1. Including 1-Zone Controller into Z-Wave®Network:NOTES:• If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for Including a device.• 1-zone controllers included into a Z-Wave®network must be updatedafter you have included all other devices.• If using the VRCPGs Install Checklist feature, go directly to Step C.A) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Press the centerbutton to .B) If using VRCPG Programmer/Remote, you will be prompted to place1-zone controller into programming mode.C) To access Program mode, engage the air-gapswitch by gently pressing the top of the pushpad until the bottom lifts completely out of theframe and a click is heard (refer to figure).Wait 5 seconds and then press the push padback into the frame and hold push pad untilthe LED turns Amber. Release the push padand the LED should blink Amber. You are nowin Programming mode. NOTE: If the LED on the 1-zone controllerturns solid Red while including, there hasbeen a communication error.D) While standing close to the 1-zone controller(approximately 2-5 ft.), press the centerbutton on the Programmer/Remote to device in the network. NOTE: Onlyone device may be included at any time.E) The VRCPG Programmer/Remote will assign a Home ID, Node IDand Name for this device. NOTE: This information will be stored in the Programmer/Remote tobe used for future reference. NOTE: You may name or edit the node of this device at this time.F) The 1-zone controller is now installed in the network.WARNINGS AND CAUTIONS:• ON/OFF LED and Brightness level LED for 2-way status reporting. • To be installed and/or used in accordance with appropriate electrical codes and regulations.• If you are unsure about any part of these instructions, consult a qualified electrician.• Vizia RF +TMVRCZ1 1-Zone Dimming Controller does not control the load, but provides 3-way or 4-way applications to operate with Vizia RF +TMdimmer.WARNINGS AND CAUTIONS:• Recommended minimum wall box depth is 2-1/2".• No traveler wires are needed. Remote controls via radio frequency (RF) technology.• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.1-Zone Dimming Controller/Virtual Matching Dimmer RemoteCat. No. VRCZ1120VAC, 60HzInstallation InstructionsDI-000-VRCZ1-02AChanging the color of your 1-Zone Controller:Your device may include color options. To change color of the face,proceed as follows:Push inside at tabto releaseINSTALLING YOUR 1-ZONE CONTROLLERNOTE: Use check boxes when Steps are completed.WIRING 1-ZONE CONTROLLER:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot wall box wire to terminal screw marked "BK".• Line Neutral wall box wire to terminal screw marked "WH".• Proceed to Step 5.Step 8Wiring Application:Hot (Black)Neutral (White)BKWHGreenGroundLine120VAC, 60Hz1-Zone ControllerStep 4Testing your 1-Zone Controller prior to mountingin wall box:• Position all wires to provide room inoutlet wall box for device.• Ensure that the word “TOP” is facing upon device strap.• Partially screw in mounting screws inwall box mounting holes. NOTE: Dress wireswith a bend asshown in diagramin order to relievestress whenmounting device.• Restore power at circuit breaker or fuse.• LED should turn ON. If LED does not turn ON, refer to theTROUBLESHOOTING section.Step 5WARNING: TO AVOID FIRE SHOCK OR DEATH; TURNOFF POWER at circuit breaker or fuse and test that power isoff before wiring!Step 1Step 3 Preparing and connecting wires:This 1-zone controller can be wired using side wire terminalscrews or through backwire openings. Choose appropriate wirestripping specifications accordingly.• Make sure that the ends of the wires from the wall box are straight (cut if necessary).5/8"(1.6 cm)Strip Gage(measure barewire here)Cut(if necessary)Side Wire ConnectionSide wire terminals accept #14AWG solid wire copper only.Back Wire (either hole may be used)Back wire openings use #14-12 AWGsolid wire copper only.23121. Line (Hot)2. Neutral3. GroundIdentifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble thisconfiguration, consult a qualified electrician.Step 2INTRODUCTIONLeviton’s Vizia RF +TMcomponents are designed to communicatewith each other via Radio Frequency (RF) to provide remote controlof your lighting. Using RF technology allows Leviton to provide thegreatest signal integrity possible. Each module in Leviton’s Vizia RF +TMcomponent line is a Z-Wave®enabled device. In a Z-Wave®network,each device is designed to act as a router. These routers will re-transmitthe RF signal from one device to another until the intended device isreached. This ensures that the signal is received by its intended deviceby routing the signal around obstacles and radio dead spots. The 1-ZoneDimming Controller/Virtual Matching Dimmer Remote is compatible withany Z-Wave®enabled network, regardless of the manufacturer and canalso be used with other devices displaying the Z-Wave®logo.• This is a Z-Wave®Controller• 3-way or 4-way control without traveler wires• Controls dimming of remote load• ON/OFF LED and Brightness level LED• Two way communication• RF reliability• Ease of installation – No new wiring• Compatible with other Z-Wave®enabled devicesFEATURESTools needed to install your 1-Zone ControllerSlotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters RulerLine up tabsand press insides one at atime to attachGently press topof push padRestore Power:Restore power at circuit breaker or fuse.Installation is complete.Step 71-Zone Controller Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.Installation may now be completed bytightening mounting screws into wall box.Attach wallplate.Step 6
2. Excluding 1-Zone Controller fromZ-Wave®Network:Including 1-Zone Controller intoZ-Wave®Network:Factory Default:If your 1-zone controller is not responding, or you are unable to control itafter you have tried to Include/Exclude it multiple times, it may be necessaryto reset the 1-zone controller to its original factory settings. To accomplishthis, proceed as follows:• On the 1-zone controller, engage the air-gap switch by gently pressingthe top of the push pad until the bottom lifts completely out of the frameand a click is heard (refer to figure). Wait 5seconds and then press the push pad back intothe frame and hold push pad until the locator LEDturns Amber and then turns Red. Release thepush pad. The 1-zone controller is now reset.Once the controller is reset, it will be necessary toRe-Include it to a network before it can be used.CAUTION: SETTING A DEVICE TO A FACTORYDEFAULT DOES NOT EXCLUDE THAT DEVICEFROM A NETWORK. THE EXCLUSIONPROCEDURE MUST STILL BE FOLLOWED TOREMOVE THE DEVICE FROM THE PRIMARYPROGRAMMER REMOTE’S INFORMATIONTABLE. FAILURE TO DO SO MAY RESULT INSYSTEM THAT IS SLOW TO RESPOND, OR MAYFAIL TO RESPOND TO SOME DEVICES.DI-000-VRCZ1-02A2008 © Leviton Mfg. Co., Inc.LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liabilityfor labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other orimplied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.Step 8 contdProgrammer/RemoteCat. No. VRCPGNOTE: Programmer/Remote must be inclose proximity to 1-zone controller whenincluding in the network.For additional information, contact Leviton’sTechline at 1-800-824-3005 or visit Leviton’swebsite at www.ViziaRFplus.comProtected under U.S. Patent Number 6,388,399 and patents pending andlicensed under U.S. Patents Numbers 5,905,442, and 5,982,103This equipment has been tested and found to comply with the limits fora Class B Digital Device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses,and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference willnot occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determinedby turning the equipment OFF and ON, the user is encouraged to try tocorrect the interference by one or more of the following measures:• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.FCC COMPLIANCE STATEMENTA) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Scroll down andpress the center button to .B) If using VRCPG Programmer/Remote, you will be prompted to place1-zone controller into programming mode.C) To access Program mode, engage the air-gap switch by gentlypressing the top of the push pad until the bottom lifts completely outof the frame and a click is heard (refer to figure). Wait 5 secondsand then press the push pad back into the frame and hold pushpad until the LED turns Amber. Release the push pad and the LEDshould blink Amber. You are now in Programming mode. NOTE: If the LED on the 1-zone controller turns solid Red whileexcluding, there has been a communication error.D) While standing close to the 1-zone controller (approximately 2-5 ft.),press the center button on the Programmer/Remote to device from the network.Step 9TROUBLESHOOTING• Locator LED on controller does not turn ON - Circuit breaker or fuse has tripped. - If 1-zone controller is powered up and LED does not turn ON, check wiring.• Zone controller does not operate lights - Check association. - Ensure that controller was properly updated.OPERATIONDIM/BRIGHT BarBRIGHTEN:Press the right half of the DIM/BRIGHT Bar– Lights brighten to desired level.DIM:Press the left half of the DIM/BRIGHT Bar– Lights dim to desired level.If there is a power outage, when the power isrestored, the lights will return to the last settingbefore the power interruption.Cleaning: Clean with a damp cloth. DO NOTuse chemical cleaners.Virtual Matching Remote Application:Push Pad (Default settings)Turn ON from OFF position:Tap – Lights turn ON, LED turns OFF.Turn OFF from ON position:Tap – Lights turn OFF, LED turns ON.PushPadLEDDIM/BRIGHTBarLEDBrightnessDisplayDevice Association:After inclusion process, you must associate the devices tothe controllers. Refer to the Primary Programmer/Controllerinstruction sheet for complete details.Step 10NOTE: One (1) Z-Wave®device can be associated to multiple programmer/remotes (up to five (5) programmer/remotes maximum).NOTE: If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for Associating a device.NOTE: Only one Vizia RF +TMdimmer can be associated to the 1-zonecontroller.Gently press topof push padDefinition of ModeLED Options: Sets the time period in seconds the Locator LED andBrightness display will stay on before extinguishing.NOTE: The switch will exit program mode after 3 minutes of inactivity.Program ModeTo enter programming mode:Press and hold the push pad and then the right half of the DIM/BRIGHT bar (^) for 5 seconds until the Locator LED starts and the leftmost LED(LED 1) begin to blink.The Locator LED will blink once per second to indicate Program Mode,LED Options. To change LED Options settings use the DIM/BRIGHT bar tomove the LED to the desired preset setting according to the chart below. Bytapping the push pad, this setting will automatically be saved and the devicewill exit programming mode.ADVANCED PROGRAMMING FEATURESActiveActiveActiveActiveTurns off 5 seconds after useTurns off 5 seconds after useActiveActiveTurns off 5 seconds after useLOCATOR LED TIMEOUT1234567LEDTurns off 5 seconds after useTurns off 5 seconds after useLED Bar activeLED Bar turns off 5 seconds after useLED Bar turns off 5 seconds after useLED BRIGHTNESS DISPLAY OPTIONSG) After all devices are included into the network, the controller mustbe updated to allow proper network function. To update controllerproceed as follows: • If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for updating controller. • If using Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll downto System Setup. Press the centerbutton to select System Setup Menu.Choose Advanced Settings. Press thecenter button to select Network. Pressthe center button to select Update"cntrl". When prompted press push padon the 1-zone dimming controller. • Wait until the VRCPG Programmer/Remote confirms completion. Update isdone.Note: If using the VRCPGs Install Checklistfeature, after all devices are included, go toUpdate Controllers step.Note: If the 1-zone controller has beensuccessfully Included in the network andthe user tries to Include it again without firstexcluding it from the network, the controllerwill retain the first node ID it had received andignore the second.Cat. No. VRCPG1 ON2 ON3 ON4 ONOFFOFFOFFOFFMenuButtonCenterButton


Uploaded