Leviton VP00R-10Z, VP00R-1LZ, VP0SR-10Z and VP0SR-1LZ Product Manual and Setup Guide
Related Products
Related Categories
Document Transcript
. 3-Way or More Applications (Multi-location) Remote Devices Cat. No. VP00R-10, Coordinating Dimmer Remote Cat. No. VP00R-1L, Matching Dimmer Remote Cat. No. VP0SR-10, Coordinating Switch Remote Cat. No. VP0SR-1L, Matching Switch Remote 120VAC, 60Hz PK-93461-10-00-2A INSTALLATION INSTRUCTIONSWARNINGS AND CAUTIONS: WARNINGS AND CAUTIONS:• To be installed and/or used in accordance with appropriate electrical codes and regulations. • Use only one (1) Vizia +™ dimmer in a multi-location circuit with up to 9 coordinating remotes without LEDs or up to 4 matching remotes with LEDs. The remote(s)• If you are unsure about any part of these instructions, consult a qualified electrician. will turn the light on at the brightness level selected at the dimmer.• To avoid overheating and possible damage to this device and other equipment, do not install to control a receptacle, fluorescent lighting, a motor- or a • Recommended minimum wall box depth is 2-1/2". transformer-operated appliance. • Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).• For Hi-lume® or Eco-10® (EcoSeries) electronic ballast applications, use instruction sheet that comes with the dimmer for multi-location applications. • Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.• Vizia +™ remotes are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia +™ or Vizia rf +™ devices for multi-location • Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL. switching. Tools needed to install your Remote: Step 2 cont’d Step 4b 3-Way Wiring with Coordinating Remote (no LEDs) NOTE: The control must be installed in a wall box that has a Load Step 4d cont’d Application: connection. The matching remote must be installed in a wall box with Slotted/Phillips Screwdriver Electrical Tape NOTE: Incandescent and Magnetic Low Voltage a Line Hot connection and a Neutral connection. A Neutral wire to the WIRING COORDINATING REMOTE: Pliers Pencil installations only. NOTE: Screw terminal dimmer matching remote needs to be added as shown. Connect wires per WIRING DIAGRAM as follows: Cutters Ruler depicted. If you are unsure about any part of these instructions, consult a NOTE: "BK" and "RD" terminals on coordinating remote are qualified electrician. unused. Tighten both screws. Changing the color of your Device: Coordinating Remote Dimmer Your device may include color options. To change color of the face NOTE: Maximum wire length from control to all installed remotes NOTE: Maximum wire length from control to last remote is proceed as follows: cannot exceed 300 ft (90 m). 300 ft (90 m). Side Wire Connection Back Wire Wiring Matching Remote (wall box with Line Hot Side wire terminals accept • Green or bare copper wire in wall box to Green terminal screw. (either hole may be used) Terminal Bk 1 Bk 1 connection): #14 AWG solid copper wire Screw marked • Load wall box wire identified (tagged) when removing old switch Back wire openings use 2 2 Connect wires per WIRING DIAGRAM as follows: only. Black (Bk) to First Traveler (note color as above). #14-12 AWG solid copper wire only. Terminal 3 3 • Green or bare copper wire in wall box to Green terminal screw. • Second Traveler wall box wire (note color as above) to terminal Screw marked 4 4 Yellow/Red YL/RD RD YL/RD RD • Line Hot (common) wall box wire identified (tagged) when removing screw marked "YL/RD". This traveler from the remote must go to (YL/RD) 5 5 old switch and First Traveler to terminal screw marked "BK" or Black the terminal screw marked "YL/RD" or Yellow/Red control lead. 5/8" Terminal dimmer lead. (1.6 cm) Screw marked • Remove White insulating label from terminal screw marked Strip Gage (measure bare wire here or Red (RD) • Second Traveler wall box wire from control to remote terminal screw "WH". use gage on back of the dimmer) marked "YL/RD" (note wire color). This traveler from the remote • Line Neutral wall box wire to terminal screw marked "WH". Coordinating Remote (no LEDs) Dimmer must go to terminal screw marked "YL/RD" or Yellow/Red control • Proceed to Step 6. Line up tabs and lead. Push in side at tab press in sides one at not used Wh Bk hot (Black) • Line Neutral wall box to remote terminal screw marked "WH". to release a time to attach • Make sure that the ends of the wires from the wall box are straight Black Bk Step 5a 4-Way Wiring with Matching Remote (w/LEDs) (cut if necessary). Green Ground Green Wiring Dimmer (wall box with Load connection): Application: Ground • Remove insulation from each wire in the wall box as shown. NOTE: Incandescent and Magnetic Low Voltage INSTALLING YOUR REMOTE RD YL/RD RD YL/RD Line Connect wires per WIRING DIAGRAM as follows: Load installations only. 120vAC, 60hz • Green or bare copper wire in wall box to Green terminal screw or 3-Way Wiring with Matching Remote (w/LEDs) NOTE: Screw terminal dimmer depicted. NOTE: Use check boxes when Steps are completed. Step 4a Green control lead. Application: White Matching Remote Matching Remote Dimmer NOTE: Incandescent and Magnetic Low Voltage • Load wall box wire identified (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall box from Step 2) Step 1 WARNING: To avoid fire, shock, or death; installations only. Neutral (White) (tagged) when removing old switch Terminal Terminal Additional turn off power at circuit breaker or fuse and test NOTE: Screw terminal dimmer depicted. to terminal screw marked "RD" or Screw marked White (Wh) Neutral Wire Screw marked White (Wh) Additional Neutral Wire that power is off before wiring! WIRING DIMMER: Red control lead. 4 2 Matching Remote Dimmer Connect wires per WIRING DIAGRAM as follows: • First Traveler Line Hot to terminal Terminal Bk Terminal 1 3 Bk Bk Terminal Screw marked 1 Screw marked Screw marked Additional Neutral Wire NOTE: When using the coordinating remote without LEDs, the dimmer screw marked "BK" or Black Black (Bk) 4 Black (Bk) 5 2 White (Wh) can be installed on either the Line or Load side of the 3-way circuit. control lead. Terminal 3 4 3 4 Screw marked Terminal Bk 2 Bk NOTE: Maximum wire length from dimmer to all installed remotes • Remove Red insulating label from Yellow/Red 5 Screw marked YL/RD RD 2 RD 1 RD Terminal (YL/RD) Yellow/Red YL/RD YL/RD Screw marked 1 2 cannot exceed 300 ft (90 m). terminal screw marked "YL/RD" or (YL/RD) 6 5 Black (Bk) 4 • Green or bare copper wire in wall box to Green terminal screw or Yellow/Red control lead. 3 Terminal 3 Screw marked 1 Green dimmer lead. • Second Traveler wall box wire Yellow/Red (YL/RD) YL/RD RD 5 YL/RD RD 5 • Line Hot (common) wall box wire identified (tagged) when removing (note color as above) to terminal old switch to dimmer terminal screw marked "BK" or Black dimmer screw marked "YL/RD" or Yellow/Red control lead. This traveler lead. from the control must go to the terminal screw on the remote Matching Remote Matching Remote marked "YL/RD". (w/LEDs) (w/LEDs) Dimmer Identifying your wiring application (most • First Traveler wall box wire to terminal screw marked "RD" or Red Step 2 • Line neutral wall box wire to terminal screw marked "WH" or common): dimmer lead (note wire color). This traveler from the dimmer must go to the terminal screw on the remote marked "RD". White control lead. hot (Black) Wh Bk Wh Bk Bk NOTE: If the wiring in the wall box does not resemble Matching Remote (w/LEDs) Dimmer • Remove Red insulating label from terminal screw marked • Proceed to Step 6. Green Ground Green Green Black any of these configurations, consult a qualified Ground Ground electrician. hot (Black) Wh Bk Bk "YL/RD" or Yellow/Red dimmer lead. YL/RD Step 4d 3-Way Wiring with Coordinating Remote (no Line YL/RD YL/RD RD Load Green Ground Green Ground • Second Traveler wall box wire to terminal screw marked "YL/RD" or LEDs) for Controls with Neutral Connection 120vAC, 60hz Black Yellow/Red dimmer lead (note wire color). This traveler from the Application: White Line YL/RD RD YL/RD dimmer must go to the terminal screw on the remote marked "YL/RD". 120vAC, 60hz Load NOTE: Electronic Low Voltage, Mark 10™, Quiet WIRING COORDINATING REMOTE: Fan Speed and Electronic Switch installations only. Neutral (White) White Connect wires per WIRING DIAGRAM as follows: NOTE: Dimmer is depicted. 1 2 1 3 NOTE: Maximum wire length from dimmer to last remote is Neutral (White) 300 ft (90 m). Coordinating Remote Control 2 Terminal NOTE: The dimmer must be installed in a wall box that has a Load • Green or bare copper wire in wall box to Green terminal screw. Screw marked 3 4 NOTE: The dimmer must be installed in a wall box that has a Load White (WH) connection. The matching remote must be installed in a wall box • Load wall box wire identified (tagged) when removing old switch to Black with a Line Hot connection and a Neutral connection. A Neutral wire 4 5 connection. The matching remote must be installed in a wall box with terminal screw marked "BK". BK 1 a Line Hot connection and a Neutral connection. A Neutral wire to the White to the matching remote needs to be added as shown. 5 6 2 matching remote needs to be added as shown. • First Traveler wall box wire (note color as above) to terminal screw 1 2 If you are unsure about any part of these instructions, consult a marked "RD". This traveler from the remote must go to the terminal 3 Green qualified electrician. If you are unsure about any part of these instructions, consult a screw on the dimmer marked "RD" or Red dimmer lead. 4 qualified electrician. YL/RD RD 5 3 NOTE: Maximum wire length from dimmer to all installed remotes • Second Traveler wall box wire (note color as above) to terminal Terminal Red cannot exceed 300 ft (90 m). NOTE: Maximum wire length from dimmer to all installed remotes screw marked "YL/RD". This traveler from the remote must go to Screw marked 4 cannot exceed 300 ft. Yellow/Red Yellow/Red Wiring Matching Remote (4-Way wall box with Line 3-Way 4-Way the terminal screw on the dimmer marked "YL/RD" or Yellow/Red (YL/RD) Wiring Matching Remote (wall box with Line Hot 5 Hot connection): 1. Line or Load (See important 1. First Traveler – note color dimmer lead. connection): Connect wires per WIRING DIAGRAM as follows: instruction below) 2. Second Traveler – tagged • Remote terminal screw marked "WH" should have White insulation Connect wires per WIRING DIAGRAM as follows: • Green or bare copper wire in wall box to Green terminal screw. 2. Neutral label affixed. Coordinating Remote (no LEDs) Control 3. Neutral • Green or bare copper wire in wall box to Green terminal screw. • First Traveler and Third Traveler wall box wire from dimmer in 3. Ground 4. Ground NOTE: If insulating label is not affixed to terminal screw marked • Line Hot (common) wall box wire identified (tagged) when removing WH BK White Black Hot (Black) the 3-way box to remote terminal screw marked "BK" in the 4. First Traveler – note color "WH", use electrical tape to cover. not used 5. Third Traveler – note color old switch and First Traveler to remote terminal screw marked “BK” 4-way box, and to the terminal screw marked "BK" of the 5. Second Traveler – note color • Proceed to Step 6. Black Green Ground Green Ground remaining remote in the 3-way box. 6. Fourth Traveler – tagged or the Black dimmer lead. NOTE: For matching remote 3-Way Wiring with Matching Remote RD Red YL/RD • Second Traveler (tagged) and Fourth Traveler (tagged) wall box NOTE: For matching remote • Second Traveler wall box wire from dimmer to remote terminal Step 4c not used YL/RD Line w/LEDs installation, the First screw marked “YL/RD” (note wire color). This traveler from the (w/LEDs) for Controls with Neutral Connection Load 120VAC, 60Hz wire from dimmer in the 3-way box to remote terminal screw w/LEDs installation, the First marked "YL/RD" in the 4-way box, and to the terminal screw Traveler becomes Line Hot. remote must go to the terminal screw on the dimmer marked Application: Traveler becomes Line Hot. White marked "YL/RD" of the remaining remote in the 3-way box (note “YL/RD” or the Yellow/Red dimmer lead. NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan IMPORTANT: Speed and Electronic Switch installations only. wire colors). This traveler from the remotes must go to the • Line Neutral wall box to remote terminal screw marked “WH”. Neutral (White) terminal screw on the dimmer marked "YL/RD" or the Yellow/Red For 3-Way applications, note that one of the screw terminals from NOTE: Dimmer is depicted. Wiring Dimmer (wall box with Load connection): dimmer lead. the old switch being removed will usually be a different color (Black) Matching Remote Control Connect wires per WIRING DIAGRAM as follows: WIRING CONTROL: • Line Neutral wall box wire to remote terminal screw marked or labeled Common. Tag that wire with electrical tape and identify Terminal Green as the common (Line or Load) in both the dimmer wall box and • Green or bare copper wire in wall box to Green terminal screw or Screw marked Additional Neutral Wire Connect wires per WIRING DIAGRAM as follows: "WH". White (WH) remote wall box. Green dimmer lead. Black 4 NOTE: The control must be installed in a wall box that has a Line Hot 2 Connection. Wiring MATCHING REMOTE (3-Way wall box with Line • Load wall box wire identified (tagged) when removing old switch to BK Hot connection): For 4-Way applications, note that the old switch being removed Terminal 2 dimmer terminal screw marked “RD” or the Red dimmer lead. Screw marked 1 White NOTE: Maximum wire length from dimmer to all installed remotes Connect wires per WIRING DIAGRAM as follows: will have 4 screws plus a ground screw. Tag the two same color Black (BK) 4 insulated wires with electrical tape. • First Traveler Line Hot to dimmer terminal screw marked “BK” or the cannot exceed 300 ft (90 m). Terminal 3 Red 3 • Green or bare copper wire in wall box to Green terminal screw. Black dimmer lead. Screw marked 1 • Green or bare copper wire in wall box to Green terminal screw or Yellow/Red RD 5 • Line Hot (common) wall box wire identified (tagged) when • Remove Red insulating label from terminal screw marked “YL/RD” (YL/RD) YL/RD Green control lead. Step 3 Preparing and connecting wires: 5 removing old switch and First Traveler dimmer terminal screw or Yellow/Red dimmer lead. • Line Hot (common) wall box wire identified (tagged) when removing marked "BK" or the Black dimmer lead. This remote can be wired using side wire terminal Yellow/Red • Second Traveler wall box wire (note color as above) to dimmer old switch to terminal screw marked "BK" or Black control lead. screws or through backwire openings. Choose • Second Traveler wall box wire from dimmer to remote terminal appropriate wire stripping specifications accordingly. terminal screw marked “YL/RD” or the Yellow/Red dimmer lead. • First Traveler wall box wire to terminal screw marked "RD" or Red screw marked "YL/RD" (note wire color as above). This traveler This traveler from the dimmer must go to the terminal screw on the Matching Remote (w/LEDs) Control control lead (note wire color). from the remote must go to the terminal screw on the dimmer remote marked “YL/RD”. • Remove Red insulating label from terminal screw marked "YL/RD" marked "YL/RD" or the Yellow/Red dimmer lead. • Proceed to Step 6. WH BK White Black or Yellow/Red control lead. • Line Neutral wall box wire to remote terminal screw marked Hot (Black) Green Ground Green Ground • Second Traveler wall box wire to terminal screw marked "YL/RD" "WH". Black or Yellow/Red control lead (note wire color). This traveler from YL/RD Red Yellow/Red the control must go to the terminal screw on the remote marked Line 120VAC, 60Hz Load "YL/RD". Cut • Line Neutral wall box wire to terminal screw marked "WH" or White (if necessary) White control lead. Neutral (White)
2. Step 5a cont’d 4-Way Wiring with Matching Remote (w/LEDs) Step 5c 4-Way Wiring with Matching Remote (w/LEDs) for Controls Step 5d cont’d OPERATION Application: with Neutral Connection Application: NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and Electronic WIRING COORDINATING REMOTE (4-Way box): CLEANING: Clean with a damp cloth. DO NOT use chemical cleaners. Wiring Dimmer (3-Way wall box with Load connection): Switch installations only. Connect wires per WIRING DIAGRAM as follows: Connect wires per WIRING DIAGRAM as follows: NOTE: Dimmer is depicted. VP00R Dimmer Remote Operation (Device may be unlighted): NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both • Green or bare copper wire in wall box to Green terminal screw or Green dimmer screws. NOTE: The lights will turn ON at brightness set on dimmer’s DIM/BRIGHT bar. The Matching Remote Matching Remote Control lead. (3-Way Wall box from Step 2) (4-Way Wall box from Step 2) (3-Way Wall Box from Step 2) NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). lighting can be switched from either the dimmer or the remote location. Terminal Terminal • Load wall box wire identified (tagged) when removing old switch to dimmer terminal Screw marked Additional Screw marked Additional Green • Green or bare copper wire in wall box to Green terminal screw. White (WH) Neutral Wire White (WH) Neutral Wire LED Push Pad (Default settings) screw marked "RD" or the Red dimmer lead. 2 Black 4 • Connect First Traveler wall box wire to Third Traveler wall box wire (note wire colors) Brightness Turn ON from OFF position: • First Traveler Line Hot to dimmer terminal screw marked "BK" or the Black dimmer Terminal BK Terminal BK 3 to terminal screw marked "RD" of remote in 4-way box, and to terminal screw marked Display DIM/BRIGHT lead. Screw marked 1 Screw marked 1 2 Tap – Lights turn ON to preset level. Black (BK) 4 Black (BK) 5 White "RD" of the remaining remote in 3-way box. Bar Press and Hold – Lights turn ON to full bright. • Remove Red insulating label from terminal screw marked "YL/RD" or the Yellow/ Terminal 3 4 • Connect Second Traveler and Fourth Traveler wall box wire (note wire colors) to Screw marked Terminal Red 3 Turn OFF from ON position: Red dimmer lead. Yellow/Red YL/RD 5 RD Screw marked Yellow/Red 2 RD 1 terminal screw marked "YL/RD" of remote in 4-way box, and to terminal screw marked Tap – Lights turn OFF. YL/RD (YL/RD) (YL/RD) 6 • Second Traveler wall box wire (note color as above) to dimmer terminal screw 5 "YL/RD" of the remaining remote in 3-way box. marked "YL/RD" or the Yellow/Red dimmer lead. This traveler from the dimmer DIM/BRIGHT Bar This traveler from the remotes must go to the terminal screw marked "YL/RD" or Yellow/Red must go to the terminal screw on the remote marked "YL/RD". BRIGHTEN: Yellow/Red control lead. Press right half of DIM/BRIGHT Bar – Lights brighten to • Proceed to Step 6. • Remove White insulating label from terminal screw marked "WH". Matching Remote Matching Remote desired level. (w/LEDs) (w/LEDs) Control • Line Neutral wall box wire to terminal screw marked "WH". DIM: Step 5b 4-Way Wiring with Coordinating Remote (no LEDs) Press left half of DIM/BRIGHT Bar – Lights dim to Application: WH BK WH BK White Black WIRING CONTROL (3-Way box): desired level. Hot (Black) Connect wires per WIRING DIAGRAM as follows: NOTE: Incandescent and Magnetic Low Voltage installations only. Green Green Green If you continue to hold, the lights will DIM to minimum NOTE: Screw terminal dimmer depicted. Ground Ground Ground NOTE: The control must be installed in a wall box that has a Line Hot connection. level and then turn OFF. Black YL/RD YL/RD Red Yellow/Red NOTE: Maximum wire length from control to all installed remotes cannot exceed 300 ft In the event of power outage or interruption the lights will Line Coordinating Remote Coordinating Remote Dimmer 120VAC, 60Hz Load (90 m). reset to the last level when power is restored. (3-Way Wall box from Step 2) (4-Way Box from Step 2) (3-Way Wall Box from Step 2) Push Pad • Green or bare copper wire in wall box to Green terminal screw or Green control lead. Locator Terminal Screw marked White • Line Hot (common) wall box wire identified (tagged) when removing old switch to Light Red (RD) terminal screw marked "BK" or Black control lead. Bk Neutral (White) • First Traveler wall box wire to terminal screw marked "RD" or Red control lead (note Bk Bk TerminalScrew marked 1 2 3 1 VP0SR Switch Remote Operation (Device may be unlighted): Black (Bk) 2 wire color as above). 4 The lighting can be switched from either the dimmer or the remote location. Terminal 3 1 5 3 NOTE: The control must be installed in a wall box that has a Load connection. The • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red 4Screw marked Yellow/Red YL/RD RD YL/RD RD 2 YL/RD RD 4 matching remote must be installed in a wall box with a Line Hot connection and a Neutral control lead. 5 (YL/RD) 6 5 connection. A Neutral wire to the matching remote needs to be added as shown. Push Pad (Default settings) Terminal Screw marked • Second Traveler wall box wire to terminal screw marked "YL/RD" or Yellow/Red Red (RD) Terminal Screw marked If you are unsure about any part of these instructions, consult a qualified electrician. control lead (note wire color as above). This traveler from the control must go to the Turn ON from OFF position: Yellow/Red (YL/RD) NOTE: Maximum wire length from control to all installed remotes cannot exceed terminal screw on the remote marked "YL/RD". Tap – Lights turn ON to preset level. 300 ft (90 m). • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. Turn OFF from ON position: Wiring Matching Remote (4-Way wall box with Line Hot connection): Tap – Lights turn OFF. Coordinating Remote Coordinating Remote WIRING COORDINATING REMOTE (3-Way box): (no LEDs) (no LEDs) Dimmer Connect wires per WIRING DIAGRAM as follows: Connect wires per WIRING DIAGRAM as follows: In the event of power outage or • Green or bare copper wire in wall box to Green terminal screw. interruption the lights will reset to the last NOTE: "BK" and "RD" terminals on coordinating remote are unused. Tighten both level when power is restored. not used Wh Bk not used Wh not used Bk hot (Black) • First Traveler and Third Traveler wall box wire to remote terminal screw marked "BK" screws. Bk Black Green Green Green in 4-way box, and to terminal screw marked "BK" of the remaining remote in 3-way NOTE: Maximum wire length from control to last remote is 300 ft (90 m). Ground Ground Ground box. Push Pad • Green or bare copper wire in wall box to Green terminal screw. RD YL/RD RD YL/RD RD YL/RD • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire from control inLoad Line • Load wall box wire identified (tagged) when removing old switch to First Traveler (note 120vAC, 60hz 3-way box to remote terminal screw marked "YL/RD" in 4-way box and to terminal Locator color as above). screw marked "YL/RD" of the remaining remote in 3-way box (note wire colors). This Light White traveler from the remotes must go to the terminal screw marked "YL/RD" or • Second Traveler wall box wire (note color as above) to terminal screw marked Yellow/Red control lead. "YL/RD". This traveler from the remote must go to the terminal screw marked "YL/RD" or Yellow/Red control lead. VP00R-1L ADVANCED PROGRAMMING FEATURES Neutral (White) • Line Neutral wall box wire to remote terminal screw marked "WH". • Remove White insulating label from terminal screw marked "WH". FOR USE WITH VIZIA RF +™ ONLY WIRING COORDINATING REMOTE (4-Way box): Wiring MATCHING REMOTE (3-Way wall box with Line Hot connection): • Line Neutral wall box wire to terminal screw marked "WH". Connect wires per WIRING DIAGRAM as follows: Connect wires per WIRING DIAGRAM as follows: Definition of A Modes • Proceed to Step 6. NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). • Green or bare copper wire in wall box to Green terminal screw. A) LED Options: Sets single LED (default) or LED Bar to display the load status. • Green or bare copper wire in wall box to Green terminal screw. • Line Hot (common) wall box wire identified (tagged) when removing old switch and Step 6 Testing your Remote prior to completely Program Mode A First Traveler wall box wire to control terminal screw marked "BK" or Black dimmer mounting in wall box: To enter Program Mode A: • First Traveler and Third Traveler wall box wire (note wire colors) to terminal lead. Press and hold the Push Pad and then the right half of the DIM/BRIGHT Bar (^) for 5 screw marked "RD". These travelers from the remote in the 4-way box must go to the terminal screw on the dimmer marked "RD" or Red dimmer lead, and to the • Second Traveler wall box wire from control to remote terminal screw marked "YL/RD" seconds until all LEDs blink. terminal screw marked "RD" of the remaining remote in the 3-way box. (note wire color as above). This traveler from the remote must go to the terminal Upon releasing the Push Pad Locator LED will blink once per second to indicate screw marked "YL/RD" or Yellow/Red dimmer lead. Program Mode A, LED Options. To change the LED Options settings, release • Second Traveler (tagged) and Fourth Traveler (tagged) wall box wire (note wire • Position all wires to provide room in colors) to terminal screw marked "YL/RD". These travelers from the remote in • Line Neutral wall box wire to remote terminal screw marked "WH". outlet wall box for device. the Push Pad. This setting will automatically be saved and the device will exit the 4-way box must go to the terminal screw on the dimmer marked "YL/RD" or Programming Mode. Wiring CONTROL (3-Way wall box with Load connection): • Ensure that the word "TOP" is facing up the Yellow/Red dimmer lead, and to the terminal screw marked "YL/RD" of the on the device strap. LED Brightness/Fan Speed Display Connect wires per WIRING DIAGRAM as follows: LED Options remaining remote in the 3-way box. • Green or bare copper wire in wall box to Green terminal screw or Green dimmer lead. • Partially screw in mounting screws in • Remote terminal screw marked "WH" should have White insulation label affixed. Default Single LED • Load wall box wire identified (tagged) when removing old switch to terminal screw wall box mounting hole. NOTE: If insulating label is not affixed to terminal screw marked "WH", use electrical tape to cover. Remote terminal screw marked "BK" is not used. Use marked "RD" or Red control lead. First toggle LED Bar electrical tape to cover. • First Traveler Line Hot to terminal screw marked "BK" or Black control lead. WIRING DIMMER (3-Way box): • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red TROUBLESHOOTING control lead. Connect wires per WIRING DIAGRAM as follows: • Lights Flickering • Second Traveler wall box wire (note color as above) to terminal screw marked NOTE: When using the coordinating remote without LEDs, the dimmer can be - Lamp has a bad connection. "YL/RD" or Yellow/Red control lead. This traveler from the control must go to the installed on either the Line or Load side of the 3-way circuit. - Wires not secured firmly under terminal screws of dimmer and/or remote. terminal screw on the remote marked "YL/RD". NOTE: Maximum wire length from dimmer to all installed remotes cannot exceed • Light does not turn ON and Locator LED does not turn ON • Line Neutral wall box wire to terminal screw marked "WH" or White control lead. 300 ft (90 m). • Proceed to Step 6. - Circuit breaker or fuse has tripped. • Green or bare copper wire in wall box to Green terminal screw or Green dimmer - Lamp is burned out. lead. Step 5d 4-Way Wiring with Coordinating Remote (no LEDs) for Controls - Lamp Neutral connection is not wired. • Line Hot (common) wall box wire identified (tagged) when removing old switch to with Neutral Connection Application: dimmer terminal screw marked "BK" or Black dimmer lead. • Intermittent dimmer operation NOTE: Electronic Low Voltage, Mark 10™, Quiet Fan Speed and - Minimum load is under 40W. • First Traveler wall box wire to dimmer terminal screw marked "RD" or Red dimmer Electronic Switch installations only. NOTE: Dimmer is depicted. lead (note wire color as above). This traveler from the dimmer must go to the • Remote does not operate lights terminal screw on the remote marked "RD". - Ensure that total wire length does not exceed 300 ft (90 m). Coordinating Remote Coordinating Remote Control • Remove Red insulating label from terminal screw marked "YL/RD" or Yellow/Red (3-Way Wall box from Step 2) (4-Way Box from Step 2) (3-Way Wall Box from Step 2) - Ensure that only Coordinating Remotes are used with Vizia rf +™ devices dimmer lead. Terminal Screw marked Terminal Screw marked • Second Traveler wall box wire to dimmer terminal screw marked "YL/RD" or Yellow/ White (WH) White (WH) For additional information, contact Leviton’s Techline at Black Red dimmer lead (note wire color as above). This traveler from the dimmer must Terminal BK Terminal BK 1 1-800-824-3005 or visit Leviton’s website at www.leviton.com go to the terminal screw on the remote marked "YL/RD". Screw marked 2 Screw marked Black (BK) 3 White Black (BK) 3 1 4 2 Covered by one or more US & Foreign Patents and patents pending WIRING COORDINATING REMOTE (3-Way box): Terminal Screw marked 4 Terminal Screw marked 2 1 5 Green NOTE: Dress wires with a bend as shown in diagram in order to relieve stress when Copyright© 2007 Leviton Manufacturing Co., Inc. Connect wires per WIRING DIAGRAM as follows: Yellow/Red (YL/RD) YL/RD RD 5 Yellow/Red (YL/RD) YL/RD RD 6 3 mounting device. All Rights Including Trade Dress Rights Reserved NOTE: Maximum wire length from dimmer to last remote is 300 ft (90 m). Red 4 • Restore power at circuit breaker or fuse. Eco-10™ (Eco Series) is a trademark and Hi-lume® is a registered trademark of • Green or bare copper wire in wall box to Green terminal screw. Yellow/Red • See applicable operation section to ensure dimmer or switch is functioning properly. Lutron Electronics Inc. 5 • f lights do not turn ON, refer to the TROUBLESHOOTING section. I • Load wall box wire identified (tagged) when removing old switch to terminal screw marked "BK". • First Traveler wall box wire (note color as above) to terminal screw marked "RD". Coordinating Remote Coordinating Remote Step 7 Dimmer Remote Mounting: FCC COMPLIANCE STATEMENT This traveler from the remote must go to the terminal screw on the dimmer marked (no LEDs) (no LEDs) Control Turn off power at circuit breaker or fuse. This equipment has been tested and found to comply with the limits for a Class B "RD" or the Red dimmer lead. Hot (Black) Digital Device, pursuant to Part 15 of the FCC Rules. These limits are designed to • Second Traveler wall box wire (note color as above) to terminal screw marked WH BK WH BK White not used not used Black provide reasonable protection against harmful interference in a residential installation. "YL/RD". This traveler from the remote must go to the terminal screw on the Green Green Green This equipment generates, uses, and can radiate radio frequency energy and, if not dimmer marked "YL/RD" or the Yellow/Red dimmer lead. Black Ground Ground Ground installed and used in accordance with the instructions, may cause harmful interference • Remote terminal screw marked "WH" should have White insulation label affixed. RD not used YL/RD RD not used YL/RD Red YL/RD to radio communications. However, there is no guarantee that interference will not Line occur in a particular installation. If this equipment does cause harmful interference to NOTE: If insulating label is not affixed to terminal screw marked "WH", use Load 120VAC, 60Hz electrical tape to cover. Installation may now be completed by tightening radio or television reception, which can be determined by turning the equipment OFF • Proceed to Step 6. mounting screws into wall box. Attach wallplate. and ON, the user is encouraged to try to correct the interference by one or more of the White following measures: • Reorient or relocate the receiving Antenna. Neutral (White) • Increase the separation between the equipment and the receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Step 8 Restore Power: • Consult the dealer or an experienced radio/tv technician for help. Restore power at circuit breaker or fuse. Installation is complete. PK-93461-10-00-2A LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option, if within such five year period the product is returned prepaid, with proof of purchasedate, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered inany manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to fiveyears. Leviton is not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.
- Uploaded