Qolsys IQ Flood Sensor Quick Installation Guide



Related Products

Qolsys IQ Flood - Flood sensor for the Qolsys IQ and IQ Panel 2 (QS-5516-840)
Qolsys IQ Flood
Flood sensor for the Qolsys IQ and IQ Panel 2

Related Categories


Document Transcript

Sensor: 2.5”H x 1”W x .5”D
Wireless signal range: 600ft (200M), open air.
Code outputs: tamper, tamper restore, alarm, alarm
restore, low
battery.
Transmitter frequency: 319.5 MHz
Unique code ID
Supervisory keep-alive interval: 70 minutes.
RF Peak field strength: typical 36000 uV/m at 3m
Operating Temperature: -10C~50C
Relative Humidity: 5-95% Non-Condensing
Storage Temperature: -40-80C
Replace battery with exact replacement every 5 years
with
3V Lithium (x2).
(2) -Panasonic CR2032
-Energizer CR2032
-Duracell DL2032
STEP
1
IQ FLOOD QUICK INSTALL GUIDE
CHOOSE
INSTALLATION
LOCATION
SPECIFICATIONS
Water heater
Basements
Laundry rooms
Sump pumps
Kitchen sinks
Bathroom sinks
Bathrooms
This is a quick guide for experienced installers only. Refer to http://dealers.qolsys.com (login required)
STEP
2
STEP
3
REMOVE
BATTERY
TABS
STEP
4
MOUNT
SENSOR
STEP
5
LEARN
INTO
PANEL
Document#: IQFLOOD-QG-02-17

Revision#: 2/24/17

Issue Date: FEB 2017

Qolsys Product #: QS5516-840
Water detection unit rests or mounts to the floor or can be mounted to a wall
or baseboard. Trim or tie off extra cord as needed or desired.
APPLY
ADHESIVE
Mount the sensor above the floor level to prevent water damage.

Place your panel in
“autolearn" mode
Customize name and settings
as desired and and touch “ADD”
ADD
Open and close the case
to “tamper” the device
Qolsys Inc. proprietary.
Reproduction without permission is not permitted.
FCC ID: 2ABBZ-RF-
MDWS
IC: 11817A-RF
MDWS
TechSupport@Qolsys.com
CONTACT TECH SUPPOR
T
GOT QUESTIONS?
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired
operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
This device complies with Industry Canada licence-exempt RSS standard(s). Operation is subject to the following two conditions: (1) this device may not cause interference, and (2) this device must accept any interference, including interference
that may cause undesired operation of the device.
Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil doit accepter toute
interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.


Uploaded