
(LOW
SENSITIVITY

LOOP 2
(HIGH
SENSITIVITY)

LOOP 2
(HIGH
SENSITIVITY)

LOOP 3 (TEMP)

LOOP 3 (TEMP)
LOOP 4 (TAMPER)

LOOP 4 (TAMPER)
5800PIR-RES
ENROLL AS "RF"

LOOP 3
LOOP 4

OF
F

LOOP 1

LOOP
3

5 8 0 0 WAV E
P RO G R A M
HOUSE ID

5804E
ENROLL AS "BR"

LOOP 2
(REED)

5 8 0 4 B D / 5 8 0 4 B DV
ENROLL AS "BR"
PROGRAM HOUSE ID

LOOP 1

5816MN
ENROLL AS "RF"

5818MNL
ENROLL AS "RF"

Y

MIC

SERIAL #2
LOOP 4

ME

SSAG

E

SERIAL #1
LOOP 4
SERIAL #2
LOOP 2
5822T
ENROLL AS "RF"

5828/5828V
P RO G R A M
HOUSE ID

LOOP 1
(HIGH
SECURITY)

5834-2
ENROLL AS "BR"

SERIAL #1
LOOP 3
AW
AY

SERIAL #1
LOOP 4

LOOP 2
(STANDARD
SECURITY)

SERIAL #1
LOOP 2

1
2

SERIAL #2
LOOP 3

LOOP 3 (TILT MODE)

3
4

SERIAL #1
LOOP 1

SERIAL #1
LOOP 1

5834-4
ENROLL AS "BR"

5853
ENROLL AS "RF"

5869
ENROLL AS "RF"

LOOP 1
(LOW SENSITIVITY)
LOOP 2
(HIGH SENSITIVITY)

SERIAL #2
LOOP 2

LOOP 4 (TAMPER)
5870API
ENROLL AS "RF"

ST
AY

5820L
ENROLL AS "RF"

LOOP 1
SERIAL #2
LOOP 3

D

AD

5821
ENROLL AS "RF"

5819S (WHS & BRS)
ENROLL AS "RF"

SERIAL #2
LOOP 1

RE

LOOP 3

LOOP 1

LOOP 1
(INTERNAL
SHOCK
SENSOR

LOOP 1
(TERMINALS)
5819
ENROLL AS "RF"

SERIAL #1
LOOP 2

AR
ME

LOOPS
1-3

LOOP 3
(TERMINALS)

SERIAL #2
LOOP 1

SERIAL #1
LOOP 3

LOOP 2
(REED)

5811
ENROLL AS "RF"

LOOP 3
(TERMINALS)

LOOP 1
(TERMINALS)

5816
ENROLL AS "RF"

5809
ENROLL AS "RF"

5806/5806W3/5807
5808/5808LST/5808W3
ENROLL AS "RF"

LOOP 2
(REED)

ALTERNATE
POSITION
FOR LOOP 2
5814
ENROLL AS "RF"

LOOP 1

LOOP 1


•• •••
••• • •
• ••

LOOP 2
(REED)

LOOP 1
(TERMINALS)

LOOP 1

LOOP 1

LOOP 4

LOOP
1

5800SS1
E N RO L L A S " R F "

5800RL
SET HOUSE ID

LOOP 2

LOOP 2
LOOP 1
••

••

LOOP
1

ON

5800PIR-OD
ENROLL AS "RF"

5800PIR/5800PIR-COM
ENROLL AS "RF"

5877

5878
ENROLL AS "BR"

5898
ENROLL AS "RF"

5800-002-V2

5800Micra
ENROLL AS "RF"

5800CO
ENROLL AS "RF"

Notes: (1) The 5806W3 smoke detector must be used in SIA applications.
(2) Button type devices send only fault and low battery signals; no restore or check-in signals.
Supervised devices send periodic check-in signals, faults, restore and low battery signals.
Unsupervised devices send periodic check-in signals, faults, restore and low battery signals but the control does
not supervise the check-in signals.
(3) If an external sounder is required, the 5800WAVE should be used.
(4) The 5804E and 5834-4 encrypted (High-Security) devices must be activated while the system is in Go/No-Go
Test Mode. Refer to the transmitter’s Installation Instruction for complete details. The system will confirm the
enrollment of the encrypted device by beeping two times
(5) The 5800PIR-OD, 5800RL, 5800SS1, 5804E, 5804BD, 5804BDV, 5814, 5816TEMP, 5821, 5828/5828V, 5877,
and 5878 wireless transmitters have not been evaluated by UL/ETL

UL

The 5800RL, 5802MN, 5802MN2, 5804, 5804BD, 5804BDV, 5814, 5816TEMP, 5819, 5819S(WHS & BRS), and
5828/5828V wireless transmitters have not been evaluated by UL/ETL.

- 23 -

L5210 Programming Default Values
Program Function
Installer Code

Configuration 1

Configuration 2

Configuration 3

Configuration 4

4112

4112

4112

4112

RF Jam

Disabled

Disabled

Disabled

Disabled

Speaker Phone

Disabled

Disabled

Disabled

Disabled

Two Way Voice

Disabled

Disabled

Disabled

Disabled

RF House Code

0

0

0

0

Disabled

Disabled

Disabled

Disabled

System Type

Phone Notification
Remote Phone

Enabled

Enabled

Enabled

Enabled

Phone Detect Time

2 Minutes

2 Minutes

2 Minutes

2 Minutes

Events - Log All

Log All Set

Log All Set

Press to Log All

Press to Log All

Events - Log Alarm

Enabled

Enabled

Enabled

Enabled

Events - Log Bypass

Enabled

Enabled

Disabled

Disabled

Events - Log Open/Close

Enabled

Enabled

Disabled

Disabled

Events - Log Trouble

Enabled

Enabled

Enabled

Enabled

Non Security

Enabled

Enabled

Disabled

Disabled

Remote Access Serial

Disabled

Disabled

Disabled

Disabled

Multi Mode Serial
Date Time

Disabled

Disabled

Disabled

Disabled

January 1, 2014

January 1, 2014

January 1, 2014

January 1, 2014

Calendar
Enter Time

10:00AM

10:00AM

10:00AM

10:00AM

Time Zone

Eastern (EST)

Eastern (EST)

Eastern (EST)

Eastern (EST)

Day Light Savings time
Start Month

Yes

Yes

Yes

Yes

March

March

March

March

Start Week

Second

Second

Second

Second

End Month

November

November

November

November

First

First

First

First

End Week
Communicator
Communications Path

None

None

None

None

Disabled

Disabled

Disabled

Disabled

City ID

None

None

None

None

CS ID

None

None

None

None

Sub ID

None

None

None

None

24 Hours

24 Hours

24 Hours

24 Hours

APL

Supervision
Old Alarm Time

10 Minutes

10 Minutes

10 Minutes

10 Minutes

Remote Acc. Comm.

Disabled

Disabled

Disabled

Disabled

Multi Mode Comm.

Disabled

Disabled

Disabled

Disabled

GSM Fault Time

00

00

00

00

GSM Rollover

No

No

No

No

GSM 24 Hour Test

No

No

No

No

Use DHCP

Yes

Yes

Yes

Yes

NIC IP Address

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

Subnet Mask

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

Gateway IP Address

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

DNS Server IP Address
Zones
Reporter

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

See Zone Programming Default Configurations

Primary CS Info
Phone Type

Contact Id: 4 Digit

Contact Id: 4 Digit

Contact Id: 4 Digit

Communicator Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Account Number

FFFF

FFFF

FFFF

FFFF

- 24 -

Contact Id: 4 Digit

Program Function

Configuration 1

Configuration 2

Configuration 3

Configuration 4

Dynamic Priority

None

None

None

None

Dynamic Delay

None

None

None

None

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Enabled

Enabled

Enabled

Enabled

Report Troubles

Enabled

Enabled

Enabled

Enabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Enabled

Enabled

Enabled

Enabled

Report All

Secondary CS Info
Phone Type

None

None

None

None

Communicator Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Account Number

FFFF

FFFF

FFFF

FFFF

Dynamic Priority

None

None

None

None

Dynamic Delay
Report All
Report Alarms

None

None

None

None

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Enabled

Enabled

Enabled

Enabled

Report Troubles

Enabled

Enabled

Enabled

Enabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Enabled

Enabled

Enabled

Enabled

Follow Me Phone 1
Phone Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Disabled

Disabled

Disabled

Disabled

Report Troubles

Disabled

Disabled

Disabled

Disabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Disabled

Disabled

Disabled

Disabled

Report All

Follow Me Phone 2
Phone Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Report All

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Disabled

Disabled

Disabled

Disabled

Report Troubles

Disabled

Disabled

Disabled

Disabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Disabled

Disabled

Disabled

Disabled

Arm Away

Enabled

Enabled

Enabled

Enabled

Arm Stay

Enabled

Enabled

Enabled

Enabled

Disarm

Enabled

Enabled

Enabled

Enabled

Exit Error

Enabled

Enabled

Enabled

Enabled

Report Selection

Recent Closing

Enabled

Enabled

Enabled

Enabled

Event Log Full

Enabled

Enabled

Enabled

Enabled

Trouble

Enabled

Enabled

Enabled

Enabled

Trouble Restore

Enabled

Enabled

Enabled

Enabled

Alarm Restore

Enabled

Enabled

Enabled

Enabled

Alarm Cancel

Enabled

Enabled

Enabled

Enabled

Test

Enabled

Enabled

Enabled

Enabled

Test Restore

Enabled

Enabled

Enabled

Enabled

Bypass

Enabled

Enabled

Enabled

Enabled

Bypass Restore

Enabled

Enabled

Enabled

Enabled

AC Loss

Enabled

Enabled

Enabled

Enabled

AC Loss Restore

Enabled

Enabled

Enabled

Enabled

- 25 -

Program Function

Configuration 1

Configuration 2

Configuration 3

Configuration 4

Low Battery

Enabled

Enabled

Enabled

Enabled

Low Battery Restore

Enabled

Enabled

Enabled

Enabled

RF Low Battery

Enabled

Enabled

Enabled

Enabled

RF Low Battery Restore

Enabled

Enabled

Enabled

Enabled

Blank

Blank

Blank

Blank

Options
PBX
Call Wait Cancel

Blank

Blank

Blank

Blank

2 Reports

2 Reports

2 Reports

2 Reports

Alarm Report Delay

30 Sec.

30 Sec.

30 Sec.

30 Sec.

First Report Offset

6 Hrs

12 Hrs

12 Hrs

12 Hrs

Report Frequency

Never

30 Days

Never

Never

Yes

Yes

Yes

Yes

Abort Window

Downloader
Phone Answer
Ans. Machine Defeat

Yes

Yes

Yes

Yes

Modem Speed (Future Use)

Slow

Slow

Slow

Slow

2

2

2

2

Callback Number

Blank

Blank

Blank

Blank

Flexible Callback

No

No

No

No

1

1

1

1

Ring Counter

Number
Sounder
Burglary Alarm Sound

Yes

Yes

Yes

Yes

Burglary Bell Timeout

4 Minutes

4 Minutes

4 Minutes

4 Minutes

Fire Bell Timeout

4 Minutes

4 Minutes

4 Minutes

4 Minutes

Arm Confirm
System Settings

RF Keyfob

RF Keyfob

RF Keyfob

RF Keyfob

Entry Delay 1

30 Seconds

30 Seconds

30 Seconds

30 Seconds

Entry Delay 2

30 Seconds

30 Seconds

30 Seconds

30 Seconds

Exit Delay

60 Seconds

60 Seconds

60 Seconds

60 Seconds

Backlight Timeout

No

No

No

No

Quick Arm

Yes

Yes

Yes

Yes

Quick Exit

Yes

Yes

Yes

Yes

Restart Exit Time

Yes

Yes

Yes

Yes

Force Bypass

No

No

No

No

Exit Warning

Yes

Yes

Yes

Yes

Auto Stay Arming

Yes

Yes

Yes

Yes

Lack Of Usage Notify

Disabled

Disabled

Disabled

Disabled

Power-Up In Previous

Yes

Yes

Yes

Yes

Display Alarm Cancel

Yes

Yes

Yes

Yes

Display Exit Time

Yes

Yes

Yes

Yes

Cross Zone Delay

None

None

None

None

Cross Zone 1

Disabled

Disabled

Disabled

Disabled

Cross Zone 2
Z-Wave

Disabled

Disabled

Disabled

Disabled

Z-Wave
Temperature

Enabled

Enabled

Enabled

Enabled

Fahrenheit

Fahrenheit

Fahrenheit

Fahrenheit

- 26 -

L7000 Programming Default Values
Program Function
Installer Code

Configuration 1

Configuration 2

Configuration 3

Configuration 4

4112

4112

4112

4112

System Type
RF Jam

Disabled

Disabled

Disabled

Disabled

Speaker Phone

Disabled

Disabled

Disabled

Disabled

Two Way Voice

Disabled

Disabled

Disabled

Disabled

RF House Code

0

0

0

0

Phone Notification

Disabled

Disabled

Disabled

Disabled

Remote Phone

Enabled

Enabled

Enabled

Enabled

Phone Detect Time

2 Minutes

2 Minutes

2 Minutes

2 Minutes

Events - Log All

Log All Set

Log All Set

Press to Log All

Press to Log All

Events - Log Alarm

Enabled

Enabled

Enabled

Enabled

Events - Log Bypass

Enabled

Enabled

Disabled

Disabled
Disabled

Events - Log Open/Close

Enabled

Enabled

Disabled

Events - Log Trouble

Enabled

Enabled

Enabled

Enabled

Non Security

Enabled

Enabled

Disabled

Disabled

Remote Access Serial

Disabled

Disabled

Disabled

Disabled

Multi Mode Serial
Date Time

Disabled

Disabled

Disabled

Disabled

Calendar

January 1, 2014

January 1, 2014

January 1, 2014

January 1, 2014

Enter Time

10:00AM

10:00AM

10:00AM

10:00AM

Time Zone

Eastern (EST)

Eastern (EST)

Eastern (EST)

Eastern (EST)

Yes

Yes

Yes

Yes

March

March

March

March

Day Light Savings time
Start Month
Start Week

Second

Second

Second

Second

End Month

November

November

November

November

First

First

First

First

End Week
Communicator
Communications Path

None

None

None

None

Disabled

Disabled

Disabled

Disabled

City ID

None

None

None

None

CS ID

None

None

None

None

Sub ID

None

None

None

None

24 Hours

24 Hours

24 Hours

24 Hours
10 Minutes

APL

Supervision
Old Alarm Time

10 Minutes

10 Minutes

10 Minutes

Remote Acc. Comm.

Disabled

Disabled

Disabled

Disabled

Multi Mode Comm.

Disabled

Disabled

Disabled

Disabled

00

00

00

00

GSM Fault Time
GSM Rollover

No

No

No

No

GSM 24 Hour Test

No

No

No

No

Use DHCP

Yes

Yes

Yes

Yes

NIC IP Address

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

Subnet Mask

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

Gateway IP Address

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

DNS Server IP Address
Zones

255.255.255.255

255.255.255.255

255.255.255.255

255.255.255.255

See Zone Programming Default Configurations

Reporter
Primary CS Info
Phone Type

Contact Id: 4 Digit

Contact Id: 4 Digit

Contact Id: 4 Digit

Communicator Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

- 27 -

Contact Id: 4 Digit

Program Function
Account Number

Configuration 1

Configuration 2

Configuration 3

Configuration 4

FFFF

FFFF

FFFF

FFFF

Dynamic Priority

None

None

None

None

Dynamic Delay

None

None

None

None

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Enabled

Enabled

Enabled

Enabled

Report Troubles

Enabled

Enabled

Enabled

Enabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Enabled

Enabled

Enabled

Enabled

Phone Type

None

None

None

None

Communicator Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Account Number

FFFF

FFFF

FFFF

FFFF

Dynamic Priority

None

None

None

None

Report All

Secondary CS Info

Dynamic Delay
Report All
Report Alarms

None

None

None

None

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Enabled

Enabled

Enabled

Enabled

Report Troubles

Enabled

Enabled

Enabled

Enabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Enabled

Enabled

Enabled

Enabled

Follow Me Phone 1
Phone Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Disabled

Disabled

Disabled

Disabled

Report Troubles

Disabled

Disabled

Disabled

Disabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Disabled

Disabled

Disabled

Disabled

Report All

Follow Me Phone 2
Phone Type

None

None

None

None

Phone Number

Blank

Blank

Blank

Blank

Report All

Press to Report All

Press to Report All

Press to Report All

Press to Report All

Report Alarms

Disabled

Disabled

Disabled

Disabled

Report Troubles

Disabled

Disabled

Disabled

Disabled

Report Open/Close

Disabled

Disabled

Disabled

Disabled

Report Tests

Disabled

Disabled

Disabled

Disabled

Arm Away

Enabled

Enabled

Enabled

Enabled

Arm Stay

Enabled

Enabled

Enabled

Enabled

Disarm

Enabled

Enabled

Enabled

Enabled

Exit Error

Enabled

Enabled

Enabled

Enabled

Report Selection

Recent Closing

Enabled

Enabled

Enabled

Enabled

Event Log Full

Enabled

Enabled

Enabled

Enabled

Trouble

Enabled

Enabled

Enabled

Enabled

Trouble Restore

Enabled

Enabled

Enabled

Enabled

Alarm Restore

Enabled

Enabled

Enabled

Enabled

Alarm Cancel

Enabled

Enabled

Enabled

Enabled

Test

Enabled

Enabled

Enabled

Enabled

Test Restore

Enabled

Enabled

Enabled

Enabled

Bypass

Enabled

Enabled

Enabled

Enabled

Bypass Restore

Enabled

Enabled

Enabled

Enabled

AC Loss

Enabled

Enabled

Enabled

Enabled

- 28 -

Program Function

Configuration 1

Configuration 2

Configuration 3

Configuration 4

AC Loss Restore

Enabled

Enabled

Enabled

Enabled

Low Battery

Enabled

Enabled

Enabled

Enabled

Low Battery Restore

Enabled

Enabled

Enabled

Enabled

RF Low Battery

Enabled

Enabled

Enabled

Enabled

RF Low Battery Restore

Enabled

Enabled

Enabled

Enabled

Blank

Blank

Blank

Blank

Options
PBX
Call Wait Cancel

Blank

Blank

Blank

Blank

2 Reports

2 Reports

2 Reports

2 Reports

Alarm Report Delay

30 Sec.

30 Sec.

30 Sec.

30 Sec.

First Report Offset

6 Hrs

12 Hrs

12 Hrs

12 Hrs

Report Frequency

Never

30 Days

Never

Never

Yes

Yes

Yes

Yes

Abort Window

Downloader
Phone Answer
Ans. Machine Defeat

Yes

Yes

Yes

Yes

Modem Speed (Future Use)

Slow

Slow

Slow

Slow

2

2

2

2

Callback Number

Blank

Blank

Blank

Blank

Flexible Callback

No

No

No

No

1

1

1

1

Ring Counter

Number
Sounder
Burglary Alarm Sound

Yes

Yes

Yes

Yes

Burglary Bell Timeout

4 Minutes

4 Minutes

4 Minutes

4 Minutes

Fire Bell Timeout

4 Minutes

4 Minutes

4 Minutes

4 Minutes

Arm Confirm

RF Keyfob

RF Keyfob

RF Keyfob

RF Keyfob

Entry Delay 1

30 Seconds

30 Seconds

30 Seconds

30 Seconds

Entry Delay 2

30 Seconds

30 Seconds

30 Seconds

30 Seconds

Exit Delay

60 Seconds

System Settings

60 Seconds

60 Seconds

60 Seconds

Backlight Timeout

No

No

No

No

Quick Arm

Yes

Yes

Yes

Yes

Quick Exit

Yes

Yes

Yes

Yes

Restart Exit Time

Yes

Yes

Yes

Yes

Force Bypass

No

No

No

No

Exit Warning

Yes

Yes

Yes

Yes

Auto Stay Arming

Yes

Yes

Yes

Yes

Lack Of Usage Notify

Disabled

Disabled

Disabled

Disabled

Power-Up In Previous

Yes

Yes

Yes

Yes

Display Alarm Cancel

Yes

Yes

Yes

Yes

Display Exit Time

Yes

Yes

Yes

Yes

Cross Zone Delay

None

None

None

None

Cross Zone 1

Disabled

Disabled

Disabled

Disabled

Cross Zone 2
Z-Wave

Disabled

Disabled

Disabled

Disabled

Z-Wave

Enabled

Enabled

Enabled

Enabled

Fahrenheit

Fahrenheit

Fahrenheit

Fahrenheit

Temperature

- 29 -

- Notes -

- 30 -

- 31 -

EDGE
CONNECTOR
(L5100ZWAVE)

PHONE
(L5201/L5201CN ONLY)

REPLACE EVERY FOUR YEARS

P/N 300-03864-1/LYNXRCHKIT-SC
P/N 300-03866/LYNXRCHKIT-SHA

THE LYNX TOUCH CONTROLS ARE COMPATIBLE WITH THE
FOLLOWING INTEGRAL RECHARGEABLE BATTERY PACKS:

SUPER HIGH CAPACITY
BATTERY CONNECTOR

EGND

EARTH GROUND

STANDARD CAPACITY
BATTERY CONNECTOR

WEEKLY TESTING IS REQUIRED TO ENSURE
PROPER OPERATION OF THIS SYSTEM

TAMPER
SWITCH

COMMUNICATIONS MODULE
RECEPTACLE

ZONES

2K
OHM
EOLR

HARD
WIRED
ZONE

GND

NOTE: THE HARDWIRE ZONE CANNOT BE USED AS A FIRE ZONE.

WARNING

Be sure to observe
polarity when
connecting the
power supply to
the terminal strip.

IMPORTANT

02 - 48
ZT16

CIRCUIT
(ZONE)

30 seconds

CONTROL UNIT
DELAY-SEC

5806W3

5201-100-SOC-V0

10 seconds

SMOKE DETECTOR
MODEL
DELAY-SEC

THIS UNIT MAY BE PROGRAMMED TO INCLUDE AN ALARM
VERIFICATION FEATURE THAT WILL RESULT IN A DELAY OF THE
SYSTEM ALARM SIGNAL FROM THE INDICATED FIRE CIRCUITS.
THE TOTAL DELAY (CONTROL UNIT PLUS SMOKE DETECTORS)
SHALL NOT EXCEED 60 SECONDS. NO OTHER INITIATING
DEVICES SHALL BE CONNECTED TO THESE CIRCUITS UNLESS
APPROVED BY THE LOCAL AUTHORITY HAVING JURISDICTION.

EDGE
CONNECTOR
(L5100-WiFi)

POWER SUPPLY
CONNECTOR

300-04705V1 or 300-04065V1
(300-04063V1 or 300-04064V1
CANADA)
POWER SUPPLY 9V, 2.7A

THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES. OPERATION IS
SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS DEVICE MAY
NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST
ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE
THAT MAY CAUSE UNDESIRED OPERATION.

POWER

GND

LYNX TOUCH SERIES SUMMARY OF CONNECTIONS

RING

TIP

RING

TIP

TIP

COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION
No. AC3AL05BL5000
RINGER EQUIVALENCE: 0.5B

UL INSTALLATIONS
THE MINIMUM WIRE
SIZE USED FOR
TELEPHONE
INSTALLATIONS
MUST BE #26 GAGE

RING

PREMISES
TELEPHONE

H/S T

INCOMING
PHONE LINE

HWZ1

WARNING
TO PREVENT RISK OF
SHOCK, DISCONNECT
TELEPHONE LINE
AT TELECOM JACK
BEFORE SERVICING
THIS UNIT

H/S R

LYNX TOUCH SERIES ALSO COMPLIES WITH THE FOLLOWING:
CANADIAN STANDARDS ASSOCIATION (CSA) C22.1,
CANADIAN ELECTRICAL CODE, PART 1, SAFETY STANDARD
FOR ELECTRICAL INSTALLATIONS AND CAN/ULC-S540
INSTALLATION OF RESIDENTIAL FIRE WARNING SYSTEMS.

TRIGGER OUTPUT (NEG)
(3ma)
TRIG

THIS EQUIPMENT SHOULD BE INSTALLED IN ACCORDANCE WITH THE NATIONAL FIRE
PROTECTION ASSOCIATION STANDARDS ANSI/NFPA 70 NATONAL ELECTRIC CODE AND
NFPA 72 NATIONAL FIRE ALARM CODE, CHAPTER 2 (NATIONAL FIRE PROTECTION
ASSOC., BATTERY MARCH PARK, QUINCY, MA 02169). PRINTED INFORMATION
ESCRIBING PROPER INSTALLATION, EVACUATION PLANNING AND REPAIR SERVICE IS TO
BE PROVIDED WITH THIS EQUIPMENT.

+9VDC

2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2014 Honeywell International Inc.
www.honeywell.com/security

Ê800-199766Š
800-19976 12/14 Rev. B


Uploaded