Leviton VRCZ1-1LZ Installation Manual and Setup Guide

Including 1-Zone Controller into Z-Wave
®
Network:
NOTES:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for Including a device.
1-zone controllers included into a Z-Wave
®
network must be updated
after you have included all other devices.
If using the VRCPG's Install Checklist feature, go directly to Step C.
A)
If using a Leviton Z-Wave
®
Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Choose
Advanced
Settings. Press the center button to select Network. Press the center
button to <Include Node>.
B)
If using VRCPG Programmer/Remote, you will be prompted to place
1-zone controller into programming mode.
C)
To access Program mode, engage the air-gap
switch by gently pressing the top of the push
pad until the bottom lifts completely out of the
frame and a click is heard
(refer to figure)
.
Wait 5 seconds and then press the push pad
back into the frame and hold push pad until
the LED turns
Amber. Release the push pad
and the LED should blink
Amber.
You are now
in Programming mode.
NOTE:
If the LED on the 1-zone controller
turns solid Red while including, there has
been a communication error.
D)
While standing close to the 1-zone controller
(approximately 2-5 ft.), press the center
button on the Programmer/Remote to
<Include> device in the network.
NOTE:
Only
one device may be included at any time.
E)
The VRCPG Programmer/Remote will assign a Home ID, Node ID
and Name for this device.
NOTE:
This information will be stored in the Programmer/Remote to
be used for future reference.
NOTE:
You may name or edit the node of this device at this time.
F)
The 1-zone controller is now installed in the network
.
WARNINGS AND CAUTIONS
:
• ON/OFF LED and Brightness level LED for 2-way status reporting.
• To be installed and/or used in accordance with appropriate electrical codes and regulations.
• If you are unsure about any part of these instructions, consult a qualified electrician.
• Vizia RF +
TM
VRCZ1 1-Zone Dimming Controller does not control the load, but provides 3-way or 4-way applications to operate with Vizia RF +
TM
dimmer.
WARNINGS AND CAUTIONS
:
• Recommended minimum wall box depth is 2-1/2".
• No traveler wires are needed. Remote controls via radio frequency (RF) technology.
• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.
• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.
1-Zone Dimming Controller/
Virtual Matching Dimmer Remote
Cat. No. VRCZ1
120VAC, 60Hz
INSTAllATION INSTRUCTIONS
DI-000-VRCZ1-02A
Changing the color of your 1-Zone Controller:
Your device may include color options.
To change color of the face,
proceed as follows:
Push in
side at tab
to release
INSTAllING YOUR 1-ZONE CONTROllER
NOTE:
Use check boxes when Steps are completed.
WIRING 1-ZONE CONTROllER:
Connect wires per WIRING DIAGRAM as follows:
• Green or bare copper wire in wall box to Green terminal screw.
• Line Hot wall box wire to terminal screw marked "BK".
• Line Neutral wall box wire to terminal screw marked "WH".
Proceed to Step 5.
Step 8
Wiring Application:
Hot (Bla
c k )
Neutral (White)
BK
WH
Green
Ground
Line
120
V A C , 60H
z
1-Zone Controller
Step 4
Testing your 1-Zone Controller prior to mounting
in wall box:
• Position all wires to provide room in
outlet wall box for device.
• Ensure that the word “TOP” is facing up
on device strap.
• Partially screw in mounting screws in
wall box mounting holes.
NOTE:
Dress wires
with a bend as
shown in diagram
in order to relieve
stress when
mounting device.
• Restore power at circuit breaker or fuse.
• LED should turn ON.
If lED does not turn ON, refer to the
TROUBlESHOOTING section.
Step 5
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
/.
/&&
WARNING:
TO AVOID FIRE SHOCK OR DEATH; TURN
OFF POWER
at circuit breaker or fuse and test that power is
off before wiring!
Step 1
Step 3
Preparing and connecting wires:
This 1-zone controller can be wired using side wire terminal
screws or through backwire openings. Choose appropriate wire
stripping specifications accordingly.
• Make sure that the ends of the wires from the wall box are
straight (cut if necessary).
5/8"
(1.6 cm)
Strip Gage
(measure bare
wire here)
Cut
(if necessary)
Side Wire Connection
Side wire terminals accept #14
AWG
solid wire copper only
.
Back Wire (either hole may be used)
Back wire openings use #14-12
AWG
solid wire copper only
.
2
3
1
2
1.
Line (Hot)
2.
Neutral
3.
Ground
Identifying your wiring application (most common):
NOTE:
If the wiring in your wall box does not resemble this
configuration, consult a qualified electrician.
Step 2
INTRODUCTION
Leviton’s Vizia RF +
TM
components are designed to communicate
with each other via Radio Frequency (RF) to provide remote control
of your lighting. Using RF technology allows Leviton to provide the
greatest signal integrity possible. Each module in Leviton’s Vizia RF +
TM
component line is a Z-Wave
®
enabled device. In a Z-Wave
®
network,
each device is designed to act as a router.
These routers will re-transmit
the RF signal from one device to another until the intended device is
reached.
This ensures that the signal is received by its intended device
by routing the signal around obstacles and radio dead spots.
The 1-Zone
Dimming Controller/Virtual Matching Dimmer Remote is compatible with
any Z-Wave
®
enabled network, regardless of the manufacturer and can
also be used with other devices displaying the Z-Wave
®
logo.
• This is a Z-Wave
®
Controller
• 3-way or 4-way control without traveler wires
• Controls dimming of remote load
• ON/OFF LED and Brightness level LED
• Two way communication
• RF reliability
• Ease of installation – No new wiring
• Compatible with other Z-Wave
®
enabled devices
FEATURES
Tools needed to install your 1-Zone Controller
Slotted/Phillips Screwdriver
Electrical
Tape
Pliers
Pencil
Cutters
Ruler
line up tabs
and press in
sides one at a
time to attach
Gently press top
of push pad
Restore Power:
Restore power at circuit breaker or fuse.
Installation is complete.
Step 7
1-Zone Controller Mounting:
TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.
Installation may now be completed by
tightening mounting screws into wall box.
Attach wallplate.
Step 6
Excluding 1-Zone Controller from
Z-Wave
®
Network:
Including 1-Zone Controller into
Z-Wave
®
Network:
Factory Default:
If your 1-zone controller is not responding, or you are unable to control it
after you have tried to Include/Exclude it multiple times, it may be necessary
to reset the 1-zone controller to its original factory settings.
To accomplish
this, proceed as follows:
• On the 1-zone controller, engage the air-gap switch by gently pressing
the top of the push pad until the bottom lifts completely out of the frame
and a click is heard
(refer to figure)
. Wait 5
seconds and then press the push pad back into
the frame and hold push pad until the locator LED
turns
Amber and then turns Red. Release the
push pad.
The 1-zone controller is now reset.
Once the controller is reset, it will be necessary to
Re-Include it to a network before it can be used.
CAUTION:
SETTING
A DEVICE
TO
A FACTORY
DEFAULT
DOES NOT
EXCLUDE
THAT
DEVICE
FROM
A NETWORK.
THE EXCLUSION
PROCEDURE MUST
STILL
BE FOLLOWED
TO
REMOVE
THE DEVICE FROM
THE PRIMARY
PROGRAMMER REMOTE’S INFORMATION
TABLE. FAILURE
TO DO SO MAY
RESULT
IN
SYSTEM
THAT
IS SLOW
TO RESPOND, OR MAY
FAIL
TO RESPOND
TO SOME DEVICES.
DI-000-VRCZ1-02A
2008 © Leviton Mfg. Co., Inc.
lIMITED 5 YEAR WARRANTY AND EXClUSIONS
Leviton
warrants
to
the
original
consumer
purchaser
and
not
for
the
benefit
of
anyone
else
that
this
product
at
the
time
of
its
sale
by
Leviton
is
free
of
defects
in
materials
and
workmanship
under
normal
and
proper
use
for
five
years
from
the
purchase
date.
Leviton’s
only
obligation
is
to
correct
such
defects
by
repair
or
replacement,
at
its
option,
if within
such
five
year
period
the
product
is
returned
prepaid,
with
proof
of
purchase
date,
and
a description
of
the
problem
to
leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25
little Neck Parkway,
little Neck, New York 11362-2591.
This
warranty
excludes
and
there
is
disclaimed
liability
for
labor
for
removal
of
this
product
or
reinstallation.
This
warranty
is
void
if this
product
is
installed
improperly
or
in
an
improper
environment,
overloaded,
misused,
opened,
abused,
or
altered
in
any
manner,
or
is
not
used
under
normal
operating
conditions
or
not
in
accordance
with
any
labels
or
instructions.
There are no other or
implied warranties of any kind, including merchantability and fitness for a particular purpose
, but
if any
implied
warranty
is
required
by
the
applicable
jurisdiction,
the
duration
of
any
such
implied
warranty,
including
merchantability
and
fitness
for
a particular
purpose,
is
limited
to
five
years.
leviton is not liable for incidental,
indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation
. The
remedies
provided
herein
are
the
exclusive
remedies
under
this
warranty,
whether
based
on
contract,
tort
or
otherwise.
Step 8 cont'd
Programmer/Remote
Cat. No. VRCPG
NOTE:
Programmer/Remote must be in
close proximity to 1-zone controller when
including in the network.
For additional information, contact leviton’s
Techline at 1-800-824-3005 or visit leviton’s
website at www.ViziaRFplus.com
Protected under U.S. Patent Number 6,388,399 and patents pending and
licensed under U.S. Patents Numbers 5,905,442, and 5,982,103
This equipment has been tested and found to comply with the limits for
a Class B Digital Device, pursuant to Part 15 of the FCC Rules.
These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will
not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined
by turning the equipment OFF and ON, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving
Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/tv technician for help.
FCC COMPlIANCE
STATEMENT
A)
If using a Leviton Z-Wave
®
Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down to System Setup. Press
the center button to select System Setup Menu. Choose
Advanced
Settings. Press the center button to select Network. Scroll down and
press the center button to <Exclude Node>.
B)
If using VRCPG Programmer/Remote, you will be prompted to place
1-zone controller into programming mode.
C)
To access Program mode, engage the air-gap switch by gently
pressing the top of the push pad until the bottom lifts completely out
of the frame and a click is heard
(refer to figure)
. Wait 5 seconds
and then press the push pad back into the frame and hold push
pad until the LED turns
Amber. Release the push pad and the LED
should blink
Amber.
You are now in Programming mode.
NOTE:
If the LED on the 1-zone controller turns solid Red while
excluding, there has been a communication error.
D)
While standing close to the 1-zone controller (approximately 2-5 ft.),
press the center button on the Programmer/Remote to <Exclude>
device from the network.
Step 9
TROUBlESHOOTING
• Locator LED on controller does not turn ON
- Circuit breaker or fuse has tripped.
- If 1-zone controller is powered up and LED does not turn ON,
check wiring.
• Zone controller does not operate lights
- Check association.
- Ensure that controller was properly updated.
OPERATION
DIM/BRIGHT Bar
BRIGHTEN:
Press the right half of the DIM/BRIGHT
Bar
– Lights brighten to desired level.
DIM:
Press the left half of the DIM/BRIGHT
Bar
– Lights dim to desired level.
If there is a power outage, when the power is
restored, the lights will return to the last setting
before the power interruption.
Cleaning:
Clean with a damp cloth.
DO NOT
use chemical cleaners.
Virtual Matching Remote Application:
Push Pad (Default settings)
Turn ON from OFF position:
Tap – Lights turn ON, LED turns OFF.
Turn OFF from ON position:
Tap – Lights turn OFF, LED turns ON.
Push
Pad
lED
DIM/
BRIGHT
Bar
lED
Brightness
Display
Device Association:
After inclusion process, you must associate the devices to
the controllers. Refer to the Primary Programmer/Controller
instruction sheet for complete details.
Step 10
NOTE:
One (1) Z-Wave
®
device can be associated to multiple programmer/
remotes (up to five (5) programmer/remotes maximum).
NOTE:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for
Associating a device.
NOTE: Only one Vizia RF +
TM
dimmer can be associated to the 1-zone
controller.
Gently press top
of push pad
Definition of Mode
LED Options:
Sets the time period in seconds the Locator LED and
Brightness display will stay on before extinguishing.
NOTE:
The switch will exit program mode after 3 minutes of inactivity.
Program Mode
To enter programming mode:
Press and hold the push pad and then the
right
half of the DIM/BRIGHT
bar
(
^
)
for 5 seconds until the Locator LED starts and the leftmost LED
(LED 1) begin to blink.
The Locator LED will blink once per second to indicate Program Mode,
lED Options
. To change LED Options settings use the DIM/BRIGHT
bar to
move the LED to the desired preset setting according to the chart below. By
tapping the push pad, this setting will automatically be saved and the device
will exit programming mode.
ADVANCED PROGRAMMING FEATURES
Active
Active
Active
Active
Tu
rns of
f 5 seconds after use
Tu
rns of
f 5 seconds after use
Active
Active
Tu
rns of
f 5 seconds after use
LOCA
TOR LED TIMEOUT
1
2
3
4
5
6
7
LED
Tu
rns of
f 5 seconds after use
Tu
rns of
f 5 seconds after use
LED Bar active
LED Bar turns of
f 5 seconds after use
LED Bar turns of
f 5 seconds after use
LED BRIGHTNESS DISPLA
Y OPTIONS
G)
After all devices are included into the network, the controller must
be updated to allow proper network function.
To update controller
proceed as follows:
If using a non-Leviton Programmer/Remote, refer to the
Programmer/Remote instruction sheet for updating controller.
If using Leviton Z-Wave
®
Programmer/Remote, Cat. No. VRCPG,
press the Menu button and scroll down
to System Setup. Press the center
button to select System Setup Menu.
Choose
Advanced Settings. Press the
center button to select Network. Press
the center button to select Update
"cntrl". When prompted press push pad
on the 1-zone dimming controller.
Wait until the VRCPG Programmer/
Remote confirms completion. Update is
done.
NOTE:
I
f using the VRCPG's Install Checklist
feature, after all devices are included, go to
Update Controllers step.
NOTE:
If the 1-zone controller has been
successfully Included in the network and
the user tries to Include it again without first
excluding it from the network, the controller
will retain the first node ID it had received and
ignore the second.
Cat. No. VRCPG
1
ON
2
ON
3
ON
4
ON
OFF
OFF
OFF
OFF
Menu
Button
Center
Button
of 2


Related Products

Leviton VRCZ1-1LZ - 1-Button Zone Dimming Z-Wave Controller
Leviton VRCZ1-1LZ
1-Button Zone Dimming Z-Wave Controller

Related Categories


Document Transcript

1. Including 1-Zone Controller into Z-Wave®Network:NOTES:• If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for Including a device.• 1-zone controllers included into a Z-Wave®network must be updatedafter you have included all other devices.• If using the VRCPGs Install Checklist feature, go directly to Step C.A) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Press the centerbutton to .B) If using VRCPG Programmer/Remote, you will be prompted to place1-zone controller into programming mode.C) To access Program mode, engage the air-gapswitch by gently pressing the top of the pushpad until the bottom lifts completely out of theframe and a click is heard (refer to figure).Wait 5 seconds and then press the push padback into the frame and hold push pad untilthe LED turns Amber. Release the push padand the LED should blink Amber. You are nowin Programming mode. NOTE: If the LED on the 1-zone controllerturns solid Red while including, there hasbeen a communication error.D) While standing close to the 1-zone controller(approximately 2-5 ft.), press the centerbutton on the Programmer/Remote to device in the network. NOTE: Onlyone device may be included at any time.E) The VRCPG Programmer/Remote will assign a Home ID, Node IDand Name for this device. NOTE: This information will be stored in the Programmer/Remote tobe used for future reference. NOTE: You may name or edit the node of this device at this time.F) The 1-zone controller is now installed in the network.WARNINGS AND CAUTIONS:• ON/OFF LED and Brightness level LED for 2-way status reporting. • To be installed and/or used in accordance with appropriate electrical codes and regulations.• If you are unsure about any part of these instructions, consult a qualified electrician.• Vizia RF +TMVRCZ1 1-Zone Dimming Controller does not control the load, but provides 3-way or 4-way applications to operate with Vizia RF +TMdimmer.WARNINGS AND CAUTIONS:• Recommended minimum wall box depth is 2-1/2".• No traveler wires are needed. Remote controls via radio frequency (RF) technology.• Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.• Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.1-Zone Dimming Controller/Virtual Matching Dimmer RemoteCat. No. VRCZ1120VAC, 60HzInstallation InstructionsDI-000-VRCZ1-02AChanging the color of your 1-Zone Controller:Your device may include color options. To change color of the face,proceed as follows:Push inside at tabto releaseINSTALLING YOUR 1-ZONE CONTROLLERNOTE: Use check boxes when Steps are completed.WIRING 1-ZONE CONTROLLER:Connect wires per WIRING DIAGRAM as follows:• Green or bare copper wire in wall box to Green terminal screw.• Line Hot wall box wire to terminal screw marked "BK".• Line Neutral wall box wire to terminal screw marked "WH".• Proceed to Step 5.Step 8Wiring Application:Hot (Black)Neutral (White)BKWHGreenGroundLine120VAC, 60Hz1-Zone ControllerStep 4Testing your 1-Zone Controller prior to mountingin wall box:• Position all wires to provide room inoutlet wall box for device.• Ensure that the word “TOP” is facing upon device strap.• Partially screw in mounting screws inwall box mounting holes. NOTE: Dress wireswith a bend asshown in diagramin order to relievestress whenmounting device.• Restore power at circuit breaker or fuse.• LED should turn ON. If LED does not turn ON, refer to theTROUBLESHOOTING section.Step 5WARNING: TO AVOID FIRE SHOCK OR DEATH; TURNOFF POWER at circuit breaker or fuse and test that power isoff before wiring!Step 1Step 3 Preparing and connecting wires:This 1-zone controller can be wired using side wire terminalscrews or through backwire openings. Choose appropriate wirestripping specifications accordingly.• Make sure that the ends of the wires from the wall box are straight (cut if necessary).5/8"(1.6 cm)Strip Gage(measure barewire here)Cut(if necessary)Side Wire ConnectionSide wire terminals accept #14AWG solid wire copper only.Back Wire (either hole may be used)Back wire openings use #14-12 AWGsolid wire copper only.23121. Line (Hot)2. Neutral3. GroundIdentifying your wiring application (most common):NOTE: If the wiring in your wall box does not resemble thisconfiguration, consult a qualified electrician.Step 2INTRODUCTIONLeviton’s Vizia RF +TMcomponents are designed to communicatewith each other via Radio Frequency (RF) to provide remote controlof your lighting. Using RF technology allows Leviton to provide thegreatest signal integrity possible. Each module in Leviton’s Vizia RF +TMcomponent line is a Z-Wave®enabled device. In a Z-Wave®network,each device is designed to act as a router. These routers will re-transmitthe RF signal from one device to another until the intended device isreached. This ensures that the signal is received by its intended deviceby routing the signal around obstacles and radio dead spots. The 1-ZoneDimming Controller/Virtual Matching Dimmer Remote is compatible withany Z-Wave®enabled network, regardless of the manufacturer and canalso be used with other devices displaying the Z-Wave®logo.• This is a Z-Wave®Controller• 3-way or 4-way control without traveler wires• Controls dimming of remote load• ON/OFF LED and Brightness level LED• Two way communication• RF reliability• Ease of installation – No new wiring• Compatible with other Z-Wave®enabled devicesFEATURESTools needed to install your 1-Zone ControllerSlotted/Phillips Screwdriver Electrical Tape Pliers Pencil Cutters RulerLine up tabsand press insides one at atime to attachGently press topof push padRestore Power:Restore power at circuit breaker or fuse.Installation is complete.Step 71-Zone Controller Mounting:TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.Installation may now be completed bytightening mounting screws into wall box.Attach wallplate.Step 6
2. Excluding 1-Zone Controller fromZ-Wave®Network:Including 1-Zone Controller intoZ-Wave®Network:Factory Default:If your 1-zone controller is not responding, or you are unable to control itafter you have tried to Include/Exclude it multiple times, it may be necessaryto reset the 1-zone controller to its original factory settings. To accomplishthis, proceed as follows:• On the 1-zone controller, engage the air-gap switch by gently pressingthe top of the push pad until the bottom lifts completely out of the frameand a click is heard (refer to figure). Wait 5seconds and then press the push pad back intothe frame and hold push pad until the locator LEDturns Amber and then turns Red. Release thepush pad. The 1-zone controller is now reset.Once the controller is reset, it will be necessary toRe-Include it to a network before it can be used.CAUTION: SETTING A DEVICE TO A FACTORYDEFAULT DOES NOT EXCLUDE THAT DEVICEFROM A NETWORK. THE EXCLUSIONPROCEDURE MUST STILL BE FOLLOWED TOREMOVE THE DEVICE FROM THE PRIMARYPROGRAMMER REMOTE’S INFORMATIONTABLE. FAILURE TO DO SO MAY RESULT INSYSTEM THAT IS SLOW TO RESPOND, OR MAYFAIL TO RESPOND TO SOME DEVICES.DI-000-VRCZ1-02A2008 © Leviton Mfg. Co., Inc.LIMITED 5 YEAR WARRANTY AND EXCLUSIONSLeviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to Leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 Little Neck Parkway, Little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liabilityfor labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other orimplied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. Leviton is not liable for incidental,indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.Step 8 contdProgrammer/RemoteCat. No. VRCPGNOTE: Programmer/Remote must be inclose proximity to 1-zone controller whenincluding in the network.For additional information, contact Leviton’sTechline at 1-800-824-3005 or visit Leviton’swebsite at www.ViziaRFplus.comProtected under U.S. Patent Number 6,388,399 and patents pending andlicensed under U.S. Patents Numbers 5,905,442, and 5,982,103This equipment has been tested and found to comply with the limits fora Class B Digital Device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, uses,and can radiate radio frequency energy and, if not installed and used inaccordance with the instructions, may cause harmful interference to radiocommunications. However, there is no guarantee that interference willnot occur in a particular installation. If this equipment does cause harmfulinterference to radio or television reception, which can be determinedby turning the equipment OFF and ON, the user is encouraged to try tocorrect the interference by one or more of the following measures:• Reorient or relocate the receiving Antenna.• Increase the separation between the equipment and the receiver.• Connect the equipment into an outlet on a circuit different from that towhich the receiver is connected.• Consult the dealer or an experienced radio/tv technician for help.FCC COMPLIANCE STATEMENTA) If using a Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll down to System Setup. Pressthe center button to select System Setup Menu. Choose AdvancedSettings. Press the center button to select Network. Scroll down andpress the center button to .B) If using VRCPG Programmer/Remote, you will be prompted to place1-zone controller into programming mode.C) To access Program mode, engage the air-gap switch by gentlypressing the top of the push pad until the bottom lifts completely outof the frame and a click is heard (refer to figure). Wait 5 secondsand then press the push pad back into the frame and hold pushpad until the LED turns Amber. Release the push pad and the LEDshould blink Amber. You are now in Programming mode. NOTE: If the LED on the 1-zone controller turns solid Red whileexcluding, there has been a communication error.D) While standing close to the 1-zone controller (approximately 2-5 ft.),press the center button on the Programmer/Remote to device from the network.Step 9TROUBLESHOOTING• Locator LED on controller does not turn ON - Circuit breaker or fuse has tripped. - If 1-zone controller is powered up and LED does not turn ON, check wiring.• Zone controller does not operate lights - Check association. - Ensure that controller was properly updated.OPERATIONDIM/BRIGHT BarBRIGHTEN:Press the right half of the DIM/BRIGHT Bar– Lights brighten to desired level.DIM:Press the left half of the DIM/BRIGHT Bar– Lights dim to desired level.If there is a power outage, when the power isrestored, the lights will return to the last settingbefore the power interruption.Cleaning: Clean with a damp cloth. DO NOTuse chemical cleaners.Virtual Matching Remote Application:Push Pad (Default settings)Turn ON from OFF position:Tap – Lights turn ON, LED turns OFF.Turn OFF from ON position:Tap – Lights turn OFF, LED turns ON.PushPadLEDDIM/BRIGHTBarLEDBrightnessDisplayDevice Association:After inclusion process, you must associate the devices tothe controllers. Refer to the Primary Programmer/Controllerinstruction sheet for complete details.Step 10NOTE: One (1) Z-Wave®device can be associated to multiple programmer/remotes (up to five (5) programmer/remotes maximum).NOTE: If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for Associating a device.NOTE: Only one Vizia RF +TMdimmer can be associated to the 1-zonecontroller.Gently press topof push padDefinition of ModeLED Options: Sets the time period in seconds the Locator LED andBrightness display will stay on before extinguishing.NOTE: The switch will exit program mode after 3 minutes of inactivity.Program ModeTo enter programming mode:Press and hold the push pad and then the right half of the DIM/BRIGHT bar (^) for 5 seconds until the Locator LED starts and the leftmost LED(LED 1) begin to blink.The Locator LED will blink once per second to indicate Program Mode,LED Options. To change LED Options settings use the DIM/BRIGHT bar tomove the LED to the desired preset setting according to the chart below. Bytapping the push pad, this setting will automatically be saved and the devicewill exit programming mode.ADVANCED PROGRAMMING FEATURESActiveActiveActiveActiveTurns off 5 seconds after useTurns off 5 seconds after useActiveActiveTurns off 5 seconds after useLOCATOR LED TIMEOUT1234567LEDTurns off 5 seconds after useTurns off 5 seconds after useLED Bar activeLED Bar turns off 5 seconds after useLED Bar turns off 5 seconds after useLED BRIGHTNESS DISPLAY OPTIONSG) After all devices are included into the network, the controller mustbe updated to allow proper network function. To update controllerproceed as follows: • If using a non-Leviton Programmer/Remote, refer to theProgrammer/Remote instruction sheet for updating controller. • If using Leviton Z-Wave®Programmer/Remote, Cat. No. VRCPG,press the Menu button and scroll downto System Setup. Press the centerbutton to select System Setup Menu.Choose Advanced Settings. Press thecenter button to select Network. Pressthe center button to select Update"cntrl". When prompted press push padon the 1-zone dimming controller. • Wait until the VRCPG Programmer/Remote confirms completion. Update isdone.Note: If using the VRCPGs Install Checklistfeature, after all devices are included, go toUpdate Controllers step.Note: If the 1-zone controller has beensuccessfully Included in the network andthe user tries to Include it again without firstexcluding it from the network, the controllerwill retain the first node ID it had received andignore the second.Cat. No. VRCPG1 ON2 ON3 ON4 ONOFFOFFOFFOFFMenuButtonCenterButton


Uploaded