1. NOTES:• If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet.• 1-scene controllers included into a Z-Wave®network must beupdated after you have included all other devices.• If using the VRCPGs Install Checklist feature, go directly to Step C.A) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Press the centerbutton to .B) If using VRCPG Programmer/Remote, you will be prompted to place1-scene controller into programming mode.C) To access Program mode, engage the air-gapswitch by gently pressing the top of the pushpad until the bottom lifts completely out of theframe and a click is heard (refer to figure).Wait 5 seconds and then press the push padback into the frame and hold push pad untilthe LED turns Amber. Release the push padand the LED should blink Amber. You are nowin Programming mode. NOTE: If the LED on the 1-scene controllerturns solid Red while including, there hasbeen a communication error.D) While standing close to the 1-scene controller(approximately 2-5 ft.), press the centerbutton on the Programmer/Remote to device in the network. NOTE: Onlyone device may be included at any time.E) The VRCPG Programmer/Remote will assign a Home ID, Node ID,and Name for this device. NOTE: This information will be stored in the Programmer/Remote tobe used for future reference. NOTE: You may edit the name of this device at this time.F) The 1-scene controller is now installed in the network.WARNINGS AND CAUTIONS:• ON/OFF LED for 2-way status reporting.• To be installed and/or used in accordance with appropriate electrical codes and regulations.• If you are unsure about any part of these instructions, consult a qualified electrician.• Vizia RF +TMVRCS1 1-Scene Controller does not control the load, but provides remote operation with Vizia RF +TMswitches.• Recommended minimum wall box depth is 2-1/2".WARNINGS AND CAUTIONS:• No traveler wires are needed. Remote controls via radio frequency (RF) technology.• Can call one (1) scene ON/OFF or area ON/OFF with advanced Programmer/Remote (see VRCPG).• For a complete set-up, a controller supporting the advanced Z-Wave® scene features is needed, such as the advanced Programming Remote (VRCPG).• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.1-Scene Controller/Virtual Matching Switch RemoteCat. No. VRCS1120VAC, 60HzInstallation InstructionsDI-000-VRCS1-02BTools needed to install your 1-Scene ControllerSlotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters RulerChanging the color of your 1-Scene Controller:Your device may include color options. To change color of the face,proceed as follows:Line up tabsand press insides one at atime to attachPush inside at tabto releaseINSTALLING YOUR 1-SCENE CONTROLLERNOTE: Use check boxes when Steps are completed.WARNING: TO AVOID FIRE, SHOCK OR DEATH; TURNOFF POWER at circuit breaker or fuse and test that power is offbefore wiring!Step 1Step 3 Preparing and connecting wires:This 1-scene controller can be wired using side wire terminalscrews or through backwire openings. Choose appropriate wirestripping specifications accordingly.• Make sure that the ends of the wires from the wall box are straight (cut if necessary).5/8"(1.6 cm)Strip Gage(measure barewire here)Cut(if necessary)Side Wire ConnectionSide wire terminals accept #14AWG solid wire copper only.Back Wire (either hole may be used)Back wire openings use #14-12 AWGsolid wire copper only.WIRING 1-SCENE CONTROLLER:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot wall box wire to terminal screw marked "BK".• Line Neutral wall box wire to terminal screw marked "WH".• Proceed to Step 5.• Position all wires to provide room inoutlet wall box for device.• Ensure that the word “TOP” is facing upon device strap.• Partially screw in mounting screws inwall box mounting holes. NOTE: Dress wireswith a bend asshown in diagramin order to relievestress whenmounting device.• Restore power at circuit breaker or fuse.• LED should turn ON. If LED does not turn ON, refer to theTROUBLESHOOTING section.Testing your 1-Scene Controller prior tomounting in wall box:Step 5Gently press topof push padWiring Application:Hot (Black)Neutral (White)Line120VAC, 60HzBKWHGreenGround1-Scene ControllerStep 423121. Line (Hot)2. Neutral3. GroundIdentifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble thisconfiguration, consult a qualified electrician.Step 2INTRODUCTIONLeviton’s Vizia RF +TMcomponents are designed to communicatewith each other via Radio Frequency (RF) to provide remote controlof your lighting. Using RF technology allows Leviton to provide thegreatest signal integrity possible. Each module in Leviton’s Vizia RF +TMcomponent line is a Z-Wave®enabled device. In a Z-Wave®network,each device is designed to act as a router. These routers will re-transmitthe RF signal from one device to another until the intended deviceis reached. This ensures that the signal is received by its intendeddevice by routing the signal around obstacles and radio dead spots.This 1-Scene controller is meant to control special scene enabledZ-Wave®products. To control groups of devices that are mixed or donot support scene command class use the Leviton 1-Zone Controller(VRCZ1). Setting up this device requires specific advanced controllerfunctionalities, your controller must be able to associate device to groupsand must be able to control the scene controller configuration commandssuch as the advanced Programming Remote (VRCPG).• This is a Z-Wave®Controller• 3-way or 4-way control without traveler wires• Can call 1 scene• ON/OFF LED• Two way communication• RF reliability• Ease of installation – No new wiring• Compatible with other Z-Wave®enabled devicesFEATURESIncluding 1-Scene Controller into Z-Wave®Network:Step 8Restore Power:Restore power at circuit breaker or fuse.Installation is complete.1-Scene Controller Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.Step 6Installation may now be completed bytightening mounting screws into wall box.Attach wallplate.Step 7
2. Device Association:After inclusion process, you must associate the devicesto the controllers. Refer to the Primary Programmer/Remote instruction sheet for complete details.A) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Scroll down to and press the center button.B) If using VRCPG Programmer/Remote, you will be prompted to place1-scene controller into programming mode.C) To access Program mode, engage the air-gap switch by gentlypressing the top of the push pad until the bottom lifts completely outof the frame and a click is heard (refer to figure). Wait 5 secondsand then press the push pad back into the frame and hold pushpad until the LED turns Amber. Release the push pad and the LEDshould blink Amber. You are now in Programming mode. NOTE: If the LED on the 1-scene controller turns solid Red whileexcluding, there has been a communication error.D) While standing close to the 1-scene controller (approximately 2-5 ft.),press the center button to device from the network.Factory Default:If your 1-scene controller is not responding, or you are unable to controlit after you have tried to Include/Exclude it multiple times, it may benecessary to reset the 1-scene controller to its original factory settings.To accomplish this, proceed as follows:• On the 1-scene controller, engage the air-gapswitch by gently pressing the top of the pushpad until the bottom lifts completely out of theframe and a click is heard (refer to figure). Wait5 seconds and then press the push pad back intothe frame and hold push pad until the locator LEDturns Amber and then flashes Red. Release thepush pad. The 1-scene controller is now reset.Once the controller is reset, it will be necessary toRe-Include it to a network before it can be used.CAUTION: SETTING A DEVICE TO A FACTORYDEFAULT DOES NOT EXCLUDE THAT DEVICEFROM A NETWORK. THE EXCLUSIONPROCEDURE MUST STILL BE FOLLOWED TOREMOVE THE DEVICE FROM THE PRIMARYPROGRAMMER/REMOTES INFORMATION TABLE. FAILURE TO DOSO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND, OR MAYFAIL TO RESPOND TO SOME DEVICES.DI-000-VRCS1-02B© 2009 Leviton Mfg. Co., Inc.LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 201 North Service Road, Melville, New York 11747. This warranty excludes and there is disclaimed liability for laborfor removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or impliedwarranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.Programmer/RemoteCat. No. VRCPGNOTE: Programmer/Remote must bein close proximity to 1-scene controllerwhen including in the network.Step 9 Excluding 1-Scene Controller fromZ-Wave®Network:For additional information, contact Leviton’sTechline at 1-800-824-3005 or visit Leviton’swebsite at www.ViziaRFplus.comProtected under U.S. Patent Number 6,388,399 and patents pending andlicensed under U.S. Patents Numbers 5,905,442, and 5,982,103PushPadLEDScene Application:Push Pad (Default settings)Turn ON from OFF position:Tap – Scene is activated, Scene LED turns ON.Turn OFF from ON position:Tap – Scene is no longer activated, Scene LEDturns OFF.Virtual Matching Remote Application:Push Pad (Default settings)Turn ON from OFF position:Tap – Lights turn ON, LED turns OFF.Turn OFF from ON position:Tap – Lights turn OFF, LED turns ON.OPERATIONTROUBLESHOOTING• Locator LED on controller does not turn ON - Circuit breaker or fuse has tripped. - If 1-scene controller is powered up and LED does not turn ON, check wiring.• Scene controller does not operate lights - Check association. - Ensure that controller was properly updated. - Re-configure the controller button to operate using the AREA ON/OFFaction (refer to VRCPG documentation).Step 10NOTE: This step requires a controller that can create association lists togroup 1.NOTE: One (1) Z-Wave®device can be associated to multiple programmer/remotes (up to five (5) programmer/remotes maximum).NOTE: If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for Associating a device.Once association is complete, you can set a scene asfollows:• Press and hold button on 1-Scene Controller until LED blinks Green.• Adjust devices in area.• Press button again on 1-Scene Controller and the LED will stop blinking.• The scene has now been set.Definition of ModeLED Option: Sets the Locator LED timeout to 5 seconds after use.NOTE: The switch will exit program mode after 3 minutes of inactivity.To enter programming mode press and hold the push pad for 10 secondsuntil the locator LED begins to blink. Upon releasing the push pad the LEDOption will automatically be changed.ADVANCED PROGRAMMING FEATURESLOCATOR LEDDefaultFirst toggleActiveTurns off 5 seconds after useLOCATOR LED OPTION SETTINGGently press topof push padG) After all devices are included into the network, the controller mustbe updated to allow proper network function. To update controllerproceed as follows: • If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for updating controller. • If using Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select SystemSetup Menu. Press the centerbutton to select Network. Pressthe center button to select Update"cntrl". When prompted, press pushpad on the 1-scene controller. • Wait until the VRCPG Programmer/Remote confirms completion. Update is done.Note: If using the VRCPGs InstallChecklist feature, after all devices areincluded, go to Update Controllers step.Note: If the 1-scene controller has been successfully Included in the network and the user tries to Include it again without first excluding it from thenetwork, the controller will retainthe first node ID it had received andignore the second.Cat. No. VRCPG1 ON2 ON3 ON4 ONOFFOFFOFFOFFMenuButtonCenterButtonIncluding 1-Scene Controller into Z-Wave®Network:Step 8 contdThis device complies with Part 15 of the FCC Rules. Operation is subjectto following two conditions: (1) this device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation of the device.This equipment has been tested and found to comply with the limits fora Class B Digital Device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses,and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference willnot occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determinedby turning the equipment OFF and ON, the user is encouraged to try tocorrect the interference by one or more of the following measures:• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.FCC COMPLIANCE STATEMENTAny changes or modifications not expressly approved by LevitonManufacturing Co., Inc., could void the users authority to operate theequipment.FCC CAUTIONStep 11b Mixed group or device that does not supportscene:NOTE: This step requires a 1-Zone Controller or Z-Wave®Controller that supports Z-Wave®scene controller configurationcommands.AREA ON/OFF Application:Push ButtonTurn ON from OFF position:Press button – Turns all lights in Zone/Area ON, LED turns ON.LED will blink until Zone/Area is ON.Turn OFF from ON position:Press button – Turns all lights in Zone/Area OFF, LED turns OFF.Dim/Bright:Press left side of Dim/Bright button - Lights in last activated Zone/Area willdim.Press right side of Dim/Bright button - Lights in last activated Zone/Area willbrighten.NOTE: Controller will only Dim/Bright devices located within direct RadioFrequency range.NOTE: LED will be lit Green if any one load in the associated Area is ON.LED will be OFF when all loads are turned OFF.If there is a power outage, when the power is restored, the lights will returnto the last setting before the power interruption.Cleaning: Clean with a damp cloth. DO NOT use chemical cleaners.Scene Programming:NOTE: All devices associated to the buttons must supportZ-Wave®scene command. If a device in the group does notsupport the scene command it will not be controlled.• Press and hold button on 1-Scene Controller until LEDblinks Green.• Adjust devices associated to the button.• Press button again on 1-Scene Controller and the LED willstop blinking.• The scene has now been set.Step 11a


Uploaded