I. DIMMER PROGRAMMING
SECTION A
Energy Save
- Set the maximum brightness level
for energy savings
Minimum Brightness Level
– Set the minimum
dimming level
Preset ON Level
– Set the turn on brightness level
regardless of the previous set light level (formerly Dim Lock)
Almost OFF Level
– Sets the brightness level the device will
dim the lights to when the push pad is pressed to turn OFF.
In this mode the lights will always remain ON at a reduced
energy consumption level.
ON Fade Rate
– Set the amount of time in seconds it takes
the lights to turn ON to maximum brightness
OFF Fade Rate
– Set the amount of time in seconds it takes
the lights to turn OFF from maximum brightness
LED Options
– Set the time period in seconds the Locator
LED and Brightness Display will stay lit before extinguishing
Restore Defaults
– Restores the factory default settings
MODE
DESCRIPTION
RANGE
DEFAULT
A-1
Energy Save
100% - 75%
100%
A-2
Minimum Brightness Level
1% - 50%
LED 2
A-3
Preset On Level
1% - 100%, not active Not active
A-4
Almost OFF Level
1% - 50%
Not active
B-1
On Fade Rate
0s – 25s
0.5 seconds
B-2
OFF Fade Rate
0s – 25s
0.5 seconds
B-3
LED Options
Active, turn off after 5s Active
C
Restore Defaults
ADVANCEDFEATURESSUMMARY
Leviton Mfg. Co., Inc.
59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com
© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
LocatorLight
PushPad
LEDBrightnessDisplay
SECTION B
Leftmost LED = LED 1
Rightmost LED = LED 7
APPLICABLE CAT. NUMBERS
VPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPZX12-7, VPH08, VPH06-7
VPI06
Vizia +™ Programming Guide
Leviton Mfg. Co., Inc.
59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com
© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
Section C
Dimmer Programming
VPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPX12,
VPH08, VZH06
NOTES:
•Have a flashlight handy if this dimmer controls
the only light source in the room
•The device will exit programming mode after
3 minutes of inactivity
•Pressing the Push Pad at any time during
programming will advance the device to the
next programming mode.
Program Mode A
To enter Program Mode A:
Push and hold the Push Pad and then the
right
half of
the DIM/BRIGHT Bar (^) for 5 seconds until the Locator
LED and leftmost LED (LED 1) begin to blink.
A-1)
Upon releasing the Push Pad and the
right
half of the DIM/BRIGHT Bar (^) , the Locator
LED will continue to blink once per second and
the rightmost LED will illuminate to display the
device is in Program Mode
A-1, Energy Save
.
To change the
Energy Save Level
, use the
DIM/BRIGHT Bar to move the corresponding LED
to the desired discrete preset level according to
Chart A
. By tapping the Push Pad this setting
will automatically be saved and the device will
advance to the next programming mode,
A-2
.
A-2)
The Locator LED will blink 2 times per second to
indicate the device is in Program Mode
A-2,
Minimum Brightness Level
. To change the
Minimum Brightness Level
from 1-50%, use the
DIM/BRIGHT Bar. The light output will reflect the
minimum brightness level selected. By tapping
the Push Pad this setting will automatically be
saved and the device will advance to the next
programming mode,
A-3
.
A-3)
The Locator LED will blink 3 times per second to
indicate Program Mode
A-3, Preset ON Level
. To
change the current
Preset ON Level
from 1-100%,
use the DIM/BRIGHT Bar. If this feature is not
desired, press and hold the
left
half of the
DIM/BRIGHT Bar ( ) until no LED is lit (default
setting). By tapping the Push Pad this setting will
automatically be saved and the device will
advance to the next programming mode,
A-4.
A-4)
The Locator LED will blink 4 times per second to
indicate Program Mode
A-4
,
Almost OFF Level
.
To change the current
Almost OFF Level
, use the
DIM/BRIGHT Bar to adjust the preset light level.
If this feature is not desired, press and hold the
right half of the DIM/BRIGHT Bar (^) until no
LED is lit (default setting).
Almost OFF
can be
overridden by pressing and holding the left half of
the DIM/BRIGHT Bar ( ) until the lights turn off.
By tapping the Push Pad this setting will
automatically be saved and the device will
exit Programming Mode A.
Note:
When
Almost OFF Level
is set the LED Locator
will be illuminated when the dimmer is in the
Almost
OFF
state, even though the light remains on at a
reduced energy consumption level.
Program Mode B
To enter Program Mode B:
Push and hold the Push Pad and then the
left
half of the
DIM/BRIGHT Bar ( ) for 5 seconds until the Locator LED
and rightmost LED (LED 7) begin to blink.
B-1)
Upon releasing the Push Pad, the Locator LED will
continue to blink once per second indicating the
dimmer is in Program Mode
B-1, ON Fade Rate
. To
change the
ON Fade Rate
, use the DIM/BRIGHT Bar
to move the LED to the desired preset level according
to
Chart B
. By tapping the Push Pad this setting will
automatically be saved and the device will advance
to the next programming mode,
B-2
.
B-2)
The Locator LED will blink 2 times per second to
indicate Program Mode
B-2
,
OFF Fade Rate
. To
change the
OFF Fade Rate
, use the DIM/BRIGHT Bar
to move the LED to the desired preset level according
to the
Chart B
. By tapping the Push Pad this setting
will automatically be saved and the device will
advance to the next programming mode,
B-3
.
^
^
^
LED
MAXIMUM BRIGHTNESS
ENERGY SAVINGS
LED 1 75%
34% savings
LED 2 80%
29% savings
LED 3 85%
24% savings
LED 4 90%
16% savings
LED 5 95%
8% savings
LED 6 97%
5% savings
LED 7 100% (full bright)
0 % Savings
(Default)
ADVANCEDFEATURESSUMMARY
CHART A
LED 1
0 seconds (instant) 0 seconds (instant)
LED 2 (Default) 0.5 seconds
0.5 seconds
LED 3
1.5 seconds
1.5 seconds
LED 4
3 seconds
3 seconds
LED 5
6 seconds
6 seconds
LED 6
10 seconds
10 seconds
LED 7
25 seconds
25 seconds
LED
FADEON
FADEOFF
CHART B
B-3)
The Locator LED will blink 3 times per second
to indicate Program Mode
B-3, LED Options
.
To change the
LED Options
settings, use the
DIM/BRIGHT Bar to move the LED to the desired
preset setting according to the chart below.
By tapping the Push Pad this setting will
automatically be saved and the device will
exit Programming Mode B
Program Mode C
To enter Program Mode C:
Engage the air-gap switch by gently pressing the top of
the Push Pad until the bottom lifts
completely out of the frame and a click is heard.
All LEDs will extinguish.
C)
Press Push Pad back into the frame and hold for
7 seconds until and the LED Brightness Display
starts bi-directional strobing to indicate Program
Mode C,
Restore Default.
To
Restore Default
settings, release the Push Pad. This will save
defaults settings and exit Programming Mode C.
Leviton Mfg. Co., Inc.
59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com
© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
Vizia +™ Programming Guide
LED 1 Active
Active
LED 2 Active
Turns off 5 seconds after use
LED 3 Turns off 5 seconds after use Active
LED 4 Turns off 5 seconds after use Turns off 5 seconds after use
LED 5 N/A
N/A
LED 6 N/A
N/A
LED 7 N/A
N/A
LEDLOCATORLEDTIMEOUTLEDBRIGHTNESS
DISPLAYOPTIONS
LED OPTIONS CHART
Default
Active
First toggle Turns off 5 seconds after use
LOCATORLEDLOCATORLEDOPTIONSETTING
SWITCH PROGRAMMING
LED Option -
Sets the Locator LED timeout to
5 seconds after use.
NOTE:
The switch will exit program mode after
3 minutes of inactivity
Program Mode
To enter Program Mode:
Push and hold the Push Pad for 10 seconds until the
Locator LED begins to blink. Upon releasing the Push
Pad, the
LED Option
will automatically be changed.
LocatorLight
PushPad
VPS15
Leviton S. de R.L. de C.V.
Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX: (+52) 5386-1797 • www.leviton.com.mx
G-7904/J7-tp
Leviton Manufacturing of Canada, Ltd.
165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853
Leviton Manufacturing Co., Inc.
59-25 Little Neck Parkway, Little Neck, NY 11362-2591
Telephone: 1-800-323-8920 • FAX: 1-800-832-9538 • Tech Line (8:30AM-7:30PM E.S.T. Monday-Friday): 1-800-824-3005
Visit our Website at: www.leviton.com
© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.
Vizia +™ Programming Guide
LED 1 (Default) Active
Active
LED 3
Active
Turns off 5 seconds
after use
LED 7
Turns off 5 seconds Turns off 5 seconds
after use
after use
LED
LEDLOCATORLEDBRIGHTNESS
TIMEOUT
DISPLAYTIMEOUT
FAN SPEED CONTROL PROGRAMMING
VPF01
Preset ON Level
– Set the turn on fan speed
regardless of the previous set level
LED Options
– Set the time period in seconds
the Locator LED and Fan Speed will stay lit
before extinguishing
Restore Defaults
– Restores the factory default
settings (including device load ON at maximum level)
NOTES:
•The device will exit program mode after 3 minutes
of inactivity
•Pressing the Push Pad at any time during
programming will advance the device to
the next programming mode.
Program Mode A
To enter Program Mode A:
Push and hold the Push Pad and then the
right
half of
the FAN SPEED Bar (^) for 5 seconds until the Locator LED
and leftmost LED (LED 1) begin to blink. The Locator LED
will blink once per second to indicate Program Mode A,
Preset ON Level.
To change the current
Preset ON
Level
from HIGH (LED 7), MEDIUM (LED 4) or LOW (LED 1),
use the FAN SPEED Bar. If this feature is not desired,
press and hold the
left
half of the FAN SPEED Bar ( )
until no LED is lit (default setting). By tapping the Push
Pad this setting will automatically be saved and the
device will exit Programming Mode A.
Program Mode B
To enter Program Mode B:
Push and hold the Push Pad and then the
left
half of
the FAN SPEED Bar ( ) until the rightmost LED (LED 7)
begins to blink. The Locator LED will blink 2 times per
second to indicate Program Mode B,
LED Options
Mode. To change the
LED Options
settings, use the
FAN SPEED Bar to move the LED to the desired preset
setting according to the chart below. By tapping the
Push Pad this setting will automatically be saved and
the device will exit Programming Mode B.
Program Mode C
To enter Program Mode C:
Engage the air-gap switch by gently pressing the top of
the Push Pad until the bottom lifts completely out of the
frame and a click is heard. All LEDs will extinguish.
Press Push Pad back into the frame and hold Push Pad
for 7 seconds until the LED Brightness Display starts
bi-directional strobing to indicate Program Mode C,
Restore Default
.
Releasing the Push Pad will
Restore
Default
settings and exit programming mode.
^
^
FanSpeedBar
LocatorLight
PushPad
LEDBrightnessDisplay
MODE DESCRIPTION RANGE
DEFAULT
A Preset On Level 1% - 100%, not active Not active
B LED Options Active, turn off after 5s Active
C Restore Defaults
ADVANCEDFEATURESSUMMARY
Vizia +™ is a trademark of Leviton Manufacturing Co., Inc.
Covered by one or more U.S. and Foreign Patents and patents pending.
of 4


Related Products

Leviton VRF01-1LZ - Z-Wave Fan Controller
Leviton VRF01-1LZ
Z-Wave Fan Controller

Related Categories


Document Transcript

1. TECHNICAL APPLICATION NOTEProgramming Guide for Vizia + Dimmersand Quiet Fan Speed ControlVizia+™ProgrammingGuideDim/Bright BarVIZIA + DIMMERS PROVIDE THE FOLLOWINGADVANCED PROGRAMMING FEATURES:I. DIMMER PROGRAMMINGSECTION A• Energy Save - Set the maximum brightness levelfor energy savings• Minimum Brightness Level – Set the minimumdimming level• Preset ON Level – Set the turn on brightness levelregardless of the previous set light level (formerly Dim Lock)• Almost OFF Level – Sets the brightness level the device willdim the lights to when the push pad is pressed to turn OFF.In this mode the lights will always remain ON at a reducedenergy consumption level.• ON Fade Rate – Set the amount of time in seconds it takesthe lights to turn ON to maximum brightness• OFF Fade Rate – Set the amount of time in seconds it takesthe lights to turn OFF from maximum brightness• LED Options – Set the time period in seconds the LocatorLED and Brightness Display will stay lit before extinguishing• Restore Defaults – Restores the factory default settingsMODE DESCRIPTION RANGE DEFAULTA-1 Energy Save 100% - 75% 100%A-2 Minimum Brightness Level 1% - 50% LED 2A-3 Preset On Level 1% - 100%, not active Not activeA-4 Almost OFF Level 1% - 50% Not activeB-1 On Fade Rate 0s – 25s 0.5 secondsB-2 OFF Fade Rate 0s – 25s 0.5 secondsB-3 LED Options Active, turn off after 5s ActiveC Restore DefaultsADVANCED FEATURES SUMMARYLeviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Locator LightPush PadLED Brightness DisplaySECTION BLeftmost LED = LED 1Rightmost LED = LED 7APPLICABLE CAT. NUMBERSVPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPZX12-7, VPH08, VPH06-7VPI06
2. Vizia+™ProgrammingGuideLeviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Section CDimmer ProgrammingVPI06, VPM06, VPM10, VPE04, VPE06, VPX10, VPX12,VPH08, VZH06NOTES:• Have a flashlight handy if this dimmer controlsthe only light source in the room• The device will exit programming mode after3 minutes of inactivity• Pressing the Push Pad at any time duringprogramming will advance the device to thenext programming mode.Program Mode ATo enter Program Mode A:Push and hold the Push Pad and then the right half ofthe DIM/BRIGHT Bar (^) for 5 seconds until the LocatorLED and leftmost LED (LED 1) begin to blink.A-1) Upon releasing the Push Pad and the righthalf of the DIM/BRIGHT Bar (^) , the LocatorLED will continue to blink once per second andthe rightmost LED will illuminate to display thedevice is in Program Mode A-1, Energy Save.To change the Energy Save Level, use theDIM/BRIGHT Bar to move the corresponding LEDto the desired discrete preset level according toChart A. By tapping the Push Pad this settingwill automatically be saved and the device willadvance to the next programming mode, A-2.A-2) The Locator LED will blink 2 times per second toindicate the device is in Program Mode A-2,Minimum Brightness Level. To change theMinimum Brightness Level from 1-50%, use theDIM/BRIGHT Bar. The light output will reflect theminimum brightness level selected. By tappingthe Push Pad this setting will automatically besaved and the device will advance to the nextprogramming mode, A-3.A-3) The Locator LED will blink 3 times per second toindicate Program Mode A-3, Preset ON Level. Tochange the current Preset ON Level from 1-100%,use the DIM/BRIGHT Bar. If this feature is notdesired, press and hold the left half of theDIM/BRIGHT Bar ( ) until no LED is lit (defaultsetting). By tapping the Push Pad this setting willautomatically be saved and the device willadvance to the next programming mode, A-4.A-4) The Locator LED will blink 4 times per second toindicate Program Mode A-4, Almost OFF Level.To change the current Almost OFF Level, use theDIM/BRIGHT Bar to adjust the preset light level.If this feature is not desired, press and hold theright half of the DIM/BRIGHT Bar (^) until noLED is lit (default setting). Almost OFF can beoverridden by pressing and holding the left half ofthe DIM/BRIGHT Bar ( ) until the lights turn off.By tapping the Push Pad this setting willautomatically be saved and the device willexit Programming Mode A.Note: When Almost OFF Level is set the LED Locatorwill be illuminated when the dimmer is in the AlmostOFF state, even though the light remains on at areduced energy consumption level.Program Mode BTo enter Program Mode B:Push and hold the Push Pad and then the left half of theDIM/BRIGHT Bar ( ) for 5 seconds until the Locator LEDand rightmost LED (LED 7) begin to blink.B-1) Upon releasing the Push Pad, the Locator LED willcontinue to blink once per second indicating thedimmer is in Program Mode B-1, ON Fade Rate. Tochange the ON Fade Rate, use the DIM/BRIGHT Barto move the LED to the desired preset level accordingto Chart B. By tapping the Push Pad this setting willautomatically be saved and the device will advanceto the next programming mode, B-2.B-2) The Locator LED will blink 2 times per second toindicate Program Mode B-2, OFF Fade Rate. Tochange the OFF Fade Rate, use the DIM/BRIGHT Barto move the LED to the desired preset level accordingto the Chart B. By tapping the Push Pad this settingwill automatically be saved and the device willadvance to the next programming mode, B-3.^^^LED MAXIMUM BRIGHTNESS ENERGY SAVINGSLED 1 75% 34% savingsLED 2 80% 29% savingsLED 3 85% 24% savingsLED 4 90% 16% savingsLED 5 95% 8% savingsLED 6 97% 5% savingsLED 7 100% (full bright) 0 % Savings(Default)ADVANCED FEATURES SUMMARYCHART ALED 1 0 seconds (instant) 0 seconds (instant)LED 2 (Default) 0.5 seconds 0.5 secondsLED 3 1.5 seconds 1.5 secondsLED 4 3 seconds 3 secondsLED 5 6 seconds 6 secondsLED 6 10 seconds 10 secondsLED 7 25 seconds 25 secondsLED FADE ON FADE OFFCHART B
3. B-3) The Locator LED will blink 3 times per secondto indicate Program Mode B-3, LED Options.To change the LED Options settings, use theDIM/BRIGHT Bar to move the LED to the desiredpreset setting according to the chart below.By tapping the Push Pad this setting willautomatically be saved and the device willexit Programming Mode BProgram Mode CTo enter Program Mode C:Engage the air-gap switch by gently pressing the top ofthe Push Pad until the bottom liftscompletely out of the frame and a click is heard.All LEDs will extinguish.C) Press Push Pad back into the frame and hold for7 seconds until and the LED Brightness Displaystarts bi-directional strobing to indicate ProgramMode C, Restore Default. To Restore Defaultsettings, release the Push Pad. This will savedefaults settings and exit Programming Mode C.Leviton Mfg. Co., Inc.59-25 Little Neck Pkwy, Little Neck, NY 11362-2591 Tech Line: 1-800-824-3005 Fax: 1-800-832-9538 www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Vizia+™ProgrammingGuideLED 1 Active ActiveLED 2 Active Turns off 5 seconds after useLED 3 Turns off 5 seconds after use ActiveLED 4 Turns off 5 seconds after use Turns off 5 seconds after useLED 5 N/A N/ALED 6 N/A N/ALED 7 N/A N/ALED LOCATOR LED TIMEOUT LED BRIGHTNESSDISPLAY OPTIONSLED OPTIONS CHARTDefault ActiveFirst toggle Turns off 5 seconds after useLOCATOR LED LOCATOR LED OPTION SETTINGSWITCH PROGRAMMING• LED Option - Sets the Locator LED timeout to5 seconds after use.NOTE: The switch will exit program mode after3 minutes of inactivityProgram ModeTo enter Program Mode:Push and hold the Push Pad for 10 seconds until theLocator LED begins to blink. Upon releasing the PushPad, the LED Option will automatically be changed.Locator LightPush PadVPS15
4. Leviton S. de R.L. de C.V.Lago Tana 43, Mexico DF, Mexico CP 11290 • Tel. (+52) 55-5082-1040 • FAX: (+52) 5386-1797 • www.leviton.com.mxG-7904/J7-tpLeviton Manufacturing of Canada, Ltd.165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 • Telephone: 1-800-469-7890 • FAX: 1-800-563-1853Leviton Manufacturing Co., Inc.59-25 Little Neck Parkway, Little Neck, NY 11362-2591Telephone: 1-800-323-8920 • FAX: 1-800-832-9538 • Tech Line (8:30AM-7:30PM E.S.T. Monday-Friday): 1-800-824-3005Visit our Website at: www.leviton.com© 2008 Leviton Manufacturing Co., Inc. All rights reserved. Subject to change without notice.Vizia+™ProgrammingGuideLED 1 (Default) Active ActiveLED 3 Active Turns off 5 secondsafter useLED 7 Turns off 5 seconds Turns off 5 secondsafter use after useLED LED LOCATOR LED BRIGHTNESSTIMEOUT DISPLAY TIMEOUTFAN SPEED CONTROL PROGRAMMINGVPF01• Preset ON Level – Set the turn on fan speedregardless of the previous set level• LED Options – Set the time period in secondsthe Locator LED and Fan Speed will stay litbefore extinguishing• Restore Defaults – Restores the factory defaultsettings (including device load ON at maximum level)NOTES:• The device will exit program mode after 3 minutesof inactivity• Pressing the Push Pad at any time duringprogramming will advance the device tothe next programming mode.Program Mode ATo enter Program Mode A:Push and hold the Push Pad and then the right half ofthe FAN SPEED Bar (^) for 5 seconds until the Locator LEDand leftmost LED (LED 1) begin to blink. The Locator LEDwill blink once per second to indicate Program Mode A,Preset ON Level. To change the current Preset ONLevel from HIGH (LED 7), MEDIUM (LED 4) or LOW (LED 1),use the FAN SPEED Bar. If this feature is not desired,press and hold the left half of the FAN SPEED Bar ( )until no LED is lit (default setting). By tapping the PushPad this setting will automatically be saved and thedevice will exit Programming Mode A.Program Mode BTo enter Program Mode B:Push and hold the Push Pad and then the left half ofthe FAN SPEED Bar ( ) until the rightmost LED (LED 7)begins to blink. The Locator LED will blink 2 times persecond to indicate Program Mode B, LED OptionsMode. To change the LED Options settings, use theFAN SPEED Bar to move the LED to the desired presetsetting according to the chart below. By tapping thePush Pad this setting will automatically be saved andthe device will exit Programming Mode B.Program Mode CTo enter Program Mode C:Engage the air-gap switch by gently pressing the top ofthe Push Pad until the bottom lifts completely out of theframe and a click is heard. All LEDs will extinguish.Press Push Pad back into the frame and hold Push Padfor 7 seconds until the LED Brightness Display startsbi-directional strobing to indicate Program Mode C,Restore Default. Releasing the Push Pad will RestoreDefault settings and exit programming mode.^^Fan Speed BarLocator LightPush PadLED Brightness DisplayMODE DESCRIPTION RANGE DEFAULTA Preset On Level 1% - 100%, not active Not activeB LED Options Active, turn off after 5s ActiveC Restore DefaultsADVANCED FEATURES SUMMARYVizia +™ is a trademark of Leviton Manufacturing Co., Inc.Covered by one or more U.S. and Foreign Patents and patents pending.


Uploaded